HomeMy WebLinkAboutInsulation - installation Certificate 11-21-18Professional Insulators of South Florida
V? FTC Insulation Installation Certificate
s2 ttc eDcepat'o:nr St Lucie Countv Datt/Bloc6. October 4, 2018
Address: 6 Peru Project:
The undersigned hereby certifies that insulation has been installed in the above described property as follows:
1. Exterior CBS walls have been insulated with:
Spray -on Cellulose
Thickness in inches:
Fiberglass Blankets
Manufacturer:
Fi Foil
Rock Wool Blankets
Density:
X
Aluminum Foil
R-Value:
R 4.1
Rigid Board
Polystyrene
Other
2. Ceilings (level) have been insulated with:
Spray -on Cellulose
Thickness in inches:
11.1"
X
Fiberglass Blown
Manufacturer:
Climatepro
Rock Wool Blankets
Densitv:
Aluminum Foil
R-Value:
R-30
Polyurethane
Open Cell SPF
Ceilings (Inaccessible) insulated with:
Spray -on Cellulose
Thickness in inches:
9.51,
X
Fiberglass Blankets
Manufacturer.
Johns Manville
lIgnition Barrier
Density:
Fiberglass Blown
R-Value:
R-30
Cellulose Loose Fill
Open Cell SPF
3. Interior kneewalls have been insulated with:
Fiberglass Blankets
Thickness in inches:
Fiberglass Loose Fill
Manufacturer:
Rock Wool
Density:
Fiberglass Blown
R-Value:
Cellulose Loose Fill
Open Cell SPF
4. Garage partition walls of A/C living area have
X
Fiberglass Blankets
been insulated witb;
lRock
Wool
Thickness in inches:
3.5"
Iftlyurethane
Manufacturer:
Johns Manville
Spray -on Cellulose
Density:
Open Cell SPF
R-Value:
5. The following have been insulated:
.-.� gtbcor�� ••.-.
s� SEA
,. -
•%;gyp; ........1 A`J:
WymNE BuiLDING CORP.
General Contract(Builder
CBC1 41
Competency #
Professional Insulators of South Florida, Inc.
Insulation Contractor
}
COUNTY `:A,_
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
RECEIVED
NOV .2 17018
Permitting De
St. Lucie County1enr
Date:, 11 g
Permit #: S L C
Contractor: V V a , I $'�10OnCn
Job Address: ��'' , F °`` ' 3
Construction: (kfew Construction —Complete ) Existing —After Addition
House Infiltration Test tessult SLC Climate Zone 2
CFM (50)'= 3 Test Date:
Volume = 1 3 -1® -5.1
ACH (50) = CFM (so) x 60 / Volume =
Passing results must be & ACH (50) or less
Mechanical Ventilation required less than 3 ACH
(Pass ( ) Fail
. FBC, Energy
The>building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in "Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blowerdoor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal ,envelope:
FBC,' Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour When tested with a blower door at a
`'pr0isdre of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testine.Comcanv,
Company Name: Pro -Duct Services Address: 1915 Rio Vista Dr.," Ft Pierce 34949
1'-herebycertify that the above House infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance Vdth Section 402.4.1.2 Climate Zone 2.
"SIgnature:
PrintedName
'Martin Klein