HomeMy WebLinkAboutTDH Calculator►�ji"'�1SENlAIR STEP 1 POOL SPECIFICATIONS STEP 3 OF 3: TDH CALCULATION TD_ H CALCULATOR STEP 2 SELECT EQUIPMENT Pool Specifications Pool Volume (gallons): 7751.00 gallons Suction Lift: 1.50 ft Turn Over (hoursh 6.00 hours r^ j Filtration Flow Rate: 36.00 GPM i Maximum Flow Rate 49.30 GPM sele[fed"baffi6 l6nts -. _. s' w, <..,.. k .;v.,Y+: ..'?_.. �s•'.�':v?_ �z�r..r. ?fay :' »:�_.. _,,.�__ ,^'. =`~5, ;x`5���3:Tia r'. SELECTION QUANTITY 9 INTELLICHLOR IC - 20 1 2" X 2.5" 3 WAY VALVE 3 MAIN DRAIN 1 "tmnmuat CLEAN AND CLEAR RP 1 ULTRATEMP 1 11NCH RETURN 3 NO IMAGE AVAfLABLE I SELECTION MODEL QUANTITY ;{ 1 n SUPERFLO VS 1 �q I MAXIMUM PIPE VELOCITY (FT/SEC) SUCTION OUTLET 8 (CONSULT YOUR LOCAL CODE) DISCHARGE 8 II I I TOTAL PIPING LENGTHS (FT) INLET 120.00 DISCHARGE 128.00 SELECTION QUANTITY' Aldpwiq 90 DEGREE ELBOW INLET 4 DISCHARGE 9 TEE BRANCH INLET 1 DISCHARGE 0 TEETHROUGH INLET O DISCHARGE 2 P,EViEWE® FOR CODE COMPLIANCE ST. LUCIE COUNTY EOCC RPM: j REQUIRED MINIMUM PIPE SIZE Inlet Piping: 1.50 Discharge Piping: 1.50 1 i PUMP RPM Flow Rate at Selected Pump RPM. 49.30 Pump RPM: 3450 Head Loss at Selected Pump RPM: 63.23 I BACK