HomeMy WebLinkAboutResidensial Swimming Pool SpecsGENERAL NOTES 1. For pool plan, size, deck, and special details, see Contractor's Pool Plan. 2. Pool Walls shall be 5" thick and Floors shall be 6" thick and shall be pneumatically cYr applied Concrete with a Compressive Strength of 3,000 psi in 28 days. Concrete* Decks shall be 2,500 psi. Concrete construction will conform to ACI Standard 318. sx'' 3. All Pool design, construction and workmanship shall be in conformity with the requirements of Florida Building Code, 7th Edition, 2020 (FBC) Accessibility; FBC Building; FBC Residential, and; ANSI/APSPACC-3, ANSI/APSP/ICC-4, ANSI/APSP/ICC-5;ANSI/APSP/ICC-6 and ANSI/APSP-7; ANSI/APSP-15 and the Adopted National Electric Code 2017 (NEC) and Chapter 45 of the Florida Building Code, 7 th Edition, 2020, Residential. 4. All Pool Piping to be Schedule 40 PVC, bearing the mark of NSF Approval unless otherwise noted. 5. Al[ Reinforcing Steel to conform to ASTM 615, Grade 40. Reinforcing shall be #3 bars at 12" on center in each direction, w/ 15" lap joints in walls and floors up to 6'. Where the pool depth is over 6ft (measured vertically down from the _Waterline), use #3 bars at 6" on center in each direction in the areas that exceed 6ft in depth. 6" WtLIGHT I COPING WATER LINE POOL LINE ,r, DRAIN GRATE / COVER STEPS MUST CONFORM TO ASME / ANSI Al12.19.8 j w OR ANY SUCCESSOR En STANDARD POOL STEPS: ' RISERS: 12" MAX. � DUAL SUCTION OUTLET AND APPROVED GRATE/COVER TREAD: 10' MIN. (240 SQ. IN. MIN.) WITH S-O" OF SEPARATION CENTER LINE TO CENTER LINE OR APPROVED CHANNEL DRAIN SET INTO R OF POOL SECTION POOLS DEEPEST POINT EEL GRID AT THE (LONGITUDINAL) CONCRETE DECK (OPTIONAL) W/ SLIP RESISTANT TOPPING ON COMPACTED GROUND W/ ALL ORGANIC MATERIAL REMOVED. 4" NOM. THK. W/ FIBER MESH OR 5" NOM. THK. W/ #3 REBARS. f' If Concrete is cast against Bare Earth without a Separation Barrier, the minimum 1-#3 BAR CONT. IN 5" THK WALL. 4'-0" JUNCTION BOX cover shall be 3". With a Barrier (Steeltex) between Concrete and Earth, the (USE 2-#3 BARS CONT. IN 8"x8" (BY OTHERS) co WATER LINE 14" MIN. 18" MAX. S01 LS (NO VOIDS) SWIM -OUT DETAIL DECK OVER POUR OR �I BRICK COPING minimum cover shall be 1Y2". Min, cover shall be 1 1/2" between steel and main drains and piping. BOND MS 6. All Metallic Pool Fittings within 5' of the inside wall and deck reinforcing steel to be °O TO TRANSFORMER 6" OF " 1-#3 BAR bonded to the Pool Reinforcing Steel with #8 AWG Copper Wire. The #8 Copper vWATER (BY OTHERS) WATER CONT. IN 5" 2-#3 BARS Wire to be run internally and externally with the NEC approved PVC Light Conduit LINE z 0 w CONT. IN TINES THICK BOND form the Light Niche to the Junction Box. Completion of the pool grounding to the J 8"X8" BOND BEAM Electrical Panel Ground to be by Electrician. BEAM 7. Bond all Sheathed Cables, Raceways, Metal Piping and all Fixed Metal Parts not separated by a permanent barrier, if within 5'-0" Horizontally from Water and MARBLE U.L APPROVED LIGHT IN COMPLIANCE 12'-0" Vertically of Maximum Water Level. PLASTER WITH LATEST ADOPTED NEC MIN. 1Y" COVER _ 8. Equipotential Bonding to be accomplished in accordance with Article 680 of the FINISH OVER ALL BARS Adopted National Electrical Code 2017 (NEC). (SEE NOTE #5) 9. Pool or Patio shall bear only on Rock or Clean Sand, which shall be compacted to provide a Structurally Safe Bearing Capacity. Any Unsuitable Material encountered in ALTERNATE BEAM excavation shall be removed in its entirety and the area shall be backfilled with STEELTEX ( OPTIONAL) acceptable material and properly compacted. Where unsuitable Material cannot be #3 BARS @ 12" O.C. EACH WAY removed, the pool must be redesigned. POOL STRUCTURAL DETAILS 10. The Contractor must protect Existing Structures from failure by acceptable methods DISTANCE LESS if required. The Engineer accepts no responsibility for the safety of Existing VARIES 18" 1 THAN 1 ON 1 + 1 Structures. COPING 11 The Design Engineer assumes no res onsibility for pool construction in Easements or SEE SEAT Required Setback areas. Pool Contractor and/or Owner shall verify the layout and all dimesions shown to construction. WATER PLAN JETS MAY RUNS �� '? HORIZONTALL WATER LIN'4` E prior FINE 12. Contractor shall determine the location of all Utilities in relation to the Pool and its WITHIN WALL 5 #3 BARS @ 6" Equipment and ensure minimum clearances in accordance with Local Regulations THERAPY O.C. EACH WAY and Ordinances. LINES 13. Contractor shall provide adequate Temporary Fencing around the construction area ao 4" 6" WALL - 14. to prevent unauthorized entry into the Pool Area. If a water supply is provided, a minimum 3" Atmospheric Break will be provided. RETURN .-:;.; .: i° t LINES THICKNESS MARBLE-- 15. All Structural, Filtration and Electrical details outlined in these drawings also relate GUNITE PLASTER to Spa Construction. #3 BARS @ REBOUND FINISH 16. All Pool and Spa Heaters shall be equipped with an On/Off Switch mounted for 12" O.C.E.W. RAINS AND DRAIN GRATE / COVER easy access to allow the Heater to be Shut Off without adjusting the Thermostat TO COMPLY WITH ASME /ANSI Al12.19.8 - settings and to allow restarting without relighting the Pilot Light. OR ANY SUCCESSOR STANDARD 17. WARNING! To empty the Pool for any reason, the Hydrostatic Uplift Pressure must SPA STRUCTURAL DETAILS TYPICAL WALL AND be eliminated. The Owner must consult a Contractor experienced in eliminating Uplift Pressure. 1 MAIN DRAIN LINE 2 SKIMMER LINE E 3 WASTE LINE D 3 4 RETURN LINE 5 PRESSURE CLEANING C LINE (OPTIONAL) A HAIR & LINT STRAINER 5 B B RECIRCULATION PUMP 4 C FILTER A D IN -LINE CHLORINATOR (OPTIONAL) E HEATER (OPTIONAL) FILTER SYSTEM SPILLWAY PER CONTRACTORS POOL PLAN FLOOR WITHIN RAISED SPA WALLS THICKER THAN 10' SHALL ANGLE OF REPOSE HAVE 2 MATS OF STEEL-#3 BARS @ 12" O.C.E.W. �� --WATERLINE 11LES INTERIOR POOL FINISH ' -1-#3 REBAR @ 12" O.C.E.W. RAISED SPA DETAIL FINISH DETAIL NEW OR STRUCTURE LADDERS ARE TO BE CROSS BRACED PER ESCUTCHEON MANUFACTURERS SPECS PLATE S.S. LADDER 00 POOL _ DECK W WATER 1— RESISTANT ISLIP JOINTS AS WEDGE REQUIRED TREAD SURFACE ANCHOR ADDITIONAL CONCRETE AS REQUIRED FOR 3" MIN. TO 6" MAX ' ' STURDY INSTALLATION BETWEEN TREAD AND POOL WALL #8 BARE, SOLID, COPPER RUBBER BUMPER CONDUCTOR TO SHELL REINFORCING TYPICAL LADDER DETAIL f #8 AWG COPPER WIRE LINE RECEIVED DEC 14 2021 St. Lucie County Permitting CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6" ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED TO 6" THICKNES! THE STEEL MAT AND THICKER SHELL WALL SHALL EXTEND ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED AS DETERMINED BY THE 1 ON 1 + 1 METHOD. PLAN EXPIRES 1 YEAR FROM SIGNATURE DATE OR ON THE \ FF� JTIIMfi PATE OF A MAJOR CODE CHANGE. �.•.• �EIVs o.�� DEC 10 021 NO. 32046 STATE OF .•"` ���\ /,l11Z//yy`y�;10.1'n Skilo Engineering Services, Inc. Larry B. Schnaper, PE - FL PE NO. 32046 2431 Aloma Ave., Ste.124 NTS Winter Park, FL 32792 (407) 275-1099 TIME TO SERVICE CLOCK SPST TOGGLE W.P.- SWITCH DISC. 4'-0" JUNCTION 12V POOL BOX TRANS. DECK co ' ALL ELECTRICAL WORK SHALL CONFORM WITH ART. 680 OF THE 3 #12 IN Y2" LATEST ADAPTED NEC. CONDUIT U.L APPROVED LIGHT IN COMPLIANCE WITH LATEST ADOPTED NEC ELECTRICAL DIAGRAM REVIEWED FOR CODE COMPLIANCE sr. LUCIE %.VWCOUNTY Bor OASIS :POOLS &SPAS OF THE. TREASURE COAST WC_ fi65:�4TH ST VEMBEACH FL -32900 RESIDENTIAL SWIMMING POOL SPECIFICATION FOR: WINKLAREK RESIDENCE 2986 BENT PINE DR FORT PIERCE FL 34951 • TURNDOWN NOTES COMPACTED 1. Detail is based on NO surcharge behind the Turndown and the Ground away from SUBGRADE the Turndown is Level (>4 to 1). Turndown may abut Ribbon Footer and be tied s into Footer if Appropriate, with #3 Rebar. 2. Turndown shall bear on Rock, Clean Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling 1—#5 BAR CONTINUOUS — or Shifting. 3. All Reinforcing Steel is to Conform to ASTM 615, Grade 40. REFER TO NOTE 7: 4"0 CONCRETE PILASTER 4. Concrete shall contain Fiber Mesh and have a 28 Day Compressive Strength of AT 5'-0" ON CENTER WITH 2,500 PSI. 1—#3 BAR VERTICALLY 5. All Construction to Conform to Florida Building Code, 7th -Edition, 2020, FBC Building and FBC Residential. 6. Refer to Contractor's Plan on file with the Building Department for Details on Turndown Location. 7. If the Base of the Turndown does not extend into the Old (Existing) Ground, a 4"0 Pilaster will be required every 5'-0" that will be either 2'-0" into the Ground or to 6" into the Indigenous Material, Whichever is Deeper. The Pilaster will have a #3 Rebar tied into the #5 Rebar in the base of the Vertical Pour. 8. A Deck Turndown is NOT intended to be a substatute for a Retaining Wall. If the Vertical Dimension from the Top of the Concrete Deck to the Old (Existing) Ground reaches 36" for a 6" Turndown, 42" for a 12" Turndown, 48" for a 18" turndown, 54" for a 24" Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown should not be used. 9. For a Paver Deck, if the Vertical Dimension from the Top of the Deck to the Old (Existing) Ground reaches 24" for a 6" Turndown, 30" for a 12" Turndown, 36" for a 18" Turndown, 42" for a 24" Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown shall not be used. 10. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must coordinate Design and Construction of the Turndown Requirements with the Screen Contractor to Ensure it meets their Requirements. FOOTER NOTES 1. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must Coordinate Design and Construction of any required Footer with the Screen Contractor. 2. Footer shall bear on Rock, Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling or Shifting. 3. Concrete shall have a 28 Day Compressive Strength of 2,500 PSI with Fiber Mesh or 64-1000 W.W. Mesh. 4. (3) #3 Rebars is Equivalent to (1) #5 Rebar. 5. Paver or Travertine deck may be placed over the top of the Footer or abutting the side of the footer. CONCRETE POOL DECK 1—#3 BAR CONTINUOUS r-1—#5 BAR VERTICALLY AT 36" ON CENTER N o PROPOSED FINISHED ~ GRADE (COMPACTED) I 4 MIN. rEXISTING N, I GRADE CONCRETE DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK GRADE R z d. 1=1 11=1 11=11=1 11 COMPACTED PAVER """ DECK BASE MATERIAL POOL C REFER TO NOTE 7: 8"� 4"0 CONCRETE PILASTER AT 5'-0" ON CENTER WITHI. 1—#3 BAR VERTICALLY —#3 BAR CONTINUOUS -1—#5 BAR VERTICALLY AT 36" ON CENTER A = 6" to 24" B = Y4 x A (4.5" to 1811 PROPOSED FINISHED GRADE (COMPACTED) m 4. MIN. ccEXISTING N, rGRADE I —I I �� Pi. 64- ��io z II=III— � 4n PA VER DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK GRADE g" 1'�'�145 BAR F'—�1 CONTINUOUS NO FOOTER 8" x 8" FOOTER PROPOSED CONCRETE PROPOSED CONCRETE FINISHED POOL DECK FINISHED POOL DECK GRADE GRADE z —I I, ..... . I —III ' N —I I,Z-r— W 12" 2—#5 BARS 2—#5 BARS CONTINUOUS 12" CONTINUOUS 8" x 12" FOOTER 12" x 12" FOOTER BRICK PAVER OR TRAVERTINE BRICK PAVER OR TRAVERTINE PROPOSED POOL DECK PROPOSED POOL DECK FINISHED FINISHED GRADE _ t GRADE I - BRICK PAVER OR TRAVERTINE POOL DECK PAVER SECURED TO TOP OF TURNDOWN BY PAVER INDUSTRY STANDARDS SEE PAVER DECK TURNDOWN DETAIL FOR INFORMATION NOT SHOWN ALTERNATE PAVER ON TURNDOWN DRAINAGE SWALE� 1—#3 BAR CONTINUOUS y • 1—#5 BAR VERTICALLY D' AT 36" ON CENTER a 1—#5 BAR CONTINUOUS °s • A = 6" to 24" DECK B = x A (4.5" to 18'� >• PAVER, TRAVERTINE, G OR CONCRETE O° • -PACTED BASE • , MATERIAL FOR PAVER ... OR TRAVERTINE DECK 8 COMPACTED SUBGRADE TURN UP CURB DETAIL • PLAN EXPIRES 1 YEAR FROM SIGNATURE DATE OR ON THE D. . 2—#5 BARS 8" 1—#5 BAR EFFECTIVE DATE OF A MAJOR CODE CHANGE. 12" CONTINUOUS CONTINUOUS ,\\X111t+lurri�,��� " " " „ \�\\\`_ 3 Sc�y'i�, DEC 10 2021 12 x 12 FOOTER 8 x 8 FOOTER .•e• '�f WZ PA VER DECK W/ PA VER DECK ��Q'�,rcEvF ���'% TRAVERTINE OR OPTIONAL EDGE BRICK PAVER TRAVERTINE OR RESTRAINT PROPOSEDA POOL DECK BRICK PAVER PROPOSED FINISHED POOL DECK FINISHED GRADE GRADE COMPACTED i i COMPACTED CONCRETE SUBGRADE PAVER BASE PAVERS ON CONCRETE DECK PA VER DECK WITHOUT FOOTER CONCRETE DECK MAY BE CONSTRUCTED WITH A FOOTER OPTIONAL: CONCRETE OR PLASTIC EDGE RESTRAINT MAY BE OR WITHOUT A FOOTER ADDED TO THE DECK PERIMETER AS NEEDED TO SECURE PAVERS PROPOSED FINISHED GRADE - I BRICK PAVER OR TRAVERTINE POOL DECK — NO. 32046 STATE OF a i i I —III- e 12" Z—fCONTISNUOUS /'N L �\\\ 8" x 12" FOOTER ry B. Engipneering Services, Inc. Lar B. Schna er, PE - FL PE NO. 32046 W/ PAVER DECK 24Aloma Ave., Ste.1 NTS _ Winter Parkk,, 2 FL 32792 (407) 75-1099 REVIEWED FOR 30E COMPLIANCE CIE COUNTY BOCC OASIS POOL'S A. SPAS OF THE TREASUR€ COAST ING: 665 4TH sT '11ER0 SEdGH FL 329Q0; DECK, FOOTER, AND TURNDOWN SPECIFICATION SHEET FOR: WINKLAREK RESIDENCE 2986 BENT PINE DR FORT PIERCE FL 349511