Loading...
HomeMy WebLinkAboutGeneratorINCLUDES: • True Power"' Electrical Technology • Two-line multilingual digital LCD Evolution" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-FO' connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled for installation as close as 18 in (457 mm) to a structure.' 'Must he located away from doors, windows, and fresh airintakes and in accordance with local codes. FEATURES b 17 L O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's 6- Force engine lineup offers added peace of mind and reliability for.when it's needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY MOBILE LINK' CONNECTIVITY: FREE with select Guardian Series Home standby generators. Mobile Link Wi-Ft allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC� GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1. G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW e0 Hz 0007042-2, G007043-2, G007042-2. G007043-3 (Aluminum - Bisque) - 22 kW 80 Hz G007209-0, G007210-1 ,Aluminum - Bisque) - 24 kW 60 hz. cONus or GL®Os QVI n "'w . Note: CETL or CUL certificationonly applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are En. or UL certified in the USA only. • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system Is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at t1%. • SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. 0 GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. FILE COPY =IPROMISE GENERAC} 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution— Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit ® SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. 20/22/24 kW Installation System GEN ERACr Features and Benefits v 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. s Weather information Provides detailed local ambient weather conditions for generator location. GENERAC° 20/22/24 kW Specifications Generator Model G007D38-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 GO07D43-2 GDO7039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 0) (24" Rated maximum continuous power capacity (NG) 18,000 Watts' 19,500 Watts' 18,000 Watts- 19,500 Watts" 21,0Ou Watts- 'ed�trof�age�'"�`�r°m" Rated maximum continuous load current —240volts (LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 •xs^ -. r'" k :'E. .�:�"s.'f�;-W,.».�?'.�s'. Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp M Power factor 1.0 BrTep,E {itnYrOied ���`w "j y@. ,{� w Unit weight (lb /kg) 448/203 466/211 436/19B 445/202 455/206 with Exercise duration 5 min Engine Engine tvoe GENERAC G-Farce 1000 Series Valve arrangement Overhead valve Governor system Electronic Starter 12 VDC 3,600 must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG.10-12 in water tent, multiply ftaPor x 2500 (LP) or fla/hr x 1000 (NG). For Meaaioule content, multiply ml/hr x 93.15 (LP) or m3/hr x 37.26 (NG1. Two-line plain text multilingual LCD Automatic Low Oil messages Shutdown user interface for ease of operation. starter control. unit stays on. "-Sound ieveis are taken from Me front of the generator. Sound ievels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271).' Maximum Idlovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately3.5%for each 1,000 0 (304.8 m) above sea level; and also will decrease approximately 1 % for each 10 `F (6 `C) above 60 IF (16 �C). 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up 10 four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Main breakers are rated for 80% continuous load. • 2-pole. 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. , Dimensions 200 Amps 120/240,1a Open Transition Service Rated Heigh Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 210 - #14 GEM ERAC Switch Options G007039-1,6007039-3 (20 N) Model 6007043-2, 6007043-3 (22 kW) 8007210-1 24kw) f � '-� Current rating (amps) 200 tw, Utility voltage monitor (fixed)' -Pick-up 80% -Dropout 65% � � - «: 2 ETL or UL listed Standard Circuit breaker protected 22,000 •Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly l--vn --I 20/22/24 kW GENERAC" Available Accessories the battery. Recommended for use 'rf temperature regularly falls below 0 IF (-18 °C). (Not nec- G007101-0 Battery Pad Warmer Pad warmer rests under essary for use with AGM -style batteries). jG007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if temperature regulady falls below 0 IF (-18 °C). G007103-1 Breather Warmer IBreatherwarmer isfor use in extreme cold weather applications. For use with Evolution controllers only in climates where I ;heavy icing occurs, i6005621-0 'Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be {Contact Kit needed. Not compatible with 50 amp pre -wired switches. 1G007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, contoured j ](Standard on 22/24 kW) Jappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 1GO05703-0 - Bisque Touch -Up Paint hit Ili the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 6006485-0 .— Scheduled -Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). <GO07005-0 W Wi-Fl LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the failure. Sta- Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power jtus alerts are available through a free application to notify users when the LP tank is in need of a refill. 13007000-0 (50 amp) Smart Management Module 15mart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec- G007006-0 ltrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0 - 413 LTE Mobile Link° Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using PC. Easily information the maintenance alerts. Us - (G007170-0 - Wi-FV Accessories is smart phone, tablet, or access such as current operating status and (Ethernet Iusers ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, are taken care of before the next power outage. I0007220-0 - Bisque Base Plug Kit ]contains Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This offers a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit four plugs, sufficient for use on a single air-cooled home standby generator. I Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 0007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209-0 696471071511 G007210-1 696471084801 ig Dimensions & PCs LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2021 Generac Power Systems, Inc. All rights reserved. AO specifications are subject to change without notice. Part No. A0000937814 Rev. D 04/14/2021