26ga (min ) A"MA% over 15/32" (rain) plywood
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/8".
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507-4-3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required-
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave ##206 1 Gainesville FL
FL PE 81377 l FL CA 33344
www.TimberLakeCove.com
E.
David E Eng = No.81377 =
�r 9�2020.10.06 -
00:08:33+01'00=
STATE OFF
'ice 'r1 Oft1OA.•' 1R;�
This,1- been digitally si• -.
t sealed by 1
date indicated.Printedr. -s of this
AX
.. - f • • •- �. signed
VM
and seeied and the stgnatire must be\10~oft any ele==copies
Crim f ExposedSeam.
' r�Ni'AX .
Underlaymen t: Comply with local building code or FBC 1507-1.1 where required.
Slope: Comply with local building code or FBC 1507.4-2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A- #9 x 1 5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF
Method B- #10 x 1 5" fastener in 12"-12" pattern at 16" o.c.: 93.5 PSF
Method C- #10 x 1 5" fastener in 12"-12" pattern at 8" o.c.: 101 PSF
Method D: #10 x 1.5" fastener in 12"-12" pattern at 6" o.c.: 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method ID_
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16-
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company'
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3-2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
WMAX
ry
Instructions:
Select the appropriate load table that applies to the �a
structure in question.
Determine the design wind speed for the project a 2 2 3
location_ 2
1 1 2
Use the attachment method indicated for that 2
windspeed within each roof zone_ 2 2 3 a
2 3 2 2 3 a
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. f +t
For the load tables below, the worst case was taken 2/
for each zone and reported using the standard zones 1 2
1-2-3:
Zone 1 includes zones 1 and 1' I I
a Zone 2 includes zones 2e, 2r, and 2n �—.lal, KIP ROOF GABLE ROOF -Ja L
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple ; �K`� y�E, �� pPm rsrno`rnA � H6
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information, !ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A: METHOD IB: METHOD C. METHOD D.
#9 AT 16"O-C. #10 AT 16"O.;C_ #10 AT 8"O_C_ #10 AT 6"O:C.
1- 12"(NOM) 12"(NOM) NR:NOT RATED.CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gablethip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15/32" plvwgod FL17022.01: 26 a 5V Crimp on 15/32" plVwoqd
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: -A A A A A. A A A _A A_ A Zone 1: A A A A A A_ A_ C �D D D
Zone 2: A A -A A A_ A A- A C ' D D Zone 2: A A A A C D D D D D D
Zone 3: A A A A A A B C D D D i Zone 3: A A A C D D D D D D
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 7°,hip roof with Have either a flat roof less than 7°,hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26_a rimp on 15132" plywood FL17022.01: 26 a 5V Crimp on 15/32"_plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180_190 200
Zone 1: A A A A' A A A A A A A_ __ Zone 1: A A A A A A A B C DD D
Zone 2: A A A A A A A- A A B C Zone 2: A A A A A B D D D D D
Zone 3: A. A A A A. A A B i D- D -D- Zone 3: A A A B- D D D - D D -D D ?
RECEIVED
FEB 1 He Copy
St.Lucie County �i
Permitting RMEWLED FOR 6lEMp/� et�`c
ItlA® i-tl.�a
CODE COMPLIA C �
Certificate of Authorization#32455
ut4 STo L=E COUNTY 353 Christian Street,Unit#13
BOCC2/1 Z/zZ Oxford, 6 06478
-9245
(203)229245
ENGINEER EVALUATE TEST CONSULT
r l Ry.����T�� xi` t
`:d � � i" , w'�45...Y'S T..• _..,.'e.eR rF<, _ _ .vk3f _1N iF�
GAF Evaluation Report 01506.04.08-1122
1Campus Drive FL10626-1122
Parsippany,NJ 07054 Date of Issuance:04/25/2008
(800)766-3411 Revision 22:06/09/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 71 Edition(2020)Florida Building Code sections noted
herein.
DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC,i LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Q�Qtr
Robert J.M.Nieminen P.E. '=
z .
: IV--`: The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 06/09/2021.This does not serve as an
` '+• +n"" electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC,LLC
�NNEMOJetc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments,as produced by GAF,have demonstrated compliance with the
following sections of the 7'Edition(2020)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations[Conditions of Use set forth
herein.
kr�z -W
n"5.._.:' ,atr.
Section Property Standard - Year
1504.3.1 Wind resistance FM 4474 2011
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.1(2&3;
Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.1.1/R905.1.1 Material standard ASTM D6757 2016
1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
:. �i'._`"f �, r y a?�''�u .t+F ,s`4r�a f^� t$ t 5�.i�`�e� ,�'S#��'rD,k' •� i�,y�y^'` �>.^a+2 r<*+-.'
Enti Examination : -Reference-. Date
ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011
ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014
ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017
ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017
Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016
NEMO(TST 6049) Physical Properties(ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019
NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020
NEMO(TST 6049) ASTM D4798,TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021
NEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021
PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011
PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012
PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012
PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013
PRI(TST 5878) ASTM D4533(various) GAF-818-02-01 12/05/2017
PRI(TST 5878) ASTM D1970(AL) MSA-047-02-01 04/11/2018
PRI(TST 5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019
PRI(TST 5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019
PRI(TST 5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019
PRI(TST5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION 171-10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
NNEMOJetc.
Ent i Examination Reference Date
PRI(TST 5878) ASTM D1970(AR) 376T0032 10/22/2019
PRI(TST 5878) ASTM D226(S-CA) 376TOO54 02/18/2020
PRI(TST 5878) ASTM D4533(Gujarat,India) 376TOO58 02/18/2020
PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020
PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376T0111 12/22/2020
PRI(TST 5878) ASTM D4533,D5035(Gujarat,India) 376TO113 12/22/2020
UL(TST 1740) ASTM D6757(TX) 02NK22569 06/04/2002
PRI(TST 5878) ASTM D5035(Gujarat,India) 376TO146 03/11/2021
PRI(TST5878) ASTM D4533,D5035(Rajasthan,India) 376TO161 05/07/2021
UL(TST 1740) ASTM D6757(NC) IONK11990 05/18/2011
NEMO ETC Traceability FBC Cross-Listing 04/22/2020
NEMO Traceability FBC Cross-Listing 04/08/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation 03/23/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020
UL,LLC(QUA 9625) Quality Control Florida BCIS Current
Product Material Standard.` Plant(s)
4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada
4.2 Liberty'"SBS Self-Adhering Base/Ply ASTM D1970 Mt.Vernon,IN
Sheet Savannah,GA
4.3 StormGuard°Film-Surfaced Leak Barrier ASTM D1970 Mt.Vernon,IN
Savannah,GA
Arkadelphia,AR
WeatherWatch®Mineral-Surfaced Leak Mt.Vernon,IN
4.4 Barrier ASTM D1970 Savannah,GA
Tuscaloosa,AL
Deck-Armor'"Premium Breathable Roof 1507.1.1.1(2&3,Exception)/
4.5 Deck Protection R905.1.1.1(2&3,Exception) Dadra,India
Dadra,India
FeltBuster'"Synthetic Roofing Felt 1507.1.1.1(2&3,Exception), Gujarat,India
(CPP)Rajasthan,India
4.6 (formerly FeltBuster—High-Traction Synthetic 1507.1.1.1(5)/R905.1.1.1(2&3, (MIP)Rajasthan,India
Roofing Felt) Exception),R905.1.1.1(5)
Richmond,VA
Spartanburg,SC
4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,OK
Shafter,CA
1507.1.1.1(2&3,Exception)/
4.8 StormSafeTM Anchor Sheet North Bay,ON
R905.1.1.1(2&3,Exception)
Tiger Paw"Premium Roof Deck Dadra,India
1507.1.1.1(2&3,Exception)/ Gujarat,India
4.9 Protection(formerly TigerPawTMRoofDeck R905.1.1.1(2&3,Exception) Parzai,India
Protection)
Umerkui Kilvani,India
4.10 VersaShield®Fire-Resistant Roof Deck ASTM D6757 Conover,NC
Protection
4.11 Ruheroid®Mop Granule ASTM D6164 Savannah,GA
FRSA/TRI 09-18
4.12 Ruberoid®Mop Granule FR ASTM D6164 Savannah,GA
FRSA/TRI 09-18
MEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
I
NNEM"oletc.
5.1 This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1:=ROOF COVER OPTIONS
FBC-Section: 1507.2 '1507.3 1507.4 and 1507.5 1507.7 1507.8 and 1507.9
Clay and Concrete Tile Metal Slate or Wood
Asphalt Mechanical echanical Adhesive- � �" Slate-Type
Shingles= Attach Set Panels Shingles- Shingles Shingles Shakes
Yes Yes
GAF Extended Dry-In Membrane Yes No No Yes Yes Yes Goint strips, Goint strips,
1507.1.13/ 1507.1.1.3/
R905.1.13) R905.1.1.3)
Yes Yes
Liberty-SBS Self-Adhering
Yes No No No No No Uointstrips, (joint strips,
Base/Ply Sheet 1507.L1.3/ 1507.1.1.3/
R905.1.13) R905.1.1.3)
Yes Yes
StormGuard®Film-Surfaced Leak eDint Yes No No Yes Yes Yes 1507.Li3/Barrier 1507.1.L3/
R905.1.1.3) 11905.1.13)
Yes Yes
WeatherWatch®Mineral-Surfaced Goint strips,
Leak Barrier Yes No No No No No Doint 1507.1.1.3 strips, 1507.1.13/
R905.1.1.3) R905.1.1.3)
Deck-Armor'"Premium Breathable Yes No No Yes Yes Yes No No
Roof Deck Protection
FeltBuster-Synthetic Roofing Felt Yes No No No No No No No
Shingle-Mate®Roof Deck Yes No No No No No No No
Protection
Tiger Paw"Premium Roof Deck Yes No No Yes Yes Yes No No
Protection
VersaShield®Fire-Resistant Roof
Yes No No No No No No No
Deck Protection
Yes Yes
Ruberoid®Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system) 2-ply system)See 5.6.1
Yes Yes
Ruberoid®Mop Granule FR No (Cap Sheet in (gyp Sheet in No No No No No
2-ply system) 2-plysystem)
See 5.6.1
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
�NNEM.
I etc®
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS)
Underlayment Adhesive Florida Product Approval
Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bondi"Roof Tile Adhesive" FL22525
5.7 Allowable Substrates:
TABLE 2.: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Primer Substrates
GAF Extended Dry-In Membrane self-adhering None plywood
Liberty'"SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering (Optional) plywood
ASTM D41
Weather Watch"Mineral-Surfaced Leak Barrier
Liberty—SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II
Weather Watch®Mineral-Surfaced Leak Barrier
Liberty"SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering ASTM D41 metal(flashing metal,valley metal,
etc.)
Weather Watch"Mineral-Surfaced Leak Barrier
Ruberoid®Mop Granule
hot asphalt ASTM D41 structural concrete
Ruberoid®Mop Granule FR
Ruberoid®Mop Granule GAFGLAS°#80 UltimaT"Base Sheet
Ruberoid®Mop Granule FR hot asphalt None or Ruberoid®20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 72:06/09/2021
*NEMO etc.
#1 Maximum Design Pressure=-442.5 psf.
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#2 Maximum Design Pressure=-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min.4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultimal Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 8-inch D.C.
at the min.4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaTM Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min.2-inch wide side laps and 4-inch D.C.at four(4),equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM 6312,Type
IV hot asphalt at 20 to 25 Ibs/square.
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization A32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22;06/09/2021
i
NNEMO etc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
P Maximum
repared Roof Cover
Underlayment Exposure
Installation Type
(days)
Deck-Armor-Premium Breathable Roof Deck Protection,FeltBusterT"Synthetic
Roofing Felt,Shingle-Mate®Roof Deck Protection,StormSafe—Anchor Sheet,Tiger
PawT"Premium Roof Deck Protection,VersaShield"Fire-Resistant Roof Deck Mechanically attached 30
Protection,Liberty-SBS Self-Adhering Base/Ply Sheet,StormGuard"Film-Surfaced
Leak Barrier and WeatherWatch"Mineral-Surfaced Leak Barrier
GAF Extended Dry-In Membrane Mechanically attached 180
Ruberoid"Mop Granule and Ruberoid"Mop Granule FIR Adhesive-set tile roof system 180
Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Flat Max.10-tile stack 4:12
Ruberoid"Mop Granule Flat Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 5:12
Ruberoid"Mop Granule PR Flat or Lugged Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 4:12
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate(if applicable).
6.3 - Deck-ArmorTM Premium Breathable Roof Deck Protection or Tiger-PawTM Premium Roof Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4 FeltBusterTM Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization N32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION -FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
i
MEMO etc.
6.5 StormSafe—Anchor Sheet:,
6.5.1 StormSafeT""Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install LibertyTM' SBS Self-Adhering Base/Ply; StormGuardm Film-Surfaced Leak Barrier or
WeatherWatch®Mineral-Surfaced Leak Barrier over the StormSafe'"Anchor Sheet.
6.6 Shingle-Mate®Roof Deck Protection:
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShield®Fire-Resistant Roof Deck Protection:
6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D6757)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF Extended Dry-In Membrane,Liberty'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak
Barrier or WeatherWatch®Mineral-Surfaced Leak Barrier:
6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c.,encapsulated within
min.4-inch side laps.
6.8.3 When installed over a mechanically attached,FBC Approved ASTM D226 Type If felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 GAF Extended Dry-In Membrane,Liberty'"SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak
Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.9 Ruberoid®Mop Granule;RuberoidO Mop Granule FIR:
6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet"in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition,and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations.
6.9.3 Refer to Table 4 for the staging limitations.
g g
NEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization U32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
I
I
MEMO I etc.
As required by the Building Official _- ..
q ' I or Authority Having Jurisdiction to properly evaluate the installation of this
product.
?tea '
-iS-.. '';.
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
a r...0 rT�a'Y�+.+���`�'�.- wA«P"u hym�}'r-rivt''cx'i.W T.:;Nbso�,g9Ns•+nrr r+ `' - -
a^.r g �' I7/U�iI" ht �`° ax'_ z-c f .r''t-c.s t � ;
_ '?:^'»t..._ _._. r.-.�:' -.
UL,LLC.—QUA9625;(414)248-6409;karen.buchmann@ul,com
-END OF EVALUATION REPORT-