Loading...
HomeMy WebLinkAboutProduct Approval Exterior Doorsn ,tom .n.w..:c:.s.�sM..�.�...,...........�,, BC15 Home ;Log In ;User Registration ? Hot Topics j Submit Surcharge Stats &Facts Publications FBC Staff BCIS Site Map i Links Search I; k Product Approval HP2br %-im USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail s FL # , - 23 Application Type Revision Code Version Enm9w. Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method S� PIG-T,.I,.nd��ustries 070 el e1 T�chnolDrive North Venice, FL 34275 (941) 486-0100 Ext22318 druark@pgtindustries.com ]ens Rosowski jrosowski@pgtindustries.com ]ens Rosowski 1070 Technology Drive Nokomis, FL 34275 (941) 486-0100 Ext 21140 jrosowski@pgtindustries.com Exterior Doors"1 ' - S inging Exterlor Doo Holies, ,- Certification Mark or Listing Keystone Certifications, Inc. Steven M. Urich, PE LAG Validation Checklist - Hardcopy Received Standard AAMA 450 AAMA/WDMA/CSA 101/I.S.2/A440 ASTM E-1886 ASTM E-1996 ASTM E-1996 Method 1 Option A Year 2010 2008 2005 2009 2012 File Copy Date Submitted 06/08/2017 Date Validated 06/09/2017 Date Pending FBC Approval Date Approved 06/14/2017 Date Revised 11/07/2017 Summary of Produ cts FL # Model, Number or Name Description 33'i!1 GD-29'�i Aluminum Hinged Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331' R12 C CAC FD-290 Certification.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/21/2018 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 II FD-290.1)df pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 58705 Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-290 Evaluation.odf Created by Independent Third Party: No 331.2 FD-5455 Vinyl French Door & Sidelite/Transom Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331 R12 C CAC Certification FD 5455.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/21/2020 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 II FD-455.Ddf pressure, size and anchorage information. Also known as the Verified By: A. Lynn Miller, P.E. 58705 455 Series. Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-455 Evaluation.Ddf Created by Independent Third Party: No 331.3 FD-5555 Vinyl French Door & Sidelite/Transom Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331 R12 C CAC Certification FD 5555.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/21/2020 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 II FD-555.odf pressure, size and anchorage information. Also known as the Verified By: A. Lynn Miller, P.E. 58705 555 Series. Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-555 Evaluation.odf Created by Independent Third Party: No Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department -with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here Product Approval Accepts: 11 Dedit Card Safe File COPY GENERAL NOTES: 1) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO COMPLY WITH THE FLORIDA BUILDING CODE FOR THE DESIGN PRESSURES LISTED. 2) WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2-THICK. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS DEPICTED AS 2X ARE 1-12' THICK OR GREATER. ATTACHMENT METHOD OF WOOD BUCKS SHALL BE DONE BY OTHERS. I 13-1/16' MAX ANCHOR LOCATIONS ?!SPACING 37-3/8" OVERALL MAX. 73-3/8" OVERALL MAX. 36" BUCK MAX. (Z-BAR) It+ 72" BUCK MAX. (Z-BAR) ! SH OR PW i __T 80-1Ill 6" INSERT 20" MAX, OVERALL 27-1/2" MAX. MAX. 0 SEE 80" BUCK // MAX O - -NOTE A (Z-BAR) 12-5/8" v MAX. 14- -- 3 5AX. I MAX.AX. f 6J=8''Hh51NGC�X� 3) SEE TABLE FOR MINIMUM EDGE DISTANCE FROM CENTER OF ANCHOR TO SUBSTRATE EDGE (EXCLUDING FINISH OR STUCCO). 4) SHIM EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE, USING SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 5) ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE FOR SUBSTRATE MATERIAL. DISSIMILAR MATERIALS SHALL BE PROTECTED AS REQUIRED TO PREVENT REACTIONS. ALUMINUM SHALL BE PROTECTED FROM DISSIMILAR MATERIALS AS SPECIFIED IN THE FLORIDA BUILDING CODE. 6) ADHESIVE SEALANT SHALL BE USED BETWEEN SUBSTRATE AND FLANGE OR FIN. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS. 7) MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, 2.7 KSI CONCRETE: AND CONCRETE MASONRY UNITS COMPLYING WITH ASTM C-90. GLAZING COMPLIES WITH ASTM E1300. 8) THE 113 STRESS INCREASE WAS NOT USED IN THIS NOTE A: ANCHOR EVALUATION. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF WOOD SCREWS. ANCHORS ARE REQUIRED 9) IF THE EXACT PRODUCT SIZE IS NOT LISTED IN THE WITHIN 3" OF THE TABLES, ALWAYS ROUND UP TO THE NEXT LARGER VALUE. CENTERLINE OF THE HANDLE AND/OR DEADBOLT. TABLE 1: Anchor Type Substrate Min. Edge Dist. Min. Embedment #12=SleeI,�SM1A Wood (Southern Pine) 9/16" 1.NT Steel Stud Gr 33 318' 045 (18 GA) Aluminum-60§3'T5 3f8„ -":t16F —Steel, A36 3/8— —V8"I" 1/4" Masonry Anchor Concrete 1" 1-3/8" HOIIOW CMU 2-1/2" 1 1.1/4" NOTE: FOR ALL MEIAI .IUHJ i wTi ta. e�rctw emntumtry i anAau ne nun. a i nnc,wa BEYOND INSIDE FACE OF MATERIAL. TAR[ F 2- 37-3/8" OVERALL MAX. I�-- - T 36" BUCK MAX. (Z-BAR) MAX. SH OR PW 9 INSERT ERAL OVVERALL 23-3/4" MAX. MAX. 11 12-1/4" 23-5/8" MAX. _ -- MAX. 0 SEE �— / - NOTE 96" BUCK - O A MAX - - (Z-BAR) 21" MAX. lL 12-5/8" MAX. F_�14-7/8" ' I �_ 3-15116" MAX. MAX. 8'-O- HI SINGLE X,. As-Tested Configurations Max. Nom. Size (in', Configuration Swing Direction Frame Type Sill Type DP (PSF) Certification Number Glass �35X80>� Slrgt (YJ.� .Osi'-swing] �2-0a ox �7ltglr�(bom rj� `1y50t F390_789Y791- 36x96 Single ()) Out -swing Z-bar/Box Medium (bumper) a!- 35 194792 Min. 1/8" Temp.. 72x96 Double OOQ Out -swing Z-bar/Box Medium (bumper) +/- 35 36x96 Single ()q Out/ln-swing Z-bar/Box Low (saddle) +!- 35• 793, 794 Mono. or I.G. 72x96 Double ()10 Outhn-swing Z-bar/Box Low (saddle) +/- 35' •Umited Water (Water Infiltration Tested at 0 pso. 13-1/16" MAX. Iu —�- —� T SH OR PW SH OR PW 80-11/16" 27-1/2"} INSERT INSERT OVERALL MAX. MAX. 0 80" BUCK 03 MAX (Z-BAR) 1 MAX. �� f MAX.--1 3M5AX. 6-8- HI DOUBLE (XX) - 73-3/8" OVERALL MAX- 72" BUCK MAX. (Z-BAR) -{I 1 ! SH OR PW INSERT SH OR PW INSERT 96-11/16" OVERALL MAX. - 96" BUCK MAX 23-5/8" (Z-BAR) J — / 00 _ 12_5/B" 11 MAX. y� I - - I _,J , M MAX. -1 _ T 3-151161, ff MAX. X. 14- MAX.X. 8'-0- HI DOUBLE XX 61. (a rJ `' r .1070 TECHNOLOGY DRIVE 4 L (' NOKOMIS, FL 34275 FLCERT. OFAUTH.'29296 ',��(/,, f•�:��.•. A. Lynn Miller, P.E. r'', P.E. #58705 zsn er Dero: uemrte rerEveaauentaxvoaarAa�vrunm J. ROSOWSKI 19/30111 ALUMINUM 6063-T6 '1 'era NdA1NESA100pbaEAm axr�revruc .- er FnNelau: MOYRCT^RIETARY. NJKW7xW fMTias DIXS/AHMI/1YBEIREO PPIaJ500.CEDN .wrrow srmovr na oo-rassm s+anev vrwnssrara'xrrmTarwex CABANA DOOR INSTALLATION setmarwsr s®a: sro"t on.ry Nrt CD-290 NTS 1 of 3 1093011JR INSTALLATION WITH BOX FRAME EDGE I_ DISTANCE �` OPTIONAL OPTIONAL EDGE - 'S1'm8T E SUBSTRATE OUT -SWING SINGLE HUNG INSERT DISTANCE / SHOWN SHOWN gUg 7 E EMBEDMENT + r .i EMBEDMENT iX WOOD SHIM ' SHIM - / INSTALLATION NOTES: I OPTIONAL OPTIONAL 1) SEE SHEET 1 FOR SPACING OUT -SWING IN -SWING REQUIREMENTS. _5 —�Z_ co)BOX FRAME SHOWN (— SHOWN r� 2) SEE TABLE 1 FOR ANCHORAGE EXTERIOR SHIM JAMB INSTALLATION AND SUBSTRATE REQUIREMENTS. (DIRECTLY TO SUBSTRATE) 3) MAX. SHIM THICKNESS TO BE 1/4". V 4) FOR HARDWARE DETAILS, SEE SUBSTRATE EXTERIOR EXTERIOR SHEET 3. SHIM inn OPTIONAL -•-� --� OPTIONAL FIXED LIGHT FIXED LIGHT Zzx #��' INSERT INSERT OPTIONAL SHOWN SHOWN 1X BOX FRAME OPTIONAL JAMB INSTALLATION FIXED LIGHT BOX FRAME, BOX FRAME OPTIONAL EXTERIOR WOOD fl IN -SWING (USING 1X WOODBUCK) INSERT HEAD INSTALLATION HEAD INSTALLATION SINGLE HUNG �J SHOWN SHOWN (DIRECTLY TO SUBSTRATE) (USING 1X WOODBUCK) INSERT SHOWN OPTIONAL OPTIONAL FIXED LIGHT KICKPLATE o°° OPTIONAL INSERT —1 INSERT oo� SHOWN SHOWN BUG SWELE EP •, i-� `;`,'�•.- ..'r,� (SADDLE ;.r=.•- THRESHOLD ONLY) ",f_ :5 •. - i EXTERIOR EXTERIOR EXTERIOR y 1;}y' • OPTIONAL OPTIONAL OPTIONAL 2" + / SADDLE 1-7l16' BUMPER om..ey: o.d: Nib,bk THRESHOLD BUMPER THRESHOLD JROSOWSKI 09l30/11 Hmrivs rNFr�rmvf PM1�'91rY�ror ALUMINUM6063-TIm auainffsro SHOWN THRESHOLD SHOWN Rewr ey. Om: IbW4a mxsa�ummmm°eT" D0CWWRIETMYSWMRnONOFr N SHOWN `—'--r rowmv"ilcxi�nrc wamsua rf/tlVSUVLFiCT/dibnBES SUBST 1070 TECHNOLOGY DRIVE NOKOMIS, FL 34275 SUBSThT'//SU STRATE ' rmsFLCERT.OFAUTH.:29296 / CABANA DOOR INSTALLATION BOX/Z-BAR FRAME, A. Lynn Miller, P.E. s.+�vmak am°: sneer awv N° air I L— SILL INSTALLATIONS P.E. #56705 CD•290 NTS 1 2 of 1093011JR INSTALLATION WITH Z-BAR FRAME EDGE _ DISTANCE EDGE DISTANCE 77 T SU T E EMBEDMENT EMBEDMENT SHIM l OPTIONAL OPTIONAL L OUT -SWING --`— IN -SWING SHOWN SHOWN a <�] EXTERIOR EXTERIOR 1X WOOD SHIM TART P a- HAROWARP (Al I PRAMP TYPPSI Part # Description 7CDSP Lock Slake Plate 6FLATM Striker Backing Plate 7CDSPD8 Deadboh Strike Plate 78516)5 9842 x .375 Ph. FI. S.S. 4UBLDK Lock Support Assy. 7634FW 06 x .750 Ph. Fl. SMS 7CDSP Lock Strike Plate (Active Slab) 6FLATNI Striker Backing Plate (Attie Slab) 7CDSPDB Deadboll Sidke Plate (Attire Slob) 78516YS g&32 x .375 Ph. FI. S.S. (Acli. Slab) 6COR4MW Rlm Foam Insert -3318' MEAD Deadboft/Knob(Aclhe) 7KNOB0 K-1, Set(Inactfw) 7CDKL0KB Deadbolt/Kmb-Polished Brass(Acthe) 7DBLKB Double lacksel 69333W Hinge 41704 Hinge Pln Cap 41705 Hnge Pin Bmftim 7XQ0M Hl ge Pin M45 Hrgs Rmt 7834FPTW p8 x .750 Ph. FI. 7EK SMS SUBSTRATE SHIM F7AOPTIONAL OUT -SWING SHOWN EXTERIOR ID SUBSTRATE 1X WOOD Z-BAR FRAME JAMB INSTALLATION (DIRECTLY TO SUBSTRATE) OPTIONAL SINGLE HUNG INSERT SHOWN OPTIONAL OPTIONAL FIXED LIGHT FIXED LIGHT � I INSERT INSERT SHOWN SHOWN / ' Z-BAR FRAME, Z-BAR FRAME, OPTIONAL I HEAD INSTALLATION HEAD INSTALLATION SINGLE HUNG (DIRECTLY TO SUBSTRATE) (USING 1X WOODBUCK) INSERT / SHOWN / OR coo dgA*" eo°� EXTERIOR Z-BAR FRAME, OPTIONAL OPTIONAL OPTIONAL 0000°000 aoago OPTIONAL JAMB INSTALLATION FIXED LIGHT IN INSERT FIXED LIGHT i_ KICKPLATE -SWING (USING 1X WOODBUCK) SHOWN SHOWN INSERT SHOWN L INSERT SHOWN o o INSTALLATION NOTES: �,r•.. - '• I EXTERIOR EXTERIOR EXTERIOR_ 1) SEE SHEET 1 FOR SPACING REQUIREMENTS. - -, /, 0�--�--; :-• _ (� - (o 2) SEE TABLE 1 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. , j ••,; _��,c '" `I'f'.:" •� 3) MAX. SHIM THICKNESS TO BE 1/4". OPTIONAL OPTIONAL OPTIONAL 2"-- SADDLE 1-7/16" BUMPER 7mWE R�voawsry r THRESHOLD BUMPER THRESHOLD J. ROSOWSKI 09130/11 fludw Gr ALUMINUM 6063-T6 rmrnvsrKc4aulslaAxwmlrcr7cr SHOWN I THRESHOLD SHOWN A.roaey n.m: ae+.nr ,v° fss SHOWN F�----� —cam—_ txxaHwru4reeusmaeasr'owxaaw amour ihEO6PESIID llitlrrt7! {FPIe4.nproms 0a'arlGra0161i8FS SUBSTi{AT / SUBS15 IV: SU ST T / //` / 1070 TECHNOLOGY DRIVE NOK ,� 'I ! / FLCERTOOFAUTH.MIS ?29296 CABANA DOOR INSTALLATION iii\\\YYYIZ-BAR FRAMES A. Lynn Miller, P.E. s«raebmt ssr: sr,ex LbWVN Ber. SILL INSTALLATIONS P.E. p56705 CD-290 NTS 3 of 3 1093011JR