HomeMy WebLinkAboutRevisionOFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT# 1111'00C
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
AD
DRESS )� C-(
�)z L 3 4 IY K -2
DETAILED DESCRIPTION OF PROJECT
REVISIONS: //Jl
IIIII 1 111,111 11110: 111 11 1
•
STATE of FL REG./CERT.
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME): _
STATE:
OWN "R/BUILDER INFO TION:
NAME:
CITY: STATE:
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
ST. LUCIE CO CERT. #:
ZIP:
ME"
FAX:
STATE: ZIP..
FAX:
SLCCC- 9123109
Revised 06130117 10
4
N
ELECTRICALELECTRICAL
1) ALL ELEC'IRiCAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70)
2011 EDITION.
2) ALL ELECTRICAL INSTALLATIONS AND EQUIPMENT SHALL BE IN
ACCORDANCE WITH THE REQUIREMENTS OF THE N.E.C. (NFPA 70) AS
AMENDED, AND ALL LOCAL & STATE CODES IN FORCE AT THE TIME OF
CONSTRUCTION:
3) GROUND SYSTEM IN ACCORDANCE WITH ARTICLE 250 N.E.C.
4) ELECTRICAL WIRING SHALL BE COPPER -TYPE THHN OR TYPE THW FOR
WIRING WITH IN BUILDING; TYPE THWN UNDERGROUND OR ON BUILDING
tF. EXTERIOR. CONDUIT SHALL BE EMT WITH IN BUILDING; PVC UNDERGROUND;
!!! GRS FOR SERVICE ABOVE GROUND.
5) SYSTEM VOLTAGE SHALL BE 120/240 VOLT, SINGLE PHASE.
6) PANELBOARDS AND LOAD CENTERS SHALL BE SQUARE "D", ITE, OR
APPROVED EQUAL.
7) ALL CONDUCTORS AND BUS BARS SHALL BE COPPER.
8) ALL MATERIAL SHALL BE U.L. APPROVED.
a _ 9) PROVIDE ALL NECESSARY PERMITS REQUIRED.
10) PROVIDE TEMPORARY SERVICE FOR USE BY ALL TRADES DURRING
t CONSTRUCTION.
a° 11) PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANELBOARD OR LOAD
CENTER.
12) PROVIDE ALL EMPTY CONDUIT WITH PULL STRING AS REQUIRED BY PHONE
CO. VERIFY ALL REQUIREMENTS PRIOR TO BIDS.
_ r 13) VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS BEFORE
!I
INSTALLATION.
h
5
O��.. .... .w.,�.w �4�,.,�.,x......m.,,,,waw.,w...�.mm.,�,«.x.,M.,..,w.�.�.w..w.+...e..,.„«..,..�.,.....,.-,....—.._.,�..<.......- .................._...
�_" Carl
E
;P ELECTRICAL LOAD CALC'S O
PER NEC
NEW METAL BUILDING
10 RECTP'S @ 180 VA 1800 VA
6 EXT. LTG @ 100 VA 600 VA
9 LED 100 VA 900 VA
MISC 1000 VA,..,
TOTAL 4300 VA
Nk
GI'I'
4300 �, _ , —tire- •,... �.f�,^^
240 18 AMPS
USE 60 AMP SUB- PANEL -25 -1*0
EXISTING RESIDENCE
2066 S.F. @ 3 VA 6198 VA
d TWO 20A APPLIANCE CKTS 3000 h
LAUNDRY 1500
j DRYER 5000
RANGE 12000
W H 4500
DW 1200
REFRIG 1200
IRR. PUMP 1800
EXISTING OUT BLDG 27300
NEW METAL BUILDING 4300
MISC 5000 d
TOTAL 72998 VA /f
FIRST 10 KW @ 100% 10000
,T
REMAINDER (a? 40% 25199.2
TOTAL 35199.2
r
A/C HEAT 6 100% 10000
TOTAL 45199.2 VA
45199.2
240 = 188 AMPS
USE EXISTING 200 AMP SERVICE C&I
ZEN
-
t
ELECTRICAL SCHEDULE
IG�LQs
N L- 4N� )-1 OO W LED LIGHT
Zv t4 i T NA�IEiI qz -- PTF\d it 7„_ r
f J�.t 1 h 1 k i4sL f L Gr EXTERIOR WALL MOUNT
_. _ I00W
SLLUCIE COUNTY- j
PLAN REVIEW &� INJ711--1:1 +M S l'�- � �� �`�
e,oc: !- ; K�iI ,i rm, ilk tip-1 d1 , GFI clt tit°I SINGLE POLE SWITCH
:DATE: -FAI WPPpe
C'
wrlc �e
ELECTel
Z!l h j I - f. �f`� � n1. _ - DA
RECEPTACLE
PLUMB:
ELECTRICAL
I / j
PLUMB::
DATE: N
CP WATERPROOF
MECN: � ,,;�-....,�,'�I� I/eaa.� f4r DATE:GROUND FAULT sa
:.-.
_, 1
r-iIAr/ YfIGE .1st d�.I r — r GFI INTERRUPTER
a�
r tI T61611 gllr
Fr� -TO-
T I r- a
tiIl�L0P I! 1 ELECTRICAL PANEL
-Pp°-�--�-�---m----•~�--�°--~�b-- Abl
ELECTRICAL METER D
1 _ter rl
i-
PAUL WELCH INC
MECHANICAL ELECTRICAL C/V/L ENGINEERING
1984S.W. BIL7MORE Sr. SUITE# f 14
PORTST. LUCIE, FL 34984
— " P'lfONE' (772-1785 - 9888 E-MAIL PVYEL'CH/1VC9A0L. CONA
PAUL WELCH, P.E. FLA REGNP..29945