Loading...
HomeMy WebLinkAboutProject Information- Project Summary Wrightsoft Endre'House . QUICK CALCS, INC. 317 ST'LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 . Fa)c 772-466-6796. Email: QUI For. THE ROYALE WYNNNE DEV., FT. PIERCE, FL Notes: \ Design Information Weather: FortPierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF r Heating Summary Structure 19898 Btuh Ducts 6092, Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) VOlume (ft3) Air changedhour Equiv. AVF (cfm) Simplified Average Heat"1720 Co 17A 14231 14231 0.38 0.20 90 47 Heating. Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input . Heating output Temperature rise Actual airflow Airflow factor Static 'pressure Space thermostat:. Capacity balance point = 35 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0045 cfm/Btuh 6.50 in H2O Input = 7 kW, 'Output = 23009 Btuh, 100 AFUE Job: Date: By: Summer Design Conditions Outside db 90. OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/lb Sensible. Cooling Equipment -Load Sizing Structure 18607 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh (none). Blower 0 Btuh. Use manufacturer's data in Rate/swing multiplier 0.95 , Equipment sensible load 26420 Btuh. Latent Cooling Equipmentlo' ad Sizing Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 cfm) 0 Btuh (none). Equipment latent load 4697 Stuh Equipment total load 31117 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 . Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360. Btuh Latent cooling 10440 Btuh Total cooling. 34800" Btuh. Actual .airfiow 1160. cfm. Air flow factor 0.042 cfm/Btuh Static pressure 0:50 H2O Load sensible heat ratio 0.86 .in Calculations approved,byACCA to meet all requirements of Manual J 8th Ed. Wr19ht50ft' . Right -Suite® Universal 201717.0.14 RSU08101 AI✓� ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:29:34 Page 1 - wrlghtsoft' Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. L'UCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 77246"796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 " Room name Entire. House BEDROOM 2 Exposed wall 180.9 ft 52.0 ft 3 Room height 8.3 ft. d 8.0 ft heat/cool 4 5 Room dimensions Room area 1719.5 ft2 1.0 x 343.0 ft 343.0 ft2 Ty Construction number U-value (Btuh/ft *F) Or HTM Btu 2) Area (ft2) or perimeter (ft) Load (Btuh) Area ' or perimeter (ft) (Btuh) Heat Cool . Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 VI�f-G 13A+7ocs. .. 1Ac1om 0.143 1.270 0.770 '" n n" ; n �4.00 35A 21:56 255 34.77 19.31 577 16 38 ' " 524 0 6 2096 565 815 1333 553 730 .12 0 0 72 0. 0 288 :0 0 ; 183 0 " 0 11 W 13AAocs „ 13A4ocs 1Ac1om :: 11D0` 0.143 0.143 1.270 0.390 ne e a e, 4,00 .'4.,Op 355B .. .10.92 2.55 2.55 87.29 .11:31' 34 •112 24 . ':.,21. 34 67 3 , •: 21' 136 269 848 ; 229 86 171 2082 '. ; . 238 0 0 0 U 0. 0 0...0 0 0 0 0 0. W . 13AAocs 13A-0ocs : -IAc1om .r 0.143 0.143 ;1.270 se s ; t s? 4.00 4 00: 35:58 2.55 2.55 . "34.77 23 456 7 23 449 14 91 9798 .. .:•" 247 58 :, 1143 . 241 0 . , 232 . •. 0 0 `, 232 0' 0 ' 929 =0, 0 591 0: V�J I-C L-C 13A-4ocs 1A-c1om 4A5-2om 0.143 1.270 0.770 w w w 4.00 35.56 21.56 2.55 55.25 45.63 128 290 33 41 n4 217 4 4 ` : ; .224 867 1162 880 ; 571' 651 1806 1862 : 287 112 33 0 '. ` 0 79 2 0 :: 0 318 1162 0 ., 0 202 1806 0 0. C . 16A-30md " 0.032 - 0.90 232 1720 '1720 .1541 .:.' 3989 343 343 307 796 F 22A tpl '..: - . , i 0:989 : =''': "27:69 0 00 1126 :: .181 : 5010 : 0 '","' . 343 ...: 52 f ' ;. 1440 t l' - 6 c)AED emursion 465 668 Envelope loss/gain 17124 .15595 4444 4245 12 a). Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal Qines 6 to 13) 19898 18607 5218 4463 Less eAemal.load 0 0 0 0 Less transfer Redistribution 0 0 .0 0 0 0 0 0 14 15 Subtotal Duct loads 31% 49% 19898 6092 18607 . 9204 31% 49% 5218 1598 4463 2208 Ff Total room load 25990 27810 6815 6671 Air required (cfm) 1160 1160 304 278 Calculations approved byACCA to meet all requirements of Manual J.8th Ed.. A wrightsoft- 2017-Apr-1017:29:34 Right -Suite@ Universal 2017 17.0.14 RSU08101 ...1Quick Calcs%Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Page 1 -�- wrightsofta Righte-l0 Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email; QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 . Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 7.0 x 8.0 ft 56.0 W Ty Construction number U-value (Btuh/ft2�"F) Or HTM (Btu 2) Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13AAocs 0 143 . n 4.00 2.55 0 0 0 0 0 .0 - 6 0 1A c1om 1 270 n- 35.56 : 34.77 0 .0 0 0. 0 0. 0 0 4A5-2onn 0.770 . -n 21:56 . 19.31 0 0 0 0 0 0 0 w 0 W .. 13P•Aocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4ccs 0143 e. 4 00. 2:55 0 0 0 0 0 0 0 '0 1A c1om 1276 e, 35'56 87:29 0 0 a 0., 0 0 0, 0 0 _ r0.390 , e'; 1.092 1t_31, -,. 0 :%.. p .' .. . ': p : U _: 0 : !0 W 13AAocs 0.143 se . 4.00 2.55 0 0 0, 0 0 0 0 0 13A-0ocs 'r ; 0143 :: 4 00. 2 55 0 ; . 0 0 0 ' 64 ::> a. , 228 145 :1Ac1om `. :1 270 s .' 35:56 - 34:T/ 0 0 0 ;.. 0 ,: 7 . 7 247 , .. ;N1: yJ 13A-4ocs' 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 I�-IGi 1Ac1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2om 0.770, w 21.56 45.63 0 0 0 0 0 0 0 0 ;12C-0sw;:'::' ; ; 0 pg1 : ° .. 2 55; ' .1'.28 0 '0 :. p _ . 0 ' : , :. p p . p 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 66 56 50 130 F, . 22l tpl 0980 <` :: 47:69 AM.: 63 ' . ' 0 . ' - ' _ :0 .. p ' .. 56 : ` . "8 , :222 0: Aj 6 c)AED excursion -10 -39 Envelope loss/gain 56 136 747 477 12 a) Infiltration 0 0 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 136 866 511 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 15 Duct loads 31% 49% 17 67 31% 49%1 265 253 Total room load 74 203 1131 764 Air required (cfm) 3 8 50 32 Of AMA wrightsot' fRight-Suite® Universal 2017 17.0.14 RSU08101 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N . 2017-Apr-1017:29:34 Page 2 F wrightsoft' Right-M Worksheet Date: Entire House °ate` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 Bq)osed wall 0 ft 5.0 ft 3 Roam height 8.0 ft heat1cool 8.0 ft heat/cool. 4 Room dimensions 1.0 x 172.0 ft 9.0 x 5.0 ft 5 Room area 172.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft-) Load number (Btuh/ft2L_°F) (Btuh/ft2) or. perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4ogs 0143 in 4.00 2 55 0 0. 0 0 40 40 160 102 9- orn 1 270 •n' 35:56 . 34.77 0 0 0 0' 0 0 10 0 -4A5-2om: 0.770 ; n 21:56 : 19:31 0" 0 0 0 0 .0 0 0 11V 13A4ocs . 0.143 ne 4.00 2.55 0 0 0 0 0. 0 0 0 11 13A4ocs '0143 a 4.00 2:55 0 0 0 0 0 0 0 0 lA-clom 1 270 :e . 35:56 8729 0 -0 0 0 - 0 0 0 -.0 0.390, -e: 10* : `1731 _ 0 0 0`. .0 ''0- 0 .0 0 W' 13A4ocs 0.143 se 4.00 Z55 0 0 0 0 0 0 0 0 13A'4 cs 0143 s ; 4j00 2 55 ,0 0 0 :- • 0 ' . 0 ; '0 ;0 ° 0 ! . _G 1A�1om:: 1:270 s'' 35:66 34:77 0 0 - 0 " 0 .... .:0 : `0 0 e0 V�J 13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 �G 1A-c1om 1.270 w 35.56 55:25 0 0 0 0 0 0 0 0 L--G 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P. 1200sw:., ... Q.091;.,..-., }2;55:,:... .1:28 =,64.._ ,.-64. 163':;_ 82. ;..r. :,0..: ..0', C 16A-30md 0.032 0.90. 2.32 172 172 154 399 45 45 40 104 F" 22A'tpl ;. 0:989 : -:. _ . ", 27.69 6.00 '. `172 ': 0 0 ." 0 ; ' 45 •" " .5 6 c)AED'excursion -176 -16 Envelope loss/gain 317 305 339 190 12 a). Infiltration 0 0 74 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 317 2.305 4.13 . 211 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 31% 49% 97 1140 31% 49% 127 104 Total roomload 414 3446 540 315 Air required (cfm) 18 144 ' 24 13 Calculations approved byACCA to meet -all requirements of Manual J 8th Ed. A -*- wcigF�tsoft• 2017-Apr-10 17:29:34 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoft Right4i@ Worksheet Job: Entire House Date: l QUICK CALCS, INC. BY: 317 ST. LUCIE:LN.. FT PIERCE, FL 34946 Phone: M466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRY 2 E:�osed'wall 42.6 ft 6.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heattcool 4 5 Room dimensions Room area 1.0 x 204.0 ft 204.0 ft2 1.0 x 97.5 ft 97.5 ft2. Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross I N/P/S Heat I Cool 6 V 13A4ocs 0.143 n .4.00: 2.55 - 112 112 448 285 0 0 0 ' 0 1A c1om 1:270 .. n 35:56 34.77 0 0 0 0 0 0 0 0 4A5 2iim - :. 0.770 n 21.56 19.31 0 0 0. 0 0 0 0: 0 W 13A-4ocs . 0.143 ne 4,00 2.55 23 23 91 58 11 11 45 29 11 3A 1�4ocs' 0.143 e , 400 255 72 48 193 123 40 _ 19 76 48 1A�1om ., '1270 a 35:5ty 87.29 '24 2 ;848 L 2082 0` " 0 A 0 11p0. 0.390., e , 10:92 11.31 0. 0 _ A ., . . A, . 21 `, 21 229 . :.,238 W 13A-4ocs 0.143 se 4.00 2.55 23 23 91 58 0 . 0 0 0 13A flocs 0:143 s : 4:Oq 255 112 112 "' .448 285 :. 0 . 0 i ]Ac1om.'- 1.270. s `: 35:56 34.77 .p 0 p. 0 p.: 0 :,p p VjJ 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 {�-CG 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5.2om . 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 .0.091 . -i< 2 55 1i28 i;: 0 , 0 , •0 ; 104 i . 104 ' '` , .:265 ;133 C 16A 30md 0.032 - 0.90 232 204 204 183 473 98 98 87 226 1 . 0.989 : .- 2769 : `.,0.00 :. 204 :. 43 `,,.. 1179 0 98 : 6 ; :175 0 6 c)AED oxursion. -90 -50 Envelope loss/gain 3481 32731 878 625 12 a). Infiltration 634. 179 95 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4115 3452 974 651 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 496% 1260 1708 31% 49"/u 298 322 Total room load 5376 5159 1272 974 Air required (cfm) 240 215 57 41 Calculations approved bVACCA to meet all requirements of Manual .J 8th Ed. wrightsoft* 2017-Apr-1017:29:34 A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N 9 - 1- wrightsofr Right-JO Worksheet Job: Entire House Date: By:. QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: 6UICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 EJ-4posed wall 6.0 "ft 48.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4 . Room dimensions 7.0 x 6.0 - ft 1.0 x 528.0 ft 5 Room area 42.0 ft2 528.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 -13A-4oc.a 0143 " n' 4.00 2.65 0 0 0 0 . 249 211 646 .538. 1A c10m` 1270 " n' 35:55 34.77 " 0 0 0 .0 " 0 0 0 0 4A5 tom : 0.770 : n 21.56 19:31 0 0 0 0 38 0 815 730 W 13A4ocs 0.143 ne 4.00 Z55 0 0 0 0 0 0 0 0 S AWS MAW 0143 a 4.00 2;55 0 ..0 0 0 O. 0 0 . 0 1A c1om • ' 1-270 a •; 35:56 87;29 0 0 0 0 .. 0 0 0 . 0: 0390re: 10:92. .11;31 p .p, .. 0:. 0... ::0.. 0:. ;:p W 13A4ocs 0.143 se 4.00. 255 0 0 0 0 0 0 0 0 13A�ocs 0.143 s ~ 4 00; 2 55 `48 48 192 122 0 :"' 0 15270 .. -s = . 35:56' 34;77 :0 0 0 0 -. 0 , 0 , 0 0' 'L-G13A4ocs 0.143 w 4.00 2.55 0 0 0 0 178 137 549 349 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 41 2 880 1862 P . ,,::12C0sw .:: :<U:091 _:.:, :2:55;. 128 . 56 -°..56 ; ..' 143 ; ;...:. 72.;.- 0 :0',. . p _, '0 C 16A.30md 0.032 - 0.90 2.32 42 42 38 97 528 528 473 1225 F s22A;tpF :..::.:.- .: 0.989 ; - : 27b69 ... `0:00 =42 8: :- ., ;..166 " . 0 °•. 528': ..: 48 :'. .:1329 . 0 6 c)AED oxaursion -22 305 Envelope loss/gain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Pines 6 to 13) 628 294 5W7 5232 Less ex£emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 628 294 5687 5232 15 Duct loads 31% 49% 192 146 31% 49% 1 1741 .2588 Total room' load 820 440 7428 7821 'Air required (cfm) 37 18 332 326 g=.A - -. wrightsoft' 2017-Ap0017:29:34 Right -Suite® Universal 201117.0.14 RSU08101 Page $ ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N t wrWhitsoftr Right -A Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 31r 01. LUUIC LN., r I. rIMMUM, rL W%Igo rnone: itz-4bo-OPoy rax rrZ-400-ofut) Cmall: UUIUKUALU5(Q%IUL.UUM 1 Room name BEDROOM 3 2 Exposed wall 13.0 ft 3 Room height I 8.0 ft heaticool 4 Room dimensions 13.0 x 13.0 ft 5 Room area 169.0 ftz Ty Construction U-value . Or ATM Area (ft') . Load Area Load number (Btuh/ft2- F) (Btuh/ftl) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 '• n, 4.00 2:65 104 88 353. 224 1A�1om " .1.270 •'.n 35.56 34.77 16 ' 0 565 553 4A5 tom 0.770 : n 2146 .1931 .0 0 .. 0 . 0 W 13AAocs 0.143 ne 4.00 2.55 0. 0 6 0 11 13A1locs 0:143 e 4.010 255 0 0 0 0 1Ac1om ` 1:270 e> 35'56 87:29 0 0 0 0 .. .11D0 . , :- -:0:390 ., e : 10s97 . _ 11 31 0 0 .­0-0 W 13AAocs 0.143 set 4 00 2.65 0 0 0 0 13A-0acs ;: 0.:143 s 4.00 2.55 0 0 0 0 1Ac1om. _. 1270 s :- = ..35:56: 34:TL • 0 13A-4ocs 0.143 w 4.00 2.55 6 0 0 0 1Ac1om 1.270 w 35.56 55:25 0 0 0 0 4A5-2am 0.770 w 21.56 45.63 0 0 0 0 C 16A30md 0.032 0.90 2.32 169 169 150 392; 2769: 0:00 ::169 ..; 13 ;' .360 ' . .. 0 : 6 c)AED excursion: -103 Envelope loss/gain 1430 1066 12 a) Infiltration 193 55 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal (lines 6 to 13) . 1623 1351 Less erdemal.load 0 0 Less:transfer . 0 0 Redistribution 0 0 14 ..Subtotal 1623 1351 15 Duct loads 31% 496/6 497 668 Total room load 2120 2019 Air required (ofm) 95 84 Calculations approved byACCA to meet all require A wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Amk ..%Quick Calcs%DocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:29:34 Page 6 1 - wrigfltsoft° Duct System Summary pat Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466.6796 Email:_ QUICKCALCS ,AOL.COM Project For: THE ROYALE WYNNE DEV., FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply /: return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50. in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250: in H2O 0.286 in/100ft 1160 cfm Cooling 0.50 in H2O O in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm 175 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diarrt (in) H x W (in) Duct Matl Actual Ln. (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 OxO VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 Ox0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 . 0.343 7.0 OxO VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 6.371 6.0 Ox 0 VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 ` 7.0. Ox 0 VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.485 4.0 OxO VIFx 8.1 95.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 OxO VIFx 31:7 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 Ox 0 VIFx 18.1 115..0 st1 LAUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 WIC c 203 3 8 0.309 4:0 Ox 0 VIFx 26.6 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 630 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 . 1119 0.286 802 16.0 0 x 0 VinlFlx wri htsoft° 2017-Apr-1017:29:35 "MCA9 Right -Suite® Univer"sal 2017 17.0.14 RSU08101 . Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design .. Veloc . Diam H x W Stud/Joist . Duct , Name Size (in) (cfm) . (cfm) (ft) FIR (fpm) ., .(in) (in) Opening (in). Matl Trunk rb1 Ox0 1160 11160 0 0 0 0 Ox 0 VIFx -�J{�-- wri t° 2017-Apr-10 17:29:35 htsof f 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick CalcslDocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N