HomeMy WebLinkAboutAPPROVED, PV Plans Stamped - 123723_Rodriguez, TomasPV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------THIS PROJECT COMPLIES WITH THE FOLLOWING:2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)2017 NATIONAL ELECTRIC CODE (NEC)AS ADOPTED BY ST. LUCIE COUNTYSITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BSTRUCTURAL CALCULATIONSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACESITE LOCATIONGREG ALBRIGHTPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2017 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT.THIS SYSTEM IS DESIGNED FORWIND SPEED: 158 MPHCATEGORY C EXPOSURE MSPINVJBUMACSITE PLANSCALE: 1/16" = 1'-0"1PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------ROOF AREA: 2865 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERSUBPANELMAIN SERVICEPANELACJBINVSUBMSPGREG ALBRIGHT136'-9"109'-4"8'-6"45'-8"45'-0"25'-10"TOTAL ROOF AREA RIDGE SETBACK CALCS:TOTAL ROOF AREA: 2865 SQ FTSINGLE MODULE AREA: 20.9 SQ FTTOTAL NUMBER OF MODULES: 27TOTAL AREA OF MODULES: 564.30 SQ FTROOF COVERAGE: 19.70%FIRE SPRINKLERS : NOBOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10'THIS SYSTEM DESIGNED WITH:WIND SPEED: 158WIND EXPOSURE: CSNOW LOAD: 0DRIVEWAYNORTHEAST CAPRONA AVENUEROOF LINEPROPERTY LINE(E) MAIN SERVICE PANEL(N) 27 TRINA SOLAR: TSM-330PE14A(E) UTILITY METER(N) JUNCTION BOX(N) SOLAREDGE SE6000H-US [SI1]INVERTER WITH RAPID SHUTDOWN(N) UTILITY DISCONNECT EATON DG222URB(OR EQUIVALENT)Roof 2(hip roof) needs a blocking upgradeRefer to Structural Calculation for details MSPINVJBUMACPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------ROOF PLANSCALE: 3/32" = 1'-0"1NOTES:1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3. JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2865 SQ FTROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERSUBPANELMAIN SERVICEPANELACJBINVSUBMSPGREG ALBRIGHTFIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYS3'-0"3'-0"3'-0"(N) 27 TRINA SOLAR: TSM-330PE14AMODIFIED SETBACKS PROPOSED AT RIDGE:TOTAL ARRAY AREA = 564.3 SFTOTAL ROOF AREA = 2865 SFTOTAL ARRAY AREA AS A % TO ROOF AREA = 19.70%19.70% < 33%BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10'THIS SYSTEM DESIGNED WITH:WIND SPEED: 158WIND EXPOSURE: CSNOW LOAD: 0Roof 2(hip roof) needs a blocking upgradeRefer to Structural Calculation for detailsBy Yuri at 6:41:49 PM, 2/23/2022 ROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCH ARRAY PITCHAZIMUTHROOF AREAARRAY AREA11115°15°258°706 SQ FT229.9 SQ FT2515°15°348°341 SQ FT104.5 SQ FT31115°15°78°662 SQ FT229.9 SQ FTPV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------ROOF DETAILS:TOTAL ROOF AREA: 2865 SQ FTARRAY COVERAGE: 19.70%SYSTEM DISTRIBUTED WEIGHT: 2.37 LBSSFM INFINITY \ ROCKIT MICRORAIL POINT-LOAD: 12.64 LBSROOF DETAILSGREG ALBRIGHTRoof 2(hip roof) needs a blocking upgradeRefer to Structural Calculation for detailsBy Yuri at 6:41:51 PM, 2/23/2022 ROOF DECK /MEMBRANESLIDER AND TRIMRAILROOF ATTACHMENTBUILDING STRUCTURE5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHER2.5"TRIMRAIL2.5" MIN. EMBED.FLASHINGROOF / DECK MEMBRANESLIDERSBUILDING STRUCTURE5/16" STAINLESS STEELLAG BOLT ORSTRUCTURAL SCREWWITH 2-1/2" MIN.EMBEDMENT AND FLATWASHER2.5"MICRORAILFLASHING2.5" MIN. EMBED.TRINA SOLAR:TSM-330PE14ATRINA SOLAR:TSM-330PE14ASLIDERSMICRORAIL2.5" MIN. EMBED.5/16" STAINLESS STEEL LAGBOLT OR STRUCTURAL SCREWWITH 2-1/2" MIN. EMBEDMENTAND FLAT WASHERTRIMRAIL2.5" MIN. EMBED.FLASHINGFLASHINGSLIDER AND TRIMRAIL ROOFATTACHMENT2X4 TRUSS @ 24" O.C.ROOF / DECK MEMBRANE3" MIN.MAX5" .TRINA SOLAR: TSM-330PE14ASFM INFINITY \ ROCKIT RAIL-LESS RACKING SYSTEM(N)TRINA SOLAR: TSM-330PE14A2X4 TRUSS @ 24" O.C.ROOF ATTACHMENT4'ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------MOUNTING DETAILSGREG ALBRIGHTMAX ATTACHMENT SPAN - 4'Roof 2(hip roof) needs a blocking upgradeRefer to Structural Calculation for detailsBy Yuri at 6:41:53 PM, 2/23/2022 SOLAREDGE P401 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P401POWER OPTIMIZERS2 - #10 AWG,PV WIRE17 TRINA SOLAR: TSM-330PE14A10 TRINA SOLAR: TSM-330PE14A4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITTO OTHERLOADSUM(E) 150A / 2P MAINBREAKER(END FED)(N) 100A / 2PSUBPANELBREAKER(E) 150A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZTO UTILITYUNDERGROUNDFEED(N) 200A MINIMUM RATEDSUB PANEL1PH, 120/240V 60HZ(N) 35A / 2PPV BREAKEREXISTING WIRE RUNTHROUGH CONDUIT(N) 150A RATEDMAIN BREAKER(END FED)(E) UTILITY METER3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A RATEDAC DISCONNECTEATON DG222URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) SOLAREDGESE6000H-US [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 25.00A @ 240V25.00X1.25=31.25AMPS35A BREAKER - OKSEE 705.12 OF 2017 NEC150X1.20=180180-150=30A ALLOWABLE BACKFEEDPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------THREE LINE DIAGRAMGREG ALBRIGHTPV SYSTEM8.910 kW-DC6.000 kW-AC PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZERROOF / FREE-AIR2104011.601140.0014.502DCOPTIMIZERTOJUNCTION BOXROOF / FREE-AIR2104015.001140.0018.753DCJUNCTION BOXTOINVERTEREXTERIOR WALL4104015.0010.832.0018.754ACINVERTERTOAC DISCONNECTEXTERIOR WALL385525.001155.0031.255ACAC DISCONNECTTOPOIEXTERIOR WALL385525.001155.0031.256ACSUBPANELTOMSPEXTERIOR WALL31/0170150.0011170.00150.00CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------QTY.PARTPART #DESCRIPTION27MODULES113-330TRINA SOLAR: TSM-330PE14A27OPTIMIZERS130-401SOLAREDGE P401 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOX480-276600VDC NEMA 3R UL LISTED JUNCTION BOX2CONNECTORS240-300STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2CONNECTORS240-301STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTER120-601SOLAREDGE SE6000H-US [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1AC DISCONNECT321-06060A RATED 240VAC NEMA 3R UL LISTED106ROOF ATTACHMENT 1261 -602SFM INFINITY \ ROCKIT MICRORAIL20SFM TRIM 1241-253FLASHKIT SFM / ROCK-IT TRIM COMP DARK51SFM SLIDER 1261-603FLASHKIT SFM / ROCK-IT SLIDER COMP DARK15BONDING CLAMP 1221-100N/S BONDING CLAMP6BONDING CLAMP 1241-404TRIM BONDING CLAMP29MOUNT ASSEMBLY 1241-405MLPE MOUNT ASSY16SFM SPLICE 1261-604SFM / ROCK-IT SPLICE4SFM ATTACHED SPLICE 1211-101ATTACHED SPLICE 8 INCH23TRIMRAIL 1261-606TRIMRAIL UNIV CLIP W/ HDW7TRIM SPLICE 1261-605TRIM SPLICE DRK12TRIMRAIL 1211-115TRIMRAIL UNIV DRK27GROUND LUG 1260-585ILSCO GROUND LUG27TRIM END CAPS 1221-200UNIRAC SFM / ROCK-IT TRIM END CAPSBREAKER SIZES:35A PV BREAKERSERVICE LIST:TRUEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.54705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE.TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAY690.56(C)(1)(A)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC 690.15, 690.54PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 25.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)INVERTERARRAYJ/BDC"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.13 (B)690.53NEC 690.31(G)(3) & (4)PMPV METERSOLAR ELECTRICPV PANELSPV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 16.5AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15ATURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNENTIRE PV SYSTEMNFPA 11.12.2.1.1.1.1SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION.ONLY CONDUCTORS INSIDEBUILDING OR OFF THEROOF WILL SHUT DOWNNFPA 11.12.2.1.1.1.2SOLAR ELECTRICPV PANELSEMERGENCY RESPONDERTHIS SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWN"WARNING"PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESPV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNNORTHEAST CAPRONA AVENUEMAIN SERVICE PANELAC DISCONNECTINVERTER EQUIPPEDWITH RAPID SHUTDOWNUTILITY METER27 PV MODULES 123456789101-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT SAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------SAFETY PLANGREG ALBRIGHTNORTHEAST CAPRONA AVENUE JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:CERTIFIED ELECTRICAL CONTRACTOREC13008056FREEDOM FOREVER LLC2619 CONSULATE DR SUITE 800, ORLANDO,FL 32819Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:F123723DESIGNED BY:H.D.CLIENT:TOMAS RODRIGUEZ196 NORTHEAST CAPRONA AVENUE, PORTST. LUCIE, FL 34983AHJ: ST. LUCIE COUNTYUTILITY: FPL - FLORIDA POWER & LIGHTPHONE: (561) 727-0317SYSTEM:SYSTEM SIZE (DC): 27 X 330 = 8.910 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 27 X TRINA SOLAR: TSM-330PE14AOPTIMIZERS: 27 X SOLAREDGE P401INVERTER: SOLAREDGE SE6000H-US [SI1]DATE:2/23/2022---------SAFETY PLANGREG ALBRIGHT 0~+5W POSITIVE POWER TOLERANCE 72 CELL MULTICRYSTALLINE MODULE 320-340W POWER OUTPUT RANGE 17.5% MAXIMUM EFFICIENCY IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System ISO14064: Greenhouse gases Emissions Verication OHSAS 18001: Occupation Health and Safety Management System Comprehensive Products And System Certicates Mono Multi Solutions Certied to withstand the most challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hail stones at 97 km/h THE FRAMED 72-CELL MODULE (1500V) 10 Year Product Warranty · 25 Year Linear Power Warranty Guaranteed PowerAdditional val u e f r o m T r i n a S o l a r ’ s l i n e a r w a r r a n t y 80% 90% 100%97.5% Years 5 10 15 20 25 LINEAR PERFORMANCE WARRANTY Ideal for large scale installations • Reduce BOS cost by connecting more modules in a string • 1500V UL/1500V IEC certied One of the industry’s most trusted modules • Field proven performance Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certication requirements • 100% EL double inspection EU-28 WEEECOMPLIANTRECYCLABLEPACKAGING Founded in 1997, Trina Solar is the world's leading comprehensive solutions provider for solar energy. we believe close cooperation with our partners is critical to success. Trina Solar now distributes its PV products to over 60 countries all over the world. Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually benecial collaboration with installers, developers, distributors and other partners.TO P P E RFORMER PV MODULE RELIABILIT Y SCORE CA RD 2017 Standard Step WarrantyTrina Linear Warranty FRAMED 72-CELL MODULE (1500V) TSM-PE14A 320-340W PRODUCTS POWER RANGE CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. © 2017 Trina Solar Limited. All rights reserved. Specications included in this datasheet are subject to change without notice. Version number: TSM_EN_2018_B www.trinasolar.com I-V CURVES OF PV MODULE(335W) 0 10 20 30 40 50 Voltage(V)Current (A)1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 1000W/m 800W/m 600W/m 400W/m 200W/m P-V CURVES OF PV MODULE(335W) 0 10 20 30 40 50 Voltage(V)Power (W)50 100 150 200 250 350 300 1000W/m 800W/m 600W/m 400W/m 200W/m DIMENSIONS OF PV MODULE(mm/inches) (A-A) (DO NOT connect Fuse in Combiner Box with two or more strings in parallel connection) 44°C (±2°C) - 0.41%/°C - 0.32%/°C 0.05%/°C TEMPERATURE RATINGS NOCT(Nominal Operating Cell Temperature) Temperature Coecient of P MAX Temperature Coecient of V OC Temperature Coecient of I SC MAXIMUM RATINGS Operational Temperature Maximum System Voltage Max Series Fuse Rating -40~+85°C 1500V DC (IEC) 1500V DC (UL) 15A (Please refer to product warranty for details) WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Warranty PACKAGING CONFIGURATION Modules per box: 27 pieces Modules per 40’ container: 648 pieces NOCT: Irradiance at 800W/m, Ambient Temperature 20°C, Wind Speed 1m/s. ELECTRICAL DATA (NOCT) 241 34.4 7.00 42.2 7.42 245 34.6 7.08 42.4 7.49 252 35.0 7.21 42.8 7.60 Maximum Power-PMAX (Wp) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) 237 34.3 6.92 42.1 7.39 ELECTRICAL DATA (STC) STC: Irradiance 1000W/m, Cell Temperature 25°C, Air Mass AM1.5.*Measuring tolerance: ±3%. 340 37.8 8.99 46.2 9.42 17.5 330 37.4 8.83 45.8 9.28 17.0 320 37.1 8.63 45.5 9.15 16.5 325 37.2 8.73 45.6 9.19 16.7 Solar Cells Cell Orientation Module Dimensions Weight Glass Backsheet Frame J-Box Cables Connector MECHANICAL DATA Multicrystalline 156.75 × 156.75 mm (6 inches) 72 cells (6 × 12) 1960 × 992 × 40 mm (77.2 × 39.1 × 1.57 inches) 22.5 kg (49.6 lb) 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass White Silver Anodized Aluminium Alloy IP 67 or IP 68 rated Photovoltaic Technology Cable 4.0mm (0.006 inches), 1200 mm (47.2 inches) Trina TS4 Type 1 or Type 2 335 37.6 8.91 46.0 9.35 17.2 249 34.8 7.14 42.6 7.55 Peak Power Watts-PMAX (Wp)* Power Output Tolerance-PMAX (W) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Module Eciency m (%) 0 ~ +5 Silicon Sealant Laminate Frame Back View40/1.57 992/39.1 947/37.3 950/37.4 180/7.1 1300/51.2400/15.7330/13.06-Ø 4.3 Grounding Hole 4-Ø 9x14 Installing Hole 4-Ø 7x10 Installing Hole1960/77.212-Drain Hole 1200±10/47.2±0.39Junction Box Nameplate AA 180/7.1 150/5.935/1.3840/1.5711/0.43 Fire Type POWER OPTIMIZERPower Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 solaredge.com PV power optimization at the module level Specifically designed to work with SolarEdge inverters Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Up to 25% more energy Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Fast installation with a single bolt Flexible system design for maximum space utilization 25 YEARWARRANTY Power Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 06/2020/V02/ENG ROW. Subject to change without notice. (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed. (2) For other connector types please contact SolarEdge. (3) For dual version for parallel connection of two modules use the P485. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module is supported. When connecting a single module, seal the unused input connectors using the supplied pair of seals. OPTIMIZER MODEL (typical module compatibilty) P370 (60/72 Cell modules) P401 (For high power 60/72-cell modules) P404 (for 60/72- cell short strings) P405 (for high-voltage modules) P485 (for high-voltage modules) P500 (for 96-cell modules) P505 (for higher current modules) UNIT INPUT Rated Input DC Power(1)370 400 405 405 485 500 505 W Absolute Maximum Input Voltage (Voc at lowest temperature)60 80 125 80 83 Vdc MPPT Operating Range 8 - 60 12.5 - 80 12.5 - 105 8 - 80 12.5-83 Vdc Maximum Short Circuit Current (Isc)11 11.75 11 10.1 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x29.5 / 5.08 x6.02 x 1.16 129 x 89 x 42.5 / 5.1 x 3.5 x 1.7 129 x 90 x 49.5 / 5.1 x 3.5 x 1.9 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)655 / 1.5 775 / 1.7 845 / 1.9 750 / 1.7 1064 / 2.3 gr / lb Input Connector MC4(2)Single or Dual MC4(2)(3)MC4(2) Input Wire Length 0.16 / 0.52 m / ft Output Connector MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 Relative Humidity 0 - 100 % PV SYSTEM DESIGN USING ASOLAREDGE INVERTER(4)(5) SINGLE PHASEHD-WAVE SINGLE PHASE THREE PHASE THREE PHASE FOR 277/480V GRID Minimum String Length (Power Optimizers) P370, P401, P500(6)8 16 18 P404, P405, P485, P505 6 14 (13 with SE3K(7))14 Maximum String Length (Power Optimizers)25 50 50 Maximum Power per String 5700 5250 11250(8)12750(9)W Parallel Strings of Different Lengths or Orientations Yes (4) It is not allowed to mix P404/P405/P485/P505 with P370/P401/P500/P600/P650/P730/P801/P800p/P850/P950 in one string. (5) For SE15k and above, the minimum DC power should be 11KW. (6) The P370/P401/P500 cannot be used with the SE3K three phase inverter (available in some countries; refer to the three phase inverter SE3K-SE10K datasheet). (7) Exactly 10 when using SE3K-RW010BNN4 (8) For the 230/400V grid: it is allowed to install up to 13,500W per string when the maximum power diference between each string is 2,000W. (9)For the 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power diference between each string is 2,000W Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics.SUPERIOR PERFORMANCEEnhance your business with two installs per dayand 30% less cost.EASY INSTALLATIONPre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERREDMore than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand.SFM INFINITYFRONT TRIM AND END CAPSUNIVERSAL COMPONENTSFIT 32 – 40MM MODULESEOWNERPREFERRED25 YEAR FULL-SYSTEM WARRANTYONE SKU FITS 32 TO 40mmREVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702REVOLUTIONIZING ROOFTOP SOLARFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702SFM INFINITYDESIGN GUIDELINESAPPLICATION GUIDEWhile you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits.When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments.DEFAULT TO LANDSCAPESFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects.MIX MODULE ORIENTATIONSVisit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY.CONSULT THE QUICK TIPS VIDEOSQuick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents.DESIGN IN U-BUILDERU-Builder: https://design.unirac.com/ The RockIt system is the industry’s premier rail-less PV racking system for composition shingle, tile, and metal roofs. Designed in conjunction with the needs of installers, RockIt quickly & easily installs with a single tool. Featuring an easy-to-position alignment slide and a top-down leveling system, RockIt is logistically intelligent with no need to ship or transport long rails. Components are DYDLODEOHLQDEODFNȴQLVKWKDWFRPSOHPHQWVERWKFRPPHUFLDOand residential applications. Conforms to UL 2703. FEATURES & BENEFITS• Patented watertight technology • Fully integrated bonding• Top-down leveling system•North-South adjustability• Single tool installCOMPLETE RAIL-LESS RACKING SYSTEMSTREAMLINED INSTALLATION WITH MINIMAL ROOF PENETRATIONSComposition Shingle, Tile, MetalRail-LessStructural-Attach Direct-AttachECOFASTENSOLAR.COMFRAME MLPE MOUNT Attaches and fully bonds MLPE’s (Module Level Power Electronics) to the module frame with a single bolt clip.COUPLING The fast installing RockIt Coupling easily attaches to the module frame to bridge the gaps between modules. ROCKIT SLIDEAvailable in three variations, the RockIt Slide allows installation on composition shingle, tile, and metal roofs.SKIRTThe sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically-pleasing finishing touch.ROCKIT MOUNTFeaturing integrated bonding pins, the RockIt Mount connects to the Slide and can easily be positioned for fast installation. Features top-down leveling. DQD 507 Rev. 2016-02-18 Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 (266909) Project: 70185553 Date Issued: 2018-10-08 Issued to: Unirac 1411 Broadway NE Albuquerque, New Mexico 87102 USA Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES- PHOTOVOLTAICS--PV Racking CLASS - C531382 - POWER SUPPLIES- PHOTOVOLTAICS-PV Racking and clamping systems-Certified to US Standards Models: SM SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. SOLARMOUNT The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, or 10 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. Certificate: 70131735 Project: 70185553 Master Contract: 266909 Date Issued: 2018-10-08 DQD 507 Rev. 2016-02-18 Page 2 The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. Mechanical ratings: Downward Design Load (lb/ft²) 113.4 Upward Design Load (lb/ft²) 50.4 Down-Slope Load (lb/ft²) 14.7 Conditions of acceptability: Installation is subject to acceptance of the local inspection authorities having jurisdiction. The certification of these products relates only to the methods of installation, bonding, and grounding as outlined in the Installation Manual for each product. Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPLICABLE REQUIREMENTS UL 2703-1st Edition - Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. LTR AE-001-2012 - List of Technical Requirements for Photovoltaic Module and Panel racking Systems MARKINGS The manufacturer is required to apply the following markings: x Products shall be marked with the markings specified by the particular product standard. x Products certified for Canada shall have all Caution and Warning markings in both English and French. Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 1 of 3 GFT-OP-10a Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: x Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. x Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: x Power optimizers: o PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 850. SP followed by 001 to 350. *When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019 , modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. x 1-ph Inverters: Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 2 of 3 GFT-OP-10a o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix x 3-ph Inverters: o SE9KUS / SE10KUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS /SE43.2KUS / SE66.6KUS / SE100KUS ; when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. March 31, 2020 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05, ASCE/SEI 7-10, ASCE/SEI 7-16 2. 2006-2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 3. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 5. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where “L” is the span noted in the U-Builder online tool. Clearance: 2” to 10” clear from top of roof to top of PV panel. Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1 of 2 8150 Sierra College Boulevard, Suite 150, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment December 22, 2021 Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor ƳE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 2 of 2 8150 Sierra College Boulevard, Suite 150, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment EXP. 05/31/2023 T MCEWNOM OOF V I R GNAI ILA H ZACHER Lic. No. 402054550 ANOIS S E FORP L E N G IN EERPAUL K. DIGITALLY SIGNED This supersedes and replaces in its entirety all previously published versions of this document. T1470 (Last revised on 03.19.19) POLYURETHANE SEALANT & ADHESIVE 915 DESCRIPTION 915 sealant is a one-component, smooth polyurethane adhesive capable of dynamic joint movement totaling 70% of original joint geometry (±35%). The sealant cures to a tough, flexible rubber when exposed to moisture present in the atmosphere. Bostik 915 all seasons formula has physical properties that will remain relatively stable over time. The cured performance temperature range is -400F to 1500F. Where textured appearance is needed, please use Bostik 916. APPLICABLE STANDARDS • ASTM C920, TYPE S, GRADE NS, CLASS 35 USE NT, A AND M • US Federal Specification TT-S 00230C (COMB-NBS) for one-component sealants as Class A, non-sag • CARB, SCAQMD, and OTC compliant • Canadian Specification CAN /CGSB 19.13-M87 • Miami-Dade County, Florida, NOA No.: 13.0423.10, 05/24/17 • Miami-Dade TAS 102- Static Uplift Resistance • AAMA 808.3 • AAMA 100/200/300 installation requirements BASIC USES 915 is designed for applications from foundation to finish and is ideal for, sealing expansion and control joints, tilt up joints, perimeters of doors, windows, and other wall penetrations. It has tenacious sealing and bonding performance for many roofing applications, metal roofs, gutters, roof tile installations, flashing and sheet metal applications. 915 cures to form a durable, flexible bond with most building materials such as stone, foam, masonry, ceramic, wood, steel, Kynar® coated metals and copper and most other metals. INSTALLATION PROTOCOL Miami-Dade County Considerations: Mate or join adjacent surfaces prior to the Bostik 915 skinning and subsequent curing, to maximize wetting potential of the sealant to the substrates. Allow full-cure, typically 7 days, prior to any mechanical stress testing procedures. It is recommended that adhesion testing be performed to capture batch control qualities of proposed substrates. Joint Design: In general, more joint movement can be accommodated in a thin bead of sealant than a thick bead. Bostik 915 should be no thicker than 1/2" (12.7mm) and no thinner than 1/4" (6.4mm). In joints between 1/2" and 1", the ratio of sealant width to depth should be approximately 2:1. Sealant depth in joints between 1/4" and 1/2" should be 1/4" deep. Joints with dynamic movement should not be designed in widths less than 1/4". Surface Preparation: Surfaces must be structurally clean, dry (no frost) and structurally sound, free of contaminants, including, but not limited to, dust, dirt, loose particles, tar, asphalt, rust, mill oil, etc. If substrate is painted or coated, scrape away all loose and weakly bonded paint or coating. Any paint or coating that cannot be removed must be tested to verify adhesion of the sealant or to determine the appropriate surface preparation if needed. (See ASP section on next page for details.) Backer Rods and Bond Breaker Tapes: Bond breakers including, but not limited to, closed-cell polyethylene backer rods are used to control depth of the sealant bead, provide a firm tooling surface KEY FEATURES – Tenacious bond to difficult substrates – Permanently flexible – Miami-Dade approval NOA 17-0329.18, 15-0520.01 and avoid three-sided adhesion. Where the depth of joint prevents use of backer rods, a polyethylene strip or tape must be used as a bond breaker to prevent 3-sided adhesion. Do not prime or damage the surface of the bond breaker. Refer to instructions given by rod and tape manufacturers for the correct backer rod and tape size related to joint size. Tooling: 915 comes ready-to-use. Cut spout or tip to desired bead size. Apply moderate pressure to break seal inside the nozzle. Apply by using a professional caulking gun. Use opened cartridges and sausages the same day they are opened. Apply 915 in a continuous operation using positive pressure to the bottom of the joint to properly fill and seal the joint. When applying, avoid air entrapment and overlapping. Tool the sealant before the skin forms with adequate pressure to spread the sealant against the backup material at the bottom and sides of the joint. A dry tool with a concave profile is recommended for that operation. Do not use water or soapy water for this operation. Avoid smearing and feathering of the sealant to allow full performance of the cured seam. Excess sealant should be dry-wiped or joints should be properly taped. Cleaning: After dry-wiping uncured sealant from substrates and tools, remaining uncured sealant can be removed by using mineral spirits. Cured sealant is usually very difficult to remove without altering or damaging the surface to which the sealant has been misapplied. Cured sealant can be removed by abrasion or other mechanical means (scrapers, putty knives). Curing Time: 915 is a moisture cure, Polyurethane Sealant. On wood, with ambient air at 50% relative humidity and at 73°F, polyurethane sealants will generally skin within four hours and cure 1/16 of an inch per day. Lower temperature and lower relative humidity will significantly increase the skin time and cure time of a polyurethane sealant. Painting and Coating: Do not paint over the polyurethane sealant until it has fully cured. Maintenance: If the sealant becomes damaged, replace the damaged portion by removing the old sealant completely, cleaning the surfaces and reapplying a fresh and appropriate amount of new sealant in accordance with the directions and information contained in this data sheet. MANDATORY ADHESION TO SUBSTRATES PRETEST - (ASP) A hand pull test must be run before the job starts and at regular intervals during the job. It must be run on the job site after the sealant is fully cured, usually within 7 to 21 days. (Adhesion may develop fully after at least 14 days.) The hand pull test procedure is as follows: 1. Make a knife cut horizontally from one side of the joint to the other. 2. Make two vertical cuts approximately two inches long, at the sides of the joint, meeting the horizontal cut at the top of the two-inch cuts. 3. Grasp the two-inch piece of sealant firmly between the fingers and pull down at a 90° angle or more, and try to pull the uncut sealant out of the joint. 4. If adhesion is sufficient, the sealant should tear cohesively in itself. 5. Sealant may be replaced by applying more sealant in the same manner as it was originally applied. Care should be taken to ensure that the new sealant is in contact with the original, and that the original sealant surfaces are clean, so that a proper bond between the new and old sealant will be obtained. PACKAGING 10.1 fl. oz. Cartridges, 24 Cartridges/Case 20 fl. oz. Sausages, 12 Sausages/Case COLORS White, Black, Light Gray, Stone, Aluminum Stone, Limestone, Bronze, Medium Bronze, Terra Cotta, and Tan AVAILABILITY Available from authorized Bostik distributors. Go to www.bostik.com/us and check on our distributor locator for the closest distributor in your location or call customer service at 1-800-7/BOSTIK (1-800-726-7845). STORAGE/SHELF LIFE Store in a clean, dry area not affected by freezing or hot temperatures between 50°F (10°C) and 90°F (32°C). Shelf life is one year from date of manufacturing in unopened cartridge. LIMITATIONS • Construction substrates have become complex and diverse by nature and origin. Substrate chemistries and structures can interfere with adhesive performances of the sealant. Adhesion to Substrate Pretest (ASP) is therefore MANDATORY to assess any adhesion and sealing characteristics — see Adhesion to Substrates Pretest section and see Installation Protocol section. This must be done pre-installation to avoid potential failures. Call Technical Service for more information about surface preparation. • Do not apply over damp, contaminated, loose surfaces, old sealants or other foreign substances that may impair the adhesion bond. Avoid air entrapment. • Dampness and substrates with high moisture content will trigger extensive curing of the sealant within a very short period of time. This may cause an excess of bubbling and foaming within the sealant and at the bottom of the bead. • High temperature/humidity can cause the sealant to develop bubbles during the curing process. • Sealant installation is not recommended when the dew point of the substrate is close to ambient temperature or a moisture-vapor transmission condition is present increasing the potential for bubbling to form during cure. MANDATORY ADHESION TO SUBSTRATE (ASP) FIELD TEST SEALANT MUST REMAIN ON BOTH SIDES2"KNIFE CUT BOTH SIDES OF JOINTBACKER ROD • Porous substrates such as, but not limited to, marble, limestone, and granite might absorb components of the 915 leading to staining of the substrate. ASP with sufficient aging is mandatory to assess this potential issue. • 915 must not be used to seal narrow joints, fillet joints and face nail holes. • Smearing and feathering 915 over joints is not recommended. • 915 is not recommended for horizontal joints or traffic-bearing joints where abrasion resistance is required (walkways, driveways, runways, etc.). Please refer to Bostik 955-SL™ for this application. • 915 is not recommended for continuous immersion in water or any other fluid. When fully cured, avoid exposure, even incidental, to fuels, chlorinated, acid and alkaline solutions. Bostik 915 is not recommended for exterior or interior sealing below the waterline; please refer to Bostik 940 Fast Set for marine applications. • Contact of 915 with asphalts (i.e., back coating of window flashing, etc.) and other filler compounds impregnated with oil, asphalt, tar, etc., may deteriorate the cohesive strength of the substrate and ultimately compromise the seal. Please refer to PRO MS 50™ for asphalt applications. • Lower relative humidity and temperature will significantly extend the curing time. Confined areas, deep joints and moisture barrier substrates may also affect the full cure time and extend it by many days. Apply sealant in ambient air temperature of 40° F (4.4°C). and rising. • 915 may remain tacky for a few hours and attract dust and dirt from the jobsite which may affect the appearance of the sealant. Check tack-free time to prevent dirt pickup. • 915 is not recommended for glazing applications. Bond line strength can be affected by UV rays through the clear material (glass, acrylic glass, polycarbonate, etc.). • Do not paint over the polyurethane sealant until it has fully cured. • The surface of a 915 seal when exposed to UV rays and sunlight will yellow and will not retain its gloss. This phenomenon can occur within a few weeks after exposure. The change of color is limited to the surface layer of the seal and should not compromise the sealing properties of the 915 if the dimensions of the joint are proper and the sealant is otherwise properly applied. In areas where color retention is critical, please refer to Bostik PRO MS 50™. CAUTION IRRITANT. MAY BE HARMFUL IF SWALLOWED OR INHALED. CONTAINS POTENTIAL SENSITIZER. MAY CAUSE ALLERGIC SKIN OR LUNG REACTION. MAY IRRITATE EYES, SKIN AND RESPIRATORY TRACT. Do not breathe fumes. Do not get in eyes, on skin or on clothing. Do not swallow. Use only in a well-ventilated area or wear mask. Wash thoroughly after handling. Store container in a cool, dry area with lid tightly sealed. Do not reuse container. KEEP OUT OF REACH OF CHILDREN TABLE 1: TYPICAL UNCURED PROPERTIES* Property Value Test Method/Note Tool/Work Time 60 min.Bostik Test Method Skin Time 4 Hours Bostik Test Method Curing Time @770F (250C)2-7 days Varies w/relative humidity Flow, Sag or Slump 0.3 inch Bostik Test Method * Values given above are not intended to be used in specification preparation purposes. TABLE 2: TYPICAL CURED PROPERTIES* (AFTER 14 DAYS CURE AT 77°F AND 50% RH) Property Value Test Method/Note Hardness (Shore A)42 ASTM D 2240 Modulus @ 100% Elongation @ 25% Elongation 65 psi 45 psi ASTM D 412 ASTM D 412 Tensile Strength @ Break 133 psi ASTM D 412 Elongation @ Break 685%ASTM D 412 Adhesion Peel >5 piw TT-S-00230C / ASTM C 794 Joint Movement Capability +/- 35%TT-S-00230C / ASTM C 719 UV Resistance Pass ASTM C 793 Static Uplift Resistance (concrete roof tile)49 Miami-Dade TAS 102 * Values given above are not intended to be used in specification preparation purposes. COVERAGE FOR 10.1 FL. OZ. (300 ML) CARTRIDGE Width Depth 1/8"1/4"3/8"1/2"5/8"3/4"7/8"1" 1/8"99 49 33 24 20 16 14 12 1/4"24 20 12 10 8 7 6 3/8"11 8 6 5 5 4 1/2"6 5 4 3 3 Linear Feet Per 10.1 fl. oz. Cartridge COVERAGE FOR 20 FL. OZ. (600 ML) SAUSAGE Width Depth 1/8"1/4"3/8"1/2"5/8"3/4"7/8"1" 1/8"288 145 95 71 58 48 40 36 1/4"71 58 36 29 23 20 17 3/8"32 23 17 16 13 11 1/2"17 14 11 10 8 Linear Feet Per 20 fl. oz. Sausage BOSTIK HOTLINE Bostik, Inc. 11320 W. Watertown Plank Road Wauwatosa, WI 53226 www.bostik.com/us Smart help 1-800-726-7845 FIRST AID TREATMENT Contains petroleum resins, diisodecyl phthalate (DIDP), methylene diphenyl isocyanate (MDI), quartz silica. Methanol may form during curing. If in eyes or on skin, rinse with water for at least 15 minutes. If on clothes, remove clothes. If breathed in, move person to fresh air. If swallowed, call a Poison Control Center or doctor immediately. Do not induce vomiting. SEE SAFETY DATA SHEET CHEMICAL EMERGENCY: 800-424-9300 (USA), 703-527-3887 (International) MEDICAL EMERGENCY: 866-767-5089 LIMITED WARRANTY It is the buyer’s obligation to test the suitability of the product for an intended use prior to using it. The Limited Warranty extends only to the original purchaser and is not transferable or assignable. Any claim for a defective product must be filed within 30 days of discovery of a problem, and must be submitted with written proof of purchase. Limited Warranty found at www.bostik.com/us or call 800.726.7845. TO THE MAXIMUM EXTENT ALLOWED BY LAW, BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED WARRANTY, THE SOLE REMEDY FOR BREACH OF WARRANTY IS REPLACEMENT OF THE PRODUCT OR CREDIT OF THE BUYER’S PURCHASE PRICE. BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT, INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES TO THE MAXIMUM EXTENT ALLOWED BY LAW. DISCLAIMERS OF IMPLIED WARRANTIES MAY NOT BE APPLICABLE TO CERTAIN CLASSES OF BUYERS AND SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.