Loading...
HomeMy WebLinkAbout3412 Trinity Lot 31 blower door and duct blast.pdfInformation Builder: DR HORTON Address: 3412 TRINITY City: FORT PIERCE Butt Leakage Test Results System 1 System 2 System 3 Sum of any additional systems Total of all systems Duct Leakage Test Report Prescriptive or Performance Method Permit # nmunity: CREEKSIDE Lot: 31 Unit: State: FL Zip: 34945 Live Method 0 Performance Method cfm25 & rescriptive Method cfm25 (total) To qualify as "substantially leak free" Qn must be less than or equal to 0.04 cfm25 if air handier unit is installed. If air handier unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the cfm25 requirements in accordance with Section R403.2.2 4_ 4 - 1$28 = 0.02 Qn Total of all systems Total Conditioned Square Footage ��j✓'� PASS 11FAIL Testing Company Performance Method cfm25 (put or Total) qualify as "substantially leak free" Qn must not be greater than the iposed duct leakage Qn specified on Form R405-2014 Leakage Type selected on Form R405-2014 (Energy Calc) Qn specified on Form R405-2014 (Energy Colc) Company Name: SUN SEAL LLC Phone: 321-412-0035 1 hereby verify that the above duct leakage testing results are iY accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive MetHod or Performance Method. Date of Test: 03/01 /2022 Signature of Tester: r Printed Name of Tester: DANIEL MURPHY License/Certification #t 5066440 issuing Authority BPI Job Information Builder: DR HORTON Address: 3412 TR1N City: FORT PIERCI Envelope Leakage Test Report (Blower Door Test) R405.4.2.1 Compliance Community: Permit # Unit: State: FL [Air Leakage Test Results Passing results must be 7ACHj5QJ or less 975 x 60 = 14381.6 = 4.0 CFM(50) Building Volume ACH(50) Zj PASS FAIL Lot: Method for calculating building volume- 0 Retrieved from architectural plans lode software calculated Q Field measured and calculated When ACH(SO) is less than 3, Mechanical Ventilation installation must be verified by building department. (Certification of Test Results K4UZ.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be nerfarmPd at anv tr,„Q eft——ml;.,., f Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 03/01 /2022 signature of Tester:'L_ Printed Name of Tester: DANIEL MURPHY License/Certification # S066440 Issuing Authority