Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
_p - wrightsbW Project Summary oat Entire`House By. QUICK CALCS, INC. 317 St. LUCIE LN., FT. PIERCE, FL 34946 Phone: M:466-6799. Fax 772466-6796 -Email: For: THE ROYALE WYN EV., FT PIERCE, FL Notes. Design Information Weather. Fort'Pierce, FL, US Winter Design Conditions. Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 °F Inside db 28 OF .•Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 19898 Btuh Ducts 6092 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Infiltration Method ' Construction quality Fireplaces Simplified Average Heatingg. Coolin Area (ft2). 1720 171 Volume (ft3) 14231 14231 Air changes/hour 0.38 0.20 Equiv. (cfm) 90 47 Heating. Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air.flow Air flow factor Static'pressure Space thermostat_ Capacity balance point = 35 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 0 1160 cfm . 0.045 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90. OF 75 OF 15 OF 50 %. 61 gr/lb Sensible Cooling Equipment -Load Sizing Structure 18607 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh (none). Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 26420 Btuh Latent Cooling Equipment.Load Sizing Structure 2182 Btuh Ducts 2516 Bfuh Central vent (0 cfm) 0 : Btuh (none). Equipment latent load 4697 Stuh Equipment total load 31117 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary - Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible- cooling 24360. Btuh Latent cooling 10440 Btuh Total cooling. 34800, Btuh. Actual. air flow 1160. cfm. :Air flow factor 0.042 cfm/Btuh Static pressure 0.50 ,in H2O Load sensible heat ratio 0.86' Calculations -approved -by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' . Right -suite® Universal 201717.0.14 RSU08101 2017-Apr-10 1 P298 J'CA ...%Quick CalcslDocumentslWYNNE-ROYALE-REVISED.rup Calc = MJB Front Door faces: N g -F- wrightsoft' Right-J® Worksheet Dat e: Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Exposed well 180.9 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 343.0 ft 5 Room area 1719.5 ft' 343.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2 °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs 0.143 n .:4.00 2..55 577 524 2096 1333 72 72 288 183 1A-c1om 1270 n' 35.66, 34.77 16 0 565 553 0 0 0 0 4A5-2om .. 0.770 : n 21.66 19.31 . 38 0 815 730 0 0 0 0 W 13AAocs 0.143 ne 4 00 2.56 34 34 136 86 0 0 0 0 11 . '13AAocs 0.143 a 4.00 2.55 112 67 269 171 0 • 0 0 0 1Ac1om ".; 1.270 e 4 35.56 87.29 24 3 848 ; 2082 ' 0 . 0 0 0 �D 11D0 r 0:390 , e' 10:92< 1131 , . °' . 21 ..21 229 , .: 238 .: 0 0 "p .. ;;p. w 13AAocs 0.143 se 4.00 2.65 23 23 91 58 0 0 0 0 13A-0ocs' :_ 0.143 s ; 4.00 255 456 449 1798 1143 232 ='. 232 r 929 591: 1-G 1Ac1om ;.: ` . 1.270 s 35a56 34.77 , 7 14 247 . 241 0 = 0 yJ k� 13AAocs 0.143 w 4.00 2.55 290 217 867 551 112 79 318 202 1A-clom 1.270 w 35.56 55.25 33 4 1162 1806 33 2 1162 1806 I-G 4A5.2om 0.770 w 21.56 45.63 41 4 880 1862 0 0 0 0 F g12C 0sw,•'; ..: .. > : 0:091 -=:. 1 1:28 :, _ : ;,224 ' . ; .224 ,:571' .;, 287 .: ' 0 ,` ' • 0 0 C 16A-30md 0.032 - 0.90 2.32 • 1720 1720 .1541 3989 343 ... 343 307 796 '.:0:989 . - ' • • 27.0 • D;00 .: , .1120 :: .181 `5010 . 0 , . 343 52 A440 X. 6 c)AED excursion 465 668 Envelope loss/gain 17124 15595 4444 4245 12 a) Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 - 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 19898 18607 5218 4463 Less wdemal load 0 0 0 0 Less 0 0 0 0 .transfer Redistribution 0 0 0 0 14 Subtotal 19898 18607 5218 4463 15 Duct loads 31% 49% 6092 . 9204 31% 49% 1598 2208 Total room load 25990 27810 6815 6671 Air required (cfm) 1160 1160 304 278 of Manual J. A -FW wrigfitsoft• , Right -Suite® Universal 2017 17.0.14 RSU08101 ... \Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:29:34 Page 1 wrllghtsofr RighWO Worksheet • °b _ Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM - 1 Room name WIC M. BATH 2 Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 Ty Construction . U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�'F) (Btu 2) or perimeter (ft) (IS tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13Am.4ocs. 0143 -,n: 4.00 2.55'. 0 q 0. 0 0 0- 0 -.0 1Acloni : 1270 n 35:56 34.77 " 0 . 0 0 0 0" 0. 0 0' r4A5 tom:. 0.770 .: n 21:56 19.31 0" 0 0 0 '0 0 0: 0 W ,. 13A-4ocs . 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A-flocs- 0143 e. 4M. 2.55 '0 0 0 0 0 .01 0 '.0 1Ao1om; 1270 a 35 56 87:29 0 0 U, 0 0 0. 0 0 ;0390 a,' 1092 .11 31; 0'. 0. ' ... O y," .. 0 : O c -,.;0„ W 13A4ocs 0143 se 4 00 255 0 0 0 0 0 0 0 0 13A-0acs : 0143 s ' 4 00; 2:55 0 0 0 0 64 :. 57 : 226 145 :1A c1om. 1:270 -, � 35:56. 34:77 0 0 . 0 0 :: 7 7 13A4ocs 1A-ciom 0.143 1.270 w w 4.00 35.56 2.55 55.25 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' G 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 F ...:,12C-0sW=c' • , _; _' '0:091 . -.: 255; 12ti , p .:.. 0 :... '., :0 ;. ,. 0 i0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 56 56 50 130 F .:' 22Atpl r Q:989 ;':_,:, '`2XOR ' .. 0:00.:. ' . 63-,0',.,. 6 c)AED wcursion -10 -39 Envelope loss/gain 56 136 747 477 12 a)Infiltration , 0 0 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ ti 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 136 866 511 Less eAemal.load 0 0 0 0 Less :transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 15 Duct loads 31% 49% 17 . 67 31% 49% 265 253 Total room load 74 203 1131 764 Air required (cfm) 3 8 50 32 all reauirements of A&A' wcightsoTt- Right -Suite® Universal 2017 17.0.14 RSU08101 ...1Quick Calcs%DocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N 2017-Apr-1017:29:34 Page 2 - wrightsoft' RighWO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fa)c 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: By: 1 Room name KrrCHEN BATH . 2 Exposed will 0 ft 5.0 ft 3 Room height 8.0 ft , heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 172.0 ft 9.0 x 5.0 ft 5 Room area 172.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area - (ft2) Load number (Btuh/ft2L°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flogs 0.143 n .. 4:00 2 55 0 0 0 ': 0 40, 40 '160 102 1A-0onn .1.270 n 35:56 34.77 0 0 0 .0 " 0 10. :0 0 '4A5-2om:'. 0.770 , n. 21.56 19:31 0: 0 0 0 0 0 :' 0 0 W 13A.-0ocs , 0.143 ne 4.00 2.55 0 0 0 0 0, 0 0 0 11 13A-4ocs 0,143 e 4.00 2:55 0 0 0 0 0 '0 0 0 1Ac1om 1.270 e , 35.56 87.29 0 .0 '0. 0 0 0 0 ".0 , 11D0 0.390._ e..• 10,92 . 11.31 .0 '. 0 `.. 0 .. ., 0'. 0 0 • W 13AAocs 0.143 'se 4.00 Z55 0 0 0. 0 0 .0 0 0 VI/ 13A�locs ;.0' 1A�1om.: 1.270 s.' 35 56 34 77 . 0 0 0 0 .:.. 0 `- : 0 ILI13A4ccs 0.143 w - 4.00 2.65 0 0 0 0 0 0 0 0 1Ac1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56. 45.63 0 0 0 0 0 0 0 0 0.091, .� .- . ;2,55 , .' 1:28 .:. ..: �64 ._ : .:.:64 > :.163 ' : : 82 0 + , 0 ' .:`.0 :.. 0: C 16A-30md 0.032 - 0.90 . Z32 172 172 154 399 45 45 , 40 104 F , 22Atpl 27:09 .:.6:00 , :172: 0 :.. 0 ... 0 ... 45:::. . , '- 5 :.. 138 .; ;`0: T. 6 c)AED excursion -176 -16 Envelope loss/gain 317 305 339, 190 12 a). Infiltration . 0 0 74. 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 2000 0 Subtotal (lines 6 to 13) 317 2305 413 . , ' 211 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 31% 490/6 97 1140 31% 49% 127 104 Total room load. 414 3446 540 315 Air required (cfm) 181 144 ' 24 13 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. .�GZ`A wrightsoft� MW-Apr-1017:29:34 Right -Suite® Universal 2017 17.0:14 RSU08101 Page 3 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Cale = MJ8 Front Door faces: N wriohtsoftl Right-JO Wo rksheet' Job: Entire HouseDate:By: QUICK CALCS, INC. 317 ST LUCIE LN., FT PIERCE, FL 34946 Phone: 772466.8799 Fax 772466-6796 Email: OLACKCALCS@AOL..COM I Room name BEDROOM 2 ENTRY 2 = edvall 42.6 ft 6.3 ft 3 height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 204.0 ft 204.0 ft2 1.0 x 97.5 ft 97.5 ft2 Ty Construction U-value. Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ffl�-*F) (Btu 2) or perimeter (ft) (Bt h) or perimeter (ft) (Bt h) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat C.1 6 .141 '113A4ws AA--06nn - _41A5-26m: 0.143 -127.0 0.770 n n'* : n .4.00: 3&56 11.66, 2 55 34.77 19.31 - 112 0 0 112 0 0 448 0 0. .:285, .0 0 0 0 0 .0 0 0 0 9 0 -0 W 1-3A4ocs .0.143 ne 4.00 2.55 23 23 91 58 11 11 45 29 11 -UA466s, 0143 ...:e: - 4001. -255 72 `24 .48 193 123 40 .19 .76 .,!,Q 29 -�g W ;-,2682 .-,o 0 A1D01'--,:, 10.62 ICM A, 70 �21 w 13AAocs 0.143 se 4.00. 2.55 23 23 91 58 0 0 0 0 -.-0.143 4-00 2.*65 112 112 446 '-28 0 6, 1.216 s 3ir% X77' '0 0, 'A VN 13AAws 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 W 35.56 55.25 0 0 0 0 0 0 0 0 0.770 w 21.56 45.63 0 0 0 0 0 0 0 .-:,0.()91 :2.55 .1 28- -0- ' -0 ;''W, 104 04 Y,2 33 C 16A-30md 0.032 6.90 2,32 204 204 183 98 98 87 226 P, I A689 A-."g 27 1 AGO,.. ' 204 43 E .117.9 ;9.8;'-. `.6' A j, R 6 c)AED excursion -90 -50 Envelope loss/gain 3481 3273 878 625 12 a), Infiltration 634. 179 95 27 b) Room ventilation 0 0 .0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 p Subtotal pines 6 to 13) 4115 3452 974 651 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal - 4115 3452 974 651 15 Duct loads 31% 49% 1260 -1708 31% 49% 298 322 Total room load -53761 51591 12721 974 Air required (clim) 1 240 215 .9 411 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w -Fjfwrigpiltsoft• 2017-Apr-10 17:29:34 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ... \Quick CalcskDocUmentskV%rYNNE-ROYALS-REVISED.rup Cale = MJ8 Front Door bees: N - - wrightsoft°Right-J®Worksheet Job: Entire House Date' sy:. " QUICK CALCS, INC.. 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 "Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/D)NING 2 3 4 5 Bq3osed wall Room height Room dimensions Room area 6.0 ft 8.0 ft heat/cool 7.0 x 6.0 ft 42.0 ft2 48.0 ft 8.9 ft heat/cool 1.0 x. 528.0. A 528.0 W Ty Construction number U-value (Btuhlft2- F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 1A c1om. AA5-2cm .: 0143 .1270 :" 0.770 n n : rr 4.00 3556 21 56 Z55 . 34.77 .. 19:31' 0 0 0 0 0 0 0 0 0 0 .0 0 249 0. " 38 • 211 0 • .0 846 0 816 538 0 MO 11 W 13AAocs i3A-4ocs 0.143 0143 ne" e' 4.00 4.00 2.55 2.55 0 0 0 0 0 0 0 0 0 0. 0 0' U 0 0 0 1A�1om 13AAocs 13A 4acs' , 1A,c1om,;r 13AAocs IA-clom 4A5-2om 1 270 0390 0.143 Q 143 1' 270 0.143 1.270 0.770 e:, _ :e=: se s ` ; s w w w 3$.56 ,10:92 4.00 4 00; 35:'56' 4.00 35.56 21.56 87.29 . 11i31 , 2.55 2'S5 . 34477 2.55 55.25 45.63, , 0 0.. 0 --48 , 0 0 0 0 ,:56 .0. 0 0 48 0 0 0 0 0 - ; . 0 0 '. 192 0 0 0 0 143 - _ 0 : 0.: 0 : • 122 . 0 0 0 0 72 , 0 -0' 0 : -0 .', 0 178 0 41 0S ' 0 .•. .' 0 0 " 0 137 0 2 0', 0 .. p 0 549 0 880 0 .0, 0. 0 349 0 1862 .. :r0.. W V�1 F-G �G C 16A3Wmd 0.032 - 0.90 2.32 42 42 38 97 528 528 473 1225 F.tpl :,,"".•::. .:, s0989• -': 27..69' ..,,0:00 42`. •. ;' :6.: , 166° '." :0`. .:528' 48: 7329 :?0 ,I ". 6 c)AED exursion -22 305 Envelope loss/gain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal Qines 6 to 13) 628 294 5687 5232 Less exfemal load 0 0 0 0 14 15 Less:tiansfer Redistribution Subtotal Duct loads 31% 49% 0 0 628 192 0 0 294 146 31% 49%1 0 0 5687 1741' 0 0 5232 25W Total room load Air required (cfm) -7 820 37 440 , 18 7428 332 7821 , 326 Calculations approved byACCA to meet all requirements of"Manual J 8th Ed." wright§oft' 2017-Apr-1017:29:34 Rlght Suite® Universal 2011 17.0.14 RSU08101 Page 5 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Cale = MJ8 'Front Door faces: N k - +- wrightscift° Right-J® Worksheet Job, _ Entire House Date: sy. QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 2 Exposed wall 13.0 ft 3 Room height 8.0 ft heaticool 4 Room dimensions 13.0 x 13.0 ft 5 Room area 169.0 ft2 Ty Construction U-value. Or HTM Area (ft2) . Load, Area Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 13AA0cs 0.143 ' • n A00 2;55 10.4 88 353.. 224 : 1Aclom. 1.270 n' 35 56 34a77 16 ' 0 565. '553 4A52om• ; 0.770 : n 21.56 . 19:31 .0 0 0 _ '. 0 W 13A-4ocs 0.143 ne 4.00 2.66 0 0 0 . 0 I—G 13AA cs 0.143 0 4.001, 2 55 '0 0 0 0 1Ac1am : 1.270 35 56 87-29 0 0 0 0 .�_. 11D0.. • .' ; 0.390 . e':: ..10;92 11:31 0 . :,; 0 0 0 :.'. W . 13AAocs 0.143 se 4.00 2.55 0 0 0 0 ,•_ 73A-0ocs 0:143 s ;, 4.00 255 0 '1':270 .. "SA 35;56; 34 Tl p 0 : p 13AAocs 0.143 w 4.00 2.55 0 0 0 0 IA-clom 1.270 w 35.56 55:25 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 128 0 : `.' ::. ;... 0 .: : i 0 ,. : :.. 0 C 16A30md 0.032 - 0.90 2.32 169 169 151 392 F 22P�tpl '.. > :: , : , :>:0:989 . _ 27:69. , ' 0:00 169 ..: , ::13 6 c)AED excursion -103 Envelope loss/gain 1430 1066 12 a) Infiltration 193 55 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal (lines 6 to 13) 1623 . 1351 Less wdemal.load 0 0 Less:transfer 0 0 Redistribution 0 0 14 Subtotal 1623 1351 15 Duct loads 31% 496/o 497 668 Total room load 2120 2019 Air required (cfm) 95 84 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. .4CP. 4jJ- wrightsoft- 2017-Apr-10 17:29:34 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ..\Quick Caics\Documents\WYNNE-ROYALE-REVISED.rup Calc ='MA Front Door faces: N -�- wrightsoft° Duct System Sumlrnary pat : Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Project intormation For. THE ROYALE WYNNE DEV., FT. PIERCE, FL Heating I 'Cooling' Externalstatic pressure 0.50. in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply /: return available pressure 0.250 / 0.250. in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.286 in/100ft 0.286 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 175 ft SupplyDetail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BAT h 540 24 13 0.351 4.0 Ox0 VIFx 27.3 115.0 st1. BEDROOM h 3408 152 139 0.286 7.0 Ox 0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 . 0.343- 7.0 Ox0 VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 0.371 6.6 OxO VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0 Ox 0 VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.486 4.0 Ox 0 VIFx 8.1 95.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 OxO VIFx 311 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 OxO VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 OxO VIFx 18.1 115.0 st1 LAUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 OxO VIFx 21.6 115.0 st1 wlc c 203 3 8 0.309 4.0 Ox 0 VIFx 26.6 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H: x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 639 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 . 1119 0.286 802 16.0 0 x 0 VinlFlx wri htsofte 2017-Apr-1017:29:35 9 Right -Suite® Universal 2017 17.0.14 RSU08101 . Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED:rup Calc = MJ8 Front Door faces: N 0 Return Branch Detail Table Name Grille Size (in) Htg (cfm) . clg (cfm) TEL (ft) Design FR Veloo (fpm). , Diam (in) H x W (in) Stud/Joist . Opening (in). Duct .' Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx 2017-Apr-10 17:29:35 . ;,. wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJS Front Do6r faces: N