HomeMy WebLinkAboutElectric Sign Mounted To Building WallELECTRIC SIGN BOX MOUNTED TO BUILDING WALL
LOCATION: 15' OAH x 50' FRONTAGE = 750 x 20% =150 50 FT OF CONTRACTOR:
BILLY B10602 U5- TACKLE 51GNAGE ALLOWED TO CODE SIGN IT! BAKER
639 NW BAKER RE)
PORT SAINT LUCIE, FL 2411 x 120" = 20 5Q FT OF 51GNAGE STUART, FL
34952 34994
MIN. SETBACK REQ.
FRONT
SIDES _
CNR SIDES
REAR
;-"NG.
'TECH.
A r.
Z-��f C>
REVIEWED FOh
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
Wall Connection Engineer of Record:
James D. Wells, Jr., P.E.
Professional Engineer No. 53616
J & L Wells Consulting LLC
1453 Arhitus Circle
Oviedo, PL 32765
(407)496-5489
Certificate of Authorization No. 27162
TYPICAL 5INGLE-FACED SIGN SOX MOUNTED TO BUILDING WALL
5IGN CABINET CON5TRUCTED OF ALUMINUM EXTRU51ON
TOTAL OF 8 FA5TENER5 TO 5E USED FROM 2' x 10' 51GN 5OX TO 5RACKET5
5ERVICE
NOTE: ELECTRICAL
DETAILS N SIIOWARE:
RESPONSIBILITY OF
ELECTRICAL CON'rRACa'OR.
SIGN sTRUCTURAL ENGINEER
DID NOT REVIEW AND IS NOT
PART OF STRUCTURAL
EVGiNEER'S SCOPE
PRE-ENGINEERED SIGN BOX
`& HEX HEAD 1/2" 5ELF DRILLING 5CREW5
@ MAX. 10" O.C. SPACING
RET
.040 ALUMINUM BACKING
60 W LED POWER SUPPLY
Engineer Notes:
e,ntractor to verify actual field
itions and notify Engineer if conditions
,,ind require different fasteners.
2. Seal all wall penetrations to
prevent water intrusion into building.
3. Anchors to be uniformly spaced. Anchors to be
stainless steel / galvanized.
# OF LED MODULES 55
MODULE WATTAGE .082 W
HEIGHT 24" WIDTH 120"
DEPTH 4" RETAINER5 1"
COLOR OF BOX DEEP BRONZE
COLOR OF RETAINER5 DEEP BRONZE
FACE: FLAT PAN EMD055ED PAINTED VINYL
DRAIN HOLES ALUMINUM EXTRU5ION
This structure has been designed in accordance with the
requirements of Chapter 16, Structural Design, of the 7th
Edition (2020) Florida Building Code. The following
wind load requirements, in accordance with Section
1609. were employed in the design of the structure:
Ultimate Design Wind Speed: 165 MPH (3-Second Gust
Wind Speed) - Port St Lucie, FL; Nominal Design Wind
Speed: 128IvIPH (3-Second Gust Wind Speed); Building
Risk Category: II; Wind Exposure: C; External Pressure
Coefficient, GCp = -1.4 / +1.0; Design Pressure: -42.3
PSF / +30.2 PSF
1-1/2':el-1/2"xl/8"
ALUM ANGLES
WELDED TO SIGN
BOX W/ 118"
ALL-AROUND
FILLET WELDS W/
4043 ALUM ALLOY
FILLER
LED MODULE5
• BOX MOUNTED TO WALL
3/8" x 4" LAG DOLT5
DIRECTLY INTO 2' x 4'
WOOD FRAMING
RFVIEWED FOR
CODIE CWAPLIANCE
LYall Connection Engineer of BST. LUC I F COUNTY
`
lames D. Wells, )r., P.E
Pro( sional Engineer No. 53616 [gyp
1 SrL Welts Consulting LLC P � 6°
-s�
y V
I l
1453 Arhitus Circle
L�
t l
(hind.. FL 32765
(407)496-5489
Certificate of Aulhorintion
No. 27162
BILLY 13ONE5 BAIT & TACKLE
10602 U5-1
PORT SAINT LUCIE, FL 34952
1 • •/ OFFICE #
1NO' 772-692-2866
639 N.W. BAKER ROAD STUART, FL 34994