Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED REVISION, MANUAL J & D, Per Steven
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-18 09:13:05 Right-Suite® Universal 2022 22.0.01 RSU08101 Page 1 ...s\QUICK\Documents\Wrightsoft HVAC\CHIM, JAN.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information JAN CHIMFor:5505 DELEON AVENUE, FT. PIERCE, FL 34951 Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh20251 Structure Btuh19604 Ducts Btuh5022 Ducts Btuh6273Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh25273 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh24583 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh1903 Ducts Btuh1972Central vent (0 cfm) Btuh0 CoolingHeating (none)17081708Area (ft²) Equipment latent load Btuh3875 1366413664Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh28458 Equiv. AVF (cfm) 4687 Req. total capacity at 0.70 SHR ton2.9 Heating Equipment Summary Cooling Equipment Summary Make Make CarrierTrade Trade CARRIER Model Cond 24ACC436A0L300AHRI ref Coil FB4CNP036L AHRI ref 206494630Efficiency 100 EFF Efficiency 12.0 EER, 14 SEER Heating input kW6.9 Sensible cooling Btuh23240Heating output Btuh23458 Latent cooling Btuh9960 Temperature rise °F19 Total cooling Btuh33200Actual air flow cfm1107 Actual air flow cfm1107 Air flow factor cfm/Btuh0.044 Air flow factor cfm/Btuh0.043Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.87 Bold/italic values have been manually overridden 2022-Feb-18 09:13:05 Right-Suite® Universal 2022 22.0.01 RSU08101 Page 1 ...s\QUICK\Documents\Wrightsoft HVAC\CHIM, JAN.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information JAN CHIMFor: 5505 DELEON AVENUE, FT. PIERCE, FL 34951 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.304in/100ft0.304 Actual air flow cfm1107cfm1107 Total effective length (TEL) ft165 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st1115.021.8VlFx0x04.00.3654038924cBATH st1115.023.3VlFx0x06.00.36184811963cBEDROOM st1115.024.1VlFx0x06.00.3591591513721cBEDROOM 2 st1115.024.7VlFx0x06.00.3581861554359cBEDROOM 3 st3135.029.7VlFx0x08.00.3042422405668cENCLOSED PORCH 95.012.0VlFx0x04.00.46727621422hFOYER st2115.020.5VlFx0x06.00.36992952166hLVI/DIN/KIT st3135.022.0VlFx0x08.00.31892952166hLVI/DIN/KIT-A st2115.016.5VlFx0x06.00.38092952166hLVI/DIN/KIT-B st3135.027.8VlFx0x08.00.30792952166hLVI/DIN/KIT-C Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 425 469 0.358 439 14.0 0x0 VinlFlx st3 Peak AVF 430 427 0.304 788 10.0 0x0 VinlFlx st2 st2 Peak AVF 620 611 0.304 789 12.0 0x0 VinlFlx 2022-Feb-18 09:13:05 Right-Suite® Universal 2022 22.0.01 RSU08101 Page 2 ...s\QUICK\Documents\Wrightsoft HVAC\CHIM, JAN.rup Calc = MJ8 Front Door faces: E Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 3970 362 0 0 0 0 x0 0 VlFx rb2 0x 2850 276 0 0 0 0 x0 0 VlFx rb1 0x 1190 124 0 0 0 0 x0 0 VlFx rb4 0x 3060 346 0 0 0 0 x0 0 VlFx