Loading...
HomeMy WebLinkAboutNOA # 16-0112.07MIAMI-DADE COUNTY M1� PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Entegra Roof Tile, LLC 1289 NE 9th Ave Okeechobee, FL. 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bermuda Concrete Flat Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1120.06 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No. 16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Entegra Flat Tile Length = 16" TAS 112 Flat profile, interlocking, high pressure extruded Width = 10" Type 3a concrete roof tile equipped with two nail holes. Class III For mechanical, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at w = varies hips, rakes, ridges and valley terminations. varying thickness Manufactured for each file profile. 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) The Center for Applied Engineering, 94-084 Static Uplift Testing May 1994 Inc. PA 101 (Mortar Set) The Center for Applied Engineering, 94-060A Static Uplift Testing March, 1994 Inc. PA 101 (Adhesive Set) The Center for Applied Engineering, 25-7094-2 Static Uplift Testing PA 102 Oct. 1994 Inc. (4" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, 25-7094-8 Static Uplift Testing PA 102 Oct. 1994 Inc. (4" Headlap, Nails, Battens) The Center for Applied Engineering, 25-7094-5 Static Uplift Testing PA 102 Oct. 1994 hie. (4" Headlap, Nails, Direct Deck, Recover/Reroof) The Center for Applied Engineering, 25-7183-6 Static Uplift Testing PA 102 Feb. 1995 Inc. (2 Quik-Drive Screws, Direct Deck) NOA No. 16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 2 of 6 2.2 EVIDENCE SUBMITTED ' Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, 25-7183-5 Static Uplift Testing Feb. 1995 Inc. PA 102 (2 Quik-Drive Screws, Battens) The Center for Applied Engineering, 25-7214-1 Static Uplift Testing March, 1995 Inc. PA 102 (1 Quik-Drive Screw, Direct Deck) The Center for Applied Engineering, 25-7214-5 Static Uplift Testing March, 1995 Inc. PA 102 (1 Quik-Drive Screw, Battens) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix H PA 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 PA 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied Engineering, Project No. 307025 Wind Driven Rain Oct. 1994 Inc. Test #MDC-77 PA 100 Atlanta Testing & Engineering, Inc. R1.894 Physical Properties Aug. 1994 R2.894 PA 112 R3.894 Professional Service Industries, Inc. 395-40011-1 Physical Properties Feb 2004 PA 112 Celotex Corporation Testing Service 520109-1 Static Uplift Testing Dec. 1998 520111-4 PA 101 Celotex Corporation Testing Service 520191-1 Static Uplift Testing March 1999 PA 101 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 2004 Walker Engineering, Inc. Evaluation Calculations 25-7094 Feb 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 25-7804b-8 1996 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Restoring Moment, Mg March 2004 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Nutting Engineers 13343.1 TAS 112 05/06/08 American Test Lab of South Florida RT1210.02-15 TAS 112 12/17/15 NOA No. 16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 3 of 6 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1(ft) Width w (ft) Entegra Flat Tile 9.7 1.33 .833 Table 2: Aerodynamic Multipliers - A, (ft3) Tile Profile )L (ft3) Batten Application (ft3) Direct Deck Application Entegra Flat Tile 0.189 0.205 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Entegra Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.53 6.97 6.43 6.86 6.29 ' 6.71 6.14 6.54 5.97 6.35 NOA No. 16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 4 of 6 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Entegra Flat 2-10d Ring Shank Nails 30.9 38.1 17.2 Tile 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 `#8-Screw_::721 51.7 r 55-9*7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" the headlap and fasterners are located a min. of 2Y2" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Flat Tile Adhesive 31.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. 3M." 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Flat 3M- 2-Component Foam Roof Tile Adhesive AH-160 118.94 Tile 3W 2-Component Foam Roof Tile Adhesive AH-160 40.45 4 Large paddy placement of 45 grams of 3W 2-Component Foam Roof Tile Adhesive AH-160 5 Medium paddy placement of 24 grams of 31VI'm 2-Component Foam Roof Tile Adhesive AH-160 NOA No. 16-0112.07 MIAMI•DADE COUNTY Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 5 of 6 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE BUILDING PERMIT REQUIREMENTS: As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice.of Acceptance on its own cannot be used to obtain a building permit. PROFILE DRAWING ENTEGRA "FLAT" CONCRETE ROOF TILE 16' 10" FIELD TILE i- 16" THICK BUTT TILE END OF THIS ACCEPTANCE NOA No. 16-0112.07 Expiration Date: 06/07/21 Approval Date: 02/25/16 Page 6 of 6 OWENS CORNING SCIENCE and TECHNOLOGY, LLC 2790 COLUMBUS ROAD, ROUTE 16 GRANVILLE, OHIO 43023.1200 December 14, 2017 CS 17-61 Mike Black MB Enterprises & Sheet Metal, Inc. 540 2nd Street SW Vero Beach, FL 32962 Dear Mike, r� weaving abetter wodd- Per your request, this letter is in reference to installation of 2 layers of InterWrapO Titanium® PSU30 self -adhering underlayment on the following project: 2456 Harbour Cove Drive Ft. Pierce, FL 34949 It is acceptable to install 2 layers of the aforementioned product provided the sidelaps are staggered Y-4" on each layer and backnailed @ 12" o.c. It is my understanding that the roof covering on this project is to be Entegra Bermuda tile. The aforementioned installation is acceptable and fully warranted under the conditions of the Limited Warranty. If you have any additional questions, please feel free to contact me. Regards, Gregory D. Keeler Technical Services Manager Owens Corning Science & Technology, LLC 740.321.6345 greg.keeler(a)-owenscorning.com OWENS CORNING