Loading...
HomeMy WebLinkAboutDrawing Air Calcs.Job #: 1645 Performed by Chris Bateman for: Allen Residence 5507 Hickory Dr Ft. Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 103 Page 1 Right-Suite® Universal 2021 21.0.08 RSU29066 2021-Nov-02 11:07:45 ...VAC\5507 Hickory Dr PSL Prop.rup N Level 1 Garage Utility Bed 2 WIC 2 Linen Bed 3 Cabana Bath Hall Kitchen Great Room Dining Room Master Bed Hers His Master Bath Foyer Nook WIC Wtr Clst 10 x 10 128 cfm 10 x 10 128 cfm 10 x 10 153 cfm 8 x 4 4 cfm 10 x 10 131 cfm 10 x 6 109 cfm 12 x 8 174 cfm 12 x 12 113 cfm 14 x 14 288 cfm 30 x 18 1082 cfm 8 x 8 111 cfm 8 x 4 31 cfm 8 x 4 34 cfm 14 x 8 254 cfm 10 x 6 93 cfm 10 x 6 97 cfm 6 " 6 " 6 " 6 " 6 " 4 " 4 " 4 " 6 " 5 " 7 " 18 " 6 " 6 " 16 x 16 8 " 10 x 6 98 cfm 6 " 8 x 8 111 cfm H/W 100 CFM 6" Duct 6"Exhaust Vent F 100 CFM 6" Duct 6"Exhaust Vent 10 x 6 60 cfm F 8 x 4 43 cfm 4 " 5 " 12 " 14 " 7 " 12 " F 50 CFM 4" Duct 4"Exhaust Vent DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE 12 " 9 " 14 x 14 301 cfm14 x 14 12 " 6 " 6 " 8 x 8 114 cfm 8 x 8 114 cfm