HomeMy WebLinkAboutTDH Calculator►�ji"'�1SENlAIR
STEP 1
POOL SPECIFICATIONS
STEP 3 OF 3: TDH CALCULATION
TD_ H CALCULATOR
STEP 2
SELECT EQUIPMENT
Pool Specifications
Pool Volume (gallons): 7751.00 gallons Suction Lift: 1.50 ft
Turn Over (hoursh 6.00 hours
r^
j Filtration Flow Rate: 36.00 GPM i Maximum Flow Rate 49.30 GPM
sele[fed"baffi6 l6nts -. _. s' w, <..,.. k .;v.,Y+: ..'?_.. �s•'.�':v?_ �z�r..r. ?fay :' »:�_.. _,,.�__ ,^'. =`~5, ;x`5���3:Tia r'.
SELECTION
QUANTITY
9
INTELLICHLOR IC - 20
1
2" X 2.5" 3 WAY VALVE
3
MAIN DRAIN
1
"tmnmuat
CLEAN AND CLEAR RP
1
ULTRATEMP
1
11NCH RETURN
3
NO IMAGE
AVAfLABLE
I
SELECTION MODEL QUANTITY ;{
1
n SUPERFLO VS 1
�q I
MAXIMUM PIPE VELOCITY (FT/SEC) SUCTION OUTLET 8
(CONSULT YOUR LOCAL CODE) DISCHARGE 8 II
I I
TOTAL PIPING LENGTHS (FT) INLET 120.00
DISCHARGE 128.00
SELECTION QUANTITY'
Aldpwiq 90 DEGREE ELBOW INLET 4
DISCHARGE 9
TEE BRANCH INLET 1
DISCHARGE 0
TEETHROUGH INLET O
DISCHARGE 2
P,EViEWE® FOR
CODE COMPLIANCE
ST. LUCIE COUNTY EOCC
RPM:
j REQUIRED MINIMUM PIPE SIZE
Inlet Piping: 1.50 Discharge Piping: 1.50
1
i PUMP RPM
Flow Rate at Selected Pump RPM. 49.30 Pump RPM: 3450
Head Loss at Selected Pump RPM: 63.23
I
BACK