Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: 1j 2 Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ftz b. Frame - Wood, Adjacent R=11.0 240.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (1720.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1720.00 ftz 6. Conditioned floor area above grade (ftz) 1720 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(155.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 115.42 ftz SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1720.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15.*Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 54.94 PASS Total Baseline Loads: 56.22 I hereby certify that the plans and specifications covered by Review of the plans and 4T14E STrj this calculation are in compliance with the Florida Energy w specifications covered by this 1�0 _ 0�, Code. calculation indicates compliance �O with the Florida Energy Code. rrn,:,,, �., •.,;. ; ;,.�",ti PREPA DATE: Before construction is completed this building will be inspected forj` compliance with Section 553.908 ;d * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. 1 9� COD with the Florida Energy Code. OWNER/AGkA BUILDING OFFICIAL: WME DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope, akage test report in accordance with R402.4.1.2. ", ,Va. •43i' l�f � ��??'� 4 1b 10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft2 ---- 0 1 0 10/24/2017 9:20 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N=>SE Exterior Concrete Block - Ext InsiflEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext Insf3EDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext InsiHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext InQEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 7 NE=>S Exterior Concrete Block - Ext InQEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 _ 9 SE=>W Exterior Concrete Block - Ext InMEDR00M 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block - Ext In!flEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 12 E=>SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Space Cavity Width It Ornt To MIMI TVPe Height Sheathing Framing Solar Below 13 S=>NW Exterior Concrete Block - Ext InsLllAUNDRY 4.1 6 0 8 14 N=>SE Exterior Concrete Block - Ext InsGiREAT/DINT 4.1 28 0 8 15 W=>NE Exterior Concrete Block - Ext InsGiREAT/DINT 4.1 20 0 8 16 N=>SE Exterior Concrete Block - Ext InJ3ffDROOM 3 4.1 13 0 8 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 0 48.0 ft2 0 224.0 ft2 0 160.0 ft2 0 104.0 ft2 240.0 ft2 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0.23 0.5 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 2 S=>NW 4 Metal Low-E Single Yes 3 E=>SW 8 Metal Low-E Single Yes 4 N=>SE 14 Metal Low-E Single Yes 5 W=>NE 15 Metal Low-E Single Yes 6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 0.54 0.25 0.54 0.25 0.54 0.25 0.55 0.25 0.54 0.25 32.4 ft2 1 ft 0 in 6.9 ft2 1 ft 0 in 23.2 ft2 1 ft 0 in 36.8 ft2 1 ft 0 in 40.0 ft2 10 ft 0 in 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None Exterior 5 None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM. # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Venting Jan Feb Feb Mar €X� Mar �X� Apr Apr I i MaMnly rl Jun. ri Jul Aug rl f l Sep Oct Oct Nov X� Nov Dec Dec Jun [ Jul Aug [ Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1