HomeMy WebLinkAboutPool Energy Efficiency Compliance InformationThe Association of
v Pool & Spa Professionals®
RECEIVED
DEC 14 2021
�L
�0 �e-i
ANSVAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATI FNTIAL SWIMMING POOL
PROJECT NAME:
AND ADDRESS
HO-WINKLAREK
CONTRACTOR NAME
AND ADDRESS:
OASIS P OLS & SPAS OF THE THE
2986 Bent Pine Dr
665 4TH STREET
Ft Pierce FL
VERO BEACH, FLORIDA 32962
OWNER: Paul Wlnklarek
CONTRACTOR PHONE: 772-226-7196
DATE: 11-8-21
�+
I his information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and sp;'
Professionals (APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only. Contractors should acquire and comply
with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org.
1. §5.2.1: Calculated pool volume
a. Gallons: 7751: or
b. Calculated Gallons: (surface area) X
2. §5.2.1: Calculated maximum filtration flow rate
(Pool volume _ 360 or 36gpm whichever is larger)
(average depth) X 7.48 (gal/ft"3) =_0
3. §5.2.2: Auxiliary Pool Load: Yes, ✓ No?
(Enter the highest "auxiliary pool load" to be powered by the swimming pool filtration pump. Do not add auxiliary
pool load flow rates together, only the highest is used.)
4. Calculated maximum flow rate
(Item 2 or item 3, whichever is larger.)
S. §5.5.1: Pipe sizing:
a. Minimum suction pipe diameter
(Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than item 4.)
b. Minimum suction branch pipe diameter
LC alculate: Item 4. 36 (torn) + Branch Pipes f (quantity) = branch Flow rate 36 (tpm).
Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated
suction branch flow rate.)
c. Minimum return pipe diameter
(Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 4.)
d. Minimum return branch pipe diameter
(Calculate: Item 4. 36 (qpm) + Branch Pipes f (auantity) = branch Flow rate 36 (gpm).
Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated
return branch flow rate.)
6. §5.4.1: Filter type and size:
a. Filter type: (Cartridge, DE, Sand)
b. Minimum filter area
(Calculate, item 4. 36 (apm) + filter factor 0.375 1
Filterfactors: Cartridge=0.375, Sand=15, Diatomaceous Earth=2
7. §5.4.2: Backwash valve: Yes, ✓ No?
(When using a backwash valve, enter result of item 5c or 2 inches whichever is larger)
Table 1
I Pipe Size:
1.5"
2"
2.5"
3"
13.5"
4"
5"
I 6"
( Nomli al GPM @ 6 fps
38
63
90
138
185
238
374
540
L Nominal GPM @ 8 fps
51
84
1 119
184
247
317
499
720
8. Pump selection:
§5.3.2.1: Pools 17,000 gallons or less, select pump* from the database with a Curve -A gpm flow equal to item 2 or less.
§5.3.2.2: Pools 17,001 gallons or more, select pump* from the database with a Curve-C gpm flow equal to item 2 or less. *Multi -
speed pumps must have one speed listed that satisfies this requirement.
a. Pump model
b. Pump flow
(§5.3.2.1, 5.3.2.2: Applicable Curve A or C gpm flow listed in database)
1.7751
2.
36 gpm
3.
gpm
4.
36
gpm
5a.
1.5
inches
5b.
1.5
inches
5c.
1.5
inches
5d.
1.5
inches
6b.
96
sq. ft.
7.
2.0
inches
•
8b.
98
cipm
4/5/12
ANSI/APSP/ICC- 15 Standard Writing Committee Form
1of2
ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
Component
Section
Requirements
Check
Heaters
4.4.1.1
Heater has no pilot light
✓
4.4.1.2
Readily accessible on -off switch mounted outside of the heater
4.3.1.3
No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation,
or for pool with 60% of documented pool heating from on -site solar or recovered energy.
4.3.2
Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0
Pool systems
5.1.1
Pool filter pump listed in database
5.3.1
Pool filter pump with total horsepower 1.0 or more is multi -speed
5.3.3
Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary
pool loads are operating within 24 hours and programmed with temporary override capability for
servicing.
5.3.4
Single -speed pump controller capable of operating pump during off-peak electric demand.
5.5.2
Pipe before pump has at least 4 diameters of straight pipe.
5.5.3
System installed with solar, or setup for the future addition of solar heating equipment by
installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or
built-up connections, or dedicated pipe to and from the pool.
5.5.6
Directional inlets for mixing pool water.
4/5/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 2 of 2