Loading...
HomeMy WebLinkAboutConstruction Layout SurveyLEGAL DESCRIPTION: THE SOUTH 32 FEET OF LOT 30 AND ALL OF LOT 31, BLOCK 2, INDIAN RIVER ESTATES UNIT ONE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE 43 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA IF O U J 0 w LL 2 0 vv 3 o� O 0 dw a6 o6 Nw I m m w o � J .�.. LO LJI w z W 0 U O N ® U OO 0 O 00 00 zz 1 w z � J N Ow ILs 0 wa zw 00 0 V x w� U 0 I� wxo Flo OM '; i 1 \ I \ I IRRIGATION WELL PIPE I I I I I � I N� I Z / W 0 N? \ Z Vl� 00 ? / z OW \� O} W N>F / NJ KF W wa xCL x �z a/ ow �w a o a o z w¢ w° a o� of ../moo zw z x 0 Vr ° W ¢mf C °o W� 3W Mi 0 ° oQo zo zO 3 ZO O O_ W O w� ¢ �� x 4z ��°� �� wz wo a O = M � p� U t0 I w Z N V x ri 0 S 00'00'00" E (P) 300.00' (P) I o x n°x x S v'57'06" E (M) p 299.44' (M) x W _xx x O 17 �x—x -x� Icy _ � s o lz 6' HIGH WOODEN FENCE END a nx -` x x x o_ x WCF E ODEN m 2 x 2- O IS 5.3' SOUTH OF of rl�o x on: NOTE: I DID NOT FIND ANY WELL J PROPERTY LINE of PIPES ON THIS PROPERTY. 3 163.06' 0/S 8.00' 20.00 28 37' o '00, �'F ��/CAA _� ;tl N NOTE 1: 9 Aa 0<1 x Y PROPOSED 1 STORY CONCRETE PA 0 BLOCK STRUCTURE 16 FEE' BY 20 FEET 00, 9.2' O PROPOSED FINISHED FLOOR ELEVATION IS TO Ayr MATCH EXISTING '"FUSE o ELEVATION = 102.22. z PROPOSED CONCRETE COVERED PATIO i 8,00 FEET BY 16.00 FEET / M w / / o `-9 7- WOODEN SHED O 3 176.81' O/S —� x ° x / / COVERED CONCRETE TIKI BAR a w a>F 0 W w00 w� a wz WO "n z oZI} N F rnw oa a° oa Ww O w U w w SEE CONCRETE NOTE 1 DRIVEWAY DIRT DRIVEWAY r — — APRON 8.00' A 20.00' W I90 O w x m N U a wz n g0O0 O w 0 w w � zW 00 Qmoll LL i g O N 0 \ w� 3Uz�i mti j0 z p0wW wVK 0 Q N O Z o a °o \ 03\ HGH WO DEN FENCE N $9°5610" W (M) IS 170.6 FEET LONG N 90'00'00" W (P) 300.00' (P) o i 0o I I I IRRIGATION WELL PIPE w / \ N J \ O U� 0 Li / ®1 ® a a / \ 0 wa / \ w0 \ U \ x wD W W m BRADLEY STREET (50.00' WIDE RIGHT-OF-WAY) ABBREVIATIONS: A/C = AIR CONDITIONER (C) = CALCULATED (C.F.T.) = CALCULATED FROM TRAVERSE �= CENTERLINE C.B.S. = CONCRETE BLOCK STRUCTURE C.L.S. = CONCSTRUCTION LAYOUT SURVEY E/P = EDGE OF PAVEMENT E.O.W. = EDGE OF WATER E.F.B. = ELECTRONIC FIELD BOOK EL. = ELEVATION FIRM = FLOOD INSURANCE RATE MAPS FND. = FOUND (M) = MEASURED N.G.V.D. OF 1929 = NATIONAL GEODETIC VERTICAL DATUM OF 1929. N.A.V.D. OF 1988 = NORTH AMERICAN VERTICAL DATUM OF 1988. o --- —� 11.0, 0 50.1' m o vi LIGHT POST I N PLANTER WITH I 0 z CONCRETE APRON I � �-, I_ NOTE: THERE IS 2341 SQUARE w FEE AVAILBLE FOR m W D' 4 UNOBSTRUCTED AREA.. Li w ROPOSED SEPTIC TANK < O c r_� 7.2 ��-EXISTING SEPTIC TANK I N 40 J AND DRAINFIELD IS TO BE REMOVED m 0 72.64' O/S o• N o 50.3' — _ _ J 1 1.0' cq a o ^p x Z ^p0 a ¢a 000 x t a w w C N W H s � boa a w z= 3 om w1 0^�� SET MAG NAIL IN DISK ROLLINS PLS 4945 a SITE BENCHMARK ONE ° �' / �I ELEVATION = 100.14 LLJ a 3 W 0 cl LLi IWW Z 3 w Zb w Q O I o 0 w 0 w C3� man °i o 00 00 I Sa 0� I N� SET MAG NAIL IN DISK ROLLINS PLS 4945 SITE BENCHMARK TWO ELEVATION = 100.00 N.T.S. = NOT TO SCALE O/S = OFFSET P.C.P. = PERMANENT CONTROL POINT (P) = PLAT P.O.B. = POINT OF BEGINNING P.R.M. = PERMANENT REFERENCE MONUMENT (R) = RECORD P.C. = POINT OF CURVATURE P. 1. = POINT OF INTERSECTION S/W = SIDEWALK T.O.S. = TOE OF SLOPE T.O.B. = TOP OF BANK MIN. SETBACK REQ. FRONT SIDES I CNR SIDES A REAR 1 ZNG. 1 TECH. cJS t A �g U Mrs J y', cn E a. 3 5oCL Oc m W 10 u- a 0z CO 0 I+a f 3 I Inch=20 tL NOTE: THE BEARINGS ARE BASED ON THE WEST RIGHT-OF-WAY LINE OF PINETREE DRIVE AND THE EAST LINE OF LOT 31 BLOCK 2 ACCORDING TO THE PLAT OF INDIAN RIVER ESTATES UNIT ONE (SEE LEGAL DESCRIPTION) WHICH BEARS SOUTH 00'04'41" EAST. CERTIFICATIONS AS PROVIDED AND WORDED BY CLIENT CERTIFY TO: 1) CHRISTOPHER AND ME.ISSA HUTCHINGS BENCHMARK REFERENCE: SET MAG NAIL DISK IN DISK ROLLINS PLS 4945 NEAR THE WEST EDGE OF PAVEMENT OF PINETREE DRIVE 9.1 FEET NORTH AND 23.3 FEET EAST OF THE SOUTHEAST CORNER OF LOT 31, BLOCK 2, OF INDIAN RIVER ESTATES UNIT ONE. ASSUMED AN ELEVATION OF 100.00 ON TOP OF THIS NAIL. (SITE BENCHMARK TWO) ELEVATIONS BASED ON ASSUMED AND SHOWN THUS 1� FLOOD ELEVATION INFORMATION MAP NUMBER 12111CO277 J COMMUNITY NUMBER 120285 FIRM ZONE X DATE OF FIRM FEBRUARY 16, 2012 PANEL 0277 SUFFIX J FIELD ADDENDUM BOOK PAGE DATE BY CHECKED BOUNDARY E.F.B. 03/24/2017 R.E.R. R.E.R. SURVEY TOPOGRAPHIC E.F.B. 03/24/2017 R.E.R. R.E.R. SURVEY CONSTRUCTION 03/24/2017 R.E.R. R.E.R. LAYOUT SURVEY LOCATE E.F.B. 08/05/2017 R.E.R. R.E.R. WELL PIPES LEGEND: O = SET 5/8" IRON REBAR WITH CAP P.L.S. NUMBER 4945 • = SEE MAG NAIL IN DISK P.L.S. NUMBER 4945 UNLESS OTHERWISE NOTED. (D = MANHOLE (M.H.) ® = CATCH BASIN (C.B.) = FIRE HYDRANT (F.H.) F=--1 = WATER METER (W.M.) = WOOD POWER POLE (WD. P.P.) = CONCRETE POWER POLE (CONC. P.P.) = ANCHOR AND GUY WIRE — — = OVERHEAD WIRES —VA— = NOT TO SCALE — X — = FENCELINE NOTES: 1) LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENTS, OWNERSHIP AND/OR RIGHT- -OF-WAYS OF RECORD. 2) NO UNDERGROUND OR INTERIOR IMPROVEMENTS WERE LOCATED EXCEPT AS NOTED. 3 LEGAL DESCRIPTION AS SUPPLIED BY CLIENT. 4 BUILDING TIES ARE 90' OR RADIAL TO THE PROPERTY LINE. 5) ALL EASEMENTS SHOWN ARE PER RECORD PLAT UNLESS OTHERWISE NOTED. PLOT DATE AND TIME: 08/28/2017 9:55 AM EST LOT SQUARE FOOTAGE: 0.674± ACRE SCALE: 1 " = 20' DATE OF LAST FIELD WORK: 08/05/2017 I HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON COMPLIES WITH STANDARDS OF PRACTICE FOR SURVEYS AS CONTAINED IN CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. ROLAND 6ATE PROFESSIONAL LAND SURVEYOR FLORIDA REGISTRAI:ION NUMBER 4945 NOT VALID WITHOUT TIDE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. JOB NUMBER: RR170249ST