HomeMy WebLinkAboutBuilding Plan # 2Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered, rows 12" o.c. in field. Attach
12"
5/8" thick light textured O O
stucco on typical concrete �{,
block construction
--------------------------------------------
12E:
0
Finish Columns with
5/8" thick cut coral
finished stucco bands
W
RIGHT ELEVATiON
12
4 SLOPE
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
ELEVATION NOTES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood duck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4 side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two ,staggered rows 12" o.c. in field. Attach
/8" thick x 8"w cut
)ral finished stucco bands
� / V VIIwti �UL i.vI ul yLUf_L.0 Uri LIJ.pic ai GUr K.I a6a
finished stucco bands block construction
REAR ELEVATION
- Overhangs at
1'-0" unless otherwise noted
on Roof Plan
- Roof pitch at
4:12 unless otherwise noted
5v Crimp Metal FL 411451.12
,Any changes
to this plan shall be submitted
to the architect
Gulf Coast Supply and MFG roofing
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
for approval in writing prior to starting construction.
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
/�
- R e t u r n ALL
Stucco Bands Into uJ in d o w or
D oor. .
spaced 6" o.c. at all laps and two staggered rows 12" o_c. in field. Attach
deck to trusses using attachment detail on this sheet
2
o.H. 5/8" thick x 8"w cut
3 coral finished stucco bands 3
5/8" thick light textured
stucco on typical concrete
block construction
0'-0" = Finished Floor -------------------------------------------------------------
LEFT ELF-\/ATiON
SCALE: 1/4" = 1'-0"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors,
Windows & Skylights
Opening
NOA/FL
Product
Model #
Manufacturer
Glass
Attachment method
TEST
Design Pressure
Type
NUMBER
Date
of Approved Testa
1,2,3
Mi Windows
6 x elpcons ww mi pensi�etion at me
ram sac corner and L o.c. thereafter through PT Buck into
FLU 11499.2
Single Hung
Series 185
doors
anc
filled CMU wall maintaining min 2.5" edge distance m strict adherence
± 60 psf
t4
and
to the product approval.
A
I6-0330.02
Overhead
Model 824/811
q -4 max width
DAB
mite x V bTff 5.Xto concrete woct wth iiaiia I'difid call with
1) a5 bar v.rt. ueng 3/8' x 0 41ti HLC Weave encha a a a' o.c.
nh 1.25' dle. washers mth mia 4' edge dl.tanee. in.tan track 'e busk
bracket
10-9-21
+ 50.0/-60.0 sf
p
Garage Door
14'-0" max height
.rig to 5/IL' x 1 5/6' full thread lag ur, In each maintaining
n n of L5' edge dotanc. - GC to .tncttg adhere to product approval
ewide l/1L' ushnut Washer en roller shafts.
Elco 1/4" dia. tapcon with min 1.25" embedment at 3" max
B
FLU 16614.1
Fiberglass
Design Pro
Jeld-Wen
from corners and 11.5" o.c. max. thereafter in head and jambs.
+ 50.0 PSF
Pro/
smo,ot3
Sliding Glass
MI Windows
ia. x 3 cone w min. genet ation at L max.
Prom each corner and - o.c. al double row thereefrter through
C
FLU 15332.2
Door
Series 420
and doors
PT Buck into solid filled CMU wall maintaining min 2.5' edge distance
in strict adherence to the orapproval.
+ 48.2 PSF
-
Product
NOA/FL
Model #
Manufacturer
Attachment Method
TEST
Siration
Design Pressure
Date
of Approved Tests
NUMBER
For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment
CM-18531
Mi Windows
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
+ 118.9 PSF
Mullions
FLU 15353.8
vertical mullion
and doors
self tapping screws per clip as shown in product approval.
_
ROOF
FL# 11651.I2
SV Crimp
Gulf Coast Supply
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
Metal Roofin g
and manufacturing
(tgpe 2) 30 lb felt underlayment installed with min. 4 side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
- 108.5 PSF
?aced 6" ox. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on roof plan
.Siding
Stucco on Block
Soffit
FLU 12198.3 Model T4 12" vented Kagcan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
98 x 3" wood screws at each truss. Install soffit to battens using
+55.0/-35.0 PSF
Vinyl Soffit
y
0.12" dia. x 1.5" lono rino shank nails with 3/8" dia. head.
Hurricane
24 Gauge Global Protection
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
Panels
Flu I5016.2 Products LLC
Storm Panels
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45 0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of
Record
12
4 1 SLOPE
SCALE: 1/4" = i'-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11L51.12
26 wood-
5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of IS lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at C o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12"
12„
H. ® M ® H.
2"
. 5/8" thick x 8"w cut M ®®
coral finished stucco bands ❑ ®a lO
thick x 8"w cut
coral finished stucco bands
(�1111111,Gar.acie Finished Floor
A.F.F. 5/8" thick light textured Finish Columns with
pia stucco on typical concrete 5/8" thick
stt coral
ucco bands
block construction
FRONT ELE`/ATiON
SCALE: 1/4" = 1'-0"
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
x 4" studs at 16i' o.c.
base -board \ II II / 2 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
vxC #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
nts
Braden it
Braden AIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel :
(712) 281-8258
Fax :
(112) 281-8283
E-mail:
bradenaiaOcomcast.net
Stuart, FL
34996 #AAC000032
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 11.5 mph ultimate
Mean Roof Height: II'-0" Roof Pitch: 4.12
Internal Pressure Co�cient: ±0.18
Subjectability to damage from: Weathering: Negligible Termites: Verii Heavy
Width of Roof End Zone: - f" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.126
Adjustment factor for Exposure Height: ASO design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; 0.6DL+O.61DL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.L/-32A pat
Roof Zone: 2. +20.6/-51.0 pat
Roof Zone: 3. +20.6/-84.0 pat
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 oaf
Wall Zone: 5. +35.8/-41.8 pat
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 pat
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Deter Provided? Yes
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X Bg Test: psi
This Building Shall Have the Fallowing:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER;
ROOF LIVE LOAD: 3'11 pat ROOF DEAD LOAD: 10 pat
FLOOR LIVE LOAD: _11- oaf FLOOR DEAD LOAD: 10 pat
e 2,12
'ITCH
= Roof Zone I
Walls Zone 4
= Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
JOB ADDRESS:
FLOOR FL,4N
C2ASH POST DET A II
TYPICAL
MOTES: SCALE I/4" = I'-0"
N.T.S.
I.
Contractor to verify ALL notes and dimensions prior to
36" high by 4"
diameter
proceeding with work.
steel crash post.
Flange with 4 -
Floor
3/8"
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
exrrslon bolts
Into
3.
ALL Lumber to be used as Beam, Rafters, etc... to have
slab (3/8"t 5o
ksi steel plate)
a minimum 1,400 P.S.I. fiber stress.
6"
4.
No dissimilar metals to touch.
2A" 2,2"
S.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
�2
ALL Concrete used for vertical filled cells, coat. tie beams etc.. to
o
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
O?
at ceilings shall be leveled and attached to bottom chord
�,of
T
2,Drywall
trusses with screws per FBC R702.3.5.7.
ALL wood in contact with concrete shall be pressure treated.
0
8.
ALL wall dimensions are nominal and not finished wall or Stud dimensions.
h"
9.
ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater In accordance
with the current edition of the Florida Plumbing Code.
II.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
"
2y''
2''"
12.
Lowest finished floor to be set by Governing Building Department
0
/�
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15.
Wall and Ceiling shall have a flame —spread classification of not greater than 200 per
FBC R30219.1
16.
Wall and celling finishes shall have a smoke —developed index of not greater than 450
per FBC R302.9.2
171-
All exposed attic insulation materials installed on attic floors shall have a critical radiant Masonry Beam
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
I" x 6" P.T. Buck Walled to
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachment
with F.B.C. R316 — see permit info box of code edition
IS.
Gyypsum board material shall conform to ASTM C36, C79, C475, C514, C630, C931
C96C, C1002, C1047,C1111, C1178, CI278, C1395, or C1396 and shall be installed
according to the following: (FBC R702.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
fasteners
Nail sizing options for
sin
of
installation of drywall into
Nails
Screws
Maximum
wood framing members
2" x min. thickness
Ceiling
Perpendicular
24"
7"
12"
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
�2
annular -ringed or 5d cooler nail
OR
Walls
Either
16"
all
161,
0.080" dia. x 1 5/8" long with
Direction
I5/64" head
R
G psum board nail 0.084" dia.
x 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
71,
12"
13ga 1 5/8" long with 19/64" head
OR
0.098" diameter x 1 3/8" long
annular -ringed or 6d cooler nail
Walls
Either
I6"
8"
I6"
0.092" dia'xx 1 7/8" Ion with
9
Direction
1/4" head
OR
Ggpsum board nail 0.0915" dia.
x 17/8" with 19/64" head.
Install SGD thru buck into lJ O
block with 3/16" tap -con with
11/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A137.1
20. Cement, fiber —cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor —ceiling assemblies, roof —ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested In accordance with ASTM E 84,
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x 1 1/2" nails PRE-ENGINEERED TRUSSES
( 24" o.c.) supporting Max. 4 at 24"o.c. TYPICAL
IBIOIbs. uplift \ (shop drawings by manufacturer)
Aluminum Drip
Edge E Fascia
Li
U
V-1/2"
\R-30 blown fiberglass
In bottom chord of trusses
7
drywall with smooth finish
2" x 6" Sub -Fascia
Kaycan full o vent vinyl sofFit installed
using 1/8" din shank x 15" long gals.
roofing nails with 3/8" dia. head per
product approval -see chart sheet #1
Two rows of beam block filled with concrete
and (1) 45 bar Cont. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont. for bottom row over openings
1/2" drygwall over I" x furringg
strips at I6" o.c. with R4.1 frfod
—insulation on typical 8" Block walls
5/8" thick light textured
stucco on typical concrete
block construction
°
T
ro
All drywall to be installed per FBC R702.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R607.1
and Mortar Jonts shall comply with FBC R607.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap
Fill cell with concrete and
at each filled cell
Wood
Base
(I) #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with flbermesh OR
J,
6'xO 410/10 WWM on 6 and Visqueen over
/ clean compacted termite treated fill
ri
Grade r-
I1
-''�I=IIII�III, �,IIII ,, I IIII IIII III IIII���,IIII-11
1 ,14 x 14 Concrete footing
14 with (2) #5 bars cont. and #5
TY P I C A L S E C T I O N transverse bars at 48" o.c.
Scale : 1/2"
AREA CALCULATIONS
Living A/C = 144� Sq. ft.
Front Porch = 1,41 sq. ft.
Rear Porch = 200 sq. ft.
Garage = 321 sq. ft.
Total Under Roof= 2108 sq. ft.
Total Cubic Ft = 11,568
2' VTR
JIL
i
I
I
21" VTR
MasterCx� JIL
Bath
2• I
Lev. I
2•
Lev.
4• 1 2" VTR
W.C.
12.
ahar..Sher..o. To Septic
PLUMBiNGrt RISER
Bottom Track -—Typical Flooring
Sill Install SGD thru buck into
block with 3/16" tap -con with
Sl l d i n g D c o r D tall 1 1/2" penetration at o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval J a m b
At Masonry Wall NTS
Window
Schedule
Mark
Size
Rouclh open.
Window Description
PRESSURE ZONE
I.
4'-5%"x 5'-3%'
54%'x 63/4"
Single Hung
ZONE 4
2.
6'-2'/e"x 5'-3 %'
15" x 63 %4"
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
21Y2"x 38%"
Single Hung
ZONE 4
4.
4'-5%'x 4'-2%"
54%"x 54Ys"
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet i
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
t0 be verified bg contractor
with
manufacturers specs prior to construction
r
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X 1'-0"
108" x S4"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41 %4"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6'-8"
'14" x 61 /2" r"r a e°`.,
Sliding Glass Door
ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X C-S"
Solid Core - Wood
- 6-Panel
F
5'-0" X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x C-8" x i %4'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X C-8"
Solid Core - Wood
- 6-Panel
1
2'-0 X iI
Solid Core - Wood
- 6-Panel - Si -Fold
K
2'-e" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit Info
box on Sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED iN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction J
51
o I A IC
'4r
Meter
I
4'-O" 9'-6" 12"
(2)12
—l� 2
EGRESS
12" x 12" concrete column block filled
with concrete and (2) #7 bars vert. tied
Into lintels above
Covered Porch
cV U
00 O E ° MI ID
MASTER
1
BEDROOM 8'-0" tot 9'-8" A.F.F.
8'-O" A F F
Flat Ceding Vaulteld Ceding
GREIAT
O ROM
G I
I
Rod R helf
6'-O" 614,1 19'-8'
o
I
Vanity to be I 1 r l
34%211hig b- I N I N
O1 0 2" x 6" knee -wall 8'-O" to 9'-8" A.P.F.
rr r O IOC below counter top I Vaulted Ceding
_
s" _ 1 I DININGiEN
J
31NE Rod E Sh—elf 8 %S, p; I ROOM
— —Dul `� I
,NTH
Vanity to be
1 34 Y2"high
m KITCHEII H3h$all
I o
I
L
{ 8'-0" A.F.P. Overhang —
01 H — Flat Ceiling o � -
1
c
pper cabinets to
ext nd over Ref. — D 3'
1 Il
O E BATH
�R-II Baits nwletian
4"cl, Steel Ballard
W.H.
s
N l
I W
® N
See detail on i nirislblet
—
r
I 22i x 54'
Provide auto Attic Access
>
closer I with light
I
:3O
_ _
J
Q
o
22" -
150
Amp
4„
m
e
GARAGE
E�GREss
RGEN Y
O
8'-4" A.F.F.
00
MT
O
Flat Celhng
r'
(V
i
3'-5"
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6 o.c. max.
from each corner and 20." o.c. max
thereafter at ambs and 20" o.c. max.
Exterior face at head and sill per product approval
Of wall ---\ Buck to be I" x 4" PT
r-----------------i
Block wall in
gge to be
�- struarack block
I
I I
( I
I I
I
I
Rod ii Shelf C
L-AS'C" A.F.F.
Flat Ceding
II'-C
SECOND
BEDROOM'
EGRESS
0O O O HOC
O
I 3'-I"
—
C
VER
D
12" x 12" concrete olumn block filled
ORC
with con rete and (2) 7 bars vert. tie
into lintels bove
9'-0" 2'-8,
�I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
block with case hardened nails ON ALL JAMB, HEADER, AND
Detail a t W I n d OW S prior to window attachment SILL BLOCK PRIOR TO BUCK
INSTALLATION _
NTS
3'-4"
Exterior face
of wall —1
4'-2" 1 5'-41,
Attach buck to block wall with
1/4" dia. Elco cone screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
2" x 6" PT Buck
Detail at Door
Braden It Braden ,AI A, FA
Winne Building Corp.
Date Drawn :
Revisions
Architects - Planners
5-9-I1
S.E. Coconut Avenue
Tel
Tel (772)
The G r d n d Carlton
CLEFT E
Drawn by:
287-8258
Fax (772) 281-8283
E—mail: bradenaia comcast.net
C C.U.
Checkrs'd by:
Spanish Lakes
Stuart, FL 34996 #AAC000032
.
StLucre Count Florida
y
D.R_B_
A
b
crews thru jamb into buck
;cacn nmge and I5" o.c. max and
prior to door attachment
NTS
Sheet Comm #
2. 12-2�
OF 5
STRU(
TES:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (iF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2•
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
10.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 41 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE ="C"
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4
II,
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, &
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 307 STEEL.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
12.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
5•
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT FILL TO SPREAD IN 12" LAYERS AND
A 2
MACHINE COMPACTED TO A MINIMUM OF 500 PSI IN AREA OF
13.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
BUILDING CONSTRUCTION
FOOTING: 3"
BEAMS: I-I/2"
6
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
�•
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
14.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
15.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
8
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
16-
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
11•
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
FO
u
A
D/4
T
f O
N
F
L/
N
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soli conditions assumed to be 2800 psf. Should any other conditions be
encountered, the architect shall be notified in Writing for revision
4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
O.C. max. Provide (1) filled cell on each side of openings upp to 5'—I1" wide.
Provide (2) filled cells on each side of openings from 616" to 91—II"
and Provide (3) filled Cells On each side Of Openings from 10'—O" and Up
Contractor to see plans for any other condition used. Foundation walls
Shall have filled cells at 24" o.c. unless otherwise noted (see section)
�. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing Steel Shall be grade 60, meeting ASTM A-16 and
A-38 specifications. ALL Anchors to be A-30-1 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/211 concrete protection at beams for ALL reinforcing bars.
SCALE: 114" = I'-O"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
#5 bar Vert. w/
30" overlap
SEE AL
Thicken edge to 8"x8"
at each filled cell
ECTIONS
with concrete and
4" concrete slab with fibermesh OR
one US bar continuous 6 x6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
4" concrete slab with fibermesh OR
GRADE
CxC #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
E =
.. : •..: ,.: r -IIII -
8::
M
=IIII
III IIII 14"w x 14"d concrete monolithic
=� PORCH SLAB EDGE DETAIL
footing with (2) #5 bars cont.
SCALE 1/2"
14"
TYPICAL FOOTING DETAIL
#S bar Vert. w/
30" overlap
SCALE 1/2" = 1'-0"
at each filled cell
SEE TYPICAL
4" concrete
slab with fibermesh OR
Adjust curb height
ECTIONS
6"x6" #10/10
WWM on 10 mil Visqueen over
based on gar, floor
4"
clean compacted
termite treated fill
slope-
concrete slab with fibermesh OR
WWM on 10over
6 x " #10/110an 0amil Visqueen
#5 bar cunt.
45 bar in curb
fill
Step per
0'-0" a F.F.
o . foundation plan
Grade
m
10" (2) #5 bars Cont. bottom steel
II
14"w x 14"d concrete monolithic
12"
footing with (2) 45 bars cont.
2 DETAIL
AT GARAGE STEPDOWN
4
SCALE 1/2" = 1'-0"
GARAGE
CURB DETAIL
12" x 12" concrete column
SCALE 1/2"
block filled with concrete
and (2) #1 bars Vert. tied
into lintels above
Verify house slab
height in field
Top of footer
1C below finished floor
x
C�
I I-IIII
�II-IIII
IIIII
-
30°x30°xl6" concrete
column footing with (4)
2" x 6" PT wood secured
with
I1�1.
I- #5 bars each way
3/8"dia. x 6" anchor bolt
at 18" ooverhead
-
door track secured to wood
3'
jamb per manufacturer's product approval
30"
Garage Door Jamb
Detall
3 COLUMN
FOOTING DETAIL
GARAGE DOOR TO WITHSTAND PRESSURES STATED v
N PERMIT
INFO BOX ON
SHEET UL SEE PRODUCT
SCALE 1/2" = I'-O"
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
45 From Footing To Tie Beam
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
O a
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden it Braden AIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (712) 281-8258
Fax : (112) 281-8283
E-mail: bradenaia9comcast.net
Stuart. FL 3499(. #AAni0i0nn32
0
i
v
ri)
20'-0"
00
i:ll ��1
00 00
--------I
T
---------,o
F
t
I
Filled cell under
FI
girder above
24" I
I
0
J
Rear Patio/Slab
r
I
p
r
to
be poured
from the house
separate
slab.
1
ry
l
O
d
m
1
Thicken footing to
,
1
24"w x 14"d x 24"L
I
I FI
under filled cell
a
under girder bearing.
I
El
F)
y
"
12 0
0O
---
-- —
— — —
— — — —
— — -i0
Rear Patio/Slab to
I
be flush with
bottom
of
I
LE
sliding door
recess.
Slope
1/2"
I
F-
i
F-
I
I
F-
IF
1
I
F-
I
1
F-
I
IlO
I
FI I
32'-8"
I 4" concrete slab with fiber esh OR
a °
6"x6" 410/10 WWM on 6 mil V squeen over I O
clean compacted termite tr ated fill I
I I
OI Ic
F-
a
o V 6- F-
1
I I
FI i 0 (7)
O
U_j
o _
--———— — —
4"0 Steel Ballard
l/ w
tI
o
Concrete O
F S j
OI = I�OI I
Nov I I I
� � I I I
E t-
.I I o
y'a E I L Fi i
❑ I 3 C s, o❑° 00,
w�
o 3
I E _
I F5 "4 to a UJ I 0 0 O O(]
I tt-_ ° IL o
12
14'-6° I I
o I _Ln
I _
L — � Recess for — _ F4 r l to �I
00 00 Garage Door OO 00 -----------
F F
3'-5" 9'-O" 3'-5" 6'-2° Tconcrete
12" x 12" olumn block filled
with concret#7 bars Vert. ti
into lintels above
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
(n'
m'^ c AN
ndv m
50R
m -
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 tt5 BARS CONTINUOUS
F
12"W
X 12"0
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
30"
x 30" x IG"p
COLUMN FOOTING WITH (4) US BARS EACH WAY
F
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 45 BAR CONTINUOUS
x 1b
FS
With
With
a:
Curb at Garage
MONOLITHIC FOOTING
WITH 2 45 BARS CONTINUOUS - CURB a 0'-0"
Date Drawn Revisions : Sheet
5-9-11 Comm #
GARAGE Drawn by:
LEFT 3 . 12-2 �
C.C.LI_
Checked by:
D.R-E - OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX P'ywood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
4"
8d ring shank
16 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
6"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Verify with Plan
Concrete 12"x 12"
/ Lintel Column Block
p.
Reber
Rebar 48 Bar Dia.
Overlap
Column to Lintel 4ttachm&nt
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel. \-,
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calla for it.
Provide Cast -Crete ,-
eUe-OB/OT precast 7.- -
lintel set in mortar
Min. 8" Bearing
ovide PT Buck
.ached per ,lamb
ails into filled c
4" Pre -cast
Sill t
Filled Cell
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
'fllled cell steel into continuous
Tooter steel.
CBS WALL Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to Vert. leg of
truss with 10d x 1.5' nails at 4" o.c.
r Install Simpson MGT into wall using
Z/
rl 5/8" dia. threaded rod set min. 12"
\ into wet beam and (22) IOd nails into truss
NTS n
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tggpe 2 felt paper using 8d nails. Substrate
to be 19/32' CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL 411451.12
26 ga. Sv crimp metal roofing attached to plywood deck using 99 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6' o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \`
Additional Precast Lintel _
#5 bars
Lintel
Bar
Clear
"A
B"
6";'•:'yCLEAR
Length
Length
Span
Bars
Bars
2'-10"
2'-8"
1'-6"
2,93
none
1
3'-L"
3'-4"
2'-2"
2,#3
none
8F8-OB/IT 8FB-IB/IT BFB-IB/2T
Additional
4'-0"
3'-10"
T-8"
2,93
none
#5 bars
CLEAR ^.%r:`.{'!j
4'-6"
4'-4"
3'-2"
2,#3
none
�:• One Row of "H"
5'-4"
5'-2"
4'-0"
2,#3
none
,�:
Block Above '+�':;�':'�,
5'-10"
5'-8"
4'-C
2,#4
none
Precast Lintel;. •,'"���
2,#4
none
-' )
Addrtional ""'�< i
#5 bare �---- �
T-6"
7'-0"
6'-2"
2 #5
none
81111I6-iBAT 8FI6-IB/2T
8'-4"
T-10"
T-O"
2 #5
none
NOTES:
ALL reinforcing steel IS grade LO.
I. min. coverage of steel-1.5"
2. min. bearing required 6 ea. end=8"
S. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LiNTEL SCHEDULE
Mark
Window
or D
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
Bottom
Steel
`me
Top
Steel
Size
Max.
Gravity
cad
'PLF)
Max.
Upldt
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
2'-V
3'-6"
81z8-OBAT
1
#5
3069
1549
1024
1_31
2'-6"
4'-O"
aFa-OBAT
I
tt5
2561
1343
163
L45
4'-5"
5'-10"
8F8-OB/IT
I
#5
1105
909
339
L50
5'-O"
V-6"
8F8-OB/IT
1
#5
Mae
835
121
L40
6'-8"
T-6"
BPS-OB/IT
1
tt5
1011
721
534
LBO
8'-0'
9'-4"
BPS-IB/2T
I
#5
2
#5
152
591
512
L90
9'-0"
10'-6"
8F8-IB/2T
I
#5
2
tt5
643
530
401
L90B
9'-0"
10'-6"
8FI6-IB/2T
ONE
1
#5
2
tt5
1533
1183
401
LI00
10'-0"
II'-4"
BF8-113/2T
1
#5
2
#5
582
494
1 452
LIOOB
10'-0"
II'-4"
8FI6-IB/2T
ONE
I
tt5
1 2
#5
134L
1028
452
LI20
12'-0'
13'-4"
8F8-iB/2T
i
tt5
2
tt5
411
428
324
L120B
12'-0"
IT-4"
8FI6-iB/2T
ONE
i
#5
2
#5
i015
110
324
L140
14'-0"
15'-4"
BFIL-IB/2T
ONE
1
95
2
tt5
1250
L09
259
LI60
IL'-O"
li'-4"
BPS-IB/2T
1
tt5
2
#5
300
192
194
L140B
16'-0' 1
IT'-4"
BFI1.-IB/2T
ONE
1
#5
2
#5
950
500
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED,
5impson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails —
( 24" o.c.) supporting Max.
18101be. uplift
Aluminum Drip
Edge t Fascia
12"
2" x 6" Sub-Fasci
Kaycan full o vent vinyl soffit installed
using 1/8" dia shank x 15" long galv.
rooting nails with 3/8" dia. head per
product approval - see chart sheet #I
12" x 12" concrete column
block filled with concrete
and (2) #1 bare vert. tied-'
into lintels above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of footer
I6" below finished floor
d
12
F
4
Aluminum Dnp
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truZ11
with (2) IOd
at each web
1/2" thick stucco an 3/8' hi -rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar Vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Poured
concret
Poured Conc
concrete bloc
Concret
Manufact
chore Per
Specs
lax.
Aluminum Panel
Sizes per manufacturer
— See Tuorcal Stud Detail
7/8' x 3/32" Wing Nut w/
approprmte washer and spacing
vper manufacturer's Details
� OL3'
a
� 09q"
E
9 m r m
Imo
I L�_.1915"
Stud Detail
Stud w/ Die Cost Zinc NTS
Nickel Plated Wmg Nut
IH"
Flush Mounted Shutter Detail
nts
Brace Gable end
with 2" x 4" SYP #2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
RE-ENGINEErc4--D WOOD TRUSSES
9 24"o.c. TYPICAL
( shop drawings by manufacturer )
O
N
Ul
3
to
in
=
X
a3
O�
rn
N
�
QI
o a
d
L
Tt
N U)
O to
d)
U
p O
CT)
L
X
EUIC
Brace Gable end
with 2" x 4" SYP #2 min.
8ft back nailed to bottoms
of top chords using (2) IOd
nails at each truss
"\R-30 blown fiberglass
in bottom chord of trusses
1/2" drywall with smooth finish �
Two rows of beam block filled with concrete
and (U 45 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont. for bottom row over openings
1/2" drygwall over I" x furringg
strips ai 16" o.c. with R4.1 fl-foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
i and shall meet all pertaining ASTM codes.
bo Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar joints shall comp g with FBC RLO1.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
111
U
Strap truss to wall
using Simpson MGT with
Simpson
HETA 20
5/8' dia.
threaded
rod with min 12" embedment
hurricane anchor
at each truss
into beam
(22) IOd
truss leg
either wet
nails into
per detail
set or in epoxy with
truss. Add blocking to
on this sheet t
( 24" o.c.)
HETA 20 1810
supporting Max.
lbs. uplift
WON
L\
Jt411
WE
ELI\
w
'All
SO
11
VA EA WIMA VArA
M
W-A
-,
ME
Me. HIM,
0
A,
iv
il WINA
ArA
map, F,=A
WAS A PA WAR "A SEA
I
i
1 Gulf Coast Sut)DI4
JUL woog"alcrews with
IV
if r
sealing washer at 12" o.c. max spacing over ASTM 0
(type 2) 30 lb fel
Underlagment installed with min. I" side,,Iaps and 4" end
i
if 0)--IaDs fastened with .7orrosion
resistant tin caps and with 1.25 rinq shank nadc
ir
ly
I with light
'4 SLOPE L
I
l�imimi
oil
MINE
HETA 20
FIII cell with concrete and
(Max.0 #5 Vesha
rt. (typical).48"
ROOF 1"
L l
ppbar
not exceed
i4�l
wood
Base
unlessnotherrwise noted
see foundation plan notes for
— OVERHANGS
AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
1
spacing at openings
4" concrete slab with fibermesh OR
— ROOF PITCH
AT 4:12 UNLESS OTHERWISE NOTED ON THiS SHEET
CxC #10/10 WWM on L mil Visqueen over
— TRUSS SHOP
DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill
— ANY CHANGES TO 7H15 PLAN SHALL BE SUBMITTED TO THE
=III1111I I11 IT I I f '�l l i-
1111=1111=11II 11II��IIIIIli,,llll=i���=�►i��ii 14111 I��- FI
IIIIIIIIII "
1�1111 3 TLIblcal Section at Front Forch
scale
: IZZ' = I'-O"
Braden III
Braden ,AIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: M2) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaia°comcast.net
Stuart. FL
34996 #AAC000032
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
Wynne Building Corp. Date Drawn : Revisions: Sheet Comm #
5-9-11
GARAGE Drawf, by:
The Grand Carlton LEFT C.C.U. 4. 12-2�
Spanish Lakes Checked bg:
St. Lucie County Florida D.R,B. OF 5 i
PANEL
'iA"
circ# circ# Description Wire Load BR Poles
1 2 AHU #l0 3.5 kw 30 2
Poles
BR
Load
Wire
Description
2
40
1.0 kw
#s
A/C comp
3
4
2
30
4.5 kw
#10
40 gal. water HTR
5
6
Range
#6
12.0 kw
50
2
8
1
20
1.8 kw
#12
Pump
9
10
#10
5.0 kw
30
2
II
12
I
20
1.5 kw
tt12
13
14
r
#12
1.2 kw
20
1
20
1.5 kw
#12
Microwave
15
16
tor
912
L2 kw
20
I
1
20
1.5 kw
#12
Kitchen S.A.C.
11
18
ffReceptal
l
20#12
20
1.5 kw
#12
Kitchen S.A.C.
19
201
20I
20
1.2 kw
#12
Clothes washer
21
22
#12
201
20
0.81 kw
#12
Garage Door Opener
23
24
#12
201
20
1.4 kw
#12
25
26
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
ttl2
20
I
1
20
#12
General Lighting
29
30
Recepts
#12
1
1
20
#12
General Lighting
31
32
Recepts
412
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
120
1
I
20
#12
General Lighting
35
36
Bathroom GFI
912
1
#12
Smoke Detectors
3-138
General Lighting
#12
1
I
20
#12
Bathroom GFI
39
40
General Lighting
412
20
1
spare
41
q2
spare
PANEL "A" LOAD CALCULATION SHEET
Load [Description
Qt .
Watts
Total(Watts)
General Lighting (3 ,watts sq. ft.)
S,inall. ,A,pp(iance_ C.ircuit(.$). ..... .... ....................
Range .................. ......... .........................
Refrigerator...................................................
Microwave
Dish Washer ... ........................ .. ..................
Clothes..Wpsher_............................................
Clot hes..Dryer...........................................
Water Heater
Water_ .Pump ..................................................
Garage. Door Opener
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
I
1,200
1,200
1
5,000
5,000
1
4,500
4,500
1
1,800
1,800
1
810
810
Total Watts
31,415
First 10000 Watts 8100%
1
10,000
10,000
Remainder 21,415 a40%
1
O
10,966
Electric Heat or A/C 10,000 865%
1
10,000
10,000
Calculated Load
Watts
30,966
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
53
Double Pole Switch
®
Egeball Recessed
PB
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
o-
Wall Mounted Light
�
L.P. FC
Waterproof ground fault circuit
�
Light with Pull Chain (attic)
®
Floor Duplex Outlet
@
I Computer Connection Jack
cM
Carbon Monoxide Detector
'V
Flood Light
TO
Thermostat
®
Electrical Panel
®
Central Vac
g
Electrical Meter
05
Smoke Detector
Ceiling fan
©v
Television Jack
Telephone Jack
A C c>�s c
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
sPKR
Speaker Hook -Up
❑I
Intercom
143 CFM
IOx1Oxb
MASTER
BEDROOM
163 CFM
IOXIOxb
12xl2x9
B/A
F-I F1
° B%Ax9
CLOSE
.B.
CFM a
8x4x4 I i
X4
Vent
-thru ---- _
Soffit ATH
I -\
o \
10" I o
PATIO/SLAB
I
CAR IAT
ROM
I
I
Center Registers CFM
169 CFM on Ceilingfan
IOxiox I \ IOXIOxl
_141
1211
DINING
ROOM
Exhaust Duct
Thru Soffit
L-- - - - - --
L
1512xICz;
d
�
I
H.B.
20 CF i 4" I 1 FM
Vent thru
Bx4x-4 R%�1 8x - - -
-
--
5 of fit
I o I Lceinling;
'�` T H
- - - - 20►r20
�{" Exhaust
7 i
Duct Thru
A/C
----- -
W.H.
I
Wall
WP GFCI
#I
1"I" I nu 116"
22" x 54" �* > I I
Attic Access73 0I
1 with fight I 1 1CFM Xl I i 2XL-
L - - hl - _ I <J
Install oulet
under disc.
not shown or
clarity C
IL _ _� I'„
we
L�-fir
150 Amp `
A/C
Meter
Panel \
#I
\\� SECOND
44
35 CF
GARAGE I BEDROOM
I
12xl2x8
B/A
Meter r
-----------------
(9 - JUNCTION BOX TO SUPPORT A FAN � E C � � N I C � L L � o U T
O = THERMOSTAT LOCATION
B/A = BALANCED AiR
Electric Notes: SCALE: 1/4"= I'-O"
I.
Use copper wire only, no aluminum.
11. It is not the intent of these plans to show every minor detall
2.
Provide and wire all required smoke detectors.
of construction. The contractor shall furnish and install
3.
Contractor to verify location of electrical
all items for a complete electrical system and provide all
service and provider.
the requirements necessary for the equipment to be placed in
4.
ALL paddle fans shall be on a rheostat.
proper working order.
S.
ALL bath and kitchen receptacles to be GFI protected.
18. All work shall be done in accordance with the N.E.C. and
4,
ALL exterior outlets to be WP/GFI protected.
shall comply with all local codes and ordinances, and shall
1.
Recessed cans to be installed per NFPA requirements.
meet all standard requirements of the local electric utility
8.
AFCI receptacles are required in all rooms except
and telephone company.
iGitchen, Bathrooms, and Garage.
9.
A/C Return Air Balance Must comply w/ FBC RM1602
19, The electrical system shall be completely and effectively
10.
A/C Refrigerant lines that are run thru slabs must be
grounded as required by the latest edition of the N.E.C.
sleeved in PVC
II.
ALL A/C Equipment shall comply with energy calculation
20. All material shall be new and shall bear underwriters'
12.
All work shall be performed by a licensed electrical
labels where applicable,
13.
contractor, the completed system shall be ful14 operative.
Contractor shall pay for all fees, permits, testing, and
21. All equipment and panel sizes shall be verified before
inspections including blower testing where required.
ordering. The contractor shall provide circuit routings to
14.
All work shall be coordinated with other trades to avoid
suit the job conditions.
15.
interference with the progress of construction.
All required insurance shall be provided for protection
22. Furnish and install ail fixtures as called for on the plans
against the public liability and property damage for the
or as selected by others.
duration of the work.
1L.
Contractor shall guarantee all materials and workmanship
23. All raceways and pipes placed in or through any concrete
free of defects for a period of not less than two years from
slab shall be spaced a minimum of three diameters of the
the date of acceptance or certificate of occupancy, or one
largest conduit or pipe from any other service.
year from closing sale of house.
Correction of defects shall be completed without additional
24. All exposed wire below 9'-1" shall be installed in metal EMT
charge and shall include replacements or repair of any
conduit.
other phase of installation that may have been damaged.
25. Dryer Vents to be installed per FBC RM1502
COVERED
PORCH
A/C I�disc.
UJ 1
150
u2/0 Aluminum feed AMP
MCB
1 '/2" Conduit -�_ PANEL
2" PVC ( FP
2" rigid service FPL to U5#'orct?1.prebar i in slab
ELECTRICAL jRiSER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden III
Braden ,AIIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax :
(112) 281-8283
E-mail:
bradenaia5comca5t.net
Stuart_ FL
34994 #AAC000032
PATIO/SLAB
/Covered Porch`,
MASTER
� BEDROOM
\ I WP GFCI
TY TY `S I TV
� I
- - Smoke / Carbon G� R A T
Monoxide Detector R q O M
Combo
CM I
1
GFCI I
Ib" TV
CLOSE I =E)
I II
rC,F
DiNiNG
- GFCI
rc I
ROOM
1_ Pc
OFAN M °
KITCHEN I €
I I L - Smoke P Carbon - -
Monoxide Detector
kso
24" 3'-2" 3'-2" Combo
$CMGFc� � FM
N
GF GFCI
42" GFCI
------
I _/w � I
22" x 54" > Cente `
I Attic fiAccess
light I
---/ t-� \\SECONDS
15o AmR Optional
Panel \ 1 panel location S TV \
Pull chain ,S \
� e light in attic
m S
42" GFCI \
GARAGE �
II Garage /
Door /
-Opener--- \
WP
I I /
I I
_COVER�'� /
I-1 P-012-CH
H
ELECTRIC/4L FL/4\
Attic Venting Calculations FBC 230,
Total Attic Space = 2124 sq, ft.
\/enting Ratio I/GO = 1-4.1� sq. ft. required
fi rovide A Continuous Vented Soffit
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
SC i4-\Ltz: I/'t
Post Light with
Photo cell
Date brawn Revisions
5-9-11
GARAGE Drauln by:
LEFT C.c--.U.
Checked by:
0.R?-B-
IF
Exhaust Duct
- Thru Soffit
E Wire For
Front Post
Light
Sheet Comm It
E-1 12-2�
OF 5