FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
Permit #: , f `7l/ —63W
Construction: (� New Construction
House Infiltration Test Results SLC Climate Zone 2
CFM (50) _ / 13.E
Volume = 15-995'
ACH (50) = CFM (50) x 60 / Volume = `7 2.
Passing results must be & ACH (50) or less
Test Date:
Mechanical Ventilation required less than 3 ACH
M Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to
penetrations of the
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the
accordance with Section M1507.3.
Testing Company
Company Name: Y�/G� Address: lJ`7' �0�/✓t ���, i� 1 �22
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accpfdance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Nam
License/Certification #: -;,rp 3 1.6-le
FILE COPY
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
772462-2165 Fax 772462-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
Date: j0 Permit #: r 7,/ 03% � Lot #: 7/
Contractor: Address: �7S`-.)
Construction: post Construction Test ❑ Rough -in Test
Test Conditions: / Jn
Date: <o 4 Floor Area (ft2): /Ali
Time: / Primary Location of Supply Ductwork
Indoor Temperature (F): Primary Location of Return Ductworkj02.
Outdoor Temperature (F):
Total Leakage Test (Outside)
Duct Leakage: ❑ Default ❑ Prop. Leak Free ❑ Proposed On =
Test Pressure: 2f (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: ass ❑ Fail
Installed Pa `�*
Total Leakage (cfm): `�I, 2—
Total Leakage per 100 sgft: 23
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft.
Testing Company
Company Name:
qs7J) �P yr Se �J✓� �o
Address:i��//��
I hereby certify that the bove Duct Sealing Leakage results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with
Section R403.. .
Signature: /
Printed Name: ����iG License/Certificate #:�31��