HomeMy WebLinkAboutBuilding Plan12"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
26 ga. Sv crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment installed with min. 4' side Iaps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
RIGHT ELEVATION
12
4 1 SLOPE
LEFT ELEVATION
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11491,12
26 ga. 5v crimp metal roofing attached to plywood deck using 99 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and g shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in eld. Attach
deck to trusses using attachment detail on this sheet
thick light textured
stucco on typical concrete
block construction
SCALE: 1/4" = 1'-0"
2" x 4" top plate
base —board
Fir
5/
fin
5/8" thick x 8"W cut
coral finished stucco bands
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" O.C.
2" x 4" P.T, bottom plate
\ 4" concrete slab with fibermesh OR
6"xb" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
nterlor Non—Bearina Partition
5
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. Sv crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment installed with min. 4' wide laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced C o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
dru r.J. i.e—— ...���y�yyy �// y LIIIL.A A V W irW6
block construction coral finished stucco bands
REAR ELEVATION
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 31:11651.12
26 ga. Sv crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
paced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
•4 SLOPE
din III I�I I _ � 111HR
Pi" �R
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of IS lb felt using 8d nails. Substrate
to be 19/32" CDX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
EGRESS 2'
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
4LL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
DCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP
4ND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 165 mph ultimate
Mean Roof Height:
11'-0" Roof Pitch: 4:12
Internal Pressure Cow fc ent: ±0.18
Tn�
Subjectabditg to damage from: Weathering: Negligible Termites. -Very Heavy
Width of Roof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C
ITCH
Adjustment factor for Exposure Height. 1.21 x 0.6 = 0.126 ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.6WL; 0.6DL+0.6u)L
Components t Cladding Wind Pressure (NET) Roof Zone. I. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3 4„
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
= Roof Zone I
Wall Zone: 5_ +35.8/-41.8 psf
Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
= Roof Zone 2
Walls Zone 5
Are Components an Cladding Detai ss Provided? Yes
END ZONE
Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X By Test: psi
This Building Shall Have the Following:
- = Corner Zones
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: S1 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: palf FLOOR DEAD LOAD: 1Opsf
JOB ADDRESS.'
\n �� , Q� -�bj 6
Gulf Coast Supply and MPG 5v Crimp Metal roofing FL #11651.12
24 ga. 5v crimp metal rooting attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
raced I" o_c_ at all laps and two staggered rows 12" c.c. In field. Attach
5/8" thick light textured
stucco on typical concrete
block construction
;.
EGRES
.77
'
OO
COVERED
PORCH
�•
12"
o �
®
12"
RIG��7 ELEVATION
12
4 SLOPE
LEFT ELEVATION
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4' = 1'-0'
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" and,
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
--------------
5/8" thick light textured /
stucco on typical concrete
block construction
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors,
Sliding Doors, windows & Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model
Manufacturer
Glass
Attachment method
Easpuation
Date
Design Pressure
of Approved Testa
1,2,3
t4
FL# 239.3g
Single Hun
SH-100
Impact
PGT
5/16"
1/4' din. tapeona w/ inn. 1
spaced per product approval.
min. edge distances spe:ified
3/8' penetration to be
Contractor shall adhere to
in Product approval
+ 80.0 PSF
A
16-0330.02
Overhead
Garage Door
Model 824/811
height
IL' O"mina% ylCitlit
D AB
voted " ue to navrst, with . et
unega a Wg �;R �R��.H.!,iHu m
x 1 5/r Full tired lag moves n msh braetet nmtwnirw
sort or ,mdem d,l- - GC to rtnotly adhm to prodmrt approval
rovido
10-9-21
+ 50.0/-60.0 sf
p
B
FLU 16L14.1
Fiberglass
Smooth Pro/
Jeld-Wen
Elco 1/4' din, tapcon with min 1.25' embedment at 3' max
from corners and I1.5' o.c. max thereafter in head and jambe.
+ 50.0 PSF
C
FL# 251.5
Shdin Glass
g
Door
Series 110
SGD
PGT
1" mom
Type GSA"
1/4' dia. tapcons w/ mn. 1 3/1' penetration to be
spaced per product approval. Contractor shall adhere to
min. 2 I/2' edge distarcea specified in Product approval
+ 60.0 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
ESYpuafaon
Date
Design Pressure
of Approved Teats
MtllliOn9
FLU 261.1
V x 2 3/4" x .315'
PGT
Install per fastener type and apaeings shown in Table IA and IB
in product approval on sheet b or 12.
+ 58.0 PSF
ROOF
FL# 11451.12
5V Crimp
Metal Roofing
Gulf
and
Coast Supply
manufacturing
2c ga. 5v crimp metal roofing attached to plgwood dock using a9 x 1.5"
wood screws with self sealing washer at 12" a.c. max spacing over ASTM D
(type 2) 3o Ib Pelt underlayment installed with min. 9 side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails
spaced V o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses uming attachment dotal on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
yinyl Soffit
Kaycan
Install using 2" x 2" battens at L" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
0,12' dia. x 15" lona rino shank mails with S/8" dia. head.
+55.0/-35.0 PSF
Hurricane
Panels
I have reviewed the above and approved it by my seal below. ( Architect or Engineer
of Record
12
Pinlsh Columns with
thick cut coral
finished stucco bands
C
5/8" thick x 8"w cut
coral finished stucco bands------
OL 0'-0" = Finished FI
2" x 4" top plate 11
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" O.C.
base -board 11 II �, 2 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6"xV #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
nts
RECENED
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 JUN 0l 7018
26 ga. 5v crimp metal roofing attached to plywood deck using #11 x I.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D Permitting Department
(type 2) 30 lb Pelt underlayment installed with min. 4 side laps and 6 tt
end st. .ucie County
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced V o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
11 SLOPS
COVERED
PORCH
6/8" thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
12
5/8" thick x 8% cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #111.51.12
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.a. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using Sd nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
12 nails into truss webbing.
4 SLOPE `.: ':. :: • :.`
mallow,
-1
T-11--
WLInne Building Corp.
THE ROYALE
Spanish Lakes
St, Lucie County Florida
r-2"
FRONT ELEVATION
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-O"
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: bth Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: II Wind Velocity: 165 mph ultimate
Mean Roof Height: II'-O' Roof Pitch: 4:12
Co Internal Pressure efficient. ±0_I8
SubJectability to damage from.. Weathering: Negligible Termites: Vera Heave
Width of Roof End Zone. 3'-4" Wind Speed: IL5 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.126
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.6WL; O.LDL+O.LWL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.4/-32.6 psf
Roof Zone: 2. +20.6/-51.0 par
Roof Zone: 3. +20.4/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Well Zone: 4. +35.8/-38.1 par
Wall Zone: 5. +35.8/-41.8 par
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 par
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Det-ails- Provided? Yes
Minimum Sal Bearing Pressure:2 500 psi, Presumptive: X By Test: psi
SEE PRODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENING
ROOF LIVE LOAD: 3-1 pat ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: -5 _ list_ FLOOR DEAD LOAD: 10psP
To6R.12
� PITCH
= Roof Zone I
Walls Zone 4
= Roof Zone 2
Walls Zone 5
END ZONE
Moo Corner Zones
Root Zone 3
JOB ADDRESS:� -I
FLOOR f=L/4N
CRASH POST DETAIL
AREA CALCULATIONS
TYPICAL MOTES: SCALE 1/4" = 1'-0"
N.T.S.
1. Contractor t0 verify ALL notes and dimensions prior t0
36" high by 4" diameter
Livin A/C =
g
1`f20 s . ft_
q
proceeding with work.
p g
steel crash post. Floor
Flange with 4 - 3/8"
Back
Back Porch Total -
210 S ft.
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts Into
Garage =
3ii sq. ft.
3. ALL Lumber to be used as Beam, Rafters, etc... to have
51a (3/8"t 50 Kai steel plate)
Entry =
28 sq. ft.
a minimum 1400 P S I fiber stress
0
4. No dissimilar metals to touch.
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tie beams etc., to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
O m y3/8" 2%2
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R�02.3.5.
2%2
1. ALL wood in contact with concrete shall be pressure treated.
o o
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements. PA"2''°„
12. Lowest finished floor to be set by Governing Building Department 6"
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
W.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
R302.9.1
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls Shall comply
with F.B.C. R316 - see permit info box of code edition
18. Gyypsum board material shall conform to ASTM C36, C19, C415, C514, CL30, C931
C40, C1002, C1041,C1177, C11-18, C1218, C1395, or C1391 and shall be installed
according to
the following: (FBC R702.3.5)
Masonry Beam
I" x 6" P.T. Buck Waded to
Dr
a
Thickness
Framing Max. spacing
Location Orientation Member of fastecinners Nail sizing options for
Spacing nstallation of drywall into
Maximum wood framing members
Nails Screws
2" x min. thickness
Ceiling Perpendicular 24" 7" 12" 13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
annular -ringed or Sd cooler nail
OR
/2 Walls Either 16" 8' 161, 0.080" dia. xx 1 5/8" long with
Direction 15/64" head
OR
Gypsum board nail 0.086" dia.
x 15/8" with 9/32" head.
Ceding Perpendicular 24" 7" 12" 13ga 1 5/8" lloong with 19/64" head
O
0.098" diameter x 1 3/8" long
annular -ringed or Ld cooler nail
OR
/ Walls Either 16" all 16" 0.092" dia. xx 1 1/8" long with
Direction 1/4" head
OR
Ggpsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
19, ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, AG.l and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CIIIS and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders Or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyin smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Grade
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM 1)(type 2) 30 lb relt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max
18101bs. uplift
Aluminum Drip -
Edge t Fascia
2" x 6" Sub -Fascia
Kallcan full o vent vinyyl soffit installed
using 1/8" dia shank x 15" long galv.
roofing nails with 3/8' die. head per
product approval - see chart sheet #1
5/8" thick light textured
stucco on typical concrete
block construction
3*5 bar vert. w/
30" overlap -
at each filled cell
1 I I, HU
12
4 1
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (l) 45
bar Cont. for bottom row over openings
1/2" drywall over I" x furring
strips at It." o.c. with R4.1 Pi-foll
insulation on typical 8" Block walls
All drywall to be installed per FBC R702.3.1
T and shall meet all pertaining ASTM codes.
ao Mortar to be Type "M" onlg proportioned per FBC R607.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(U #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
/ spacing at openings
4" concrete slab with fibermesh OR
VxV #10/10 WWM on L mil Visqueen over
/ clean compacted termite treated fill
ME
TYPICAL SECTION
III_.
14" x 14" Concrete footing
with (2) 45 bars cont. and 3*5
transverse bars at 48" o.c.
Total Under Roof= 22-15 sq. ft.
Total Cubic Ft = 13,1b0
2" VTR
JIL
I
Attach buck to block wall with I
1/4' dia. Elco cone screws with min. 1
1 1/4" penetration at 12" o.c. max i
and 4" max from each corner thru
Exterior face 2" x L" PT Buck 21' VTR
or wall /I JL
arles
( I I
1 2' 1
Master I Lev. 1
48 wood screws thru jamb int$b
at each hinge and 15' o.c. max an 2'
Detail at Door prior to door attachment Lay.
NTS 4" 1 2" VTR
W.C. JIL
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER. AND
SILL BLOCK PRIOR TO BUCK sher.k
INSTALLATION
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at jambs and 20" o.c. max
Exterior face at head and will per product approval
of wall -\ / \ Buck to be I" x V PT
Detail at Windows
1 1
3' 1
Kit. Sink I
I
Kitchen 2 I
I
Lay. r4
3'
w.c.
Bath #2 Sher.
1"x4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
NTSPLUI„1BING
Install SGD thru buck into
block with 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
O
U 1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
Head
fixed door
sliding door
1 1/2"
bottom I rack �I
Sill
Sliding Door Detail
At Masonry Wall NTS
I" x L" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
gpical Flooring
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval la min
19, ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, AG.l and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CIIIS and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders Or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyin smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Grade
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM 1)(type 2) 30 lb relt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max
18101bs. uplift
Aluminum Drip -
Edge t Fascia
2" x 6" Sub -Fascia
Kallcan full o vent vinyyl soffit installed
using 1/8" dia shank x 15" long galv.
roofing nails with 3/8' die. head per
product approval - see chart sheet #1
5/8" thick light textured
stucco on typical concrete
block construction
3*5 bar vert. w/
30" overlap -
at each filled cell
1 I I, HU
12
4 1
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (l) 45
bar Cont. for bottom row over openings
1/2" drywall over I" x furring
strips at It." o.c. with R4.1 Pi-foll
insulation on typical 8" Block walls
All drywall to be installed per FBC R702.3.1
T and shall meet all pertaining ASTM codes.
ao Mortar to be Type "M" onlg proportioned per FBC R607.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(U #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
/ spacing at openings
4" concrete slab with fibermesh OR
VxV #10/10 WWM on L mil Visqueen over
/ clean compacted termite treated fill
ME
TYPICAL SECTION
III_.
14" x 14" Concrete footing
with (2) 45 bars cont. and 3*5
transverse bars at 48" o.c.
Total Under Roof= 22-15 sq. ft.
Total Cubic Ft = 13,1b0
2" VTR
JIL
I
Attach buck to block wall with I
1/4' dia. Elco cone screws with min. 1
1 1/4" penetration at 12" o.c. max i
and 4" max from each corner thru
Exterior face 2" x L" PT Buck 21' VTR
or wall /I JL
arles
( I I
1 2' 1
Master I Lev. 1
48 wood screws thru jamb int$b
at each hinge and 15' o.c. max an 2'
Detail at Door prior to door attachment Lay.
NTS 4" 1 2" VTR
W.C. JIL
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER. AND
SILL BLOCK PRIOR TO BUCK sher.k
INSTALLATION
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at jambs and 20" o.c. max
Exterior face at head and will per product approval
of wall -\ / \ Buck to be I" x V PT
Detail at Windows
1 1
3' 1
Kit. Sink I
I
Kitchen 2 I
I
Lay. r4
3'
w.c.
Bath #2 Sher.
1"x4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
NTSPLUI„1BING
Install SGD thru buck into
block with 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
O
U 1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
Head
fixed door
sliding door
1 1/2"
bottom I rack �I
Sill
Sliding Door Detail
At Masonry Wall NTS
I" x L" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
gpical Flooring
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval la min
Window Schedule
Mark
Size
Rough Open.
window Description
PRESSURE ZONE
I.
4'-5V'x 5'-3 %s"
54%s"x 63/4"
Single Hung
ZONE 4
2.
6'-2'/a'x 5'-3 %"
15" x 63 %;'
Single Hung
ZONE 4
3,
2'-2" x 3'-2%2"
27'/2"x 38%"
single Hung
ZONE 4
4.
3'-I" x 5'-3%"
38" x 63'/4"
Single Hung
ZONE 4
5.
4'-5319"x 4'-2%"
54k"x 54Ye"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturer s specs prior to construction
on sheet I
Door Schedule
Mark
Size
Rough Olpenirq
Door Descrl tlon
PRESSURE ZONE
A
9'-0" X T-O"
108" x 84"
Overhead Garage Door
'LONE 4
B
3'-0" X 6'-8"
41"%; x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
L'-O" X 6'-8"
74" x 81 %2' d ran"�t""
Sliding Glees Door
ZONE 9
D
2'-0" X 6'-8"
Solid Core - Wood
- 9-Panel -Bi-Fold
Finished 24" x 81 %'
E
1 2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x 4'-8" x 1 ;'
Solid Core Wood, Steel.
or Masonite Door
H
2'-8" X 6'-8"
Solid Core - Wood
- L-Panel
J
2'-4" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated
box on sheet 91
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
in permit info
AND SHALL
ON SHEET 41
3'
C.O. �\ To Septic
RISER
NTS
7'-0"
14'-O"
7'-0„
35'-O"
► is"0
10'-6"
Scale : 1/2" = I'-O"
STRUCTURAL NQTF_S:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN,
2.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,600 PSi AT 28 DAYS
10.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF (DL+LL) = 41 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
11.
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, t
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12-
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
5.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
1 3.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
BUILDING CONSTRUCTION
FOOTING: 3"
BEAMS: 1-1/2"
6-
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
1.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ATTENTION OF THE ARCHITECT.
16.
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
8.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
11.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
FO U
A
D/4T
f O
N
F
L- /
I N
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction_
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 95 bar vert. at 48"
O.C. max. Provide (1) filled cell on each side of openings upp to 5'-11" Wide.
Provide (2) filled cells on each side of openings from (o'-O" to 9'-11"
and Provide (3) filled cells on each side of Openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation Walls
Shall have filled cells at 24" o.c. unless Otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade �0, meeting ASTM A-1( and
A-35 specifications. ALL Anchors to be A-307 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/
30" overlap SEE TYPICAL
at each filled cell ECTIONS
4" concrete slab with Fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
r c —
dl —
-� 114"w x 14"d concrete monolithic
footing with (2) 95 bars Cont.
14"
TYPICAL FOOTING DETAIL
SCALE 1/2" = I'-U"
4" concrete slab with flbermesh OR
6"x6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
Q foundation plan
N
0° (2) #5 bars cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bare vert. tied
into lintels above Verify house slab
height in field
Top of footer
I(" below Finished floor
30"x30"AC concrete
column footing with (4)
45 bars each way
SCALE 1/2" = I'-rO"
SCALE: 114" = 1'-0"
FOOTING
SCHEDULE
Mark
size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) 45 BARS CONTINUOUS
F�
30"
x 30" x I6"D
COLUMN FOOTING WITH
(4) #5 BARS EACH WAY
F
8"W
x 8"p
THICKEN SLAB EDGE
WITH 1 45 BAR CONTINUOUS
FS
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB a 0'-0"
Thicken edge to 8"x8"
with concrete and 4" concrete slab with flbermesh OR
one #5 bar continuous 6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
GRADE
MW �I-111I
'f.4/ PORCH SLAB EDGE DETAIL
SCALE 1/2" = I'-O"
#5 bar vert. w/
30" overlap
at each filled cell
SEE TYPICAL
�ECTIONS
Adjust curb height
based on gar. floor 4" concrete slab with Fibermesh OR
slope. �\� TN Aill
L"xL" #10/10 WWM on 10 mil Visqueen over
#5 bar In curb clean compacted termite treated fill
O'-O" m P.F.
Grade
I I I i I�' \ with
x 1iconcrete monolithic
Footing with (2) 45 bars coot.
14"
GARAGE CURB DETAIL
SCALE 1/2" = 1`0"
2" x 6"
PT wood secured
with \
3/8"dia.
x 6" anchor bolt
at 18" o.c.
overhead door track secured to
wood
jamb per manufacturer's product
approval
Garage
Door Jamb
Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED
NTS
IN PERMIT
INFO BOX ON
SHEET #1. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL,
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
if soil area is disturbed after Initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
Filled Cell Masonry Column With One
95 From Footing To Tie Beam
Conic. Fill To Be 3000 PSI
See Floor Plan For Location
O
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
u5 From Footing To Beam Each.
Conic. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
0
0
r
10
I �
L-_ R
l:IA
12" x 12" concrete column block fill
with concrete and (2) 41 bars ver , tied
nto lintels above
°
---L
I I L T
I Filled cell under
FI I girder above
FI 24" I Rear Porch Slab to LLI
be poured separately I
r J from House Slab. O
I �r
N
Thicken footing to t
24% x 14"d x 24"L I I
under filled cell I a
under girde74"
00 O O 0C
I--- — — —-
- Rear Patio/Slab to FI
be flush with bottom of
sliding door recess.
Slope I" F_
i F-
I
I FI I
I I
I�
° I
I I
slab with Fibermesh OR
6"x6" 410/10 WWM on 6 mil Visqueen over I @
clean compacted termite treated fill
I FI I
I I
i
0 V '
I �-
I ° i �-
I
01 I�
FI
I I
0 I�
— -- 0 — oO� I
#I
5'(0 Steel a detail gardon11ths sheet
� I I Q ae't l
L _ - -
i
I I I I
4" concrete slab with Fibermesh OR
OxV #10/10 WWM on 6 mil Visqueen over I I
O clean compacted termite treated fill ( I
I N I I FI I
� W — _Lk
—
o'— l00 00l I
F5lu
I I
I F5 Recess for I O
O L————
Gara�ce Door --- J O a F4 I I
00 00 E7 101711 7
I FI
I I
I I
�I I
I I
O �
0 \ FI —�
°`- — — — ——
n
9'-0" 3'-6" 2'-8" 2'-8° 2'_2„ 9'-61,
5'-10" 5'-4" 13'-10"
N_tl
1"9-01
iy
N
0
0
0
a
r
a
— ...
... is
♦......��..Ill-
........Q
-Q---Q-------
e --
,�:�:�Q
.
.. •
Ke
Area
Ede
Field
Fastener
Preaxure
Zone I
b"
b"
Bid ring shank
45 psf
Zone 2
4"
b"
8d ring shank
Ill psf
Zone 3
4"
�}"
Sd ring shank
84 psf
48 wood screw
112.5 psf
Verify with Plan
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel.
Provide Cast -Crete
8U8-OB/OT precast `----- -- -
lintel set in mortar-_____
Min. 8" Bearing ---
12"x 12"
lumn Block
Rebar
inn. vveriap
Column tc Lintel Attachment
NTS
Provide #S bar set inpre-castF--' o O F FD L A N Scale : 1/2" = I'-C"
lintel into beam where length of
the opening calla for it. — ® 1'-0"
l h t d t h h e s t
divide PT Buck
.ached per jamb
ails into filled c,
4" Pre -cast
Sill
J
ver angs at un ess of erwise no e on 15 s
— Roof pitch at 4:12 unless otherwise noted on this sheet
— Truss shop drawings to be provided bg manufacturer
Ang changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
Architect to review Truss Shop Drawings Prior
Poured Filled Cell to construction for lagout and uplift verification
Contractor to provide for Form Board Surveg and to provide
Form Board Surveg to Truss Compang prior to truss constructio
Provide tt5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
rooter steel.
CBS WALL Scale: I/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with Ill x 1.5 nails at 4" o.c.
Install Simpson MGT mto wall using
5/8" din. threaded rod set min. 12"
\ nto wet beam and (22) IOd nails into truss
s
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tyype 2 felt paper using 8d nails. Substrate
to be 19/32' COX Plywood Waded at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11461.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
#5 bars
wl.�. .f CLEAR
Lintel
Length
Bar
Length
Clear
Span
ii
A
Bars
u u
B
Bars
'-6"
i
2'-10"
2'-8"
2,V 3
none
i i I i f
3'-6"
3'-4"
2'-2"
2 #3
none
8F8-05/IT BPS-IB/IT BPS -Ill
Additonal
4'-0"
3'-10"
2'-8"
2 #3
none
„
#5 bars
CLEAR_
4'-6"
4'-4"
3'-2"
2.0 3
none
,�-;One Row of "H" -
5'-4"
5'-2"
4'-0"
2,#3
none
Block Above
4'-6"
2,44
none
F y Precast Lintel
6'-6"
6'-4"
5'-4"
2 u4
none
.:
i f Additional Qf
#5 bars L____y
none
BFIL-IB/IT BFIL-IB/2T
7'-10"
7'-0"
2,#5
none
NOTES:
ALL reinforcing steel is grade 60.
I. min. coverage of steel-1.5"
2. min. bearing required a ea. end=8"
3. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or D
Unit Width
Size
_
SpecrficaGon
Rows of
"H" Block
Above
Steelm
size
steel
Size
Max.
Gravity
PLF)
Max.
Uplift
(PLF)
Max
Lateral
(PLF)
L22
T-2"
3'-V
8F8-OB/IT
1
tt5
3069
1569
1024
L31
2. -6.
2'-8"
4'-0"
ere-OB/IT
I
#5
256I
130
143
L45
4'-S"
5'-10"
8F8-OB/IT
1
#5
1105
909
339
LSO
5'-O"
ii
SFe-OB/IT
I
#5
1238
ass
121
L60
4'-8.
T-V
8F8-05/IT
1
#5
1011
-12,1
534
L80
8'-0"
9'-4"
8F8-IB/2T
1
#5
2
#5
152
591
512
L90
9'-0"
10'-L"
8F8-IB/2T
I
#5
2
#5
443
530
401
L90B
9'-O"
10'-L"
81111
ONE
1
#5
2
#5
1533
1183
401
LIOO
10'-O"
ll'-4"
8F8-IB/2T
I
#5
2
#5
582
494
452
LIOOB
10'-O"
Ii'-4"
BFIL-IB/2T
ONE
I
#5
2
#5
136f.
1028
452
L120
12'-O"
13'-4"
8F8-IB/2T
1
#5
2
#5
411
428
324
L1205
12'-0"
13'-4"
arlil B/2T
ONE
I
#5
2
tt5
Ill
110
324
LI40
14'-0"
IS'-4"
BFIL-IB/2T
ONE
1
tt5
2
#5
1250
409
259
LILO
Jill
IT-4"
8F8-IB/2T
1
#5
2
#5 I
300
192
194
LILOB
I4'-0"
IT-4"
8FI4-IB/2T
ONE
I I
#5
_T7
#5
950
Soo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORRMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 1,411 LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails -
( 24" o.c.) suppporting Max.
18101bs. Uplift
Aluminum Drip
Edge t Fascia
12.
2" x 6" Clff
Kai full o vent vingl soffit installed
using 1/8" the shank x IS" long gale.
roofing nails with 3/8" ilia. heed per
roduct a roval — see chart sheet #I
12
4
Poured Concrete or
concrete block wall
e Anchors Per
Lurers Specs
1/4" Max.
Aluminum Panel
Sizes per manufacturer
See Tuoicai Stud Detail
1/8" x 3/32' Wing Nut w/
a appropriate washer and spacing
`u per manufacturer's Details
i 094"
' e 9
1 � �
i
I qm
a
i
I
I
' I
1
1 I IBTS'
I
Stud Detail
Poured Concrete or I NTS
concrete block wall \ I Stud w/ Die Cast Zinc
\S ri Nickel Plated Wing Nut
Concrete Anchors Per �.
Manufacturers Specs
Mush Mounted Shutter Detail
nts
Aluminum Dnp
Edge t Fascia
Flash and Counter
flash
Nail ledger s
gable end truss
with (2) IOd ds
at each web
Brace Gable end
with 2" x 4" SYR #2
Slit back nailed to bottom
of top chords using (2) 10d
nails at each truss
PRE-ENGINEERED WOOD TRUSSE
® 24"o.c. TYPICAL
( shop drawings by manufacturer )
137
" \R-30 blown fiberglass
1/2^ thic stucco on 3/8" hi —rib lath in bottom chord of trusses a
attached to horizontal and vertical wood
i/2" drywall with smooth Finish
framing with nails or staples to provide
no less than 1-3/4" penetration into c
horizontal wood framing and 3/4" penetration Two rows of beam block filled with concrete 0 o
into vertical wood Framing members and (U #5 bar cont in each row Substitute 1 0
precast lintel filled with concrete and (U #5 r- rn
bar cont. for bottom row over openings o
1/2" drywall over I" x furrin
e)
N
X
r
OU rn
N113
U e
u-i
� Q LL
a
_-Z ra n
� R U
N o0
E_ L
N 2 C�V
L_
� V
p pp
5/8" thick light textured
strips at I6" o.c. with R4.1 f1-loll U Ln
12" x 12" concrete column
stucco on typical concrete
block construction
insulation on t pical 8" Block walls
il
block filled with concrete
All drywall to be installed per FBC R102.3.1 v
To
and (2) #1 bars vent. tied
Varies -see plan
T and shall meet all pertaining ASTM codes.
into lintels above
#5 bar vert. w/
Mortar to be Type "M" only proportioned per FBC R601.1
Mortar joints shall coinply with FBC R601.2.1.
thicken edge to 8"x8"7
30"overlapand
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
with concrete and
at each filled cell
one #5 bar continuous
Fill cell with concrete and
BEYOND
Rear Patio/Slab to
(U 45 bar vert. (typical).
be flush with bottom of
Max. spacing shall not exceed
sliding door recess. Wood
48" unless otherwise noted
see foundation plan notes for
To of Tooter
I6"pbelow finished floor
Base
spacing at openings
Step per foundation plan
4" concrete slab with fibermesh OR
Ox(" 410/10 WWM on 6 mil Visqueen over
`e
Slope per foundation plan 'r
clean compacted termite treated fill
-IIIIIIII-III
IIII-IIII IIII IIII IIII-IIII IIII IIII1
' =IIII=IIII-IIII
=illl
�-IIII�1111111i „IIII-IIIIIIillli ����� ���I-
ii�l
iIIIl11jlll
�iii
1�=�� �iii=l T6plcal Section
at Front Forch
3
Scale : 1/2" = 1'-0"
d
N
Simpson HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift HETA 20
Q
L31 BI
LLO
777
BI
Strap
truss to wall
using Simpson MGT with
5/8'
dia,
threaded
rod with min 12" embedment
into beam
either wet
set or in epoxy with
(22)
IOd
nails into
truss. Add blocking to
truss
leg
per detail
on this sheet
II ryl� II II II II
0)
f/AUKTED A
WOMAN
NO
MAM
ill
B1 L45
L45
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
BI 4FSLOPE 26 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
ft
ype e LATIJUTI,ligment insEalled wlEn min. si a aps an an
laps Fastened with corr sion resistant tin caps and with 1.25' ring shank nails BI
Spaced 6" o.c. at all I s and two staooered rows 12" o.c. in Field. Attach
L31
BI
L90B
1 tc x 59" I
Attic Access 111�. BI L31
�\_�
2\0 I
ry
Cc�
HETA 20
Simpson HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
RAW
SLOPE
Q
t-
4u
x
O
r
rn
ty
to
Oil
c
(a
+J0
O
r2
�
2
N N
V
� �
N
o0
E Z00
N
as
2
O
H
Ild
PANEL
"A"
Poles
BR
Load
Wire
Description
circa
circ#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
a10
3.5 kw
30
2
3
5
4
9
2
2
30
4.5 kw
#10
40 gal. water HTR
Range
tt6
12.0 kw
50
l
9
8
10
Dr er
#10Fkw
1
20
1.8 kw
#12
Pump
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
412
Microwave
Is
IL
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
n
18
Recepts
#12
-
20
1
1
20
1.5 kw
912
Kitchen S.A.C.
19
20
Recepts
#12
-
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
412
20
I
1
15
#14
General Lighting
29
30
Recepts
#12
-
20
1
1
15
#14
General Lighting
31
32
Recepts
#12
-
20
1
-
1
is
#14
General Lighting
33
34
Exterior GFCI
#12
-
20
1
I
15
#14
General Lighting
35
34
Bathroom GFI
#12
20
1
1
20
#12
Smoke Detectors
3l
38
General Lighting
#14
15
1
-
1
20
#12
Bathroom GFI
39
40
General Lighting
#14
15
I
spare
41
42
s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3. watts sq. ft.)
Small, Appliance. Clrcult(s)........ _ _ .. ....
.
Range _ ............................... „ . . ................
Refrigerator. .....................................
Microwave
Dish Washer
.................................................................
.Clothes. Washer .............. . . . .. . . . ......... I . ...... , . , . , . ,
Clothes..Drger. ................. . ......... ...............
Water Heater
.................................................................
Water Pump ...................................................
Garage. Door Opener..
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
1,200
1,200
I
5.000
5,000
1
4,500
4,500
1
1,800
1,800
1
810
810
Total Watts
31,415
First 10000 Watts 5100%
1
10,000
10,000
Remainder 21,415 e40%
1
0
10,944
Electric Heat or A/C 10,000 965%
1
10,000
10,000
Calculated Load
Watts
30,966
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical 5 mbol Legend_
$
Single Pole Switch
®
1 Recessed Can Light
Ss
Double Pole Switch
®
Egeball Recessed
Pe
Push Button Switch
�AA
Exhaust Fan
Duplex Outlet
Y
Ceiling Mounted Light
Special Receptacle
o-
Wall Mounted Light
Waterproof, ground fault interrupter
3aK
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
cn
Carbon Monoxide Detector
Flood Light
®
Thermostat
m
Electrical Panel
®
Central Vac
rc":�
Electrical Meter
5Q
Smoke Detector
M
v�\v
Ceiling ran
®
Television Jack
Telephone Jack
ACDiscA/C
Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
El
Intercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = Balanced Air
Electric Notes:
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verrfg location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
S. ALL bath and kitchen receptacles to be GFI protected.
L. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMlL02
10. A/C Refri Brant lines that are run thru slabs must be
sleeved in PVC
II. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be full operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liabilitg and property damage for the
duration of the work.
1is. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone companu.
#2/0 Aluminum feed
1 '/s' Conduit -�
2" PVC (
2"
SEE MANUAL
"J" and Energy
Calculation
for Unit info
#L copper wire
cont. rebar in slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
19. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters' Y E C H � �\ j C � L
labels where applicable. `��l Iv
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22.
Furnish and install
all fixtures as
called for on the plans
or as selected by
others.
23.
All raceways and
pipes placed in
or through any concrete
slab shall be spaced a minimum of
three diameters of the
largest conduit or
pipe from any other
service.
24.
All exposed wire
below 9'-1" shall
be installed in metal EMT
conduit.
25.
Dryer Vents to
be installed per
FBC RM1502
Vent thru
L=a'�CUT
O= THERMOSTAT LOCATION SCALE: 1/,4" = 1' - 0'
Braden t
Braden AIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (1-12) 287-8258
Fax
: (112) 281-8283
E-mail:
bradenaiaOcomcast.net
Stuart. FL
34996 #AACOO0032
Exhaust Duct
Thru Soffrt,
4" Exhaust
Duct Thru
Wall
WP GFC
EL_E
SCALE:
Wgnne Building Corp.
THE ROYALS
Spanish Lakes
St. Lucie County Florida
MODEL
GARAGE
LEFT
Post Light with
Photo cell\
Date Drawn
5-9-I-1
Drawn by:
C.C.U.
Checked by:
D.R.B_
iu
u-
Revisions :
Exhaust Duct
Thru Soffit
Wire For
Front most
Light
er Post Light on
corner
Sheet
OF 5
Comm #
2-100