HomeMy WebLinkAboutRevisions OFFICE USE ONLY:
DATE FILED: PERMIT# 2105-0779
REVISION FEE: RECEIPT#
PLANNING &DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE,FL 34982-5652
(772)462-1553 FILE p
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
4801 SUNSET BLVD,FORT PIERCE,FL 34982
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED ENERGY CALCS,MANUAL J,DUCK DRAWING-DUE TO KNEE WALL MISSING ON ORGINALS
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CBC 1263072 ST. LUCIE CO CERT.#: 31220
BUSINESS NAME: PORT ST LUCIE PROPERTIES,INC.
QUALIFIERS NAME: MARK MONTALTO
ADDRESS: 201 SW PSL BLVD SUITE 103
CITY: PORT ST LUCIE STATE: FL ZIP: 34984
PHONE(DAYTIME): 772-336-0050 FAX:
OWNER/BUILDER INFORMATION:
NAME: MARK MONTALTO
ADDRESS:201 SW PSL BLVD SUITE 103
CITY: PORT ST LUCIE STATE: FL ZIP: 34984
PHONE(DAYTIME: 772-336-0050 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: PAUL WELCH JR
ADDRESS: 1984 SW BITMORE ST
CITY: PORT ST LUCIE STATE: FL ZIP: 34984
PHONE(DAYTIME): 772-785-9888 FAX:
SLCCC: 9123109
Revised 06130/17
1
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance)Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the residential
Simulated Performance method shall include: .
❑ This Checklist
❑ Form R405-2020 report FILE COPY
❑ Input summary checklist that can be used for field verification(usually four pages/may be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements(five pages)
_R E v
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table 402.4.1.1-one page)
❑ A completed 2020 Envelope Leakage Test Report(usually one page);exception in R402.4 allows dwelling units
of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5
❑ If FORM R405 duct leakage type indicates anything other than "default leakage" then a completed 2020 Duct
Leakage Test Report-Performance Method(usually one page).
2022-Feb-28 12:01:04
lA(f1�fltSOft�' Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 1
5uaar{.y.+t�;. 4ttr• ...s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Cale=MJ8 Front Door faces: N
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Spec Home Builder Name: PSL Prop
Street: 4801 Sunset Blvd Permit Office:
City,State,Zip: Fort Pierce,FL 34982 Permit Number:
Owner: Spec Home Jurisdiction: St.Lucie
Design Location: FL,St Lucie Co Intl County: St.Lucie(Florida Climate Zone 2)
1.New construction or existing New(From Plans) 9. Wall types (1580 ft2) Insulation(R) Area(W)
2.Single family or multiple family Single-Family a. Frm Wall,1/2"Gyp Bd Ext,R-11 11.0 191.90
b. Blk Wall,Stucco Ext,R-4.1 Ext 4.1 1364.85
3.Number of units,if multiple family 1 c. Knee Wall,Stucco,R-30, 1/2"G 30.0 22.75
4.Number of bedrooms 3 d. N/A
10. Ceiling types (1602 ftZ) Insulation(R) Area(ftz)
5.Is this a worst case? Yes a. Attic,Shngls,R-30 Roof Ins,1/ 30.0 1601.75
6. Conditioned floor area above grade (W) 1601.75 b. N/A
Conditioned floor area below grade(ftz) 0 c. N/A
7. Windows (179 ft2) Description Area(ft2) 11.Ducts R Area(ft2)
a
Sup:House Attic,Ret:House Attic,AH:House 6.0 318.54
a.U-Factor: Dbl Impact,0.580 45.21 b,
SHGC: 0.24
b.U-Factor: Dbl Impact,0.650 48.00 12.Cooling systems kBtu/hr Efficiency
SHGC: 0.21 a.Split air conditioner 29.0 SEER:16.0
c.U-Factor: Dbl Impact,0.620 37.99, b•
SHGC: 0.22 13.Heating systems kBtu/hr Efficiency
d.U-Factor: Dbl Impact,0.650 48.00 a.Electric strip 23.5 AFUE:100.0
SHGC: 0.24 b.
Area Weighted Average Overhang Depth: 6.205 ft 14.Hot water systems
Area Weighted Average SHGC: 0.228 a.Electric conventional(50 gal) Cap:50 gal
LIEF:0.91
8. Floor types(1601.75 ft2) Insulation(R) Area(ft2) b.Conservation features
a. On Grade Depth,Tile Flr Fnsh 0.0 1601.75 (None)
b. N/A
c. N/A 15.Credits Pstat
Glass/Floor area: 0.112 Total Proposed Modified Loads: 45.97 PASS
Total Baseline Loads: 49.00
I hereby certify that the plans and specifications covered by Review of the plans and specifications :-
this calculation are in compliance with the Florida Energy covered by this calculation indicates
compliance with the Florida Energy
Code. Code. Before construction is completed,
Prepared By Chris Bateman this building will be inspected for
compliance with Section 553.908
�SignatureC fd;t +� Date2/2$/2022 Florida Statutes. t9 ,
R: C,•
I hereby certify that this building,as designed, is in
compliance with t=Florergy C Owner/Agen C7 Building Official Name
Signat_ Date 2Z__ Signature Date
-Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2).
2022-Feb-28 12:01:04
1Afr79f11:51Q 't Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Paget
...s\Wdghtsoft HVAC44801 Sunset Blvd PSL Prop.rup Calc=MJ8 •Front Door faces: N
i
FORM R405-2020
Building Input Summary Report
PROJECT
Title: Sppe�c Home Bedrooms: 3 Address type: Street address
Building Type: FLAsBuilt Bathrooms: 2 Lot#:
Owner: Spec Home Conditioned Area: 1602 Block/Subdivision:
#of Units: 1 Total Stories: 1 Platbook:
Builder Name: PSL Prop Worst Case: Yes Street: 4801 Sunset Blvd
Permit Office: Rotate An le: 0 County: St. Lucie
Jurisdiction: St. Lucie Cross Ventilation: No City, State,Zip: Fort Pierce, FL 34982
Family Type: Single-Famil Whole House Fan: No
New/ New(From Plans) Terrain: Ocean/Lake
Year Construct: Shielding: Suburban
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,St Lucie Co Intl FL_Fort_Pierce 2 41 90 70 75 486 57 Low
BLOCKS
# Name Area Volume
1 House 1601.75 ft2 13784.20 ft'
SPACES
# Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 M Hall 26.00 ft2 208.b0 ft' No 0 0 1 Yes Yes Yes
2 Laundry 68.25 ft2 546.00 W No 0 0 1 Yes Yes Yes
3 Master Bath 90.00 ft2 720.00 ft' No 0 0 1 Yes Yes Yes
4 WIC 63.25 ft2 506.00 fN No 0 0 1 Yes Yes Yes
5 Master Bed 246.50 ft2 2095.25 ft' No 0 1 1 Yes Yes Yes
6 Pantry 15.00 ft2 120.00 ft' No 0 0 1 Yes Yes Yes
7 Kitchen/Nook 274.50 ft2 2552.85 ft' Yes 2 0 1 Yes Yes Yes
8 Great Room 377.00 ft2 3506.10 ft' No 2 0 1 Yes Yes Yes
9 Bed 3 172.50 ft2 1380.00 ft' No 0 1 1 Yes Yes Yes
10 Hall 29.75 ft2 238.00 ft' No 0 0 1 Yes Yes Yes
11 Lin 7.50 fe 60.00 ft' No 0 0 1 Yes Yes Yes
12 Bath 49.50 fe 396.00 ft' No 0 0 1 Yes Yes Yes
13 Bed 2 182.00 ft2 1456.00 W No 0 1 1 Yes Yes Yes
FLOORS (Total Exposed Area=1602 sq.ft.)
J # Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Carpet
1 On Grade.Depth,Tile Fir Fnsh M Hall 4 ft 0 26.00 ft2 0.989 1.0 0 0
2 On Grade Depth,Tile Flr Fnsh Laundry 11 ft 0 68.25 ft2 0.989 1.0 0 0
3 On Grade Depth,Tile Fir Fnsh Master Bath 22 ft 0 90.00 ft2 0.989 1.0 0 0
4 On Grade Depth,Tile Flr Fnsh WIC 17 ft 0 63.25 ft2 0.989 1.0 0 0
5 On Grade Depth,Tile Fir Fnsh Master Bed 15 ft 0 246.50 ft2 0.989 1.0 0 0
6 On Grade Depth,Trle Flr Fnsh Pantry 0 ft 0 15.00 ft2 0.989 1.0 0 0
7 On Grade Depth,Tile Fir Fnsh Kitchen/Nook 24 ft 0 274.50 fe 0.989 1.0 0 0
8 On Grade Depth,Tile Fir Fnsh Great Room 29 ft 0 377.00 ft2 0.989 1.0 0 0
9 On Grade Depth,Tile Fir Fnsh Bed 3 27 ft 0 172.50 ft2 0.989 1.0 0 0
10 On Grade Depth,Tile Fir Fnsh Hall 0 ft 0 29.75 ft2 0.989 1.0 0 0
11 On Grade Depth,Tile Fir Fnsh Lin 0 ft 0 7.50 ft2 0.989 1.0 0 0
12 On Grade Depth,Tile Fir Fnsh Bath 6 ft 0 49.50 ft2 0.989 1.0 0 0
13 On Grade Depth,Tile Flr Fnsh Bed 2 36 ft 0 182.00 ft2 0.989 1.0 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip RoofAsph 1791 ft2 Medium N 0.75 No 0.90 No 0 27
2 Hip RoofAsph 470 ft2 Medium N 0.75 No 0.90 No 0 27
ATTIC
# Type Ventilation Vent Ratio 1 in Area RBS IRCC
1 Full attic Vented 150 1601.75ft2 N N
2 Full attic Vented 150 420.25 W N N
2022-Feb-28 12:01:04
WrlghtSoft° Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 3
�e txis. ..a"-if s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
CEILING (Total Exposed Area= 1602 sq.ft.)
# Ceiling Tye Space R-Value U-Factor Area Framing Fraction Truss Type
1 Attic,Shngls,R-30 Roof Ins,1/2"G M Hall 30 0.034 26.00 ft2 0.10 Wood
2 Attic,Shngls,R-30 Roof Ins,1/2"G Laundry 30 0.034 68.25 ftz 0.10 Wood
3 Attic,Shngls,R-30 Roof Ins,1/2"G Master Bath 30 0.034 90.00 ft2 0.10 Wood
4 Attic,Shngls,R-30 Roof Ins,1/2"G WIC 30 0.034 63.25 ft2 0.10 Wood
5 Attic,Shngls,R-30 Roof Ins,1/2"G Master Bed 30 0.034 246.50 ft2 0.10 Wood
6 Attic,Shngls,R-30 Roof Ins,1/2"G Pantry 30 0.034 15.00 ft2 0.10 Wood
7 Attic,Shngls,R-30 Roof Ins,1/2"G Kitchen/Nook 30 0.034 274.50 ft2 0.10 Wood
8 Attic,Shngls,R-30 Roof Ins,1/2"G Great Room 30 0.034 377.00 ft2 0.10 Wood
9 Attic,Shngls,R-30 Roof Ins,1/2"G Bed 3 30 0.034 172.50 ft2 0.10 Wood
10 Attic,Shngls,R-30 Roof Ins,1/2"G Hall 30 0.034 29.75 ft2 0.10 Wood
11 Attic,Shngls,R-30 Roof Ins,1/2"G Lin 30 0.034 7.50 ft2 0.10 Wood
12 Attic,Shngls,R-30 Roof Ins,1/2"G Bath 30 0.034 49.50 ft2 0.10 Wood
13 Attic,Shngls,R-30 Roof Ins,1/2"G Bed 2 30 0.034 182.00 ft2 0.10 Wood
WALLS (Total Exposed Area=1580 sq.ft.)
Adjacent Cavity Width Height Sheathing U- Frm. Solar Below
r # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade%
1 - Partition Frm Wall,1/2"Gy M Hall 11 4 0 8 0 32.0 ft' 0 0.101 0.25 0.75 0
2 - Partition Frm Wall,1/2"Gy Laundry 11 10 6 8 0 84.0 ft2 0 0.101 0.25 0.75 0
3 E Exterior Blk Wall,Stucco Master Bath 0 2 0 8 0 16.0 ft2 4 0.109 0.22 0.20 0
4 S Exterior Blk Wall Stucco Master Bath 0 12 0 8 0 96.0 f? 4 0.109 0.22 0.20 0
5 W Exterior Bik Wall,,Stucco Master Bath 0 1 6 8 0 12.0 ft2 4 0.109 0.22 0.20 0
6 - Partition Frm Wall,1/2"Gy Master Bath 11 6 0 8 0 48.0 ft2 0 0.101 0.25 0.75 0
7 E Exterior Blk Wall,Stucco WIC 0 5 6 8 0 44.0 ft2 4 0.109 0.22 0.20 0
8 S Exterior Blk Wall,Stucco WIC 0 11 6 8 0 92.0 ft2 4 0.109 0.22 0.20 0
9 E Exterior Blk Wall,Stucco Master Bed 0 14 6 8 6 123.3 ft2 4 0.109 0.22 0.20 0
10 E Exterior Blk Wall,Stucco Kitchen/Nook 0 23 6 9 4 218.6 ft2 4 0.109 0.22 0.20 0
11 W Exterior Blk Wall,Stucco Great Room 0 23 7 9 4 219.1 ft2 4 0.109 0.22 0.20 0
12 W Exterior Knee Wall,Stucco Great Room 30 2 5 9 4 22.8 ft2 0 0.071 0.25 0.20 0
13 - Partition Frm Wall,1/2"Gy Great Room 11 3 0 9 4 27.9 f? 0 0.101 0.25 0.75 0
14 N Exterior Blk Wall,Stucco Bed 3 0 12 0 8 0 96.0 ft2 4 0.109 0.22 0.20 0
15 E Exterior Blk Wall,Stucco Bed 3 0 15 0 8 0 120.0 ft2 4 0.109 0.22 0.20 0
16 N Exterior Blk Wall,Stucco Bath 0 5 6 8 0 44.0 f? 4 0.109 0.22 0.20 0
17 N Exterior Blk Wall,Stucco Bed 2 0 16 0 8 0 128.0 f? 4 0.109 0.22 0.20 0
18 S Exterior Blk Wall,Stucco Bed 2 0 7 0 8 0 56.0 f? 4 0.109 0.22 0.20 0
19 W Exterior Blk Wall,Stucco Bed 2 0 12 6 8 0 100.0 ft2 4 0.109 0.22 0.20 0
WINDOWS (Total Exposed Area=179 sq.ft.)
Wall Overhang Interior
V # Ornt ID Frame Panes NFRC U-Factor SHGC Impact W x H,Area Depth Separation Shade Screening
1 S 4 Metal Low-E Double Yes 0.580 0.24 Yes 27'x 2'1",5 ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor
2 E 9 Metal Low-E Double Yes 0.580 0.24 Yes 3'0"x 52",16 ft' 1 ft 0 in 1 ft 0 in Blinds 45' outdoor
3 E 10 Metal Low-E Double Yes 0.650 0.21 Yes 6'0"x 8'0",48 f? 10 ft 0 in 1 ft 0 in None None
4 W 11 Metal Low-E Double Yes 0.620 0.22 Yes 4'4"x 5'2",22 ft' 6 ft 0 in 1 ft 0 in Blinds 45' outdoor
5 W 11 Metal Low-E Double Yes 0.650 0.24 Yes 6'0"x 8'0",48 ft2 9 ft 1 in 1 ft 0 in None None
6 E 15 Metal Low-E Double Yes 0.580 0.24 Yes 3'0"x 57',16 ft' 1 ft 0 in 1 ft 0 in Blinds 45' outdoor
7 N 16 Metal Low-E Double Yes 0.580 0.24 Yes 3'0"x 32",10 ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor
z I ft 0 1 ft 0 On Blinds 45' outdoor
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 0
INFILTRATION
# Scope Method SLA " CFM 50 ELA E LA ACH ACH 50
1 Wholehouse Simplified 0.000384 1608 88.46 166.1 0.53 7.00
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric strip AFUE:100.0 23.5 kBtu/hr 1 s s#1
COOLING SYSTEM
f # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
-
1 Split air conditioner SEER:16.0 29.0 kBtu/hr 967 cfm 0.70 1 s s#1
HOT WATER SYSTEM
V. # System Type Subtype Location EF Cap Use SetPnt Conservation
1 Electric conventional 0.91 UEF 50 gal 60 gal 120 T None
2022-Feb-28 12:01:04
1IVr7ght: ;G t° Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page
...s\Wdghlsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
I_
FORM R4nr)-2n2O
DUCTS
------- Supply ------ ------ Return---- Air CFM 25 Percent HVAC#
r # Location R-Value Area Location Area Leakage Type Handler Out Leakage QN RLF Heat Cool
1 House Attic 6.0 319 ft2 House Attic 18 ft2 Default Leakage House (Default) 6.00 0.08 1 1
TEMPERATURES
Programmable Thermostat: Y Ceiling Fans:
Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec
Heating [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec
Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec
Thermostat Schedule: Florida Building Code,7th Edition Hours
Schedule Type 202 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75
PM 75 75 75 75 75 75 75 75 75 75 75 75
Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75
PM 75 75 75 75 75 75 75 75 75 75 75 75
Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72
PM 72 72 72 72 72 72 72 72 72 72 72 72
Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72
PM 72 72 72 72 72 72 72 72 72 72 72 72
2022-Feb-2812:01:04
`:wrights®fV. Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 5
ydlara,rA.aa�..gsa.ci..f ...s\Wrightsoft HVAC14801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX= 94
The lower the EnergyPerformance Index, the more efficient the home.
1. New home or addition 1. New(From Plans) 12. Ducts, location& insulation level
a. Supply ducts: R 6.0
2. Single-family or multiple-family 2. Single-Family b. Return ducts: R 6.0
c.AHU location: House
3. Number of units, if multiple-family 3. 1
13. Cooling systems Capacity 29.0
4. Number of bedrooms 4. 3 a. Split system: SEER 16.00
b. Single package: SEER
5. Is this a worst case?(yes/no) 5. Yes c. Ground/water source: SEER/COP
d. Room unit/PTAC: EER
6. Conditioned floor area(ft� 6. 1601.75 e. Other:
7.Windows,type and area" 14. Heating systems Capacity 23.5
a. U-Factor: Db7krnpact(Avg), 0.626 a. Split system heat pump: HSPF
b. Solar Heat Gain Coefficient(SHGC): 7b. 0.23 b. Single package heat pump: HSPF
c.Area(ft� 7c. 179 c. Electric resistance: COP 100.00
d. Gas furnace, natural gas: AFUE
8. Skylights e. Gas furnace, LPG: AFUE
a. U-Factor: 8a. f. Other:
b. Solar Heat Gain Coefficient(SHGC): 8b.
15.Water heating systems
9. Floor type, insulation level a. Electric resistance: 0.91 UEF
a. Slab-on-grade(R-value): 9a. 0.0 b. Gas fired, natrual gas:
b.Wood, raised (R-value): 9b. c. Gas fired, LPG:
c. Concrete, raised (R-value) 9C. d. Solar system with tank:
e. Dedicated heat pump with tank:
10 Wall type and insulation: f. Heat recovery unit: HeatRec%
a. Exterior: g. Other:
1.Wood frame(Insulation R-value): 10a1. 30
2. Masonry(Insulation R-value): 10a2. 4 16. HVAC credits claimed (Performance Method)
b.Adjacent: a. Ceiling fans:
1.Wood frame(Insulation R-value): 10b1. 11 b. Cross ventilation:
2. Masonry(Insulation R-value): 10b2. c.Whole house fan:
d. Multizone cooling credit:
11. Ceiling type and insulation level e. Multizone heating credit:
a. Under attic(R-value): 11 a. 30.0 f. Programmable thermostat: Yes
b. Single assembly(R-value): 11 b.
c. Knee walls/skylight walls(R-value) 11 C.
d. Radiant barrier installed 11 d.
*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features
which will be installed (or exceeded) in this home be re final i pection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featur
Builder Signature: Date: Z 7i
Address of New Home: 4801 Sunset Blvd City/FL Zip: Fort Pierce, FL 34982
04
*WrightSo� Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy® Florida 2020 Section R405.4.1 Compliant Software Feb-281 Pa 9.e 6
wiA•a..t+y.w�,'gm+au, ...s\Wdghtsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 4801 Sunset Blvd PERMIT*
Fort Pierce, FL 34982
MANDATORY REQUIREMENTS -See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOP
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
El R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
w ith the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended
weatherstripping or other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond
intended infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems;if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where
using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the
fireplace. Where using tight-Pigging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
2022-Feb-28 12:01:04
Wright-soft- Right-Su ite®Universal202121.0.11 RSU29066 Rig ht-Energy®Florid a2020 Section R405.4.1 Compliant Software Page
...s\Wdghtsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
I
FORM R405-2020
MANDATORY REQUIREMENTS -(Continued)
R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1.Direct vent apliances with both intake and exhaust pipes installed continuous to the outside.
2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
El R403.1 Controls
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
El R403.3.2.1 Sealed air handler.Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design air flow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the
entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing is required
for Section R405 compliance where credit is taken for leakage,and a duct air leakage Qn to the outside of less
than 0.080(where Qn=duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)
is indicated in the compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(4VC)
or below 55°F(13°C)shall be Insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe
shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
2022-Feb-28 12:01:04
II AghtSQft* Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page
�efri;is .t.;ym ...s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Cale=MJ8 Front Door faces: N
'I
FORM R405-2020
MANDATORY REQUIREMENTS -(Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat
traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 112 inches(89 mm)in the hot water distribution line and cold water line located as close as
possible to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1 Storage water heater temperature controls.
El R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment
installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the
appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water heating system.Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida
Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including:
Natural,Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the
ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by
an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical
ventilation shall meet the following criteria:
1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3.If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that
affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM
CFM CFM/WATT CFM
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom, utility room 10 1.4 cfm/watt <90
Bathroom, utility room 90 2.8 cfm/watt Any
For SI: 1 cfm-28.3 Umin. (a)When tested in accordance HVI Standard 916
2022-Feb-28 12:01:04
wrightSQf '! Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy® Florida 2020 Section R405.4.1 Compliant Software Page 9
w xis: us y r ...s\Wdghtsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
MANDATORY REQUIREMENTS -(Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains If the return duct(s)is installed in an unconditioned space.
Exceptions:
1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is
less than the calculated total sensible load but not less than 80 percent of that load.
2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the
capacity of equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1
El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions.Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2.A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control thatw ill allow shutoff when the outdoor temperature is above 40°F(4.8°C).
R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turnoff and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1.Where public health standards require 24-hour pump operations.
2.Pumps that operate solar-and waste-heat-recovery pool heating systems.
3.Where pumps are powered exclusively from on-site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
2022-Feb-28 12:01:04
UN17ght3dft' Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 10
s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
MANDATORY REQUIREMENTS-(Continued)
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements ofAPSP-14.
R403.13 Dehumidifiers(Mandatory) If installed,a dehumidifier shall conform to the following requirements:
1.The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2.The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3.Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4.Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
rl R403.13.1 Ducted dehumidifiers Ducted dehumidifiers shall,in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1.If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system,a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2.If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3.A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4.Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
Exception: Low-voltage lighting.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
2022-Feb-28 12:01:04
Right-Suite®Universal2021 21.0.11 RSU29066 Right-Energy® Florida 2020 Section R405.4.1 Compliant Software Page 11
...s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Sppec Home Builder Name PSL Prop
Street: 4801 Sunset Blvd Permit Office:
City,State,Zip: Fort Pierce,FL 34982 Permit Number:
Owner: Sppec Home Jurisdiction: St.Lucie
Design Location: FL,St Lucie Co Intl
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the pp
U building envelope.The exterior thermal envelope Air-permeable
mable in El
shall not be used as a
requirements q contains a continuous barrier.Breaks or joints in the 9
air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit
shall be aligned with the insulation and any shall be aligned with the air barrier.
gaps in the air barrier shall be sealed. ❑
Access openings,drop down stairs or knee wall doors
to unconditioned attics paces shall be sealed.
Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls
shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity
and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 El
walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier
Windows,skylights The space between window/door jambs and framing,
and doors and skylights and framing shall be sealed. ❑
Rim joists are insulated and include an air Rim joists shall be insulated. ❑
Rim joists barrier.
Floors(including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed
above-garage and edge of insulation. to maintain permanent contact with the underside
cantilevered floors) of subfloor decking,or floor framing cavity
insulation shall be permitted to be in contact ❑
with the top sideof sheathing,or continuous
insulation installed on the underside of floor
framing and extends from the bottom to the top of
all perimeter floor framing members.
Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation,
walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑
overlapping joints taped. to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shaft
openings to exterior or unconditioned space shall ❑
be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or
narrow cavities shall be filled by insulation that ❑
on installation readily conforms to the available
cavity spaces.
Garage Air sealing shall be provided between the garage
separation and conditioned spaces. ❑
Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the
lighting thermal envelope shall be sealed to the finished surface. building thermal envelope shall be air tight ❑
and IC rated.
Plumbing and Batt insulation shall be cut neatly to fit around
wiring wiring and plumbing in exterior walls,or
insulation that on installation readily conforms ❑
to available space shall extend behind piping
and wiring.
Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs
exterior wall electrical or communication boxes or air-sealed shall be insulated. ❑
boxes shall be installed.
Electrical/phone The air barrier shall be installed behind ❑
box on exterior electrical or communication boxes or air-sealed
walls boxes shall be installed.
HVAC register HVAC supply and return register boots that penetrate
boots building thermal envelope shall be sealed to the ❑
subfloor,wall covering or ceiling penetrated by the boot.
Concealed When required to be sealed,concealed fire
sprinklers sprinklers shall only be sealed in a manner that
is recommended by the manufacturer. ❑
Caulking or other adhesive sealants shall not be
used to fill voids between fire sprinkler cover
plates and walls or ceilings.
a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
2022-Feb-28 12:01:04
1 rightSQ$t` Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 12
...s\Wrightsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: St. Lucie Permit Number:
Job Information
Builder: PSL Prop Community: Lot:
Address: 4801 Sunset Blvd Unit:
City: Fort Pierce State: FL Zip: 34982
Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,orERl Method.
❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not
PERFORMANCE or ERI METHOD exceeding the selected ACH(50)value,as shown on FORM R405-2020(Performance)or
R406-2020(ERI),section labeled as Infiltration,sub-section ACH50.
ACH(50)specified on Form R405-2020-Energy Calc(Performance)or R406-2020(ERI): 7.000
X60= 13784 - Method for calculating building volume:
CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans
❑ PASS 0 Code software calculated
❑ When ACH(50) is less than 3, Mechanical Ventilation installation El Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.
(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals
licensed as set forth in Section 489.105(3)(f),(g),or(i)or and approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3. Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
2022-Feb-28 12:01:04
wrightS&L— Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy®Florida 2020 Section R405.4.1 Compliant Software Page 13
eafrty r mq r ...s\Wdghtsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
FORM R405-2020
Duct Leakage Test Report
Residential Perscriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: St. Lucie Permit Number:
Job Information
Builder: PSL Prop Community: Lot:
Address: 4801 Sunset Blvd Unit:
City: Fort Pierce State: FL Zip: 34982
Duct Leakage Test Results
System 1 cfm25 ❑ Prescriptive Method cfm25 (Total)
To qualify as"substantially leak free"Qn Total must be less
System 2 cfm25 than or equal to 0.04 if air handler unit is installed. If air handler
unit is not installed, Qn Total must be less than or equal to
System 3 cfm25 0.03. This testing method meets the requirements in
accordance with Section R403.3.3.
Sum of any Is the air handler unit installed <=0.04 Qn)
additional systems cfm25 ❑ YES 1-
Total of all during testing? ❑ NO 1<=0.03 Qn)
systems cfm25
0 Performance/ ERI Method cfm25(Out or Total)
1602 = On To qualify using this method, Qn must be not greater than the
Total of all Total Conditioned proposed duct leakage Qn specified on Form R405-2020 or
systems Square Footage R406-2020.
Leakage Type selected on Form Qn specified on Form R405-2020
R405-2020(Energy Calc)or R406-2020 (Energy Ca/c)or R406-2020
❑ PASS ❑ FAIL I Default Leakage 0.08
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set
forth in Section 489.105(3)(f), (g) or (i), Florida Statues.
Testing Company
Company Name: Phone:
I hereby verify that the above duct leakage test results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
2022-Feb-28 12:01:04
wrightSDft' Right-Suite®Universal 2021 21.0.11 RSU29066 Right-Energy® Florida 2020 Section R405.4.1 Compliant Software Page 14
A+ar.+rtL. w+ 'qr x;ry ...s\Wdghtsoft HVAC\4801 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N
Reference Home Characteristics
Sppec Home Title:4801 Sunset Blvd PSL Prop TMY City: FL—Fort—Pierce
4801 Sunset Blvd
Fort Pierce, FL 34982 FLBase202O
Above-grade Walls(Uo) 0.084
Above-grade Wall Solar Absor tance 0.75
9 P
Above-grade Wall Infared Emittance 0.90
Basement Walls(Uo) n/a
Above-grade Floors (Uo) n/a
Slab Insulation R-Value 0.0
Ceilings(Uo) 0.030
Roof Solar Absorptance 0.75
Roof Infared Emittance 0.90
Attic Vent Area(ft� 5.34
Crawls pace Vent Area(ft� n/a
Exposed MasonryFloorArea(ft� 404.40
Carpet&Pad R-Value 2.0
Door Area(ft� 0.00
Door U-Factor n/a
North WindowArea (ft� 0.00
South Wind ow Area(ft� 44.80
East Window Area(ft� 44.80
West Window Area(ft� 44.80
Window U-Factor 0.400
Window SHGC (Heating) 0.2169
Window SHGC (Cooling) 0.2169
ACH50 7.00
Internal Gains*(Btu/day) 68334
Water heater gallons per day 60.00
Water Heater set point temperature 120.00
Water heater efficiency rating 0.90
Labeled Heating System Rating and Efficiency HSPF=8.2
Labeled Cooling System Rating and Efficiency SEER= 14.0
Air Distribution System Efficiency 0.88
Thermostat Type Manual
Heating Thermostat Settings 72.0(All hours)
9h Load Short Form Job: 1402
writsoft- Date: Dec 29,2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:vicidlyrm@aircalcs.com
Project Information
For: Spec Home,NisAirAir Conditioning FILE ��
4801 Sunset Blvd,Fort Pierce,FL 34982
Design Information
Htg Clg Infiltration
Outside db(°F) 41 90 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD(°F) 29 15 Fireplaces 0
Daily range - L
Inside humidity(%) 30 50 EVI !11�-)-
Moisture difference(grAb) 2 57
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make Lennox
Trade Trade LENNOX
Model Cond ML14XC1S030-230A**
AHRI ref Coil CBA27UHE-030-230*++TDR
AHRI ref 10259437
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating input 6.9 kW Sensible cooling 20300 Btuh
Heating output 23456 Btuh Latentcooling 8700 Btuh
Temperature rise 22 °F Total cooling 29000 Btuh
Actual airflow 967 cfm Actual airflow 967 cfm
Airflowfactor 0.043 cfm/Btuh Airflowfactor 0.047 cfrnBtuh
Static pressure 0.70 in H2O Static pressure 0.70 in H2O
Space thermostat Load sensible heat ratio 0.78
ROOM NAME Area Htg load Clg load HtgA/F CIgAVF
(ft2) (Btuh) (Btuh) (cfm) (CFm)
M Hall 26 0 0 0 0
Laundry 68 908 1015 39 47
Master Bath 90 1993 784 86 37
WIC 63 1611 603 70 28
Master Bed 247 2013 2325 87 109
Pantry 15 0 0 0 0
Kltchen/Nook 275 3645 4882 158 228
Great Room 377 4764 6089 206 284
Bed 3 173 2938 2132 127 100
Hall 30 0 0 0 0
Lin 8 0 0 0 0
Bath 50 738 404 32 19
Bed 2 182 3738 2459 162 115
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft, 2022-Feb-2812:03:47
Right Sate(@ universal 2021 21.0.11 RSU29066
Page 1
...s\WrigMsoftHVACW801 Sunset Blvd PSLProp.np CaIc=MJe Front Door faces:N
House 1602 22348 20693 967 967
Other equip loads 1467 779
Equip.@ 0.95 RSM 20484
Latent cooling 6029
TOTALS 1602 23814 26513 967 967
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft- 2022-Feb-2812:03:47
IZgh-Sute®Uriversal2021 21.0.11 RSU29066
Page 2
s\WrigMsoftHVACW801Suset Blvd PSLProp.np Calc=MJ8 Frort Door faces:N
I
Building Analysis Job: 1402
u n
- wrightsoft° g Date: Dec 29,2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vicdlyme@aircalcs.com
Project • •
For. Spec Home,NisAirAir Conditioning
4801 Sunset Blvd,Fort Pierce,FL 34982
Design Conditions
Location: Indoor: Heating Cooling
St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD('F) 29 15
Latitude: 28°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9
Dry bulb(°F) 41 90 Infiltration:
Daily range(°F) - 15 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ftz Btuh %of load
Walls 3.1 4346 18.2 ventilation
Glazing 18.2 3253 13.7 wall
Doors 0 0 0 °as
Ceilings 1.0 1588 6.7
Floors 3.4 5392 22.6
Infiltration 2.0 2782 11.7 Glazin
Ducts 4987 20.9
Piping 0 0
Humidification 0 0 Infiltration
Ventilation 1467 6.2 Ceilings
Adjustments 0
Total 23814 100.0 Floors
Component Btuh/ftZ Btuh %of load
Walls 1.9 2691 12.5 Wall Ventilation
Glazing 20.6 3700 17.2
Doors 0 0 0 Internal Gains
Ceilings 1.8 2891 13.5
Floors 0 0 0 Glazing
Infiltration 0.6 778 3.6
Ducts 5613 26.1
Ventilation 779 3.6
Internal gains 5020 23.4
Blower 0 0 Ceilings
Adjustments 0 Ducts
Total 21472 100.0 Infiltration
Latent Cooling Load=6029 Btuh
Overall U-value=0.105 Btuh/ftz'F
Data entries checked.
wrightsoTt- 2022-Feb-2812:03:47
�� ^�•� wwp Right Skite@ Universal 2021 21.0.11 RSU29066 Page 1
...s\WrightsoftHVACW801Suset Blvd PSLProp.np Calc=MJ8 Front Doorfaces:N
I
Job: 1402
® Component Constructions
-�- wrightsoft Date: Dec 29,2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:vicidlyrne@aircalcs.com
Project Information
For. Spec Home,NisAirAir Conditioning
4801 Sunset Blvd,Fort Pierce,FL 34982
Design Conditions
Location: Indoor: Heating Cooling
St Lucie Co Inti,FL,US Indoor temperature(T) 70 75
Elevation: 26 ft Design TD(T) 29 15
Latitude: 28°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9
Dry bulb(T) 41 90 Infiltration:
Daily range(7) - 15 ( L ) Method Simplified
Wet bulb(T) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft' Btuh/ftt°F WFBtuh BtuhM2 Btuh BtuhV BWh
Walls
Blk Wall,Stucco Ext,R-4.1 Ext Bd inl,8"Thk,1/2"Gyp Bd Int Fnsh n 259 0.109 5.1 3.15 814 2.02 521
e 443 0.109 5.1 3.15 1395 2.02 892
s 239 0.109 5.1 3.15 755 2.02 483
w 245 0.109 5.1 3.15 772 2.02 494
all 1186 0.109 5.1 3.15 3736 2.02 2390
Knee Wall,Stucco,R-30,1/2"Gyp Bd Int Fnsh,2"A",16"O.C.Stud w 23 0.071 30.0 2.04 47 0.97 22
Partitions
Frm Wall,1/2"Gyp Bd Ext,R-11 Cav Ins,1/2"Gyp Bd Int Fnsh,2'k4",16" 192 0.101 11.0 2.94 564 1.46 280
OC Stud
Windows
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); n 10 0.580 0 16.8 160 11.5 109
50%blinds 45°,medium;50%outdoor insect screen;foreground=green
grass(0.23);1 ft overhang(3.17 ft window ht,1 ft sep.);8 ft head ht
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); a 31 0.580 0 16.8 525 28.1 878
50%blinds 45°,medium;50%outdoor insect screen;foreground=green
grass(0.23);1 ft overhang(5.2 ft window ht,1 ft sep.);8 ft head ht
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.21); a 48 0.650 0 18.8 905 13.1 627
foreground=green grass(0.23);10 ft overhang(8 ft window ht,1 ft sep.);
8 ft head ht
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); s 5 0.580 0 16.8 76 13.5 61
50%blinds 45°,medium;50%outdoor insect screen;foreground=green
grass(0.23);1 ft overhang(2.08 ft window ht,1 ft sep.);8 ft head ht
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.22); w 22 0.620 0 18.0 403 16.8 377
50%blinds 45°,medium;50%outdoor insect screen;foreground=green
grass(0.23);6 ft overhang(5.17 ft window ht,1 ft sep.);8 ft head ht
.= -rk wrightsoft- 2022-Feb-2812:03:47
Right Sute®Uriversal 2021 21.0.11 RSU29066 Page 1
s\WrightsoftHVAC4801 Sunset Blvd PSLProp." Cale=MJ8 FrontDoorfaces:N
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.22); w 16 0.620 0 18.0 280 27.2 424
50%blinds 45°,medium;50%outdoor insect screen;foreground=green
grass(0.23);1 ft overhang(5.2 ft window ht,1 ft sep.);8 ft head ht
Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); w 48 0.650 0 18.8 905 14.8 711
foreground=green grass(0.23);9.1 ft overhang(8 ft window ht,1 ft sep.);
8 ft head ht
Doors
(none)
Ceilings
Attic,Shngls,R-30 Roof Ins,1/2"Gyp Bd Int Fnsh 1602 0.034 30.0 0.99 1588 1.80 2891
Floors
On Grade Depth,Tile Fir Fnsh 188 0.989 0 28.7 5392 0 0
wrightsofft® 2022-Feb-2812:03:47
.w..• �wU gym, , Rigft-Sute®Uriversal202121.0.11 RSU29066 Page
s\WrightsoftWAC\4801 Suset Blvd PSLProp.np Calc=MJ8 Frort Door faces:N
t S Project Job:
�- 02
wrightsoft® � � Date: DecDc 29,2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:,Acldlyrm@aircaics.com
Project
For: Spec Home,NisAirAir Conditioningg
4801 Sunset Blvd,Fort Pierce,FL 34982
Notes:
Design Information
Weather: St Lucie Co Intl,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 41 of Outside db 90 °F
Inside db 70 °F Inside db 75 of
Design TD 29 °F Design TD 15 of
Daily range L
Relative humidity 50 %
Moisture difference 57 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17361 Btuh Structure 15079 Btuh
Ducts 4987 Btuh Ducts 5613 Btuh
Central vent(46 cfm) 1467 Btuh Central vent(46 cfm) 779 Btuh
Outside air Outside air
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 23814 Btuh. Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 20484 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2576 Btuh
Ducts 1676 Btuh
Central vent(46 cf n) 1778 Btuh
Heating Cooling Outside air
Area(ftz) 1602 1602 Equipment latent load 6029 Btuh
Volume(fP) 13784 13784
Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 26513 Btuh
Equiv AVF(cfrrl) 87 46 Req.total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Lennox
Trade Trade LENNOX
Model Cond ML14XC1S030-230A**
AHRI ref Coil CBA27UHE-030-230*++TDR
AHRI ref 10259437
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating Input 6.9 kW Sensible cooling 20300 Btuh
Heating output 23456 Btuh Latentcooling 8700 Btuh
Temperature rise 22 'F Total cooling 29000 Btuh
Actual airflow 967 cfm Actual airflow 967 cfm
Airflowfactor 0.043 cfm/Btuh Airflowfactor 0.047 cfm/Btuh
Static pressure 0.70 in H2O Static pressure 0.70 in H2O
Space thermostat Load sensible heat ratio 0.78
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-rk wrigFttsof[- 2022-Feb-2812:03:47
Right-Sute®Urkersal202121.0.11 RSU29066 Page
.AWdghtsoftHVAC\4801SusetBlvdPSLProp.Rip Calc=MJB Front Door faces:N
-Ffi-wrightsofta Right-JO Worksheet Job: Dec
Date: D Dec 29,2020
House
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.com
1 Room name House MHall
2 Exposed mail 188.0 ft 4.0 It
3 Room height 8.6 It 8.0 It heaV000l
4 Room dimensions 4.0 x 6.5 It
5 Room area 1601.8 ft 26.0 ft
Ty Construction U-value Or HTM Area (IiF) Load Area Load
number (Btuh4t�-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Blk Wall,Stucco Ext 0.109 n 3.15 2.02 268 259 814 521 0 0 0 0
Impact,Clear Lowe 0.580 n 16.82 11.48 10 0 160 109 0 0 0 0
W Blk Wall,Stucco E)d 0.109 a 3.15 2.02 522 443 1395 892 0 0 0 0
Impacs Clear Lowe 0.580 a 16.82 28.13 31 0 525 878 0 0 0 0
11 Impact,Clear Lowe 0.650 a 18.85 13.06 48 44 905 627 0 0 0 0
V1! Blk Wall,Stumo Ext 0.109 s 3.15 2.02 244 239 755 483 0 0 0 0
G Impact Clear Lowe 0.580 s 16.82 13A8 5 5 76 61 0 0 0 0
W Blk Wall,Stuooc Ext 0.109 w 3.15 2.02 331 245 772 494 0 0 0 0
Impact,Clear Lowe 0.620 w 17.98 16.83 22 17 403 377 0 0 0 0
Impact,Clear Lowe 0.620 w 17.98 27.18 16 0 280 424 0 0 0 0
Impact Clear Lowe 0.650 w 18.85 14.81 48 39 905 711 0 0 0 0
W Knee Wall,Stuom,R 0.071 w 2.04 0.97 23 23 47 _ 22 0 0 0 0
P_ Frm Wall,1 Q-Gyp B 0.101 2.94 1 A6. 192 192 564 280 32 32 94 47
C At5c,Shngls,R-30 0.034 - 0.99 1.80 1602 1602 1588 2891 26 26 26 47
F On Grade Depth,Tile 0.989 - 28.68 0.00 1602 188 5392 0 26 4 115 0
6 c)AED e)mrsion 514 -5
Envelopeloss/gain 14579 9282 235 89
12 a) Infiltration 2782 778 0 0
b) Roomtentilation 0 0 0 0
13 Internal gains Oooupants@ 230 4 920 0 0
Appliances/other 4100 0
Subtotal(lines 6 to 13) 17361 15079 235 1 89
Less extemalload 0 0 0 0
Less transfer 0 0 0 0
Redishibution 0 0 -235 -89
14 Subtotal 17361 15079 0 0
15 Duct loads 29% 37% 4987 5613 29% 37% 0 0
Total room load 22348 20693 1 0 0
Air required(cfrn) 967 967 0 0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-F4F 2022-Feb-2812:03:47
Right-Sute®Universal 2021 21.0.11 RSU29066
AC�P. Page 1
...s\WrightsoftHVACW801Su1setBlvdPSLProp.rtp CaIc=MJB Front Doorfaces:N
+�+wrightsoft" Right-JO Worksheet Job: 1402
House Date: Dec 29,2020
By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.00m
1 Room name Laundry Master Bath
2 Exposecivell 10.5 ft 21.5 ft
3 Room height 8.0 ft heaVcool 8.0 ft heaUmol
4 Room dimensions 10.5 x 6.5 ft 7.5 x 12.0 ft
5 Room area 68.3 112 90.0 ft'
Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load
number (Btuhrt12--°F) (BtuhAn or perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
Heat Cool Gross N/P/S Heat Cool Gross NA'/S Heat Cool
6 Blk Wall,Stuaro E)d 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0
t�G Impact ClearLowe _ 'U80 n 16.82 _ 11A8 _0 0 0 0 _ 0 0 , , 0 _0
WI - Blk Wall,Stuoco E)d 0.109 a 3.15 2.02 0 0 0 0 16 16 M 32
Impact Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 0 0 0 0
11 Impact,Clear Lowe 0.650 a 18.85 13.06 0 0 0 0 0 0 0 0
V,V Blk Wall,Stuom Ext 0.109 s 3.15 2.02 0 0 0 0 96 91 288 184
!_ _ G Impact Clear Lowe_ 0.580_ s _ 16.82 13.48_ 0 0 __ 0 0 __5 5 76 _61
W4
Blk Wall,Stu000 6d 0.109 w 3.15 2.02 0 0 0 0 12 12 38 24
Impact Clear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.650_ w 18.85 14.81 _ 0 0 0 0 0 0 0 0
W Knee Wall,.Stuoso,.R 0.071 w _. 2.04. . .0.97 _ --0 0 0 ._ 0 0 0 0 -_0
P Frm Wall,1l2"Gyp B 0.101 - 2.94 1.46 84 84 2.47 123 48 48 141 70
C Atfiq Shngls,R-30 _ -0.034 - 0.99 1.80 ,68 68 68 123 90 90 89 _ 162
F On Grade Depth,Tile 0.989 - 28.68 0.00 68 11 301 0 90 22 617 0
6 c)AED excursion 40 -32
En%elopeloss/gain 616 206 1299 502
12 a) Infiltration 0 0 249 69
b) Room ventilation 0 0 0 0
13 Intemal gains Occupants @ 230 0 0 0 0
Appliances/other 500 0
Subtotal(lines 6 to 13) 616 706 1548 1571
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 90 34 0 0
14 Subtotal 705 740 1548 571
15 DuctloadS 129% 37%1 203 275 29% 37% 445 213
Total room load 908 1015 1993 784
Air required(cIm) 39 47 86 37
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ f�F wrYgF�tsoft- 2022-Feb-2812:03:47
Right-SUte®Uriiversal202121.0.11 RSU29066 Paget
sUrightsoftHVACk1801 Sunset Blvd PSL Prop.rLp Calc=MJ8 Front Door faces:N
+F-wrightsoft" Right-JO Worksheet Job: Dec
Date: D Dec 29,2020
HODS@
By. Chris Bateman
Air Calks, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Plane:772.800.8413 Email:vicldlyme@aircalcs.com
1 Room name WIC Master Bed
2 Exposed vAA 17.0 ft 14.5 it
3 Room height 8.0 ft heat/cool 8.5 ft heattoml
4 Room dimensions 5.5 x 11.5 ft 14.5 x 17.0 ft
5 Room area 63.3 ft' 246.5 T
Ty Construction U-value Or HTM Area Load Area Load
number (Btuh/t'-'F) (Btuhffl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross NFIS Heat Cool Gross N/P/S Heat Cool
6 V�J Blk Wall,Stucco E:d 0.109 n 3.15 2.02 0 0 0 0 0 0 0 6
_1--G Impact,Clear Lowe 0.580 n 16.82 _ 11.48 - , _ _0 0 -- 0 --0 _ -0 0 0 0
W Blk Wall,Stucco Ex< 0.109 a 3.15 2.02 44 44 139 89 123 108 339 217
Impact Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 16 0 262 439
11 Impact Clear Lowe 0.650 a 18.85 13.06 0 0 0 0 0 0 _ 0 0
tV� Blk Wall,Stucco E)d 0.109 s 3.15 2.02 92 92 290 185 0 0 0 0
=G Impact Clear Lower_ 0.580 s 16.82 .- 13A8 __ _ _. 0 0 0 0 0 -_ 0 0 0
Wf - Blk Wall,Stucco 6d 0.1 09 w 3.15 2.02 0 0 0 0 0 0 0 0
I--c� Impact Clear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 0 0 0 0
Impact Clear Lowe_ 0.650 w 18.85 14.81 0 0 0 0 0 0 0 0
W _ Knee Wall,Stucco,R- .110.071 w 2.04,
P Frm Wall,10 Gyp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0
-C. ._ Atfiq Shngls,R-30 0.034 _ - 0.99 1.80 _ 63 63 _ 63 114 247 247 _ 244 445
F On Grade Depth,Tile 0.989 28.68 OAO .63 17 488 0 247 .,15 416 0
6 c)AED exarsion -25 3
Envelope losstgain 979 364 1262 1104
12 a) Infiltration 273 76 247 69
b) Room ventilation 0 0 0 0
13 Internal gairm Occupants @ 230 0 0 0 0
Appliancedother 0 500
Subtotal(lines 6 to 13) 1251 440 1509 1673
Less edemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 55 21
14 Subtotal 1251 440 1564 1694
r
Dud loads 129% 37%1 359 164 291/. 37% 449 631
Total room load 1611 603 2013 2325
Air required(dm) 70 28 87 109
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-R}d- wrigF�tsoTt� 2022-Feb-2812:03:47
Right-Sute®Universal 202121.0.11RSU29066 Page
sUrightsoftHVAC\4801 SusetBlvd PSL Prop.rup Cale=MJ8 Front Door faces:N
t wrightsoft, Right-JO Worksheet Job: 1402
House Date: Dec 29,2020
By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:vic$dlyrm@aircaics.com
1 Room name Pantry KtcrenMook
2 Exposed mall 0 ft 23.5 It
3 Room height 8.0 ft heat/cool 9.3 ft heaticool
4 Room dimensions 5.0 x 3.0 ft 1.0 x 274.5 ft
5 Room area 15.0 ft 274.5 ft=
Ty Construction U-value Or HTM Area (ft� Load Area Load
number (BtuhAF--°F) (BtuhAt� or perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
Heat Cool Gross NJP)S Heat Cool Gross NiP/S Heat Cool
6 V+J Blk Wall,SWow EM 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0
c, Impact,ClearL_cwe 0.580 n 16.82 _ 11A8 0 0 _ 0 0 _0 0 _ _ 0 0
UV Blk Wall,Stucco 6d 0.109 a 3.15 2.02 0 0 0 0 219 171 537 344
Impact,Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 0 0 0 0
11 Impact Clear Lowe 0.650 a 18.85 13:06 0 0 0 0 48 44 905 627
V,V Blk Wall,Stu mo Ext 0.T 09 s 3.15 2.02 0 0 0 0 0 0 0 0
1--G Impact Clear Lowe „0.580 s 16.82 : .13A8 _ 0 _ _ _ 0 _ 0 0 _ 0 0 0 0
W Blk Wall,Stucco Eid 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 0 0 0 0
Impact.Clear Lowe_ 0.650 w 18.85 _ 14.81 _ _ 0_ 0 0 0 0 --0 0 0
W_ _ Knee Wall,Stu000,.R _ .,10.071 w 2.04 0.97 _- -0 _. 0 _.... 0 _ 0 0 _._0 _ 0 __. 0
P Frm Wall,1l2"Gyp B 0.101 - 2.94 1.46 0 0 0 0 0 0 0 0
C. Attiq Shngls,R730. _ 0.034 7_ 0.99 1.80 15 ._ 15 _ _ 15 27 275 275 272 495
F On Grade Depth,Tile 0.989 28.68 0.00 15 0 0 0 275 24 674 0
6 c)AED e)=rsion -1 -200
Envelope lossigain 15 26 2388 1266
12 a) Infiltration 0 0 438 122
b) Room ventilation 0 0 0 0
13 Internal gains Occupants@ 230 0 0 2 460
Appliancesrother 0 1700
Subtotal Qines 6 to 13) 15 26 2826 3549
Less exdemalload 0 0 0 0
Less transfer 0 0 0 0
Redistribution -15 -26 5 9
14 Subtotal 0 0 2832 3558
15 Ductloads 29% 37% 0 0 29% 37% 813 1324
Total room load 0 0 3645 4882
Air required(cm) 0 0 158 228
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-�'�- wr7ghtsoT-t'^ 2022-Feb-2812:03:47
MgYISute®Universal 202121.0.11 RSU29066 Page4
s\WrightsoftWACW801Surwt Blvd PSLProp.np Calc=MA Front Door faces:N
-t -wrightsofta Right-JO Worksheet Job: 1402
House Date: Dec 29,2020
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.com
1 Room name Great Room Bed 3
2 Exposed Hell 29.0 It 27.0 ft
3 Room height 9.3 It heat/000l 8.0 ft heaYbool
4 Room dimensions 26.0 x 14.5 ft 1.0 x 172.5 It
5 Room area 377.0 T 172.5 fe
Ty Construction U-value Or HTM Area Load Area (T) Load
number (BtuhA?-°F) (Btuh/M or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool
6 V,V Blk Wall,Stucco E)d 0.109 n 3.15 2A2 6 0 0 0 96 96 302 193
�--G Impact Clear Lowe. 0.580 n 16.82 11 A8 0 _ __ 0 0 0 0 0 _ 0 0
1W _ Blk Wall,Stuco Ext 0.109 a 3.15 2.02 0 0 0 0 120 104 329 210
�-ci Impact Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 16 0 262 439
11 G� Impact Clear Lowe 0.650 a 18.85 13.06 0 0 0 0 0 0 0 0
�j Blk Wall,Stucco Ext 0.109 s 3.15 2.02 '0 0 0 0 0 0 0 0
!_ G_ Impact,Clear Lowe '0.580 _s 16.82 13A8 _ 0 0 __ __0 0 0 0 0 0
IW _ Blk Wall,Stucco Ext 0.109 w 3.15 2.02 219 149 468 300 6 0 0 0
Impact Clear Lowe 0.620 w 17.98 16.83 22 17 403 377 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.650 w 18.85_._ 14.81 48 39 905 711 0 0 0 0
W Knee Wall,Stucco,R 0.071 w 2.04 0.97 23. 23 _ .___47 _ 22 0 0 0 0
P Frm Wall,ll2"Gyp B 0.101 2.94 1.46 28 28 82 41 0 0 0 0
C Attic;Shng1s,R-30 0.034 0.99 1.80 _ 377 377 374 680 173 173 171 311
F On Grade Depth,Tile 0.989 28.68 0.00 377 29 832 0 173 27 774 0
6 c)AED exrursion 748 11
Emelopeloss(gain 3110 2879 1839 1165
12 a) Infiltration 485 136 433 121
b) Room venfilation 0 0 0 0
13 Internal gains Oocopants @ 230 2 460 0 0
Appliances(other goo 250
Subtotal Qines 6 to 13) 3595 4374 2272 1536
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 106 62 10 17
14 Subtotal 3701 4437 2282 1554
15 Ducloads 129% 37%1 1063 165 9.1 37%1 6561 578
Total room load 4764 6089 2938 2132
Air required(dm) 206 284 127 100
Calculations approved byACCAto meetall requirements of Manual J 8th Ed.
-4- wrGgtitsolFt^ 2022-Feb-2812:03:47
Right-Srite@)Uriversa1202121.0.11RSU29066
ACCA Page 5
sUrightsoftHVACW801Surset Blvd PSLProp.rp Calc=MJ8 Front Door faces:N
I
-�-wrightsoft• Right-J®Worksheet Job: 1402
House Date: Dec 29,2020
By: Chris Bateman
Air Calks, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:%,iddlyme@aircaics.com
1 Room name Hall Lin
2 Exposed well O ft O ft
3 Room height 8.0 It heat/cool 8.0 it heaUcool
4 Room dimensions 3.5 x 8.5 ft 2.5 x 3.0 It
5 Room area 29.8 ft' 7.5 fe
Ty Construction U-value Or HTM Area Load Area Load
number (Btuh/It-°F) (BbjW or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Blk Wall,Stucco E)d 6.109 n 3.15 2.02 6 0 0 0 6 0 0 0
Impact,Clear Lowe 0.580 n 16.82 11A8 0 ,. 0 ._ 0 0 0 0 _ 0 0
W Blk Wall,Sfucao Ext 0.109 a 3.15 2.02 0 0 0 0 0 0 0 0
Impa4ClearLowe 0.580 a 16.82 28.13 0 0 0 0 0 0 0 0
11 Impaq Clear Lowe 0.650 a 18.85 _ 13.06 0 0 0 0 0 0 0 0
t�j Blk Wall,Stucco Ext 0.109 s 3.15 2.02 6 0 0 0 0 0 0 0
-,! _G Impact,Clear Lowe 0.580 _s 16.82 13A8 0 0 0 0 0 0 0 _ 0
w - Blk Wall,Stucco Ext o.169 w 3.15 2.02 0 0 0 0 0 0 0 0
Impact,Clear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0
Impact,Clear Lowe 0.620 w 17.98 27.18 . 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.650 w 18.85. _ 14.81 0 0 0 0 0 0 0 0
YV Knee Wall,Stucco,R. 0.071 w 2.04 0.97-_ 0 0 0 0 0 0 _ 0 0
P Frm Wall,IM'Gyp B 0.101 - 2.94 _ 1.46 _ 0 0 0 0 0 0 0 0
C Atliq Shngls R-30. _ 0.034 _- 0.99 1.80 30 30 29 _ 54 8 8 7 14
F On Grade Depth,Tile 0.989 - 28.68 0.00 30 0 0 0 8 0 0 0
6 c)AED excursion -3 -1
Envelopeloss/gain 29 51 7 13
12 a) Infillration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Ooorpants@ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 29 51 7 13
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution -29 -51 -7 -13
14 Subtotal 0 0 0 0
15 Dudloads 29% 37% 0 0 29% 37% 0 0
Total room load 0 0 0 0
Air required(c1m) 0 0 0 0
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
Af*- wrYgF�tsoft- 2022-Feb-2812:03:47
ACC IN "^ Riglft-Sute®Universal 2021 21.0.11 RSU29066 Page
s\WrightsoftHVAC\4801 Sunset Blvd PSLProp.rp Calc=MJ8 Front Door faces:N
-�1-wrightsoft' Right-JO Worksheet Job: 1402
House Date: Dec 29,2020
By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vi&lyme@aircalcs.com
1 Room name Bath Bed 2
2 Exposedvell 5.5 It 35.5 It
3 Room height 8.0 ft heaVmol 8.0 it heatlmol
4 Room dimensions 9.0 x 5.5 It 1.0 x 182.0 ft
5 Room area 49.5 fl' 182.0 IF
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (BtjW-'F) (Btuh/" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Blk Wall,Stucco Ext 0.109 n 3.15 2.02 44 35 109 70 128 128 403 258
Impact,Clear Lowe 0.580 n 16.82 11 A8 10 0 160 109 0 0 0 0
W Blk Wall,Stumo Ext 0.109 a 3.15 2.02 0 0 0 0 0 0 0 0
Impact,Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 0 0 0 0
11 Impact Clear Lowe 0.650 a 18.85 13.06 0 0 0 0 0 0 0 0
�j Blk Wall,Stu000 Ext 0.109 s 3.15 2.02 0 0 0 0 56 56 176 113
G Impact Clear Lowe 0.580 s 16.82 13A8 0 0 0 0 0 0 0 0
Li
W Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 100 84 266 170
ImpactClear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0
Impact Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 16 0 280 424
Imoad Clear Lowe 0.650 w 18.85 14.81 0 0 0 0 0 0 0 0
W Knee Wall,Stud,R 0.071 w 204 0.97 0 0 0 0 0 0 0 0
P Frm Wall,1)2"Gyp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0
C Atfic,Shngls,R-30 0.034 0.99 1.80 50 50 49 89 182 182 180 328
F On Grade Depth,Tile 0.989 28.68 0.00 50 6 158 0 182 36 1018 0
6 c)AED excursion -16 72
Envelope loss/gain 475 252 2325 1366
12 a) Infiltration 88 25 569 159
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants@ 230 0 0 0 0
Applianceother 0 250
Subtotal(lines 6 to 13) 564 277 2894 1775
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 10 17 10 17
14 Subtotal 574 294 2904 1792
15 Ducloads 1 29% 37% 165 110 29% 37% 8341 667
Total room load 738 404 3738 2459
Air required(dm) 32 19 162 115
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ -P}r wrYgtitsoft^ 2022-Feb-2812:03:47
Right-Sute®Universal2021 21.0.11 RSU29066ACCA Pagel
s\WrightsoftHVACW801 Sirwt Blvd PSLProp.np Calc=MJ8 Front Door faces:N
Duct System Summary Job: 1402
wrightsoft® Date: Dec 29,2020
House By. Chris Bateman
Air Calks, LLC
7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:%icidlyrne@aircal s.com
Project Information
For. Spec Home,NisAirAir Conditioning
4801 Sunset Blvd,Fort Pierce,FL 34982
Heating Cooling
External static pressure 0.70 in H2O 0.70 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.70 in H2O 0.70 in H2O
Supply/return available pressure 0.559/0.141 in H2O 0.559/0.141 in H2O
Lowest friction rate 0.291 in/100ft 0.291 in/100ft
Actual airflow 967 cfm 967 cfrn
Total effective length(TEL) 240 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk
Bath h 738 38 23 0.311 4.0 OxO MFx 44.8 135.0 st3
Bed 2 h 3738 194 138 0.291 7.0 Ox 0 MFx 51.8 140.0 st3
Bed 3 h 2938 152 120 0.294 7.0 Ox 0 MFx 49.9 140.0 st3
Great Room C 3044 124 171 0.383 7.0 Ox0 MFx 36.0 110.0 st2
Great Room-A C 3044 124 171 0.381 7.0 Ox 0 MFx 36.8 110.0 st2
KitchenNook c 2441 95 137 0.380 6.0 Ox 0 MFx 37.0 110.0 st2
KitchenNook-A c 2441 95 137 0.383 6.0 Ox 0 MFx 36.0 110.0 st2
Landry C 1015 47 57 0.656 4.0 OXO MFx 5.2 80.0
Master Bath h 1993 103 44 0.464 5.0 Ox 0 MFx 20.3 100.0 st1
Master Bed C 1162 52 65 0.475 5.0 Ox 0 MFx 22.6 95.0' st1
Master Bed-A C 1162 52 65 0.487 5.0 OX 0 MFx 19.8 95.0 st1
WIC h 1611 84 34 0.486 5.0 Ox0 MFx 20.0 95.0 st1
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk
st1 PeakAVF 292 208 0.464 835 8.0 0 x 0 UnIFIX
st3 PeakAVF 385 280 0.291 871 9.0 0 x 0 UnlFlx st2
st2 PeakAVF 821 895 0.291 837 14.0 0 x 0 VinlFlx
wrightsoft® 2022-Feb-2812:03A7
-I*----'-- Right Sute®UNversal2021 21.0.11 RSU29066
Page 1
s\WrightsoftHVACk801 Sunset Blvd PSL Prop.nQ Calc=MJ8 Front Doorfaces:N
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk
rb5 Ox0 188 164 48.5 0.291 539 8.0 0x 0 VIFx
rb6 Ox0 625 738 0 0 0 0 Ox 0 VIFx
rb4 Ox0 194 138 0 0 0 0 Ox 0 VIFx
rb3 Ox 0 152 120 0 0 0 0 Ox 0 VIFx
Bolditalic values have been manually overridden
wrightsoft® 2022-Feb-2812:03:47
,V�/y� Right-Sute®Uriversal202121.0.11 RSU29066 Page2
AMA
E WrightsoftHVACW801 SuisetBl�dPSLProp.rLQ Calc=MJ8 FrortDoorfaces:N
Job: 1402
-�+ wrightsoft® Manual S Compliance Report Date: Dee 29,2020
House By. Chris Bateman
Air Calks, LLC
7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vicdlyme@aircalcs.com
Project • •
For: Spec Home,NisAirAir Conditioning
4801 Sunset Blvd,Fort Pierce,FL 34982
Cooling Equipment
Design Conditions
Outdoor design DB: 90.4'F Sensible gain: 21472 Btuh Entering coil DB: 76.9°F
Outdoor design WB: 77.4°F Latent gain: 6029 Btuh Entering coil WB: 64.0°F
Indoor design DB: 75.0°F Total gain: 27501 Btuh
Indoor RH: 50% Estimated airflow: 967 ch
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SplitAC
Manufacturer. Lennox Model: ML14XC1S030-230A**+CBA27UHE-030-230*++TDR
Actual airflow: 967 chn
Sensible capacity: 20300 Btuh 95%of load
Latent capacity: 8700 Btuh 144%of load
Total capacity: 29000 Btuh 105%of load SHR: 70%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 23814 Btuh Entering coil DB: 68.17
Indoor design DB: 70.07
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Elec strip
Manufacturer: Model:
Actual airflow: 967 ch
Output capacity: 6.9 kW 98%of load Temp.rise: 50 °F
Meets all requirements ofACCA Manual S.
-*- wrightsoft® 2022-Feb-2812:03:48
1, ...,..N�a..t,�•ewm.-.CC Right-Sute@Uriversal2021 21.0.11 RSU29066
Page 1
...s\WrighlsoftHVACW801 Suset Blvd PSL Prop.nQ Calc=MJ8 Front Door faces:N
iL
F4K
Le el
12x8 we
152dm '10x10 10x10 8x8
f 137dm 137 dm f 65 d'm 1'
Bed3 '- -' Kdchen/Nock i 5• i 1ax8
12x12 84 cin
50CFM 152dm 6• 6• Master Bed 5•
4"Duct 8x8
4'Exaustlknt s° P VY 65drm
1 5
38 a• 7' 9" 188 cr 5• 80 CFM
38 dm 4' 188 dm
10x6 4"Dud
Bath 103 din 4'Exaust Vent
18x18 7, 7' 7' 6' M Flan 10x6 14' i
Lin II 4 7dm
s•
�? Great Room r2O2O Laundry Master Bath
12x8 1 d
2x12 i 10x10 10x10 i
194 dm 194 aim 171 in 171 dm
Bed 2 Hll/V
Equipment Schedule: FRI
LENNOX
Cond ML14XC1S030-230A" Garage
Coil CBAVLIHE-030-230*+TDR
AHRI ref 10259437
Efficiency 13.0 EER,16 SEER
Sensible cooling 20300 Btuh
Latent cooling 8700 Btuh
Total cooling 29000 Btuh
Job M 1402 Air Calcs, LLC Scale:1 :136
Performed by Chris Bateman for: Page 1
Spec Home 7550 Hidden Hammock Ln RightSuite®Universal 2021
4801 Sunset Blvd Vero Beach,FL32966 21.0.11 RSU29066
Fort Pierce,FL34982 Phone:772.800.8413 2022-Feb-28 12:07:42
vickilynne@aircalcs.com ...AC\4801 Sunset Blvd PSLProp.rup