Loading...
HomeMy WebLinkAboutReview CommentsREVIEW COMMENTS Page 1 PROPERTY INFORMATION Address: 4625 S Indian River Dr Owner(s): RECEIVED Michele Alois / Stephen Ferreira City / State / Zip: Fort Pierce, FI 34982 Parcel #: 2436-331-0001-000/9 JAN 2 6 2031isdiction: SAINT LUCIE COUNTY St, 6uol® 9eenty Zoning: RE-2 Permlttlrlg Lot#: 2 Block: APPLICATION INFORMATION Permit Number: 2110-0576 Stories: Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Douglas J Sammons Business Name: Hall -Sammons Inc Business Addr: 1101 Ne Martin Ave City / State / Zip: Jensen Beach, FI 34957 Automatic Sprinkler System? No Fax Number: Email: Hallsammonsinc@Gmail.0 om; Lisa. Hallsammonsinc@ Gmail.Com REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Heather Burford 10/20/2021 Comment: PAPER FILE 12/8/2021 Comment: VERIFY LEAD AND ASBESTOS REPORT REQUIRED FRONT COUNTER REVIEW COMPLETE Heather Burford Comment: NOTIFIED FOR PICK UP PENDING Comment: PLANNING REVIEW 12/9/2021 Comment: PLANS EXAMINER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 12/8/2021 PENDING HISTORIC REVIEW COMPLETE Peter Swarr 10/22/2021 10/20/2021 10/20/2021 12/8/2021 12/8/2021 INCOMPLETE f �Jpialnc Ancle 12/8I2021 1) 1205.2 COMPLIANCE OPTION. LIFE SAFETY AND PROPERTY CONSERVATION SHALL BE PROVIDED IN ACCORDANCE WITH ONE OF THE FOL-LOWING OPTIONS: 1. PRESCRIPTIVE -BASED PROVISIONS OF THIS CODE. 2. COMPLIANCE ALTERNATIVE -BASED PROVISIONS OF THIS CODE. 3. PERFORMANCE -BASED PROVISIONS OF NFPA 914, CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES, CHAPTER 6, ALONG WITH A STRUCTURAL EVALUATION AS SPECIFIED IN SECTION 1401.4.1 OF THIS CODE. REVIEW COMMENTS @on tlir►►fi>tlan� Page 2 Comment: 2) 1205.3 CONDITIONS SPECIFIC TO COMPLIANCE OPTIONS 2 AND 3. 1. ARCHITECT OR ENGINEER REQUIRED. THE EVALUATION OF HIS-TORIC STRUCTURES UTILIZING COMPLIANCE OPTIONS 2 OR 3 SHALL BE COMPLETED BY A FLORIDA-REGISTERED ARCHITECT OR ENGINEER AND SUBMITTED TO THE BUILDING CODE OFFICIAL FOR REVIEW. 2. DOCUMENTATION. HISTORIC BUILDINGS THAT ARE DETERMINED TO BE CODE COMPLIANT THROUGH, THE USE OF COMPLIANCE OPTION 2 OR 3 SHALL HAVE COPIES OF THE ARCHITECT OR ENGI-NEER'S REPORT KEPT ON SITE AND AVAILABLE FOR REVIEW BY THE BUILDING OFFICIAL. 3. CHANGE OF REPORT ASSUMPTIONS. ANY REMODELING, MOD[-FICATION, RENOVATION, CHANGE OF 12/8/2021 USE OR CHANGE IN THE ESTABLISHED ASSUMPTIONS OF THE REPORT SHALL REQUIRE A REEVALUATION AND REAPPROVAL BY THE BUILDING CODE OFF]-CIAL. 4. CONSTRUCTION SAFEGUARDS. CONSTRUCTION SAFEGUARDS CON-SISTENT WITH CHAPTER 15 AND NFPA 914, CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES, SHALL BE MAINTAINED DURING PERIODS OF REPAIR, ALTERATION., CHANGE OF OCCU-PANCY, ADDITION AND RELOCATION OF HISTORIC BUILDINGS. 5. MAINTENANCE. IN ADDITION TO THE REQUIREMENTS OF SECTION 1204, HISTORIC BUILDINGS SHALL BE MAINTAINED IN ACCOR-DANCE'WITH CHAPTERS 1, 2, 8, 9, 10 AND 11 OF NFPA 914, CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES. Comment: 1206.1 INVESTIGATION AND EVALUATION REPORT. AN HISTORIC BUILDING UNDERGOING ALTERATION OR CHANGE OF OCCUPANCY SHALL BE INVESTIGATED AND EVALUATED. IF IT IS INTENDED THAT THE BUILD- ING MEET THE REQUIREMENTS OF THIS CHAPTER, A WRITTEN REPORT SHALL BE PREPARED AND FILED WITH THE BUILDING OFFICIAL BY A FLORIDA-REGISTERED ARCHITECT OR ENGINEER. SUCH REPORT SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF SECTIONS 4.3.1.2 THROUGH 4.3.2 OF NFPA 9.14, 12/8/2021 CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES AND SHALL IDENTIFY EACH REQUIRED SAFETY FEATURE THAT IS IN COMPLIANCE WITH THIS CHAPTER AND WHERE COMPLIANCE WITH. THIS OR OTHER CHAPTERS WOULD BE DAMAGING TO THE CONTRIBUTING HISTORIC FEATURES. IN ADDITION, THE REPORT SHALL DESCRIBE EACH FEATURE THAT IS NOT IN COMPLIANCE AND DEMONSTRATE HOW THE INTENT OF THE PROVISIONS OF THIS OR OTHER CHAPTERS ARE COMPLIED WITH IN PROVIDING AN EQUIVALENT LEVEL OF SAFETY. Comment: 3) DOCUMENTS NEEDED: 12/8/2021 PROVIDE A COPY OF THE ASBESTOS REPORT. PROVIDE A DEMOLITION PLAN Comment: SHEET A0.2 - INCORRECT BUILDING CODE 12/8/2021 - BASIC VELOCITY IS BLANK -VERIFY 15' HEIGHT, THIS IS AN ELEVATED TWO STORY STRUCTURE. - MORE DETAILS NEEDED FOR FRAMING, HEADER/LINTEL SIZE & ATTACHMENT Comment: S2.1 12/8/2021 - GENERAL COMMENT- PLANS & NOTES ARE CUT OFF - KEYNOTE 3, NEED DETAIL FOR BEAM REPAIR - VERIFY IF A NEW BATHROOM IS BEING ADDED TO THE GARAGE. 12/8/2021 Comment: SHEET S2.2 - NEW STAIRS DO NOT MEET CODE. TOO MANY ERRORS, REVISE & RESUBMIT. 12/9/2021 Comment: **WILL SEND TO PLANNING FOR HISTORIC REVIEW** 1/5/2022 Comment:—1/5/21- EMAIL COORD. W/ARCHITECT ON STAIR."