HomeMy WebLinkAboutProduct Evaluation ReportBUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
of
398 East Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
American Craftsman Windows
Silver Line Windows and Doors
70 Series / V1 Series / (2127) Single -Hung Windows
(HVHZ)(IMPACT)
for
Florida Product Approval
FL# FL14911
Report No..7263
Current Florida Building Code
Method:
Category:
Sub — Category:
Product:
Material:
Product Dimensions:
RECEIVED
FEB 2 3 2022
St. Lucie County
Permittlnp
FILE CupY
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY BOCC
0/ y/z0/Lz
O x r 0 6 1 l
1— D (Engineering Evaluation)
Windows
Single Hung
70 Series / V1 Series / (2127) Single -Hung
Windows
PVC
See Installation Instructions, SWD050
Prepared for:
Silver Line Windows and Doors
One Silverline Dr.
North Brunswick, NJ 08902
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date:10/14/2020
Contents:
Evaluation Report Pages 1— 4
s
O
N O
.'7 7
_
S A' OF
=�'�`� O IDP:' tv�
i s '• '
Digitally signed by Hermes F Norero
Reason: I am approving this document Hermes F. Norero, P.E.
Date: 2020.10.22 02:28:29 +02'00' Florida P.E. No. 73778
BUILDING DROPS FL#: FL14911
PA\\ /20
A Perfect Solution in Eve Drop! Date: 1No: 726
Every P Report No: 7263
Certificate of Authorization: 29578
Manufacturer: Silver Line Windows and Doors
Product Category: Windows
Product Sub -Category: Single Hung
Compliance Method: State Product Approval Method (1)(d)
Product Name: 70 Series / V1 Series / (2127) Single -Hung Windows
(HVHZ) (IMPACT)
Scope: This is a. Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line
Windows and Doors based on Method 1d of the State of Florida Product Approval, Florida
Department of Business and Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the Current Florida Building
Code.
See Installation Instructions SWD050, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
1. This product has been evaluated and is in compliance with the Current Florida Building Code,
including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the Current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of Installation Instructions SWD050 require
further engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions SWD050 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 2 of 4
1
BUILDING DROPS FL#: FL14911
A Perfect Solution in Every Drop! Date: 10/14/20
Certificate of Authorization: 29578 Report No: 7263
Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a Quality Assurance Entity through
Window and Door Manufacturers Association (FBC Organization #QUA2515).
Performance Standards: The product described herein has been evaluated per:
Referenced Data:
• TAS 201-94
• TAS 202-94
• TAS 203-94
• ASTM E330-02
• ASTM E1886-12
• ASTM E1996-17
• AAMA/WDMA/CSA 101/I.S.2/A440-11
1. Product Testing performed by National Certified Testing Laboratories, Inc.
(FBC Organization # TST1589)
Report:
Dated:
NCTL110-16327-1
08/13/2013
Signed and Sealed by: Harold E. Rupp, FL PE No 15935, Sealed Date 02/06/18
NCTL110-16327-2
11/05/2013
NCTL 110-16327-3
08/13/2013
11524.01-109-47
05/01/2018
11238.01-109-47
03/28/2022
2. Quality Assurance
Window and Door Manufacturers Association
(FBC Organization #: QUA2515)
3. Material Certification
Miami -Dade County Notice of Acceptance
Eastman Chemical Company (Previously Solutia)
Saflex (Vanceva Composites) PVB Interlayer
4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance
with AAMA 303
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 3 of 4
BUILDING DROPS FL#: FL14911
A Perfect Solution in Eve Date: 10/14/20
+° Every Drop! p• Report No: 7263
Certificate of Authorization: 29578
Installation:
Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation
requirements.
Equivalence of Test Standards:
Various test standards have been evaluated for differences in test methodology, if any, between tested
editions of the test standards listed below and those editions referenced in the current Florida Building Code.
Manufacturer has tested their products to the following test standard edition(s):
1) AAMA/WDMA/CSA 101/I.S.2/A440-08
2) ASTM E1886-05
3) ASTM E1996-06/09/12
Chapter 35 of the current Florida Building Code references the following editions of the above mentioned
test standards:
1) AAMA/WDMA/CSA 101/I.S.2/A440-11
2) ASTM E1886-12
3) ASTM E1996-17
After review of the above mentioned referenced standards and editions, it has been found that no significant
technical changes have been made to the test standards that would affect the results. All referenced
standards have been found to be equivalent. All material test results meet minimum requirements of the
current FBC including HVHZ provisions.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 4 of 4