-}.f- wrightsoft° Project Summary Entire House QUICK CALCS, INC. 317 St. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 .Fax Email: For: THE ROYALE WYNNE DEV., FT. PIERCE, FL Notes: Job: Date: By: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90. OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/Ib Heating Summary Sensible. Cooling Equipment -Load Sizing Structure 19898 Btuh Structure 18607 Btuh Ducts 6092 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh. Piping 0 Btuh Equipment load 25990 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 26420 Btuh , Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2182 Btuh Ducts 2616 Btuh -Central vent (0 cfm) 0 Btuh Heatingg Coolingg. VA (none) Area (ft2) 1720 Equipment latent load 4697 Stuh V01ume (ft3) 14231 14231 Air changes/hour 0.38 0.20 Equipment total load 31117 Btuh Equiv. AVF (cfm) 90 47 Req. total capacity at 0.70 SHR 3.1 ton Heating. Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360. Btuh Heating output 34600 Btuh @ 47'F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling. 34800, Btuh Actual airflow 1160 . Actual airflow 1160. cfm. _cfm Airflow factor 0.045 cfm/Btuh 'Airflow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat . Load sensible heat ratio 0.86 Capacity balance point = 35 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightso$- 2017-Apr-10 17:29:34 Right -Suite® Universal 201717.0.14 RSU08101 Page 1 ...1Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoft• Right-J® Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 180.9 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 343.0 ft 5 Room area 1719.5 ftz 343.0 ft' Ty Construction number U-value (Btuhlft2L-•F) Or HTM (Btuhlft') Area (ft2) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-gocs 1A-c1om 0.143 1.270 n , n' -4.00 35.56. , 2:55 34.77 577 16 524 0 2096. 565 1333 553 72 0 72 0. 288 :0 ' 183 0 r_ G '4A5-2om A.77.0 : n 21:56 . 19.31. 38 0 815 730 0 0 io 0 11 W 13AAocs . 13A-4ocs 0.143 0.143 ne e 4.90 4 00 2.55 2.55 34 112 34 67 136 269 86 17.1 0 0 0. 0 0 0 0 0 1A clom :.: 11D0 `. 1;270 0:390 a .e, 35 56 10.92 87 29 . , 11'.31 . 24 . _ 21 3 ;..:21', 848 229 2082 ... - 238 0 .;_'_ 0i :. , 0 .0.; ; 0 0 w 13AAocs 13A4ocs :-1A,c1om:,- 0.143 0;143 1:270 se s ; . s - 4.00 4:OQ 35i56 Z55 2:55 34.77 23 456 7 23 949 14 91 1798 247 58 1143 241 0 ': 232 .• 0:.: 0 232: :0''. 0 929 ,- 0, 0 597: -_0. V�! �G 13A-4ocs IA-clom 0.143 1.270 w w 4.00 35.56 2.55 55.25 290 33 217 4 867 1162 551 1806 112 33 79 2 318 1162 202 1806 �-G 4A5-2om 112C-0sw: _. ", 16A-30md 0.770 0091 0.032 w .: - 21.56 255. 0.90 45.63 1i28::. 2.32 41 224 1720 4 224. 1720 880 .; 571 .1541 1862 ;;. 287 3989 0 0:.., 343 0 .. 0. 343 0 307 0 796 P C tpl ` : 0 989 . = :: ` 27:69 0:00 ` 1726 . ' 181, °5010. !:0..-343 52 X. t.. 6 c)AED excursion 465 668 Envelope loss/gain 17124 15595 4444 4245 12 a). Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 1 230 2000 0 0 0 Subtotal (lines 6 to 13) 1 19898 18607 5218 4463 Less e:demal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Ductloads 31% 49% 0 0 19898 6092 0 0 18607 . 9204 31% 49% 0 0 5218 1598 0 0 4463 2208 Total room load Air required (cfm) 25990 1160 27810 1160 6815 304 6671 278 of Manual J.8th Ed. �A wcightsoft- Right -Suite® Universal 2017 17.0.14 RSUDS101 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup -Calc = MJ8 Front Door faces: N 2017-Apr-10 17:29:34 Page 1 wrightsoft RighWO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 611 SI. LUUIt LN., 1' 1. Yltr<Ut, M 14`140 rnone: /2-4au-oftpu rax ifcgoo-oroo tmall: 6IUI VI�VfU.Va�\VL.VVIVI 1 Room name WIC M. BATH 2 F�cposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool - 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 Ty . Construction . U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs. 0143 n 4:00 2;55 ,. 0 0 01, 0 0 0 0 0 1Ac1om . 1.270 n . 35.516 34.77 .0 .0 0 0 -0 ` 0. 0 .. '0 4A5 tom, 0.770 ;. n ', 21.56 19.31, 0 0 0. 0 0 0 0 .0 W 13A4ocs . 0.148 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 3AAocs; 0143 e 4 00. 2 55 0 0 0 0 0. '0' 0 , 0 �-,,l 1Ao1om • 1 270 a 35'56' 87'29 0 0 0. 0 0. 0. 0 0 ...... 11D0 .::•` 0390 ' .e;'• 10:92; _ 1131: 0 ; 0 0:. = 0 .:°. 0 . ,-io . `;0 ,. •i'0. W 13AAocs 0.143 se 4.00 Z55 0 0 0 0 0 0 0 0 13AAocs . U 143 s 4 00: 2,'55 0 0 : " 0 0 64 57 : =228 145 ;1`270 s. -35'56' ,. 34:77 0 0 0 ; 0 7 `. 7 r ,247 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 1" G 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 2C-0sw"..; :0 091, -;:; 255: ;1,28 0 >,- . 0 .:. .: 0 ;0 :: i<.0 : z,0 C 16A-30md 0.032 - 0.90 2'32 63 63 56 146 66 56 50 130 .??lktpl :=..` : •0.989 , r 27:69 . 0:00 .- 63 ... : 0 .. ' 0 . p ' .:. 56 i`: :6 4. .. 3 6 c)AED excursion -10 139 Envelope loss/gain 56 ` 136 747 477 12 a) Infiltration . 0 0 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 136 866 511 Less extemal load 0 0 0 0 Less:tiansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 15 Ductloads 31% 490/a 17 67 31% 49% 265 253 Total room load 74 203 1131 764 Air required (cfm) 3 8 50 32 all reauirements of Manual .J A wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 ...\Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Cale = MA Front Door faces: N 2017-Apr-10 17:29:34 Page 2 - wrightsoft° Right-JO Worksheet Entire House. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 -Fax 772-4066796 Email: QUICKCALCS@j\OL.COM, Job: Date: By: 1 Room name KITCHEN BATH . 2 Bcposed wall 0 ft 5.0 ft 3 Room height 8.0 ft , heat/cool 8.0 ft heat/cool. 4 5 Room dimensions Room area 1.0 x 172.0 ft 172.0 ft2 9.0 x 6.0 ft 45.0 ftz Ty Construction number U-value (BtuWft' `F) Or HTM (Btuh/ft2) Area (ft') or. perimeter (ft) Load (Btuh) Area (ftq or perimeter (ft) Load (EBA Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4ocs. ' 0.143 q .. 4.00 2.55 0 0 0 0 40 40 160 102 1Ac16m' 4A5 2am.. 1:270 0.770 n' . ,, n 35:56 21- ' .. 34.77 19.31 0 .. 0 0 0 0 0 .0 0 ' 0 0 0. 0 0 0 0 0 11 1N 13A-4ocs . 13AAocs - 0.143 0;143 ne a 4.00 4.00 2.55 2:55 0 0 0 0 0 0' 0 0 0. 0.' 0 0 0 0 0 0 1Ac1om 1-270 a 3556 8729 0• 0 0 0 0 0, 0 0 11D0. 0.390 .:'.6,:, .10 92 . 11:31 0 ...0 ' . • . 0 . ., ...0 -0 ... 0 • -- 0 , : 0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 .0 0 0 13A,4ocs:. 0 1:270 s::' .. 35:56 3477 0 < . 0 Q 0 V 13A•4ocs 0.143 w 4.00 2.55 0 0 6 0 0 0. 0 0 IA-clom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 IA/---� �---G 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 ;P 12C Osw>;::. .... A.091 255: ,. . " :1;2864 .::.. 64 :. -163 ;,. -.82 ..: ;,0 , . .0 :: C 16A-30md 0.032 - 0.90. 2.32 172 _ 172 154 399 45 45 40 104 27.69 , . .00 : .. 172''': J0 ..;:. "0 ' '_ 0 : -".i5 : . M 6 c)AED e)xursion -176 -16 Envelope loss/gain 317 305 339 190 12 a) Infiltration 0 0 74 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 subtotal pines 6 to.13) 317 2305 413 211 Less exfemal load 0 0 .0 0 ' Less transfer 0 0 0 : 0 Redistribution 0 0 0 0 14 • Subtotal 317 23051 413 211 15 Duct loads 31% 49% 97 1140 31% 49% 127 104 Total room load. 414 . 3446 540 315 Air required (cfm)T7 18 110 24 13 _ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . A -Fk wrightsoft" Right -Suite® Universal 2017 17.0.14 RSUD8101 2017-Apr 101Page3 \Quick Calcs\Documents\WYNNE-ROYALS-REVISED.rup Calc = MJ8 Front Door faces: N 0 - - wrightsoft' Right- 0 Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL,COM 1 Room name BEDROOM 2 ENTRY 2 -=ed'wall 42.6 ft 6.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 204.0 ft 204.0 ft2 1.0 x 97.5 ft 97.5 ft2 Ty Construction U-value. Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftl�-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 1Ac1om ' : 4A5.2om 0.143 1:270 . 0.770 n n' : n 4.00: 35:56 21.56 2.55 34.77 19.31 112 0' 0 112 0 0 448 0 0. 285. 0 0 0 0 0 0 0 0 0 0 0: 0 '0 0 11 W 13A-4ocs . 13AAocs 1Ac1om 11D0. .0.143 0.143 1:270 U.390 ne e . e , e; 4.00 4.00 35;56. , 10 92 2.55 2 55 87:29 , 11:31 23 ,, 72 24 60 23 .48 2 0 91 193 ;848 . 0 58 123 2082 • 0 11 40 . ,.__ 0', 21 11 19 0 21 45 76 - 0 229 29 48 0 :238' W L-G 13A-4ocs 1Acs. 0.143 1.2 0 se t s 4.00 40U 35 56' 2.55 2.55 , 34.77, 23 112 . ,0 23 112 0 91 " 448' : 0 58 '` 285:'`, 0 0 0 o .. 0 < . .0 0 0 . 0 ,b, 13AAocs 1A-c1om 0.143 1.270 0.770 w w w 4.00 35.56 21.56 2.55 55.25 45.63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --G t 14A5.2om C F . 16A-30md 22A t I '.. P 0.091 0.032 : 0:989 -:... - _ : 0.96 27 69 2.39 U;00 . 0 204 204 ... .. 0 204 43 . •0 183 .. 1179 .: - "ID; 473 : 0 :• :104 98 , 98 .. 104 98 ." :6 265.. 87 175 .... ,133; 226 . .0 6 c) AED excursion -90 -50 Envelope loss/gain 3481 3273 878 625 12 a). Infiltration b) Room.ventilation 634 0 179 0 95 0 27 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1 0 0 Subtotal (lines 6 to 13) 4115 ' 3452 974 651 Less extemal.load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 49% 1260 .1708 31% 490/a 298 322 Total room load M76 5159 1272 974 Air required. (cfm) 240 215 ' 57 41 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -- wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-1017:29:34 ;Wj� ...\Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Page 4 - wrightsoftRight=J®Worksheet Job: Entire House Date` By:. QUICK CALCS, INC.. 317 ST"LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM A Room name LAUNDRY ..GREAT/D)NING 2 Exposed wall 6.0 ft 48.0 ft 3 Room height 8.0 ft . heat/cool 8.9 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 528.0 ft 5 Room area 42.0 ft2 528.0 ft2 Ty Construction U-value Or HTM Area (ft2) - Load . Area (ft2) Load number (Btuh/ftz'F) (Btuhlft1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S, Heat Cool 6 13A-49cs 0143 . n ;4:00 2.55 0 0 0 0 249 211 846 538 1Ac1grn 1270 n, 35:56 '. 34.77 0 0 0 .0 0' 0 0 0 _4A5-tom O.T/0 : n 21 56 19.31 0 ": 0 0 0 38 , . 0 815 730 W 13A.Aocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A-4ocs 0143 a 4:00 Z65 0 -0 0 0 0 0 0 .• 0 1Ao1om - ' 9 270 a .: 35.56 87.29 .0 0 : 0 " . 0 .. 0 0 -0 -.0 0 390 . ,e 10.92 . 11:31 O. . • ...' 0 " 0 :, 0 .: 0 0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A 4acs ;; l)143 s ^; 4 00; 2:55 98 48 z 192 ' : 122 U " 0 0 0 ;1Ac1om, ' :,1.270 s .= . 35.56 . 34.77 . 0 0 0 : 0 '. 0 ` 0 ' 0 :0 V�J 13AAocs 0.143 w 4.00 2.55 0 6 0 0 178 137 549 349 1A-clom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 II----1C' 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 41 2 880 1862 0.�091 ".. '=:: :2;55. `.:•:1:28 ;`,:' S6 .,:56 143., ;.. .72;'.:. '473 0. C 16A30md 0.032 - 0.90 2.32 42 42 38 97 528 526 1225 F .. .�.fpl " : 0.989 :, 2769' "000 :: > 42 ".. :' 6 : -:166 :. .,0 ,:. 528 "` 48 " ' ' 4329 - • ='0 A. 4. 6 c)AFD excursion -22 305 Envelope loss/gain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 628 294 5697 5232 Less ek-emal load 0 0 0 0 Less transfer 0. 0 0 0 Redistribution 0 0 0 0 14 Subtotal 628 294 5687 5232 15 Duct loads 31% 49% 192 146 31% 49% 1741 2568 Taal 'room load 820 440 7428 7821 Air required (cfm) 37 18 332 326 Calculations approved byACCA to meet all requirements of. Manual J 8th Ed.. �A wr. ightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:page ge 5 5 .\Quick Calcs%Documents\WYNNE-ROYALE-REVISED.rup Cale = MA 'Front Door faces: N - - wrightsoft° RighWO Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM 3 2 F)posed wall 13.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 13.0 x 13.0 ft 5 Room area 169.0 ftz Ty Construction U-value. Or HTM Area (ft.) . Load Area Load number (Btuh/ft2L-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0A43 n 4.00 2;55 `104 88 353. 224. 1Ao1om 1.270 - n 35:56 .34.77 16 0 565 '553 4A5 tom .:- 0.770 :: In21:56 . 19.31 : 0 0 0 0 W 13X4ocs 0.143 ne 4.00 2.55 0 0 60 11 _ 13A-00cs 0.143 e 4.00. 2 55 , 0 0 0 0 1A-c10m :" 1.270 e , 35.56: 8729 0 0 ' 0 • 0 11D0 0.390..e'.': 10:92'. 1131 :0,0 W.. 13A4ocs 0.143 se 4.00 2.55 .0 0 0 0 93A flocs: •. 0.143 s r 4 00 255 0 0 0 0 1Aro1om: ; 9i270 ,,. s ' 354 34s77 , p p 13A-0ocs 0.143 w 4.00 Z55 0 0 0 0 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 P ' C 0sw :%' 0:091 ` = °; 2i55' 128 . : "' .0 :°. : 0 : :" 0 .. .:.c 0 C 16A30md 0.032 - 0.90 .. . 2.32 169 169 151 392 F. -22A•tpl "•;0:989 , _."c 17.49.. 0:00 .169 1'3 %6 4. ,. 6 c)AED excursion. -103 Envelope loss/gain 1430 1066 12 a) Infiltration 193 56 b) 'Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal Qines 6 to 13) 1623 1351 -Less wdemal load 0 0 Less,transfer 0 0 Redistribution 0 0 14 Subtotal 1623 1351 15 Duct loads 31%' 49"/6 497 668 Total room load 2120 2019 Air required (cfm) 95 84I . Calculations approved byACCA to meet all requirements of Manual J.8th Ed. -- wrightsoft• , 2017-Apr-10 17:29:34 .A Right Suite® Universal 2017 17.0.14 RS1108101 Page 6 .AQuick CalesCDocuments%WYNNE-ROYALE-REVISED.rup 'Calc = MA Front Door faces: N 1- wrigfltsoft° Duct System Summary Job: : Entire House By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM • For: THE ROYALE WYNNE DEV., FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply /: return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating. 0.50. in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250: in H2O 0.286 in/100ft 11'60 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm 175 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 Ox,O VIFx 27.3 115.0. st1 BEDROOM h 3408 152 139 -0.286 7.0 Ox 0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 . 0.343 7.0 Ox0 VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 6.371 6.6 Ox0 VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0. Ox 0 VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 OxO VIFx 31:7 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 Ox0 VIFx 18.1 115.0 st1 LAUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 Wlc c 203 3 8 0.309 4.0 Ox 0 VIFx 26.6 135.0 st2 Supply Trunk Detail Table Trunk. Htg Clg Design Veloc Diam H_ x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 630 613 0.286 814 12:0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 . 1119 0.286 802 16.0 1 0 x 0 VinlFlx �J{} wri htsoft° 2017-Apr-10 17:29:35 A= " I 9 Right -Suite® Universal 2017 17.0.14 RSU08101 . Page 1 Arm ..\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) . Diam (in) H x W (in) Stud/Joist Opening (in). Duct . Matl Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 VIFx J �J:�} wri htsofta 2017-Apr-10 17:29:35 �. ' 1" 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N