Generator Information
16/20/22 kW INCLUDES: • True PowerT" Electrical Technology • Two Line LCD Multilingual Digital Evolution'"' Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details —z S GENERAC® GUARDIANO SERIES mJ esidential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ST.LUCIE COUNTY • Electronic Governor PLAN REVIEW • System Status & Maintenance Interval LED Indicators BLDG:_ • Sound Attenuated Enclosure E: DATE: • Flexible Fuel Line Connector DATE: 0 Direct -To -Dirt Composite Mounting Pad PLUMB: • Natural Gas or LP Gas Operation DATE:___- • 5 Year Limited Warranty MECH:_ • Capability to be installed within 18" (457 DATE ml-TI) of a building* FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. c �us L Qv' LISTED " Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at :0%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this d SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC �at7�3ss jo ,�� 4�,A .I. _ • ®• *©� Mobil ' PROMISE - Gar�WEP `pQ• �QppP�` Link -Bud In the USA using domestic and foreign pelts. GENERAC® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'"" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW GENERAL' specifications Generator Model G007035-0, G007036.0, 13007038-0, G007039-0 11007042-1, G007043-1 G007037.0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (NG) 16,000 Watts* 18,000 Watts* 19,500 Rated Voltage, 240 240 240 -��� Rated Maximum Continuous Load Current -240 Volts (LP/NG) 66.6/66.6 _ 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5°k Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Number of Rotor Poles 2 2 2 Rated AC Frequency 66 Hz _ 60 Hz _ 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) � 12 Volts', Group 26ti 540 CCA Minimum or Group 35AN 650 CCA Minimum Unit Weight (lb/kg) 406/186 448/203 466/211 Dimensions (L x W. x H) in/mm _ 48 x 25 x 29/1218 x 638 x 732 ---� Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load;-- 66 66 67 Sound output in dB(A)at 231t (7 mj with generator in Cuiet-Test' low -speed exercise mode;' 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Farce 1000 Series Number of Cylinders _ 2 _ 2 2 Displacement 999 cc 999 cc 999 cc (Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w% Magneto Solid-state w%Magneto Governor System Electronic Electronic Electronic Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including;Filter ^� Approx.1.9 gV1.8 L Approx.1.9 gl/1.8 L Approx: l.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Natural Gas ft3/hr (m3/hr) 1/21cad 218 (6.17) 204 (5.78) 228 (6,46) Full Load 309 (8.75) 301 (8.52) 327 (9.26) Liquid Propane ON (gal/hr) [Vhr] 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8.99] 92 (2.53) [9.57] Full Load 106.8 (2.94) (11.111 129.6 (3.56) [13.481 142 (3.90) [14.7� Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel for LP gas. For Btu content, multiply fts/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Meg Controls 2-Line Plain Text Multilingual LCD Display water column (7-13 mm mercury) for natural gas, 10-1 2"water column (19-22 mm mercury) (93.15 (LP) or m3/hr x 37.26 (NG) user interface for ease of operation. stays on. If utility fails, transfer to load takes place. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Smart Battery Charger Standard _ Chargerfault/Nlissing ACWarning _ Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense -Loss Shutdown mm _ Standard High Engine Temperature Shutdown _y� _ Standard Internal FaulVlncorrect Wiringng Protection , - Standard Common External Fault Capability _ Standard _ Field Upgradable Firmware Standard ----------- **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on Installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 "C (60OF) r GENERAC® 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Model G007036-0 (16kW) No. of Poles 2 Current Rating (Amps)' 100 Voltage Rating (VAC) 120/240, 1H Utility Voltage Monitor (Fixed)` -Pick-up -Dropout 80% 65% Return to Utility', _ _ _ _ approx. l5 sec Exercises bi-weekly for 5 minutes`t Standard JUL Listed Standard Total Circuits Available 24 Tandem BreakerCapabilities 8 tandems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH Model G007037-0 (16 kW)/GO07039-0 (20 kW)/ G007043-0 (22 kW) No. o -Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)` -Pick-up -Dropout 80% 65% Returnto Utility* ap_prox.13 sec Exercises bi-weekly for 5 minutes* Standard UL'Listed Standard Enclosure Type NEMA/UL 3R Circuit Breaker Protected 22,000 Lug Range 250 MGM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly - DEPTH GENERAC 16/20/22 kW available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G007005-0 Wi-Fi LP Fuel Level Monitor Boring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S, only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. [2" hi LEFTSIDE VIEW (48.51.1 FRONTVIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENERAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194•F 5/3/17 Smart Management Modules (SMM) GENERAC° GENERAC° ACCESSORIES Model G006873-0 C@ US LISTED DESCRIPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if it falls below a certain threshold, the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage, therefore reducing the necessary size of the generator for a more cost effective solution. SMM SPECIFICATIONS PowerSupply Source ................................. ...............................................................................................,....................................................................,......240 VAC (from Line input) SupportedVoltages..........................................................................................................................................................................................................................................240 VAG Contactor Coil Voltage: ......................................................................................................................... ........ .......... ....... ............................................................ 240 oltage:.....................................................................................................................................................................................................................................240 VAC CoilVA Inrush...........................................................................................................................................................................................................................................................6 5 CoilVA Sealed.....................................,...........................,.....,.,.,.....,..........,...............,....,..................,.,,......,.,....,..............I........................ Poles.......................................................................................................................................................................................................................................................................... 2 ResistiveAmps.................................................................................. •......................................,...,.........,...,,....,.,........................................................ 50 F/L Inductive Amps................................................................................................ ....... ........................................................... 40 LockedRotor Amps.....................................................................................................................................................................................................................................240@240V UI50............................................................. I ........................... ...... .......... ,.................................. ..................................... I ............................. Yes Enclosure Rating .............................................................. ............... ............. ........ ............ ......... ...... ............................... NEMA 3R GENERAC® GENERAC® Smart Management Modules (SMM) Dimensions and UPC Model G006873-0 Height (INmm) H1 6.17/156.8 H2 2.36/60 W1 7.06/179.4 Width (INmm) W2 4.72/120 Depth (in/mm) 3.7/94 Weight (lbs/kilos) 2.06/0.94 Shipping Weight (ibs/kilos) 2.44/1.11 UPC Cade 696471068733 H1 SMM Controls (located behind the cover of the module) I LED ON = LOAD CONNECTED LED FLASH IIS = LOAD SHED PRIORITY LOCKOUT LED FLASH 3S = 30 MIN LOCKOUT 5 LOAD GENERATOR ON GENEfl LED FLASH 63 c GEN LOAD LOCKOUT 9 7 �— LED OFF = NO MODULE POWER A ® ® .o O TEST o LOCKOUT DISABLED Priority Dial (A) — Sets module priority. Lockout Switch (B) — Prevents load from operating when system is operating under generator power. Test Button (C) — Disables contactor output for a specified lime. LED (D) — Provides module status with easy viewing through the external viewing window located in the upper right corner of the module. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 a generac.com GE N E RAC` ©2016 Generac Power Systems, Inc. All rights reserved. All speclncations are subject to change without nonce. BulleOn OL1500-C 03/10/16 Site Selection and Preparation �edion 3: Site Selection and Preparation Site Selection Oi 5ft(1.52m) ®J'—(0.91 3 ff m) 5 ft (1,52 m) ® 1,--(0.913 ft m} 3 ft (0.91 m) D Figure 3-9. Installation Clearances ID Description Gommerds A Top of generator — 6 Front and end clearance Minimum clear distances cannot Include shrubs, bushes, or trees. C Rear clearance is . (4u^_7 cm) minlmvm clearance per NFPA testing, labelin and l dictate Otherwise. 9, +sang, unless state or local codes D Windows and openings NO operable windows, doors, or openings in the wall are ) from 1.52 m ft 5 permitted within the generator. ( any point of E Basting wag One -hour fire rated vualts allow closer placement of the generator set. Confirm before Instaffaffon. F Removable fence Removable fence panels for servicing cannot be placed less than 3 ft (0.91 rn) in front of the generator. G Overhead clearance 5 if (1.52 m) mfnlmutm distance from any structure, overhang, or projections from the well. DO NOT install under wooden decks or structures unless this distance Is maintained. tTs= M Installefion Guidelines For 60 Hz Air -Cooled Generators 11 Site Selection and Preparation install the generator set, In its protective enclosure OuWoors where adequate cooling and ventilating air !s always available (, :��r; ;;d:t). Consider these factors: ° The installation of the generator must comply strictly with ICC 1FGC, NFPA 37, NFPA 54, NFPA 68, and NFPA 70 standards, ° Install the unit where air inlet and outlet openings 1011 not become obstructed by leaves, grass, snow, etc, if prevailing winds will cause blowing or drifting, consider using is windbreak to protect theunit. Install the generator on high ground where water levels will not rise and endanger it. This unit should not operate in or be subjected to standing water. ° Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be Installed in accordance with any local, stare, or natianai codes for MIMM M dIeWces tOM other Structures. ° Clearance from the ends and front of the generator must be 3 it (0.91 m), This includes shrubs, bushes, and trees, Clearance from the back of the generator must be a min* rrtum of 18 in (457 mm). Clearance at the top should be a minimum of 5 ft (1.52 m) front arty structure, overhang, or projections from the wall. ° DO NOT install under wooden decks or structures unless there is at least 5 fi above the generator. t (1.52 m) of Clearance ° Install the unit where rain gutter down spouts, roof run -Off, landscape irrigation, water sprinklers, or A sump Pump discharge does not flood the unit or spray the enclosure, including any air inlet or outlet A openings. m Install the unit where services will not be affected Be Of obstructed, Including concealed, underground, av or covered services such as electrical, fuel, phone, ex air conditioning, or irrigation. This could affect an warranty coverage. ma ° Where strong prevailing winds blow from one e b direction, face the generator air inlet openings to the the preva€ling winds. ° install the generator as close as possible to the fuel NO suPOY to reduce the length of Piping. REMEMBER18 I THAT LAWS OR CODES MAY REGULATE TH(` DISTANCE AND LOCATION. In the absence of net local codes regarding placement or clearance, we agen recommend following these guidelines: The — install the generator as close as possible to the with transfer switch. REMEMBER THAT LAWS OR items CODES MAY REGULATE THE DISTANCE AND The LOCATION. ma er The generator must be installed on a level Sur. face. The generator must be level within a 0.5 In (13 mm) aft around. — The generator is tyP€caliy placed on pea gravel, compacted soil, crushed stone, or a concrete Pad. Check local codes to see what type is required. if a concrete pad is required, all appli. cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 Is the The National Fire Protection Assoclation's standard for the installation and use of stationary combustion engines. Its requirements limit the spacing of an enclosed generator set from a structure or wall (Pygz e . a f). NFPA 37, Section 4.1.4, Engines LOci1ted Outdoor$: Engines, and their w, &*erproof housings if provided, that are installed outdoors shall be looted at least 5 fit (1.52 m) h'om openings in walls and at least 5 fit east f from structures having combustible welts. 5 minimum separation Lion shall not be rsqulred where the following conditions exist: 1 • The adjacent wall of the structure has a fire resistance rating of at least one hour. 2. The weatherproof enclosure is constructed of noncombustible materials and It has demonstrated that a fire within the enclosure will not ignite combustible materials Outsiders enclosure. the nnex A -- Explanatory Material 4.1.4 (2) Means of demonstrating compliance are by Cans of full scale fire test or by calculation procedures. cause of the limited spaces that are frequently a"able for installation, it has become apparent that ceptlon (2) would be beneficial for many residentiai d Commercial insttMladons. Witt•, that in mind, the nufacturer contracted with an Independent testing oratory to run full scale fire tests to assure that the losure will not Ignite combustible materials outside enclosure. TE; Southwest Research Institute testing approve, n (467 mm) Installation minimum from structure sG-1, P. Southwest Research institute is a nai)y recognized third party testing and listing cy. criterla was to determine the worst case fire scenario n the generator and to determine the Ignitability of outside the engine enclosure at various distances. enclosure Is constructed of non.combusttbte leis, and the results and conclusions from the rdependsnt testing lab indicated that any fire within the 12 installation Guidelines For 60Hz Air Cooled Generators f generator enclosure would not pose any ignition risk to nearby combustibles or structures, with or Without fire service personnei response. L(Wa}Draa 7 Arta 7 NDTE s 43#J � MI 20=a =2 3 0 CHAR WM 4130 CM sots s t3D Wa v �4 N= 7 RD CHAR MEEPAa reset sirs M, rM Figure 3-2 Souiharest Research Insti€rate Narld�g :��;5;1$:Cf'?STr:vff!3!i+i:t•� �;Im Based on this testing and the requirements of iuFpA 37, Sec 4.1.4, the guidelines for installation of the generators Iisted above are changed to IS in (457 mm) from the back side of the generator to a stationary wall or bui eance, ralding (C). For adequate maintenance and airrriow cl the area above the generator should be at seas#5 (1,52 m) with a minimum of 3 ft (0.91 m) at the front and ends of the enclosure. This Includes trees, shrubs; and bushes. Vegetation not In clearance pare could obstructcompliance air flow.#h These with addition, exhaust fumes from the generator could inhibit plant gam. See ; =g�% = and the instal9a#ton drawing within the owner's manual for details. Automatic start-up. Disconnect utility power and render unit inoperable before working an unit. Failure to do so will result In death or serious Injury, (000191} Asphyx:a#Pnning engines producecarbon noxide, a colorless, odorless, poisonous gas. Carbon monoxide if C Site Selection anrr Site Preparation ° Locate the mounting area as close as possible t the transfer switch and fuel supply ° Leave adequate room around the area for service access (check local code), and place high enougl to keep rising water from reaching the generator. ° Choose an open space that will provide adequate and unobstructed airflow, . ° Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fens, or other air intakes (see a me ° Select the type of base, such as —but not limited to —.compacted soil, gravel, or concrete, as desired or as required by local taws or codes. Verify your local requirements before selecting. Material Suf [Clent for Level Installation Prepare a rectangular area approximately 5 in (127 mm) deep (A) and approximately 6 In (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface whore the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be Poured if desired or required. Figure 3 3, Compacted S011 or Gravel Pad avoided, will result in death or serious Injury. NOTE. If a concrete pad is required ppI (000103} federal, state, or local codes, follow all a lcable NOTE: If the generator is not set to OFF, it can crank and start as soon as the battery cables are connected. If the utility power supply Is not turned off, sparking can occur at the battery posts and cause an explosion. Installation Guidelines For 60 Hz Air -Cooled Generators is A — A ,, -r-; L i A Mf'^ L" r ;u; 6c4-ec..kcr ZOIN-e-4. 2!� 34 * to ppefTiq-j Yv _Ll 01 -,3% "$#/b &PP'n-T'Nww S#lo Copp«TNww Lw,. - 3/Ltof�r#10 C`��PtrT�Iwh1 ',+f 34 I It 1#-' 4- Optional Load Calculation Heat Larger Than Air goo SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 3 000 �"c► Refrigerator @ 150o Freezer @ 1500 — Washing Machine @ 1500 a Dishwasher @ 15oo l 0® Disposal @ 1500--- Mini Sewer @ 1500 Clothes Dryer @ S000 Range @ 1200o a Lt� sine - water hepter @ 4500 .Fixed -microwave @ 15oo m �-bA ,5►ec Vacuum @ 1500 Trash Compactor @ 1500 Pool Heater @'name plate' _—.� Spa @'name plate'mom Motors 746VA per HP Pao E t, S L, _ 19 Garage Door Opener G ao -------------- 1) 2) S) Total First 10 KVA of general load @ 100% 4) Subtract line 2 from 1 Multiply line 2 @ 40% 5) Add lines 2 and 4 6) 60/50amp breaker for heat (10000)' 7) 40/30amp breaker for heat (5000) _ `A. 8) Total heat- Add lines 6 and 7� 9) Multiply line 8 @ 65%yib 10) 11) Add lines 5 and 9 Divide line 10 by 240 _ � UZ/'7, % Summary: Line 10 Is the total KW line 11 is the total Amps ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELEC � DATE: 17 PLUMB:. MECH,_ DATE:_ (Generator size Needed) (Breaker Size Needed)