Loading...
HomeMy WebLinkAboutInstruction Page Section C11 a s'` L U C U ? J� �l c �4 o lw 3 I ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System A,!-. Requireo Sections of the P mit Application For Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7- Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCRE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA" , System Manufacturer:` 01 Product Approval No.: FL_ 14 (6 a 2 — J Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':'L� Zone 1A Zone 2:13 Zone 3: )R'/ Max. Design Pressure, from the specific product approval system: Deck: -ell Y ` Type: Gauge Thickness: �o Q 4 Slope: Anchor/Base Sheet & No. df Ply(s): AnchjU/Base Sheet Fastener/Bonding Material: �d Sy �gy Insulation Base Layer: Base Insultation Size and Thickness: Base Insulatiop Fast&tner/Bonding Material: V Top Insulation Le4 yyer\ Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: C ac5X .W f Surfacing: rd N_ k SA aas G-" Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1' ' oc @ Lap, # Rowse ®—" o0 Zone 1:_...." oc @ Lap, # Rows @ " 00 Zone 2 _...." oc @ Lap, # Rows _ ® " 00 Zone 35." oc @ Lap, # Rows_ @ " oo Number of Fasteners Per Insulation Board: Zone 1': Zon 'Zone 2-—Zone 3: Illustrate Compo is oted and Details as Applicable: Woodblockin , Gutte , Edge Termination, Stripping, Flashing, ontinuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16..