HomeMy WebLinkAbout21-1134 Paul Bobo Construction eSigned (3)BUILDING LOADS / DESCRIPTION:
WIDTH:
(BUILDING DIMENSIONS ARE NOMINAL. REFER TO PLANS).
THIS STRUCTURE IS DESIGNED UTILIZING THE LOADS INDICATED
AND APPLIED AS REQUIRED BY :
THE CONTRACTOR IS TO CONFIRM THAT THESE LOADS COMPLY
WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT.
ROOF DEAD LOAD:
COLLATERAL LOAD:
ROOF LIVE LOAD:
ROOF SNOW LOAD:
BASIC WIND SPEED:
SEISMIC ZONE:
IMPORTANCE FACTORS:
WIND LOAD
SNOW LOAD
SEISMIC LOAD
PSF (ROOF PANELS & PURLINS)
PSF
PSF
PSF
MPH
2.5
0.5
20.0
0.0
161
A
1.00
1.00
LENGTH: HEIGHT:40 50 17.8 / 17.8
FBC 2020 .
ROOF PANELS:
WALL PANELS:
TRIM COLORS:
LINER PANELS:
LINER TRIM:
COLOR:
COLOR:
CABLE:
CORNER:
EAVE:
FRAMED OPENINGS:
COLOR:
COLOR:
N/A
N/A
Cool White (SMP)
Cool White (SMP)
Old Town Gray (SMP)
Old Town Gray (SMP)
Old Town Gray (SMP)
Old Town Gray (SMP)
PROJECT:
JOB NUMBER:
PAUL BOBO
21-1134
BUILDER / CONTRACTOR RESPONSIBILITIES
APPROVAL NOTES
IMPORTANT NOTE: FINAL DETAILING, FABRICATION, AND DELIVERY DATE OF THIS PROJECT
CANNOT BE COMPLETED UNTIL THE SIGNED APPROVALS ARE RETURNED TO THE METAL
BUILDING MANUFACTURER.
GENERAL NOTES:
1) MATERIALS : MINIMUM YIELD:
HOT ROLLED BAR
STRUCTURAL STEEL SHEET
STRUCTURAL STEEL PLATE
COLD FORMED SHAPES
WALL SHEETING
ROOF SHEETING
BOLTS A307 & A325
THE METAL BUILDING MANUFACTURER RESERVES THE RIGHT TO
SUBSTITUTE THE ABOVE MATERIALS WITH EQUAL OR BETTER MATERIAL.
2) BOLT TIGHTENING REQUIREMENTS:
ALL HIGH STRENGTH BOLTS ARE A325 UNLESS NOTED OTHERWISE.
HIGH STRENGTH BOLTS SHALL BE TIGHTENED BY THE TURN OF THE NUT METHOD
IN ACCORDANCE WITH THE LATEST EDITION AISC "SPECIFICATION FOR
STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". A325 BOLTS SHALL BE
INSTALLED WITH OUT WASHERS WHEN TIGHTENED BY THE "TURN OF THE NUT"
METHOD. ALL BOLTED CONNECTIONS, FOR SHEAR/BEARING CONNECTION TYPE
WITH BOLT THREADS EXCLUDED FROM THE SHEAR PLANE SHALL BE SNUG TIGHT
ONLY.
3) ALL STRUCTUAL STEEL TO RECEIVE A RUST INHIBITIVE PRIMER. THIS PAINT
IS NOT INTENDED FOR LONG TERM EXPOSURE TO THE ELEMENTS.
1.00
Fy = 57.0000 ksi MIN.
Fy = 50.0000 ksi MIN.
Fy = 50.0000 ksi MIN.
Fy = 50.0000 ksi MIN.
Fy = 60.0000 ksi MIN.
Fy = 60.0000 ksi MIN.
THERMAL FACTOR:1.00
DEFLECTION LIMTS:
EW COL:
EW RAF LIVE:
EW RAF WIND:
WALL GIRT:
PURL LIVE:
PURL WIND:
WALL PANEL:
ROOF PANEL LIVE:
ROOF PANEL WIND:
RF HORIZONTAL:
RF VERTICAL:
WIND BENT:
RF CRANE:
RF SEIS:
WIND BENT SEIS:
180
180
180
90
180
150
60
60
60
60
180
60
100
50
50
IT IS THE RESPONSIBILITY OF THE BUILDER/CONTRACTOR TO INSURE THAT ALL PROJECT PLANS AND
SPECIFICATIONS COMPLY WITH THE APPLICABLE REQUIREMENTS OF ANY GOVERNING BUILDING
AUTHORITIES. THE SUPPLYING OF SEALED ENGINEERING DATA AND DRAWINGS FOR THE METAL
BUILDING SYSTEM DOES NOT IMPLY OR CONSTITUTE AN AGREEMENT THAT THE METAL BUILDING
SYSTEM MANUFACTURER OR ITS DESIGN ENGINEER IS ACTING AS THE ENGINEER OF RECORD OR
DESIGN PROFESSIONAL FOR A CONSTRUCTION PROJECT.
THE CONTRACTOR MUST SECURE ALL REQUIRED APPROVALS AND PERMITS FROM THE APPROPRIATE
AGENCY AS REQUIRED. APPROVAL OF THE METAL BUILDING SYSTEM MANUFACTURER'S DRAWINGS
AND CALCULATIONS INDICATE THAT THE METAL BUILDING SYSTEM MANUFACTURER CORRECTLY
INTERPRETED AND APPLIED THE REQUIREMENTS OF THE CONTRACT DRAWINGS AND SPECIFICATIONS.
(SECT. 4.2.1 AISC CODE OF STANDARD PRACTICES, 9TH ED.) WHERE DISCREPANCIES EXIST BETWEEN
THE METAL BUILDING SYSTEM MANUFACTURER'S STRUCTURAL STEEL PLANS AND THE PLANS FOR
OTHER TRADES, THE STRUCTURAL STEEL PLANS SHALL GOVERN. (SECT. 3.3 AISC CODE OF STANDARD
PRACTICE 9TH ED.)
DESIGN CONSIDERATIONS OF ANY MATERIALS IN THE STRUCTURE WHICH ARE NOT FURNISHED BY
THE METAL BUILDING SYSTEM MANUFACTURER ARE THE RESPONSIBILITY OF THE CONTRACTORS AND
ENGINEERS OTHER THAN THE METAL BUILDING SYSTEM MANUFACTURER'S ENGINEER UNLESS
SPECIFICALLY INDICATED.
THE CONTRACTOR IS RESPONSIBILE FOR ALL ERECTION OF STEEL AND ASSOCIATED WORK IN
COMPLIANCE WITH THE METAL BUILDING SYSTEM MANUFACTURER "FOR CONSTRUCTION" DRAWINGS.
ALL BRACING AS SHOWN AND PROVIDED BY THE METAL BUILDING SYSTEM MANUFACTURER FOR THIS
BUILDING IS REQUIRED AND SHALL BE INSTALLED BY THE ERECTOR AS A PERMANENT PART OF THE
STRUCTURE.
TEMPORARY SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSE WORK, CRIBBING OR OTHER
ELEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE DETERMINED AND FURNISHED AND
INSTALLED BY THE ERECTOR. THESE TEMPORARY SUPPORTS WILL SECURE THE STEEL FRAMING, OR
ANY PARTLY ASSEMBLIED STEEL FRAMING, AGAINST LOADS COMPARABLE IN INTENSITY TO THOSE FOR
WHICH THE STRUCTURE WAS DESIGNED, RESULTING FROM WIND, SEISMIC FORCES AND ERECTION
OPERATIONS, BUT NOT THE LOADS RESULTING FROM THE PERFORMANCE OF WORK BY OR THE ACTS
OF OTHERS, NOR SUCH UNPREDICTABLE LOADS AS THOSE DUE TO TORNADO, EXPLOSION, OR
COLLISION. (SECT. 7.9.1 AISC CODE OF STANDARD PRACTICE, 9TH ED.)
WARNING: IN NO CASE SHOULD GALVALUME STEEL PANELS BE USED IN CONJUNCTION WITH LEAD OR
COPPER. BOTH LEAD AND COPPER HAVE HARMFUL CORROSION EFFECTS ON THE ALUMINUM ZINC
ALLOY COATING WHEN THEY ARE USED IN CONTACT WITH GALVALUME STEEL PANELS. EVEN RUN-OFF
FROM COPPER FLASHING, WIRING, OR TUBING ONTO GALVALUME SHOULD BE AVOIDED.
THE FOLLOWING CONDITIONS APPLY IN THE EVENT THAT THESE DRAWINGS ARE USED AS APPROVAL
DRAWINGS: IT IS IMPERATIVE THAT ANY CHANGES TO THESE DRAWINGS BE MADE IN CONTRASTING INK
(PREFERABLY RED INK), HAVE ALL INSTANCES OF CHANGE CLEARLY INDICATED, AND BE LEGIBLE AND
UNAMBIGUOUS. A SIGNATURE AND DATE IS REQUIRED ON ALL PAGES. MANUFACTURER RESERVES THE
RIGHT TO RE-SUBMIT DRAWINGS WITH EXTENSIVE OR COMPLEX CHANGES REQUIRED TO AVOID
MISFABRICATION. THIS MAY IMPACT THE DELIVERY SCHEDULE. APPROVAL OF THESE DRAWINGS
INDICATES CONCLUSIVELY THAT THE METAL BUILDING SYSTEM MANUFAACTURER HAS CORRECTLY
INTERPRETED THE CONTRACT REQUIREMENTS, AND FURTHER CONSTITUTES AGREEMENT THAT THE
BUILDING AS DRAWN WITH INDICATED CHANGES REPRESENTS THE TOTAL OF THE MATERIALS TO BE
SUPPLIED BY MANUFACTURER. ANY CHANGES NOTED ON THHE DRAWINGS NOT IN COMFORMANCE
WITH THE TERMS AND REQUIREMENTS OF THE CONTRACT BETWEEN MANUFACTURER AND ITS
CUSTOMER ARE NOT BINDING ON MANUFACTURER UNLESS SUBSEQUENTLY SPECIFICALLY
ACKNOWLEDGED AND AGREED TO IN WRITING BY CHANGE ORDER OR SEPARATE DOCUMENTATION.
MANUFACTURER RECONGNIZES THAT RUBBER STAMPS ARE ROUTINELY USED FOR INDICATING
APPROVAL, DISAPPROVAL, REJECTION, OR MERE REVIEW OF THE DRAWINGS SUBMITTED. HOWEVER,
MANUFACTURER DOES NOT ACCEPT CHANGES OR ADDITIONS TO CONTRACTURAL TERMS AND
CONDITIONS THAT MAY APPEAR WITH USE OF A STAMP OR SIMILIAR INDICATIOIN OF APPROVAL,
DISAPPROVAL, ETC. SUCH LANGUAGE APPLIED TO MANUFACTURER'S DRAWINGS BY THE CUSTOMER,
ARCHITECT, ENGINEER, OR ANY OTHER PARTY WILL BE CONSIDERED AS UNACCEPTABLE
ALTERNATIONS TO THESE DRAWING NOTES, AND WILL NOT ALTER THE CONTRACTUAL RIGHTS AND
OBLIGATIONS EXISTING BETWEEN MANUFACTURER AND ITS CUSTOMER.
GROUND SNOW LOAD:PSF0.0
SNOW EXPOSURE:
WIND EXPOSURE:
1.00
B
DESIGN BASE SHEAR, V:
EXPANDED FORMULA
LONGITUDINAL
TRANSVERSE
0.667*Ie*Fa*Ss*W/R
0.28
0.24
Sds 0.05
Sd1 0.04
SITE CLASS:D
OCCUPANCY CATEGORY:II - Normal
SEISMIC DESIGN CATEGORY:A
SPECTRAL RESPONSE COEFF.
Ss 0.05
S1 0.03
MAPPED SPECTRAL RESPONSE ACC.
INTERNAL PRESSURE COEFF.:
0.18 -0.18/
52 Apex Dr. Jefferson, GA 30549
Ph. 888-346-2426 mavericksteelbuildings.com
Page 1 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 2 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 3 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 4 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 5 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 6 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 7 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 8 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 9 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 10 of 14
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 11 of 14
SECTION THRU ENDWALL RAFTER
END OF BUILDING
GABLE RAKE ANGLE
ROOF PURLIN
ENDWALL
RAFTER
#12 S. D. SCREW
BOLT, 0.5"
BY 1"(TYP)
WELDED PLATE
A7
ENDWALL
RAFTER
ENDWALL COLUMN
BOLTS, 0.50"
BY 1.50"
ENDWALL RAFTER TO COLUMNB4
(ONE SHOWN, TWO
MAY BE USED)
ENDWALL RAFTER
CORNER COLUMN TO ENDWALL RAFTER
ENDWALL COLUMN
B16 GIRT TO COLUMNC6
COLUMN
GIRT
WELDED
PLATE
PLATE
CORNER COLUMN
ENDWALL GIRT
SIDEWALL GIRT
CORNER COLUMN TO WALL GIRT
BOLT, .5"x1.0"
WELDED
D4
W R COLUMN
CORNER COLUMN TO WALL GIRTD17
PLATE
WELDED
GIRT
SIDEWALL
ENDWALL
ANGLE
WELDED GIRT
BASE PLATE FOR ENDWALL COLUMN
ENDWALL COLUMN
BASE PLATE
E3
PLAN ELEVATION
COLUMN OR DOOR JAMB
BASE PLATE TO ENDWALLE5
ELEVATIONPLAN
BASE PLATE
COLUMN
ENDWALL ENDWALL
COLUMN
BASE PLATE
PLAN ELEVATION
E8 BASE PLATE FOR ENDWALL
COLUMN OR DOOR JAMB
ENDWALL
RAFTER
RAFTER SPLICE AT SURFACE CHANGEF20
ENDWALL
COLUMN
ROOF PURLIN TO INTERIOR FRAME RAFTER
RAFTER
FRAME
RIGID
BRACE
FLANGE
RAFTER
PURLIN
ROOFBOLTS, 0.5"
x 1.0" (TYP)
G2
PLATE
WELDED
WALL GIRT TO FRAME COLUMN
WALL GIRT
H2
FLANGE
BRACE
COLUMN
BOLTS, 0.5"
x 1.0" (TYP)
FRAME
COLUMN
I8
0.5" x 1.0"
BOLT, TYP.
ENDWALL RAFTER
#12 S. D. SCREW
ANGLE
RAKE
GABLE
EAVE STRUT
EAVE STRUT TO ENDWALL RAFTER EAVE STRUT TO RIGID FRAME
SECTION ELEVATION
EAVE STRUT
FRAME
COLUMN
BOLTS,
J2
EXTENSION OF
TOP FLANGE
0.75"x1.25"
WALL GIRT TO DOOR JAMB
WALL GIRT
WELDED PLATE
K3
DOOR JAMB
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 12 of 14
SECTION ELEVATION
DOOR JAMB TO WALL GIRT
DOOR
JAMB
WALL GIRT
BOLT,
0.5" x 1.5"
L8 L108 JAMB TO ENDWALL RAFTER FLANGE
JAMB
CONNECTION PLATES
ENDWALL RAFTER
M4 HEADER TO C JAMB
WELDED
PLATE
JAMB
HEADER
SECTION ELEVATION
COLUMN OR
RAFTER WEB
SHOP CLAMP ON CABLE
CABLE
EYEBOLT
SLOT IN WEB TO INSERT
HILLSIDE WASHER
AND EYEBOLT
HILLSIDE
WASHER
FLAT
WASHER
NUT
DIAGONAL CABLE, EYEBOLT ENDQ2 R2 ANCHOR BOLTS AT SIDEWALL COLUMN
ELEVATIONPLAN
SIDEWALL COLUMN
BASE PLATE
BOLTS
ANCHOR
(AS NOTED)
MEMBER SCREW SPACING
MEMBER SCREW SPACING
(AS NOTED)
T1
BASE TRIM
BASE ANGLE
IN THE REACTION REPORT.
TO SAFELY RESIST THE LOADS
BY OTHERS, MUST BE ADEQUATE
AND CONCRETE FOUNDATION
SECTION THRU WALL PANEL
FOUNDATION
CONCRETE
WALL PANEL
WALL PANEL
BASE ANGLE
FASTENER
FASTENER
BASE TRIM
CLOSURE ANCHOR
SEALANT
BASE SEAL
TRIM_74
GABLE
FASTENER
PURLIN
ROOF PANEL
SEALANT
FASTENER
WALL PANEL
FASTENER
TRIM
CLOSURE
FASTENER
FASTENER
ANGLE
SHEETING
SEALANT
TRIM_229
WALL PANEL
SEALANT
TRIM
CLOSURE
FASTENER
FASTENER
HEADER
HEADER
TRIM_232
HEADER COVER
FASTENER
HEADER COVER
HEADER
WALL PANEL
TRIM_235
WALL GIRT
TRIM
FASTENER
JAMB
JAMB
WALL PANEL FASTENER
TRIM_239
WALL GIRT
JAMB
JAMB COVER
JAMB
WALL PANEL
COVER
TRIM_242
RIBBED ROOF PANEL
EAVE STRUT WALL PANEL
EAVE TRIM
TRIM_316
EAVE TRIM
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 13 of 14
PURLIN
FASTENERS
(3 PER FOOT)
3/16"X3/4"
MASTIC
RIDGE PANEL
RIDGE PANEL
TRIM_320
EAVE STRUT
FASTENERS
(2 PER FLAT)
FASTENERS
(ONE PER FLAT)
GABLE ANGLE
GIRT
CORNER TRIM
BASE ANGLE
FASTENERS
(2 PER FLAT)
CLOSURE FURNISHED
ONLY WITH SEALED
WALL OPTION.
1/2"
CORNER FLASHINGTRIM_323
TOP BOLTS, SEE
DRAWING FOR SIZE
BOTTOM BOLTS, SEE
DRAWING FOR SIZE
INTERMEDIATE BOLTS,
WHEN REQUIRED.
AND QUANTITY.
AND QUANTITY.
U2 BOLTED END PLATE CONNECTION
AT BUILDING PEAK
EXTENSION BEYOND FLANGE IS
OPTIONAL, AT TOP & BOTTOM.
U3
TOP BOLTS, SEE
DRAWING FOR SIZE.
BOTTOM BOLTS, SEE
DRAWING FOR SIZE.
INTERMEDIATE BOLTS,
WHEN REQUIRED.
AND QUANTITY.
AND QUANTITY.
TOP FLANGE
WEB
BOLTS FOR RAFTER TO
COLUMN CONNECTION
BOLTED
END PLATE
BOTTOM
FLANGE
859 Legg Road Jefferson, GA 30549
Ph. (706) 367-1412 allsteelconstruction.net
Page 14 of 14