HomeMy WebLinkAboutProject Information5 e ' Project Summa Job: - - weightsil Date: Enure House. By: QUICK CALLS, INC. 317 ST LUCIE..LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466$796 Email::QUICKCALCS@,AQL.COM, Project Inf •' • • For: WYNNE DEVELOPMENT THEWINDSOR; FT. PIERCE, FL " Notes: J Q-CX\\� %�e, Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db - 70 OF Design TD 28 OF Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0-cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heatingg Cool" Area. (W) 1753 1753 Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equiv.AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating.output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat. Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 0 1160 cfm . 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside.db 75 OF Design TD 15 OF Daily range L . Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment1oad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Equipmen sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh . Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh . (none) Equipment latent load 5007 Btuh_ Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual. air flow 1160. cfm, Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft• 2017-Apr-1017:19:28 f+� . Right -Suite® Universal 201717.0.14 RSU08101 Page 1 sR• k CalcMDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoft RighWO Worksheet °b Entire House Date: QUICK CALLS, INC. sY. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM 1 Room name Entire House MASTER BEDROOM 2 . Eased wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4. 5 Room dimensions Room area 1753.0 ft2 1.0 x 280.0 ft 280.0- ft2 TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/fP-`F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 1Ac1om 1.Ac1om is ;;1A-c1om : 0.143 1.270 1,270 1:270 ne ne ne .ne 4 00 35 56 35 56. '35,56 . 2.55 7043, , 70 43 '. 45.24 488 16 16 448 0 0 . 0 1795 247 581 58t 1141 488 1151 739 192 .0 — 0 _ 192 0 0 769 : 0 .. b %0 489 .0 0; =D; Vil 11 13A4ocs 0.143 se 4 00 2.55 64 41 165 105 0 0 0 0 11DO 13A flocs ., 4A5 tom, .: 0.390 0143 0:770 se sw, , sw- 1092, : 4 00 21 55 11.31 ; 2 55 27.53 23 : 437 41 23 ;396 45 248 ' ;1584' ; 893 257 1007 1140 0 56 .:: 0 _ 0 56 :. 0 0, ' 224, . 0. 0 143 :• 0 13A4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 C F 4A5-2omd :12C-0sw '`'•. .." " 16fa30md -22Prtpl 0.770 0:091 0.032 A 989 nw", .-'.. - --,< 21.56 , '2:55 0.90 27:69 36.90 1:28 2.32 : 0.'00 41 ; ' :. 308 1753 % :;1753 _ ._ 0 ... ..'308 1753 :: 153 880, " 784 1571 ; :'423Z 1505 `. : ",395 4067 ..; . U 0 280 : :. :280 0 280 :.:. ' 45 0 261 : ;: 1246 0 650 0 6 c)AED m6rsion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 htemal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 1 0 Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 FTTotal roam load" 24657 26995 6380 5794 Air required (cfm) 1160 1160 300 249 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. �A wcightsoft- RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr 10 1Page 8 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N +wrightsoft: Right4@ Worksheet Job: Entire HouseDate:. By: QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 •Fax 772-466-6796 Em'all:.QUICKCALCS@AOL.COM 1 Rbom name WIG M. BATH r2 Evosed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 A 5 Room area 63.0 ft2 61.0 ft2 Ty Construction Ll-value Or HTIVI Area (ft2) Load Area (ft2) Load number (BtufVftl,-*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gros. N/P/S Heat Cool Gross N/P/S Heat I Cool 6 _-_­13AAocs .0.143 ne 4.00 .2.55 0 0 .0 0 .56 49 '196 . 125 1A' 19M 1270 .:.35.56 70.43 0 0. 0 '6 7 - 0 247 - 488 'IN,0 .1.270 ---ne- --A6.m �"-""7043 0 0 0 -. 0 0 -45 ;O 11 Y 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 a -0 11DO 0..390 se 10.92 11.31 0� 0 o o 0 0 n n .143--- sw AD 0 0 ._0 8W. 53 .10 0­ 0 .13A4ocs 0143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-clorn 1.270 nw 35.66 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P. 2C.'0i§W, -, : "i6A-30md �- �;.. 0 001 128,:" V "0' 0 C 0.032 0.90 2.32 63 63 56 146 '61 61 55 142 T.69, 0.60 63'.. :.:0 b 0 _6 61 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 - 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ .230 0. 0 01 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 141 817 764 Less e)demal.load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 56 .0 141 $17 764 15 Duct loads 34% 530/61 19 75 34% 53%1 274 404 Total room load 75 2161 , I 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of. Manual J.8th Ed. 2017-Apr-10 17:19:28 Right -Suite@ Universal 2017 17.0.14 RSU08101 AWK Page 2 ... kCaicsXDocurrients\WYNNE-THEWINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N N w*r!4fits0'*ft* Right-M Worksheet Job: Entire Hou's e -Date: By: QUICK CALLS, INC. 317 ST..LLICIE LN., FT PIERCE, FL 34946 Phone; 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM I R . oom name LAUDRY BEDROOM 2 • EVwed wadi. 0 ft 12.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heaticool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 Ty construction U-Value , Or HTIVI Area (ftj - Load AM . (ft2) Load number (Btulfflk�*F) (BtutVft2) or perimeter (ft) (Btuh) or perimeter- (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S--- Heat Cool 6 -113AAdcs� 0. 143 Re. A.00 2.55 '0 0. 0: 0 96 80 319 203 A-6 c W1 A276 , , , Z' n6 , - ."Z� 70.Q U_ -:0 0 . "0' c"' 1'270 0 0 6 0 -7:`58f -1157A-270 - i, ..... "ne 3UQ :4&24 �0 -0 I 13AAocs 0:143 se 4.00 2.55 0 0 0 0 0 0 0 0 L--D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 ;— flocs�0 M " I - 61- I I., b 1 ... 2�66 .0 0 0 0 tom ..",04770 sw 1: 0s. 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 lXclorn 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-torn i 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 2.,"65 '0 0 a. c 16A-30md 0.032 -.0.90 2.32 36 36 32 84 180 180 161 418 :60 'o od _36 9 0 6 T� -00 4: . ..... T -332 F 1 4. v 6 c)AE D excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a)' Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less aidemal load 0 -0 6 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 so 34% 53% 541 945 FTotal T room load 51 145 1 2156; 2730 Air required (cfm) 2 61 1011 117 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -41- wrighil:saft, 2017-Apr-10 17:19:28 Right -Suite@ ' Universal 2017 17.0.14 RSU08101 Page 3 ... -THE W SOR-REVISED.rup C - k CaIcs\Documenti;\WYNNE IND alc " IVIJ8 Front Door faces: N - - wrlghtsofta . Right4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name bINING/GREAT ROOM KITCHEN 2 E�q ad wall 50.0 ft 11.0 - ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area .588.0 ft2 209.0 ft2 Ty Construction U-value Or' HTM Area 2 Load Area(ft2) Load number (Btuwft2-°F) (Btuh/ft2), or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs 0:143 ne 4.00 2.55 0 0 0 0 0 0. 0 0 1Ac1om = 1.270 ne, 3566 7043 01. eo 0 0 1. .0., 0; 0 0 1Ac1om 1.-270 ne , 35 5fi' 70.43 0 0 0 • 0 0 , . 0 0 0. 1Ac1om : :1270 . ne? . 35:5E% 45.24 0 0 . 0 0: ;. 0 .. 0 11 V�I 13A4ocs 0.143 se 4.00 2.55 0 0 0 ,:.. 0 0 0 .0 0 l-D 1100 0390 se 10.92, 1131- 0 0 0 0 0 0 0 0 73A-0ocs = 0143 sw a 4`00' 2 55 267 226 963 574 - 98 = 98 '. r392 249' :4A52om -' 0;7,70 , sw` 21:56, . <27.53 41 22 809 . - ° 1140 ::. 0 ,. 0 0 0: 13AAocs ' 1Ac1om .0:143 1.270 nw nw 4.00 35.56 2.55 45.24 178 0 137 0 549 0 349 0 0 0 0 0 0 0 0 0 4A5.2omd, 0.770 nw 21.66 36.90 41 0 880 1505 0.. 0 0 0 Osw 0 091 .::_ , : 2.55 1, 28 0 C 16A-30md, 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 485 0989 •-i= 2Tt69 .+ 0:00 588 `:-66 .-,A*;"_ : 0 :.. 209 `. dw 6 c)AED wcursion 1004 64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 : 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 '460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 66.79 1399 . 1880 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15. Duct loads 34% 530/0 2056 3541 34% 53% 469 995 Total room load 8260 10234 1867 2875 Air required (cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . - 4- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:28 A Page 4 k CalcsIDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N -r{ - wrightsoft' Right-JO Worksheet °b Entire House Date: -QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@\OL.COM 1 Room name BATH HALL 2 Fyposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room'dimensions Room area 10.0 x 5.0 ft 50.0 ft2 5.0 x 5.0 ft 25.0 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-'F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 ,, 13A-0ocs...: 1A461om 1Ao1om :1Ac1.6 ;.' 13A-4ocs 0.143 1270 1:270 A. 270 0.143 ne ne ne ..ne; 'se 4c00 35 56 35 56; `, 35,5fi 4.00 ,' 255 70 43 : 70.43 4&24 2.55 40 `0 .. .0 6 0 . 40 0 : 0 , 0 0 160 0 0 . 0 0 . 102 0 0 0 0 0 0 0 ".. . 0 0 0 0 . 0 : 0 1U 0 '. 0 0 i0 0 rt 11D0 13A flocs '. 13A-4ocs 1A-c1om 0 390 O'143 770 0.143 1.270 se sw . sw' dw nw 10 92 4 00 , . z1 5s 4.00 35.56. 11 31 _ 2 ;55 .2T..53 2.55 45.24 . 0 : :.0 ' .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ; ... o 0 0 ,0 - :0 0 0 0 ; 0 0 0 C F 4A5.2omd, 16A-30md 22Aipt:.:.,.' •:' `._ 0..770 .'0.091 0.032 A989 nw : _ . - = 21.56. 255 0.90 27:68 , 36.90 ' 1;28 2.32 0:01): - 0 C:' 0 50 S0 0: .. ` :0 50 . 5 0 . ..: 0 45. ' _138 0 00„ 116 0'; 0 25 ; 25 0. 25 <:. :0 0 22 0 0. 58 s. 6 c)AED exursion• -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 56 Less extemal load 0 0 0 0 Less transfer 0 0 0 ' 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 . 132 34% 53% 0 0 Total room load 586 381 1 1 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. - wrightsoft' 2017-Apr-1017:19:28 RightSuite® Universal 201717.0.14 RSU08101 Page 5 .:.k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrghtsoft° Right Worksheet Job: Entire House Date: • QUICK CALCS, INC. ft: 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM 3 2 E)q)osed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6. VA-0ocs 1Ac1om '-' 1A-c1om 7A�.1om ; 0.143 .1270 1 270 1270 :ne. ne, ne ne`: 4.00. 3558 35'5fi 35:56 255 7043 70:43 . . 46.-A 0 0 . .. 0 0 0 0 0 . 0 0 0 . -0 `-. ' 0 0 0 0 0'- 104 0 :- .0 16 88 0 _ 0 . 0: 351 0 , 0 : M1. 223 0. '. 739 11 W �D 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11D0 13A flocs 0390 :-0143 0.770 se sw ; ..sw_; 10.92 4:00 21.56'.. 11.31 2:55 27c53 23 8 0 23 8 0 248 32 ` 0. 257 • . 20 0 0 .: 8 .. 0 0 `.:. 8 0 . 32 0 20; :.0 V�/ Val 13A4ocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 2.55 36.90 ,1:28 0 .:. ; 88 0 88 0 =, 224 0 :.. 113 0 6 104 0 a - "',104 0 265 0 1133 C 16A-30md 0.032 - 0.90 232 92 92 82 213 169 169 151 392 0.989 2769, : ;0.00 92 ; :. .9 - 249 ' : 0 .: • 169 :14:'-0 T. 6 c)AED e)cursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) infiltration 162 46 252 71 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 1163 730 2020 1527 Less ekemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 340/o 53o/a 390 386 34% 53%1 677_T 808 Total room load 1553. 1116 2697 2335 Air required (cfm) .73 48L.127 100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . 4id-. wrightsoft2017-Apr 10 17:19:28 A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -- Duct System Summary awrightsoft pt Entire House 13,: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE., FL 34946 Phone:•7,72-466-6799 Fax 772-466-6796 Email:. QUICKCALCS@AQL.COM t e For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply [.return available pressure Lowest friction rate Actual air flow Total effective length (fEL) Heating 0.50 in.H2O 0 in H2O 0.50 .in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam . (in) H x W (in) . Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.6 st1 BEDROOM.2 c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 . st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 Ox 0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 1.50 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A . h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox 0 VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W' Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) , Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wri� htsoft° Right -Suite® Universal 20 2017-Apr-1017:19:29 )M1' f- 17 17.0.14 RSU08101 Page 1 ....k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N. M---- Return Branch Detail Table 9 Name Grille 'Size (in) Htg (cfm) Clg (cfm) TEL . (ft) Design FR Veloc . (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) , Duct, Matl Trunk rb1 Ox0. 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft, 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 k CialOIDocurnents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N