HomeMy WebLinkAboutReview CommentsREVIEW COMMENTS
Page 1
PROPERTY INFORMATION
Address: 4625 S Indian River Dr Owner(s):
RECEIVED Michele Alois / Stephen Ferreira
City / State / Zip: Fort Pierce, FI 34982
Parcel #: 2436-331-0001-000/9 JAN 2 6 2031isdiction: SAINT LUCIE COUNTY
St, 6uol® 9eenty
Zoning: RE-2 Permlttlrlg Lot#: 2 Block:
APPLICATION INFORMATION
Permit Number: 2110-0576 Stories:
Permit Type: BUILDING RESIDENTIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name: Douglas J Sammons
Business Name: Hall -Sammons Inc
Business Addr: 1101 Ne Martin Ave
City / State / Zip: Jensen Beach, FI 34957
Automatic Sprinkler System? No
Fax Number:
Email: Hallsammonsinc@Gmail.0
om; Lisa. Hallsammonsinc@
Gmail.Com
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING PENDING Heather Burford
10/20/2021 Comment: PAPER FILE
12/8/2021 Comment: VERIFY LEAD AND ASBESTOS REPORT REQUIRED
FRONT COUNTER REVIEW COMPLETE Heather Burford
Comment:
NOTIFIED FOR PICK UP PENDING
Comment:
PLANNING REVIEW
12/9/2021 Comment:
PLANS EXAMINER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
12/8/2021
PENDING
HISTORIC REVIEW
COMPLETE Peter Swarr 10/22/2021
10/20/2021 10/20/2021
12/8/2021 12/8/2021
INCOMPLETE f �Jpialnc Ancle 12/8I2021
1) 1205.2 COMPLIANCE OPTION. LIFE SAFETY AND PROPERTY CONSERVATION SHALL BE PROVIDED IN
ACCORDANCE WITH ONE OF THE FOL-LOWING OPTIONS:
1. PRESCRIPTIVE -BASED PROVISIONS OF THIS CODE.
2. COMPLIANCE ALTERNATIVE -BASED PROVISIONS OF THIS CODE.
3. PERFORMANCE -BASED PROVISIONS OF NFPA 914, CODE FOR FIRE PROTECTION OF HISTORIC
STRUCTURES, CHAPTER 6, ALONG WITH A STRUCTURAL EVALUATION AS SPECIFIED IN SECTION 1401.4.1
OF THIS CODE.
REVIEW COMMENTS
@on tlir►►fi>tlan�
Page 2
Comment: 2) 1205.3 CONDITIONS SPECIFIC TO COMPLIANCE OPTIONS 2 AND 3.
1. ARCHITECT OR ENGINEER REQUIRED. THE EVALUATION OF HIS-TORIC STRUCTURES UTILIZING
COMPLIANCE OPTIONS 2 OR 3 SHALL BE COMPLETED BY A FLORIDA-REGISTERED ARCHITECT OR
ENGINEER AND SUBMITTED TO THE BUILDING CODE OFFICIAL FOR REVIEW.
2. DOCUMENTATION. HISTORIC BUILDINGS THAT ARE DETERMINED TO BE CODE COMPLIANT THROUGH,
THE USE OF COMPLIANCE OPTION 2 OR 3 SHALL HAVE COPIES OF THE ARCHITECT OR ENGI-NEER'S
REPORT KEPT ON SITE AND AVAILABLE FOR REVIEW BY THE BUILDING OFFICIAL.
3. CHANGE OF REPORT ASSUMPTIONS. ANY REMODELING, MOD[-FICATION, RENOVATION, CHANGE OF
12/8/2021 USE OR CHANGE IN THE ESTABLISHED ASSUMPTIONS OF THE REPORT SHALL REQUIRE A REEVALUATION
AND REAPPROVAL BY THE BUILDING CODE OFF]-CIAL.
4. CONSTRUCTION SAFEGUARDS. CONSTRUCTION SAFEGUARDS CON-SISTENT WITH CHAPTER 15 AND
NFPA 914, CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES, SHALL BE MAINTAINED DURING
PERIODS OF REPAIR, ALTERATION., CHANGE OF OCCU-PANCY, ADDITION AND RELOCATION OF HISTORIC
BUILDINGS.
5. MAINTENANCE. IN ADDITION TO THE REQUIREMENTS OF SECTION 1204, HISTORIC BUILDINGS SHALL BE
MAINTAINED IN ACCOR-DANCE'WITH CHAPTERS 1, 2, 8, 9, 10 AND 11 OF NFPA 914, CODE FOR FIRE
PROTECTION OF HISTORIC STRUCTURES.
Comment: 1206.1 INVESTIGATION AND EVALUATION REPORT. AN HISTORIC BUILDING UNDERGOING ALTERATION OR
CHANGE OF OCCUPANCY SHALL BE INVESTIGATED AND EVALUATED. IF IT IS INTENDED THAT THE BUILD-
ING MEET THE REQUIREMENTS OF THIS CHAPTER, A WRITTEN REPORT SHALL BE PREPARED AND FILED
WITH THE BUILDING OFFICIAL BY A FLORIDA-REGISTERED ARCHITECT OR ENGINEER. SUCH REPORT
SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF SECTIONS 4.3.1.2 THROUGH 4.3.2 OF NFPA 9.14,
12/8/2021 CODE FOR FIRE PROTECTION OF HISTORIC STRUCTURES AND SHALL IDENTIFY EACH REQUIRED SAFETY
FEATURE THAT IS IN COMPLIANCE WITH THIS CHAPTER AND WHERE COMPLIANCE WITH. THIS OR OTHER
CHAPTERS WOULD BE DAMAGING TO THE CONTRIBUTING HISTORIC FEATURES. IN ADDITION, THE
REPORT SHALL DESCRIBE EACH FEATURE THAT IS NOT IN COMPLIANCE AND DEMONSTRATE HOW THE
INTENT OF THE PROVISIONS OF THIS OR OTHER CHAPTERS ARE COMPLIED WITH IN PROVIDING AN
EQUIVALENT LEVEL OF SAFETY.
Comment: 3) DOCUMENTS NEEDED:
12/8/2021 PROVIDE A COPY OF THE ASBESTOS REPORT.
PROVIDE A DEMOLITION PLAN
Comment: SHEET A0.2
- INCORRECT BUILDING CODE
12/8/2021 - BASIC VELOCITY IS BLANK
-VERIFY 15' HEIGHT, THIS IS AN ELEVATED TWO STORY STRUCTURE.
- MORE DETAILS NEEDED FOR FRAMING, HEADER/LINTEL SIZE & ATTACHMENT
Comment: S2.1
12/8/2021 - GENERAL COMMENT- PLANS & NOTES ARE CUT OFF
- KEYNOTE 3, NEED DETAIL FOR BEAM REPAIR
- VERIFY IF A NEW BATHROOM IS BEING ADDED TO THE GARAGE.
12/8/2021 Comment: SHEET S2.2
- NEW STAIRS DO NOT MEET CODE. TOO MANY ERRORS, REVISE & RESUBMIT.
12/9/2021 Comment: **WILL SEND TO PLANNING FOR HISTORIC REVIEW**
1/5/2022 Comment:—1/5/21- EMAIL COORD. W/ARCHITECT ON STAIR."