Loading...
HomeMy WebLinkAboutCarport Installation PlansFBC APPROVED PRODUCE \,)LIST MAXIMUM PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL ALLOWABLE No. & DATE WIND SPEED STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL20717._1, 180 26 Gauge AG Panel 10/13/16 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL20727:1 180 26 Gauge AG Panel 10/13/16 STRUCTURAL COMPONENTS FLOOD VENT FLOOD FLAPS, LLC FL17381.1 NA 616 Flood Flap 11/12/15 EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.3 139 Series 402-14 _ 09/07/15 EXTERIOR DOORS SWINGING ELIXIR. DOOR AND METAL COMPANY FL17996.5 176 Series 407 09/07/15 -EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1 160. Model 203: 05/31/15 WINDOWS SINGLE HUNG' POCAHONTAS ALUMINUM COMPANY, INC. FL12940.2 139 Model 100 VS' 01/061.16 WINDOWS SINGLE HUNG. MI WINDOWS AND DOORS FL17499A 180 Model 185 SH ' .. 08/05/16 .. TABLE.1! . RAFTER FRAME,, END POST, GROUND ANCHOR AND PANEL FASTENER. SPA CING:SPECIFICATIONS . - AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS "OR AND POSTS OR GIRTS MAXIMUMPURLINS; (INCHES) WIND ULTIMATE NOMINAL POST / RAFTER INTERIOR. END" " RISK EXPOSURE WIND SPEED WIND- SPEED SPACING CATEGORY CATEGORY, (MPH) (MPH)- (FEET) " PASTS/RAFTERS POSTS/RAFTERS 6. Cam, METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING, AND FASTENER SPECIFICATIONS THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS -REQUIRED BY FIELD INSPECTORS THAT FOR CONSTRUCTION IN. THE MAY BE NECESSARY.IN ORDER TO ' STATE OF FLORIDA COMPLY WITH ALL APPLICABLE CODES. PREPARED FOR: CAROLINA CARPORTS; INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 CONCEALED. FASTENERS OR ATTACHMENTS_ PREPAREDBY.- BECHTOL ENGINEERING AND TESTING, INC. ARE THE RESPONSIBILITY'OF THE 605 WEST NEW PORK AVENUE CONTRACTOR. OF RECORD oEAND, FLORIDA 32720 Certificate of Authorization No. 00005492 151 TO 180 117 TO 139 -4.0 6 6 DETAIL8.1 C AND 1"D SHOWN ON SHEET 4 OF 5. NOTES:. 1. Specifications applicable to gauge metal roof and wall panels fastened directly to 12 or.14 gauge steel tube framing, or 18 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7" to.27" (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may.yary. GENERAL NOTES: . 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS: 2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE, AND INSTALLATION OF DOORS, WINDOWS OR OTHER -COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST ON THIS SHEET, AND NOT PROVIDED AND, INSTALLED BY CAROLINA CARPOETS, INC. SHALL BE AT THE OWNER'S. RISK. BECHTOL ENGINEERING' AND TESTING, INC., 'SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS OF NON -APPROVED COMPONENTS:. 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 4• FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH'CONTROL SEAL WASHER @ 6" O:C. AVERAGE. 5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4' SELF DRILLING. SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 6• CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERYPOST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR cbNCRETE SLAB CONSTRUCTION, EXCEPT AS SHOWN ON DETAIL 1 E. SHEET 4 OF 5, WHERE BASE RAIL IS FLUSH WITH EDGE OF SLAB. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. 8. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9• POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) (FBC FE 2014) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC FE 2014 - BUILDING. 11. 14 GA FRAMING IS 2-1/2" x 2-1/2' TUBE STEEL (TS). NIPPLES ARE 2-1/4" x 2-114" 12 GA TS FOR 14 GA FRAMING. 12 GA FRAMING IS 2-1/4" x 2-1/4" TS. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING: GROUND. ANCHOR SCHEDULE .. . ULTIMATE WIND SPEED:(mph) 110...1w •' 140 .150 1.60 170 : 1.8D 12 w 14- 30". Anchor ,a��i Detaif�D Ix..1:8 48"Anchor Detail-1C ft-28. 60" Anchor Detail 1 C- 7 // -d 34!00 ST. LUCIE' COUNTY ELiI-DE =' nwln ' REVIEWED FOR C LIA E REVIEWE DATE" PLANS ArD PERMIT �NST BE IaPT ON JOB . T INSPECTION WILL BE MADE. THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE. FLORIDA BUILDING.CODE' FIFTH EDITION (2014). THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE.. -r41flAAA/ 605 WEST NEW YORK NE • � .4; i DpJWD FLORI " �Lo 2N CertlBcate of n Ilo y. Thomas •9j, : O FbMa uco.rw N Ffle /lllllll\ CAROLINA CARPORT$, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA 0 °p .8/30/17 HECHTOL. ENGINEEMNG w" RR_ NTS " . CW MT6 G MMMWO U. a R04biru. M MMALs MMus DO c � TB "�"n G'17001 o.rrmwma,� ao®eam . AP ' TB SHEET 1 OF 5' 'BOW FRAME RAFTER'(? ,°EN CARPORT - HORIZONTAL ROO'. BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF .rOW FRAME RAFTER UTILITY BUII- - q,;.IG - HORIZONTAL ROOF ROLL UP DOOR SWINGING DOOR ROLL -UP DOORSWINGING DOOR (As applicable) (As applicable} (As applicable) (As appliicable) c e ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICALSIDE ELEVATION. TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT, TO SCALE NOT TO SCALE .BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSE®•BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY B.LDG - HORIZONTAL ROOF ROLL -UP DOOR SWINGING DOOR .. ROLL -UP DOOR SWINGING DOOR (As applicable). :(As applicable) (As applicable) (As applicable) ENC O ED NGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END. ELEVATION .. TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT. VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG VERTICAL ROOF i4djMA �F_RA111E Rti4FTER'�TIL;ITY B1 DG ROOF.�� _VERTIC�4L ROLL -UP DOOR SWINGING DOOR ROLL=UP DOOR SWINGING DOOR NMI I Imm (As applicable) (AS applicable)- (As (As applicable) .applicable) . ENCLOSED ENG ARIES � a�i TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL:SIDE ELEVATION. TYPICAL END.ELEVATION TYPICAIZ 12 TION �=JTYPICAL END ELEVATION` NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE _ - �e�r�rrn�enei c __r^ __-- � _1: — _.---%�=Nl1T=Tn _Sf.AI'�"� DELAND, FLORID _•'', Cef ficats of . No a -fto i l _ mas Badttol, Florida Lloense No. ` d ,`a •` ep -20 CAROLINA CARP6R1 GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION 8/30/17 NOT TO SCALE NOT TO SCALE NOT TO SCALE BECIMOL ENGINEEJUNG RR WAM NTS RAND TIt MN4 Eta eofStiunlo cmiaaW�u. Wvu�o UMMI., Mm Wm+ws TWM ENWMM TB G17001 °iWmft°N.0X0= TB SHEET 2OF5 4 , r-26 28 GA. GALVANIZED METAL ROOF PA� ASTENED 26 GA: GALVANL _ . ETAL ROOF PANELS FASTENED GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS WITH #12-14 x 3/4° SDFs WITH CONTROL TO RAFTERS WITH #12-'14 x 3/4' SDPs WITH CONTROL TO PURLINS WITH #12-14 x 3/4° SDFs :..,.. JONTROL SEAL WASHER @AVERAGE 6° O.C. SPACING SEAL WASHER Q AVERAGE 6° O.C. SPACING SEAL WASHER Q AVERAGE 6' O.C. SPACING 2 12. . Q3 z 12 - - 1-1/2°18 GAUGE FURRING:. 11 .. 4 4 CHANNEL e 2 ✓ 16 GA U-CHANNEL'BRACE 24° 16 GA U-CHANNEL BRACE �= TENED TO RAFTER WITH ' 7SPAN FASTENED,TO RAFTER WITH �! l _ 12-14 x 3/4 SDFs AT (2) #12-14. x 3/4" SDF's AT �24 16 GA U CHANNEL�BRACEI w H END (4 PER BRACE). _ EACH END (4 PER BRACE (. )_)#12140 S _� �, SEE w J 3/04 SDFsA ��r '� TABLE 1 SHEET 0 e RAFTER -SPAN SINGLE RAFTER >24' REQUIRES A TRUSSED RAFTER a 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER .24' 70 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER C) BEACH END 4 PER B _ - ( RACE - "~ - ,- -_ �- - 1 OF 5 - pN ONTF115 SHEET" .. 4 Q : AS SHOWN ON T}IIS SHEET' .. .q 24' MAXIMUM RAFf£R 5P'AN ON S RALEI FTER NG - . - .. �. -`t- - >24' TO, 30' RAFTER SPAN RECUR2ES A TRUSSED RAFTER. —z ' AS SHEET _ _ - - y :. �. p SHOWNON THIS TYPICAL F TYPICAL INTERIOR RAFTER/POST INTERIOR RAFTER/POST FRAME SECTION-' BOW FRAME FRAME SECTION = BOX EAVE.- HORIZONTAL ROOF = = :G TYPICAL BOW RAFTER GABLE END FRAMING PLAN. NOT TO SCALE NOT TO SCALE t �TAY,PXAL INTERIOR - NOT TO SCALE -- R� ' - - FTER/PO�JT FRAME'SECTION VERTIC =R00 '11 TYPICAL RA NOT TO SCALE NO'TVSCAL•EO_W_- ik•- J - s— - - LENGTH VARIES DEPENDING ON "' LENGTH VARIES DEPENDING ON -DRILLING 1-1/2° 18 GAUGE FURRING CHANNEL FASTENED T.O EACH RAFTER WITH (2)#12-14 x.3/4° SELF NUMBER AND BRACING OF RAFTERS NUMBER AND SPACING OF RAFTERS' FASTENER •SPACED NOT MORE THAN 48' O C. SEE .. TABLE 7 'SHEET 1OF5. .. 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURAL HEADER 10- (TYPICAL) AN BOW FRAME SEE TABLE 1 SHEET .'10F5 . 4' - .. TYPICAL RAFTER/POST FRAMING PLAN - BOX EAVE NOT TO SCALE —OPENING FOR SWINGING DOOR WITH NONSTRUCTURAL HEADER OPENING FOR WINDOW WffH _ .NONSTRUCTURALHE)= TYPICAL SIDE WALL OPENINGS FRAMING PLAN AND WIN End RAIL NOT TO SCALE' 24° 16 GA U-CHANNEL BRACE ' FASTENED TO RAFTER 1NITH (2) #12-14 x 3/4° SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) SEE ,. TABLE 1 SHEET 3 1OF5 4 LENG VARIES DEPENDING ON NUMBER . AND SPACINGOF RAFTERS TYPICAL POST/RAFTER FRAMING'PLAN - VERTICAL ROOF - NOT TO -SCALE. SEE TABLE 1 SHEET TYPICAL END WALL OPENINGS POST/RAFTER FRAMING PLAN NOT TO SCALE - 6" WELD ALL WEB CONNECTIONS, BOTH SIDES , TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT -TO. SCALE. 1-1/2°18 GAUGE FURRING CHANNEL FASTENED FULL 6' WELD TO EACH: RAFTER.V✓ITH (2) #12-14 x 3/4" SDF BOTH SIDES' SPACED NOT MORE THAN 48° O.C. OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOW NOT -TO SCALE ' ROOF EXTENSION OPTION MAIN STRUCTURE STANDARD LEAN-TO OPTION TYPICAL LEAN-TO OPTIONS FRAMING PLAN (BOTH OPTIONS SHOWN) OPTIONAL 24"A" TO 30' TRUSSED RAFTER - BOX EAVE NOT TO SCALE(BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS APPLICABLE TO BOW FRAME RAFTER) NOT TO SCALE 2A/4" FOR 12 GA FRAMING 2-1/2° FOR 14 GA FRAMING 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST. AND RAFTER WITH (2) #12-14 x 3/4° SOPS AT EACH END (4 PER BRACE) — BRACE SECTION Not To Scale SECHTOL,E C-hINGESTI 605 WEST NEW YO �(ENUE • ; �• , FLORID_A �20: �i fliomea •� ' {It Florida Llcens®No. CAROLINA CARPORTS, Sy ILA C6 GENERIC PLANS FOR USE IN THE STATE OF FLORIPA 8/30/17 vBECHTiOL EMOINEEWNG RR ' NTS AND 7F.871NG /nt TB. eOLd G17001 eameatdNo 4mn�ortur+u. WiMI41MIk AW Wmnus �myo D - - APPWW'� TB SHEET 3 OF 5 I INSTALL 1/7 x MINIMUM 51/2' EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER POST ALONG SIDES OR INSIDE EVERY OTHER END WALLPOST ALONG END WALL SECTIONS MINIMUM 2-1/4' EMBEDMENT - .GROUNDSURFACE Ste- '`, _ • \� //`t�%\\\/�\i�\ .�� MONOLITHIC CONIC. FOOTING (400 PSI MIN.) REINFORCED WITH (2) t15s CONTINUOUS' (SEE NOTE 6; SHEET 1 OF 5)' ��AkRl- NMF ST WONO SLA `B BASE'`RRIL _�,1NCHORA'GP - t . — .: - DRILL 5/8' HOLE THROUGH THE 2' WASHERS . 'BASE RAIL AND SECURE TO ANCHOR EYE WITH.I& DIAMETER TS CONTINUOUS THROUGH -BOLT. BASE RAIL I (SEE GROUND ANCHOR MINIMUM 4" : SCHEDULE, SHEET 1 OF5, FOR;REQUIRED ANCHOR) . ZCONTIM.UOU84" CONCRETE PAVEMENT * EYE ANCHOR CONCRETE BASE RAIL ANCHORAGE. 1 Not To Scale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT MEET'MIN 'mum EDGE DISTANCE SHOWN IN DETAIL 113) TS TRUSSED RAFTER CHORD,,, �S R NONTRUCTURAL HEADER TS END POST OR DOOR/ WINDOW FRAME POST 2"x2"x2° 16 GA ANGLE CLIP SECURE TO POST (EACH SIDE) TS BASE/WINDOW RAIL OR AND RAFTER CHORD/RAIL WITH NONSTRUCTURAL HEADER (4) #12-14 x 3/4" SDPS, (2)1014 TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST -TO RAIL,, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL / Not To Scale INSTALL 1/2' x MINIMUM 5 1/2' EXPANSION ANCHOR DRILL 5/8' HOLE THROUGH THE \ THROUGH BASE RAIL WITHIN W OF EACH ? WA9 max=^ DRILL HOLE D SECUR THE RAFTER POST ALONG SIDES BASE RAIL AND SECURE TO BASE AND SECURE TO ANCHOR EYE WITH 1%2' DIAMETER TS CONTINUOUS ANCHOR EYE WITH 1/Z DIAMETER THROUGH -BOLT BASE'RAIL THROUGH -BOLT' MIN. 6' TOP OF ASPHALT PAVEMENT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE OR STABLE GROUND SURFACE '2" WASHERS /- TS :CONTINUOUS / BASE RAIL MINIMUM 2-112- EMBEDMENT \ . . .1 . . - EYE ANCHOR, C .: 5/8' ROD 48" LONG WITH 6° HELD( OR 5/8' ROD 60' LONG (SEE GROUND ANCHOR. EYE ANCHOR (SEE GROUND ANCHOR MINIMUM 4' WITH r HELDI, SCHEDULE, SHEET 1 OF 5• SM' ROD_30' LONG SCHEDULE, SHEET 1' OF 5, AS APPLICABLE': FOR REQUIRED ANCHOR) WITH DBL 4 HELDC' F.OR APPLICABILITY) CONTINUOUS 4' CONCRETE PAVEMENT ET BASE RAIL ANCHORAGE. S-`��ECON�?CRETE roPnoruL,oPENcARPoRTsoNIY) 1�CA SE:I�AIL DEEP ANCHORAGETo Seale ` . Not To Scale 24- 16 GA U-CHANNEL BRACE (5 TO T POST) 48' 16 GA;U-CHANNEL BRACE (VTO 14' POST) :. . TS BOW RAFTER BRACE ANGLE SHALL BE MIN. 45° TO MAX. 60° FROM HOAl2ONTAL. NO SCREWS REQUIRED NIPPLE TO 3/16' IN BOW BEND 5' RAFTER: ° ,- 4' 16 GA U-CHANNEL BRACE (6 TOT POST) - TS RAFTER 48"' 16. GA U-CHANNEL BRACE (8' TO-14 POST) 9-1/2" BRACE ANGLESHALL BE MIN. 45' TO MAX.:60° FROM HORIZONTAL NIPPLE TO . BASE.RAIL 6'.LONG TS.NIPPLE 6" ° 3.. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/44 SOPS 36' LONG TS NIPPLE SECURE RAFTER AND POST TO ° NIPPLE WITH (4) #12-14'x 3/4'' TS RAFTER POST 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDFs TS RAFTER POST i ° TS CONTINUOUS'BASE RAIL TS RAFTER POST SELF.DRILLING FASTENERS BOXEVATRPODAIL BWRTROSDAL POST/BASE BASEA.CONN. DETAIL NotTo'Scale . TS RAFTER POST -1-1/2" x 1-1/2" x2" 16 GA CLIP ANGLE SECURE TO POST AND'BME RAIL WITH (4) #12-14 x 3W SDFs, (2) ONTOP, (2) ON SIDE V-TS CONTINUOUS BASE RAIL -`'��ND POST/BASE BAIL CONN. Not To Scale TS POST 2' x 2" x 2' 16 GA ANGLE CLIP SECURE TO POST AND TOP.OF HEADER, OR BOTTOM OF.WINDOW RAIL/GIRT-WITH (4) #12-14 z 3/4" SDFs (2)_ON TOP OR BOTTOM, (2) ON SIDE TS NON-STRUCTURAL HEADER VOW 6DS.WEST NEW YNORiQtL®UI��a /�N® T�OTIFIIG, , DELAND. FLORIDA. 3EiZOn v�� m ' Certificate of ri492 Floritle lfceD$e o.E'. Y .•."/�'q '� TS-WINDOW RAIL (OR GIRT r Ulu 14— lu f ' FOR VERTICAL SIDING OPTION) NON-STRUCTURAL HEADER, WINDOW CAR®LItVA CARPORTS, INC. ��� RAIL, OR GIRT TO POST CONN. DETAIL GENERIC PLANS FOR USE IN THE STATE OF FLORIDA V Not To Scale - .®a ure .8/30/17 ABECHTOL ENGINEERING °'"'� RR ' NTS MU 1 mllt� 6,e ' caNsa ero c9ormearu DamoHUcNw: ma w o us mina Dalmom o� �`w G 17001 o.rra inmomm ""'O1'� TB SHEET 4 OF 5 / I i NIPPLE TO 3/16" DBL. HDR. AFTER POST 6" LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4' SELF -DRILLING FASTENERS O° 6" LONG TS NIPPLE 16 GA ANGLE.CLIP SECURE EACH WITH NG :TS NIPPLE2"x2°z2" TS POST SECURETO:POST.AND (4) #12-14 x 3/4° RE WITH (4) #12-14 x 3/4' RAFTER.WITH'(4) #12-14 x3/4" SELF -DRILLING FASTENERS=DRILLING FASTENERS SDP's,_(2) ONBOTTOM,2) *3/16' ON SIDE OR. 16 GA PLATE iTS r r2x4' BASE RAIL SECURETO EACH SIDE OF o i o .' LE TS HEADERo0 TS END POST POSTIRAFTER CONNECTIONWITH (4) #12-14 x.3/4"SDFs,. _7u(2) ON POST, (2) ON RAFTER.. TS POST NIPPLE TO DBL. HDR: 3/16° NIPPLE TO BASE RAIL RAFTER.PSTIBASE END POST/RAFTER CONN.- DETAIL 7 . RA FT �ER POST/DBL. HEADER DETAIL ' EADER DETAIL RAFTER'P.OST/H,. BASE RAILCONNECTIONDETAIL Not To Scale Not To Sca)e, . 9 Not To Scale 1 Not To Scale ' 1-1/2' x 1-1I2"x 2° 16 GA CLIP'ANGLE SECURE TO RAFTER.POST AND GABLE RAIL.WITH (4) #12=14: x 3/4' SDFs, NIPPLE 1 TOP AND BOTTOM -RAFTER TS RAFTER 12" LONG TS NIPPLE.. � SECURE POST TO NIPPLE 1_ 1/2° x' 1=1%2 x 2" 16 GA CLIP WITH (4) #12=14 x 3/4° SDF's, AND• GABLE RAIL WITH (4) ANGLE SECURE TO RAFTER 1-1/2" x1-1/2' x 2' 16.GA CLIP ANGLE .. . #12-14 x 3/4' SDFSECURE T0RAFTS s,.(2) ON TOP, R AND GABLE -. 1-1/2'x 1-1/7 x 2" 16 GA (2) ON BOTTOM RAIL WITH (4)#12-14 x 314" SDFs', CLIP ANGLE SECURE TO .. (2) ON TOP, (2) ON BOTTOM RAFTER POST AND GABLE RAIL WITH (4) #12=14 x 3/4" SDP's (2) ON TOP. , (2). ON SIDE TS GABLE RAIL 24" 16.GA U-CHANNEL BRACE (5 TO T POST) TS RAFTER POST 6° LONG TS NIPPLE 48° 16 GA U CHANNEL BRACE (8' TO 14' POST) SECURE RAFTER AND POST' . TS GABLE RAIL BRACE ANGLE SHALL BE. MIN. 45' TO NIPPLE WITH 4 #12- 14 3/4" TO MAX 60° FROM HORIZONTAL 6' LONG TS NIPPLE SECURE WITH (4) #12-14 x 3/4" SDP's O x — SELF -DRILLING FASTENERS TS RAFTER POST GABLE RAIL TO RAFTER POST TS RAFTER. POST CONNECTION DETAIL SIDE EXTENSION r ~ Not To Scale GABLE RAIL. TO -RAFTER POST RAFTLR/POST ®ETAIL. CONNECTION DETAIL 12 NotTuSca�e ROLL -UP DOOR GUIDE TO POST CON CONNECTION DETAIL Not To Scale CURTAIN: 26 GA. galvanized steel with baked on epoxy pdmer.& polyester top coat. II I II II 1 I I SWINGING DOOR I 1 INTERIOR (Siie varies, see plan) A 031 SECTION Not To Scale #12-14 x 3/4' SDF @ 12- O.C. TS RAFTER POST 2"x4' 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" ;SDP's, (2) ON POST, (2) ON RAFTER __�TS,LEAN-TO RAFTER .... .... ........... .......... q 2•x2°x2' .16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 347. SDF's, (2) ON RAFTER, .(2) ON POST' 13 POST / LEAN-TO RAFTER-CONN. DETAIL J Not To Scale BECHT'LEC HI$ 4R4TES T o •N JI�m 605WESTNE DELAND,FLORM� �tS�, m Certificate of _ gNo. 5492. * • _ sBest ol, o. #Flood_LlcenseN • q • • * \� /, , NG INS ..��. "1I11111W, ' J CAROLINA CARPORT' , INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA `� °"e 8/30/17 BEtrHTOL ENGINEERING RR NTS - AND 7F8MG Ina mNsmiMo aonceaicu: wvozoNllurta. am Wm+ws mlwo waam+s TB G17001 ��" "1"i°� TB SHEET 5 OF 5