Loading...
HomeMy WebLinkAboutInsulation - installation Certificate 11-21-18Professional Insulators of South Florida V? FTC Insulation Installation Certificate s2 ttc eDcepat'o:nr St Lucie Countv Datt/Bloc6. October 4, 2018 Address: 6 Peru Project: The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray -on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R-Value: R 4.1 Rigid Board Polystyrene Other 2. Ceilings (level) have been insulated with: Spray -on Cellulose Thickness in inches: 11.1" X Fiberglass Blown Manufacturer: Climatepro Rock Wool Blankets Densitv: Aluminum Foil R-Value: R-30 Polyurethane Open Cell SPF Ceilings (Inaccessible) insulated with: Spray -on Cellulose Thickness in inches: 9.51, X Fiberglass Blankets Manufacturer. Johns Manville lIgnition Barrier Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Open Cell SPF 3. Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage partition walls of A/C living area have X Fiberglass Blankets been insulated witb; lRock Wool Thickness in inches: 3.5" Iftlyurethane Manufacturer: Johns Manville Spray -on Cellulose Density: Open Cell SPF R-Value: 5. The following have been insulated: .-.� gtbcor�� ••.-. s� SEA ,. - •%;gyp; ........1 A`J: WymNE BuiLDING CORP. General Contract(Builder CBC1 41 Competency # Professional Insulators of South Florida, Inc. Insulation Contractor } COUNTY `:A,_ Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method RECEIVED NOV .2 17018 Permitting De St. Lucie County1enr Date:, 11 g Permit #: S L C Contractor: V V a , I $'�10OnCn Job Address: ��'' , F °`` ' 3 Construction: (kfew Construction —Complete ) Existing —After Addition House Infiltration Test tessult SLC Climate Zone 2 CFM (50)'= 3 Test Date: Volume = 1 3 -1® -5.1 ACH (50) = CFM (so) x 60 / Volume = Passing results must be & ACH (50) or less Mechanical Ventilation required less than 3 ACH (Pass ( ) Fail . FBC, Energy The>building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in "Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blowerdoor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal ,envelope: FBC,' Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour When tested with a blower door at a `'pr0isdre of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testine.Comcanv, Company Name: Pro -Duct Services Address: 1915 Rio Vista Dr.," Ft Pierce 34949 1'-herebycertify that the above House infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance Vdth Section 402.4.1.2 Climate Zone 2. "SIgnature: PrintedName 'Martin Klein