Loading...
HomeMy WebLinkAboutCentral Air System InvoicePage 1 Residential Heat Lose and Heat Gain Calculation In accordance with ACCA Manual J Report Prepared By: Central Air Systems Inc. For. Frtherlin 1053 Jensen beach f Nt F7 pierce, ft 34957 Design Conditions: Fort Pierce Indoor. Summer temperature: Winter temperature: Relative humidity: 6/16/2015 Outdoor: 70 Summer temperature: 90 70 Winter temperature: 42 55 Summer grains of moisture: 127 Daily temperature rangeMedium Building Component Sensible Latent Total Total Gain Gain Heat Galin Heat Loss (BTUH) (BTUH) (STUN) (BTUH) Duct 2,832 0 2,832 2,008 Floors 983 0 983 1,741 Walls 1,423 0 1,423 1,688 Ceilings. 3,638 0 3,638 2,315 People Fireplaces Misc 1,200 0 1,200 920 0 0 2,120 0 1,200 0 0 . 0 Windows 7,413 0 7,413 2,694 Doors 0 0 0 0 Glassdoors 1,872 0 1,872 1,261 Skylights 0 0 0 0 Infiltration 1,144 2,369 3,513 3,552 Whole House 21,705 3,289 24,994 (2 tons ) 15,365 HVAC-Calc Residential 4,0 by HVAC Computer Systems Ltd. stm rw3-1-1u-1 Load ealc miens are asummms only, vaual toads may very due IDw*ww and cvMftw ian dVfwenaes. Z'd SZ096Etâ–ºi9S zeijai-4ng u -1 Wd22=T SToa 9T unr