HomeMy WebLinkAboutProduct Approval I REVIEWED FOR -��zv Instructions: FILE COPY Select the appropriate `u�iaa PE CONIP"ANC structure in question. � Determine the design windspeed for the project a location. 21 Use the attachment method indicated for that ' � �,?� windsp+eed within each roof zone. i '2 a 1 l 2 2_ — g NOTE: ASCE 7-16 and FBG 2020 adopt a 7-zone concept. i For the load tables below, the worst case was taken { for each zone and reported using the standard zones 1�,�% t t 1 2 Zone 1 includes zones 1 and 1' l _. - _ - ._ _.._._ i { Zone 2 includes zones 2e, 2r, and 2n .. •- ,�,p� F' caec�tao�� �a}-r Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple xi��«T ��ap`it�€zsc��r° uV_MlrnoWAIHwitW, p toe Tw CR'•c. c».eF 1.�,AIT "Zop'At tkw,lB"W�KIZR scheme, at the expense of some design efficiency. OMXrtP ;EA1DYx�, � R .c ore. Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional. METHOD A: METHOD 6: METHOD 0: METHOD D:. , 9AT16°C7 #iAAT16110C. #1tlATS"bG #1QA '6"C3:C. 17(NOM),-_-- - NR: NOT RATED-'QQN8ULT DESIGN R=. PROFESSIONAL.AS NEEDED-: / J ` Use this load We for structures which meat the fdlowinq criteria; Use this load fable for structures which meet the fallowing criteria: Are located in Exposure 8 area Are located in B,C,or d exposure area Have either a flat roof,or gablelhip roof with max slope of 12:12 Have either a fiat roof,or gablethip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a meats Roof Height of 30 feet or less 01• &aj at!CriMp on ! as d .01: f r" ! Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 1300140 150 1601 170 180 191 110 Zone 1: A A A -. A A A X A A A A Zone 1: A: - A A A A A A Zone 2: A A A ,A A A A ' A Zone 2: A A A A Zone 3 A --A A A A A Zone 3: A : A A. Use this load table for structures which meet the following criteria: L6-e this load table for structures which meet the following criteria' Are located in Exposure B area ire located in B,C,or D exposure are: Have either a flat roof less than 7°,hip,roof with Have either-a flat roof less than 7°,hip roof with max slope of 12:12,or gable roof with slope between 4.4.12&12:12 rnax slope of 12.12,or gable roof with slope between 4.4:12&12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less F07022,01. afta§Y Cri 513 ° ! and F 17Q .01: a 5 rim 15 3 " ! Wind 105 110 120 130 140 150 160 170 180.190 200 Wind 105 110 120 130 140 150 160 170 180 19Q 200 Zone 1: A. A A A A ;j-A A A A A A Zone 1: A A A A A A Zane 2. A A A A; A A_ A A ,.: A t< Zone 2: A A A .fit _A Zanra 3: A A- A A A A A 960 Zone 3: A A A s y- x s =erinQ CBUCK IE=ncjlnL SpL=clalty Struaturdl IEnglnL=L=rinq CBUCK,Inc.Certificate of Authorization#8064 FILE COPY Evaluation Report REVIEWED FOR "Ultra HT Wind & Water SealTMI) S. LUCIE COUNTY BOCC CODE COMPLIANCE Roof Underlayment Manufacturer: Zz v MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval # FL 11842.3 R8 Florida Building Code 7th Edition (2020) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: "Ultra HT Wind &Water SealTM11 Description: Self-Adhered Underlayment' Prepared by: This item has been electronically signed and sealed by James L. Buckner; P.E., SECB James L.Buckner,P.E.,on this date using a Digital Signature. Florida Professional Engineer#31242 Printed copies of this document are not considered signed and sealed, and the signature must be verified on any Florida Evaluation ANE ID: 1916 electronic copies. \\\Illlti�i�,,//, Project Manager: Diana Galloway ES ..: B.. Zr+'� Report No. 20-229-UHT-ER IICENSF'•.tC,p'�' (Revises 17-131-UHT-ER,FLI1841.5 R4) * No 31242 Date: 08/28/20 _ �'• STATE OF •'_�� Contents: %,�s'•cZORIDP.•' C-> Evaluation Report Pages 1—5 T� 2020.09.1713:23:17-04'00' MUCK,Inc.dba CBUCK Engineering Phone:(561)491-9927•Email:cbuck(cDcbuckinc.net•Website:www.cbuckinc.net Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,#M069,Pompano Beach,FL 33062 1 FL#: FL 11842.3 118 Date: 08/28/20 COMM% 2 r=nQin =ring Report No.:20-229-UHT-ER Page 2 of 5 Speclalty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: MFM Building Products Corp. FILE Copy 525 Orange Street Coshocton, Ohio 43812 REVIEWED-FOR (740)622-2645 CODE COMPLIANCE www.mfmbp.com a71. LUCIE COU Product Name: "Ultra HT Wind&Water Seal'"' OCC ©/ P 7 ZZ Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind & Water SealT""" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 7th Edition (2020), Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils(nominal) Substrate(s): "Ultra .HT Wind & Water SealT""" has been evaluated for application to the following substrates (Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind &Water Sea IT""" shall be installed in accordance with the attached installation method and in compliance wi-::h applicable code sections of the FBC 7th Edition (2020), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL#: FL 11842.3 118 Date: 08/28/20 nq CS Report No.:220°-229-UHT-ER Page FILL ROPY Specialty Structural Engtne=rinq I , thorizotion#8064 CODE COMPLIANCE ST. LUCIE COUNTY BOCC Pf //Zz- Performance Standards: The product described herein has demonstrated compliance wit�h�D ��p� • ASTM D 1970-15a — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6+th Edition (2020)for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope:. . This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be.in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Evaluated for use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. Installation shall comply with FBC Section 1507.1.1. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 J to comply with Florida product approval rule (FAC) 61G20-3. This evaluation -report is part of the Florida Building Commission approval for the listed code related,criteria. This report by James Buckner, P.E. and CBUCK Engineering is J FL#: FL 11842.3 R8 Date: 08/28/20 Report No.:20-229-UHT-ER ncillne L=r Page 4 of 5 SPL clalty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FILE C®P REVIEWED FOR CO®E CONIPLIANC C ST. LUCIE COUNTY lBOC i FL#: FL 11842.3 R8 Date: 08/28/20 C ffitm 31116 J1 C I<0. En—Ineering Report No.:20-229-UHT-ER Page 5 of 5 Sp=CldlfilJ StrL.rCturdl Eng9n=�rinq CBUCK,Inc.Certificate of Authorization#8064 MFM Building Products Corp. Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6".Side laps must be a minimum of:;". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50°F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. "Ultra HT Wind & Water Sea IT""' shall be installed in accordance with the, attached installation method and in compliance with applicable code sections of the FBC 7th Edition (2020), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation iFJJLCo PY supplemental guide for attachment. �+�J Product Illustrations REVIEWED FOR CODE C®MPLIANCE l !.`fit BHT ST. LUCIE COUNTY BOCC 4 4- 17 d N -F.. .. +ice sx�'.s"^.F".,,.,,• .N xs��