HomeMy WebLinkAboutBuilding PlansROOF EDGE 1 HIP PD END ROOF EDGE R803.2.3.1 SHEATHING FASTENINGS. WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH 8D RING - SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE FRAMING. ZONE RING -SHANK NAILS SHALL HAVE THE FOLLOWING MINIMUM DIMENSIONS, ZONE 2 I. 0,113 INCH NOMINAL SHANK DIAMETER. ZONE 3 2. RING DIAMETER OF 0,012 OVER SHANK DIAMETER. 3.16 TO 20 RINGS PER INCH. 4. 0.280 INCH FULL ROUND HEAD DIAMETER. 5.2 INCH NAIL LENGTH. ROOF SHEATHING NAILING ZONES O O O O O O O 2 O RIDGE O O O O O O O O r PERIMTER TO BE SQUAQE 120UND HANDRAIL PROFILE DETAIL NOT TO SCALE LANDING 4" CONC. HIGH WALL JNTED HANDRAIL --x5 EA. BULLNOSE .tea a = 5 ALIGNED (D EA. SIDE OF STAIRS CLEAN, TREATED AND (I) AT MIDPOINT COMPACTED FILL (4) RISERS AT 7.5" CONCRETE (3) TREAD AT 10" STAIRS (D LANDING USE 3000 PSI I" BULLNOSE CONCRETE ENTRY STAIR RISER N.T.S. I-I/7 OR 5/4' X 6' P.T. DECKING W(3} 16D AT EACH JOIST P.T. GUARDRAIL (2) SIDES OF LANDING 4' X 4' ORr82 POSTS I-I/2' OR 5/4' X P.T. DECKR 7X8'P.T_ FLOOR JOISTS (2) I/2' DIA. BOLTS WOOD POSTS TO - RIM JOISTS Nc0 P.T. BAL LESS THAN 4' 3'-88" 4.12S AT EA. (y I/r DIA BOLTS JOIST TO RIM TH WAYS, POST `JOncISTS BOTH TO RIM JOISTS ai RIM 2' X 8' FLOOR JOISTS TOP VIEW J"0�0° i�OI (3) 7 X 17 P.T. 5TRING625, (I) EA SIDE E (D AT MIDPOINT (4) 7-I/7 RIS62S (3) 10' TREADS I I/7 DIA. BOLTS DST TO ST12INGE3R P.T. GUARDRAIL (2) SIDES CE OF LANDING �� c POSTS P.T. BOTTOM RAIL I-I/2' OR 5/4' X 6' P.T. DECKING, I/S° SPACING WOOD POSTS TO RIM JOISTS SEAR STAIR RISER N.T.S. ST. LUCIE COUNTY BUILDING DEPARTMENT PRODUCT APPROVAL CHECKLIST PERMIT TYPE S.F.R. PERMIT NUMBER OWNERS NAME MR. E MRS. BAXTER DESIGN PROFESSIONAL NAME A/E JOHN N, CRESWELL, PE JOB SITE LOCATION 612 VENTURE ST. LUCIE 10967 S OCEAN DRIVE, JENSEN BEACH, FL 34957 RULE 9 B-72 REQUIRES THE FOLLOWING INFORMATION AS PROMULGATED BY THE FLORIDA BUILDING COMMISION, IN THE EVENT THAT INFORMATION REQUIRED FOR PRODUCT APPROVAL HAS BEEN INCORPORATED IN TO TE PLANS, SPECIFICATIONS OR GENERAL NOTES, SIMPLY INDICATE PAGE NUMBERS ON THE AFFIDAVIT. PRODUCT MODEL NUMBER MANUFACTURER EVALUATION AGENCY NOA NUMBER EXPIRATION DATE WINDOWS -SINGLE HUNG SERIES SH-7700 LAWSON IMPACT GLASS MIAMI-DADE 12-0127.16 12/27/2016 WINDOWS -FIXED GLASS SERIES "PW" 4200/6200 LAWSON IMPACT GLASS MIAMI-DADE 12-0307.06 08/22/2017 MULL BARS ALUMINUM TUBE LAWSON MIAMI-DADE 12-0127.07 05/30/2017 EXIT DOOR, SOLID CORE EXTERIOR HINGED DOOR THEf'MA-TRU FLORIDA BUILDING CODE FL 5891-23 NA ROOFING MATERIAL 5V-CRIMP J.M. METALS FLORIDA BUILDING CODE FL 12966.E NA IN ACCORDANCE WITH THE FLORIDA ARCHITECTS AND ENGINEERS PRODU(WT APPROVAL SYSTEM THIS AFFIDAVIT CERTIFIES THAT I HAVE PERFORMED THE BUILDING ENVELOPE EVALUATION AS REQUIRED BY THE FLORIDA BUILDING CODE. JONN H. CRESWELL, PE PE# 40940, COA# 27002 ARCHITECT/ENGINEERS'S SIGNATURE FL. CERT./REG. NUMBER 5/8' DIA/ WEDGE AN 4' EMB®IMHJ IN CC POST TI TYPICAL STAIR ATTACHEMENT TO HOUSE N.T,S, TOPRAIL P.T. GAL LESS THAN 4' HANDRAIL T. BALUSTERS SS THAN 4' SPACE - LANDING r x Ir P.T. BRA MOUNT STRIM I-12' OR 5/4 J TREADS E RISERS (4) RISERS AT 7.5" ea,2coir� (3) TREADS AT 10" (I) LANDING WOOD FRAME I" BULLNOSE STAIRS (3)TX17 P.T. wooD STRINGERS (D EA. SIDE E (D AT MIDPOINT (3) TX 17 P.T. WOOD ST12ING62S iD EA SIDE E (D AT MIDPOINT GENERAL NOTES' I. CONSTRUCTION SHALL FOLLOW 'FLORIDA BUILDING CODE" AS ADOPTED BY THE AREA IN WHICH THE BUILDING IS TO BE 2. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS. OVER SCALED DIMENSIONS. 4. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. DESIGN LOADS IN ACCORDANCE WITH FBC CHAP. 16 STUCTURAL NOTES 3. ALL STRUCTURAL CONCRETE_ SHALL NAVE A MINIMUM COMPRESSIVE 2. SOIL BEARING CAPACITY 2500 PSF STRENGTH OF 3000 PSI AT 28 DAYS. 4. SLAB/FOOTINGS TO BE CONCRETE WITH MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLANS FOR SIZE AND STEEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS FOOTINGS' 3' BEAMS I-I/2" SUSPENDED SLABS' I" 6. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. GRADE 60 STEEL MINIMUM IN FOOTINGS AND SLAB. GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE. IO.BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF THE BEARING MEMBER WHEN THE BEARING MEMBER IS 2 OR MORE PLIES UNLESS NOTED. II. ROOF SHEATHING TO BE NAILED WITH IOD GALV. 12.FRAME TO MASONRY SEGMENT CONNECTIONS, PT 2 X 4 MINIMUM TO MASONRY WITH I/2' DIAMETER 7" EMBEDMENT WEDGE 0DL81$12AR6E®P4fJm(N6i/>BGS"3WvLWAiG(11TM@I.AND 6' O.C. IN FIELD MALL SOILS TO BE COMPACTED TO MIN. 95% DENSITY 14.CORNER BARS ARE REQUIRED AT ALL OUTSIDE CORNERS 15.FOOTINGS SHALL BE A MIN. OF 16' IN WIDTH OR AS INDICATED ON DRAWINGS 16.20OF DL E LL - 55 P.S.F. 17.UPLIFT FORCES AS PER ENGINEERS NOTES AND SCHEDULES 18.FLOO12 ILL - NA 19.ALL PRE -CAST LINTELS TO HAVE MIN.6' BEARING 20.ALL STANDARD LUMBER SHALL BE SPF WITH A MINIMUM FB OF PENETRATIONS THROUGH ANY SEPARATION SHALL BE PROTECTED BY FILLING THE OPENING AROUND THE PENETRATING ITEM WITH APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. SEE TYPICAL WALL SECTION FOR FOOTING DETAILS EMBED =5 DOWEL 7" INTO FOOTING W/EPDXY MISSED DOWEL DETAIL STRAP TO TRUSS ATTACHED ��TAPCONSK W/(3)- 3 Ifi XI-3/4' TYPICAL CONC.BLK .. EXTERIOR WALL MISSING TRUSS STRAP DETAIL ��1(i�'{�^.I "Ili" iir,�".• �7P, ST. LUCIE COUNTY �lf� _D Q' PUBLIC WORKS DEPARTMENT ! v CODE COMPLIANCE DIVISIONST. LUCIE couNTv BUILDING DIVISION 2308 VIRGINIA AVENUE REVIEWED FORT PIERCE, FL 34962 FORcaM �E 772-462-155 REVIEWED BY ,°._ DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE DATE , e� P ro NS AN PEhM T MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE THIS CERTIFICATION MUST BE COMPLETED BY THE PROJECT DESIGNER, ARCHITECT OR ENGINEER. THIS CERTIFICATION MUST BE SUBMITLAD IN DUPLICATE WITH ALL APPLICATIOAS FOR BUILDING PERMITS INVOLVING THE CONSTRUCTION OF NEW RESIDENCE (SINGLE OR MULLTI-FAMILY), RESIDENTIAL ADDITION, ANY ACCESSORY STRUCTURE REQUIRING A BUILDIUG PERMIT AND ANY NONRESIDENTIAL STRUCTURE. THIS CERTIFICATION SHALL NOT APPLY TO LNTERIOR NENOVATIONS (PROVIDED THAT NO EXTERIOR STRUCTURAL WALLS. COLUMNS OR OTHER COMPONETS ARE BEING AFFECTED) AND CERTAIN OTI-IEI2 MINOR BUILDING PERMITS FOR FURTHER ASSISTANCE PLEASE CONTACT THE BUILDING INSPECTION OFFICE AT (772)462-2172 PROJECT NAMEg BAXTER RESIDENCE STREET ADDRESS >i2 r`ii\W".ei � P32MIT NUMBER CUPANCY TYPE SFR CONSTRUCTION TYPE CBS CERTIFICATION STATEMENT I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOAD AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED (PLEASE CHECK OR COMPLETE THE APPROPRIATE BOX) I. FLORIDA BUILDING CODE 2010 EDITION AND ASCE 7-10 2 BUILDING DESIGN IS: ENCLOSED YES PARTIALLY ENCLOSED OPEN BUILDING 3 MEAN ROOF HEIGHTS LESS THAN 15' ROOF PITCH 4/12 INTERNAL PRESSURE COEFICIBNT. +/- 0.18 4. WIDTH OF END ZONES < 4.5' WIND SPEEDS 170 (3 SEC. GUSTS) 5. BUILDING CLASSIFICATION TABLE 1-I. ASCE 7 II FBC TABLE 1604.5 b. WIND EXPOSURE CLASSIFICATIONS D ADJUSTMENT FACTOR FOR EXPOSURE E HEIGHTS 1.47 7. COMPONENTS E CLADDING WIND PRESSURE ON ROOF ZONE I -38,2 ZONE 2 -53.9 ZONE 3 -85.0 8. COMPONENTS E CLADDING WIND PRESSURE ON WALL ZONE 4 SEE 5�ANS PSF 9. COMPONENTS E CLADDING WIND PRESSURE ON OVERHEAD GARAGE DOOR SEE PLANS PSF 10. LOADS FLOOR 40 PSF ROOF/DEAD 25 PSF ROOF/LIVE 30 PSF II. SHEAR WALLS CONSIDERED FOR STRUCTURE? YE$ X NQ____iIF NO, ATTACH EXPLANATION) 12. CONTINUOUS LOAD PATH PROVIDED? YES�VO (IF NO, ATTACH EXPLANATION 13. ARE COMPONANT AND CLADDING DETAILS PROVIDED? YES X NO (IF NO, ATTACH EXPLANATION 14. MINIMUM SOIL BEARING PRESSURE 2500 PRESUMPTIVE 2500 BY TEST' WA PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME .;�:,: -;\ T:.;I� i >'+ � ciii. l , ._. DESIGN FIRM DATE SLCCDV FORMtt 020-00 SEAL REVISED 5/18/09 (CL) MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL.-RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF ,WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC. FOR FULL COMMISION. FLORIDA DESIGN CRITERIA V(ULT) 170 MPH (3 SEC. GUSTS) V(ASD) 132 MPH (3 SEC. GUSTS) EXPOSURE D IMPORTANCE FACTOR I CATEGORY II INTERNAL PRESSURE COEFFICIENT +/- 0.18 ROOF ZONE UP LIFT PRESSURES: ZONE] -38.2 PSF ZONE 2 -53.9 ZONE 3 -85.0 FOR ROOF PITCHS 2/12 THRU 6/12 COMPONENTS E CLADDING PRESSURES EXPOSURE "D" TAG POS.PRESSURE NEG.PRESSURE TAG END ZONE SQ.FT. 46.0 -49.8 -61.6 10 44.0 -47.9 G -57.5 20 C 41.2 -45.1 -51.9 50 39.2 -43.1 I -47.9 100 34.3 -38.1 J -38.1 500 EXPOSURE "Du MULTIPLIER MEAN ROOF HEIGHT FACTOR LESS THAN 15' 1.47 LEFT RIGHT FINISHED FLOOR ZERO TRUSS OVERHANG RIGHT SIDE ZERO LOT LINE FRONT 5V-CRlmp METAL ROOF 12 4 . ZERO TRUSS OVERHANG RIGHT SIDE ZERO LOT LINE L (n W,rn A 40 o rn (nHip�ecoo z aQ Q W�� e-D Lu D Q O fl� > co -:1 m p� ' Q � J w co w o � CV r DC r N O O Wr N �zq0 (nm�U =(Wna0 zrnQ" zif) =)tt la 11-W a W ry X mz z O IL W x J W � Z W w w z p� LLI WN z \-o 0 z J IN I MEL-12Y CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-RY CONSTRUCTION, INC. ELEVATIONS II4" = II -Q AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-12Y CONSTRUCTION, INC. FOR FULL COMMISION. HIGH -STRENGTH LINTEL SCHEDULE PRECAST LINTELS MANUFACTURED BY COST-CRETE Ltt SAFE APPLIED APPLIED GRAVITY GRAVITY UPLIFT BEAM LENGTH TYPE LOAD LOAD L4460 LOAD COMPOSITE LI 2'-10" PRECAST 6113 < 800 < 400 8FI6-IB/IT L2 4'-0" PRECAST 6113 < 800 < 400 8FI6-IB/IT L3 5'-4" PRECAST 5365 < 80 < 400 8FI6-IB/IT 1-4 10'-6" PRECAST 1533 < 800 1183 < 400 8FI6-IB/IT I. ALL BOND BEAM REINFORCING SHALL BE CONTINUOUS AROUND ENTIRE HOUSE PERIMETER INCLUDING CHANGES IN BEAM ELEVATION. ALL SPLICES TO BE A MINIMUM OF 48 BAR DIAMETERS 2. CONCRETE FOR COLUMNS AND BEAMS SHALL HAVE 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS 3. A SINGLE FILLED CELL IS REQUIRED AT EACH SIDE OF EACH OPENING AND AT 6 FEET ON CENTER MIN. 4' O.C. LOWER LEVEL 4. 4 INCH MINIMUM BEARING IS REQUIRED FOR ALL LINTELS WHEN FILLED SOLID W/CONC.. LENGTH = OPEN SPAN PLUS 8 INCHES LI R UP (4) 7.5" � RISERS LIVING ROOM WALL :NT DRYER WID I II LNDRY 1-2'-3" Fo I II ENTRY? 0 7.5" L24 `/� KITCHEN FA I r 22X1p-1 I ATTIC 1 ACCES 3 MASTER `p L3 BEDROOM Q FOUNDATION PLAN 1/4" = 1'-0" PROVIDE BALANCED AIR RETURNS IN ALL UNIT BEDROOMS NOTE: ALL MATERIALS USED BELOW BASE FLOOD ELEVATION MUST BE FLOOD RESISTANT. THIS INCLUDES ALL WALL COVERINGS IN GARAGE, AND MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE TH0121GINAL AND WORK OF MEL-RY CONSTRUCTION, INC. ELSEWHERE IF APPLICABLE.. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-12Y CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-12Y CONSTRUCTION, INC. FOR FULL COMMISION. REF. gm EX GUEST IX , I lul®�m 1mrmlillwil l u BATH z• FLOOR PLAN 1/4" = 1'-0" CONCRETE BLOCK EXTERIOR W/-\LLS WITH TYPICAL STUCCO FINISH p LOAD CALCULATIONS RESIDENTIAL 200 AMP ELECT. PANEL 240- IC 3W CIRC. DESCRIPTION VOLT SIZE WATT SIZE 1,2 AC/AH 240 60 12,000 6 3,4 ANKLESS/ ON DEMAND 240 30 17000 10 5,6 OVEN/RANGE 240 50 12,000 6 7,8 DRYER 240 30 1,000 10 9 LIVING RM. 120 15 1,500 14 10 MASTER BEDRM. 120 15 1,000 14 II BEDRM.2 120 15 1,000 14 12 DINING RM. 120 20 LOCO 12 13 LAUNDRY/WASHER 120 20 1,000 12 14 KITCHEN 120 20 2,000 GFI 15 BATHROOMS 120 20 1,000 GFI 16 SPARE 120 20 1,000 12 FIRST 10,000 = 10,000 REMAIN. 41,500 AT 40%-16,600 51,500 WATTS TOTAL 26,600 AMPS - 26,600 / 240 - 110.8 AMPS LIVING ROOM 183 SO FT ®J , •Z� TYPICAL ELECTRIC RISER 200 FLUS14 P. 1PH.. NOT TO SCALE 200 W/R 0 q� E zoo AMP AMP (30 CIRC) MAIN DISCONNECT PANE ELECTRIC METER 11 A A 1 " 30AMP F1�9 60 SO FT o O F— ATTIC ENTRY LAccesJ 16 soft MASTER BEDROOM 125 SO FT wic (3) UVO THHN-CU IN 7 CONDUIT 342/C.U. IN 7 DIA COND.— u4 SOLID OR STRANDED CU. GROUNDED TO (2*5 REINFORCING BARS AT FOUNDATION BASE 2 Ql—w DS • 6' APART #vO � UFER GROUND REQUIRED m KITCHEN 125 SO FT F Lv- I I----r--� I I I ISL --� ❑ L-- j n 12ANGE E \/ MICRO IA 4i- = REF. 00 GUEST BEDROOM 90 SO FT FAJW MASTER BATH 54 SO FT HVAC PLAN 114" = 1'-0" PROVIDE BALANCED AIR 2ETL12NS IN ALL UNIT BEDROOMS I ELECTRICAL LEGEND P 1/2 ON SWITCH 110 V. RECEPTACLE 110 V. RECEPTACLE 220 V. SPECIAL PURPOSE OUTLET El FLOOR OUTLET 4 RECESSED LIGHT OWNER CHOICE WALL MOUNT LIGHT FIXTURE PENDANT LIGHT IIOV FOR FIXTURE OWNER CHOICE RECESSED LIGHT ® EXHAUST FANILITE COMBINATION ® EXHAUST FAN '.. CEILING FAN ( y�5( CEILING FAN W/ LIGHT $ SINGLE POLE SWITCH $3 DOUBLE POLE SWITCH [=H 220 V. DISCONNECT ® SMOKE DETECTOR ® CARBON MONOXIDE ALARM ROOD LIGHT DOOR OPENER ® FLUORESCENT LIGHT ® FLUORESCENT LIGHT ME& --I ELECTRICAL PANE. ELECTRICAL METER TELEVISION JACK (CABLE) d PHONE JACK O DOORBELL/GARAGE DOOR BUTTON CHIMES ® SPEAKERS GFI GROUND FAULT INTERRUPT A CARBON MONOXIDE ALARM SHALL BE INSTALLED IN ACCORDANCE WITH F.A.C. RULE 9B-3.0472 WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING PURPOSES, MOTION/ LIGHT SENS- ALWAYS METE F.P.L. LOC) MOTI LIGH" LIGHT SENS. ALWAYS HOT ELECTRICAL PLAN 114" = 1'-0" PER NEC 2008 C DISCONNECT WP uJ UJ w� Him Qo(�(n z LL°�m CO In Z � N 11=U) (V 0 W � O W r �aON �t0 U) 0 UVLLq =�~0 DC a Lo O 1� d `•; J Ill U) 0 W W In ~ W z p� W WN Z \O Q Z J Q) O MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-12Y CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC. FOR FULL COMMISION. 5 BEARING NEADEQ SCHEDULE SIZE SPECIES NAILING OPENING JACKS FULL STUD (2)2X6 SPF STAGGERED 12"OC 16D UP TO 3'-II (1) (U (2)2X8 HEMP FIR STAGGERED 12"OC 16D 4' TO 6' (1) (D (2)2XIO HEMP FIR STAGGERED 12"OC 16D 6-1 TO 8'-6 (2) (D (2)2XI2 HEMP FIR STAGGERED 8"OC 16D 8'-7 TO 16' (2) (2) NON -BEARING NEADEQ SCHEDULE SIZE SPECIES NAILING OPENING JACKS FULL STUD (2)2X4 SPF STAGGERED 12"OC 16D UP TO 3'-II (D (D (2)2X:6 SPF STAGGERED 12'OC 16D 4' TO 9'-8 (U (U - k4EADEP2 `--�-12" 2"P I' MIN FROM EDGE 4AX �78^ INDOW UNIT TAPER ADD (1) u5 SILL OVER 4' LNG. j FORMED E POURED CONC. SILL CONC.BLK.EXT. • ALL W/1135 VERT - - AS IN FLOOR PLAN -, - CONC. WINDOW SILL DETAIL 12" MAX PLYWOOD 'IMP METAL PANEL .LT FILLED I/2� I'XT P.T. DRYWALL FIR STRIP 2"X8' P.T. DOOR BUCK ATTACHED W/I/4' X 4' TAPCONSo6' EA.END. E 018' O.C(SNGLLEAF) E olT O.C. 081-LEAF) BRICK SWING DOORJAMB ATTACHED W1#10 X 3' WOOD SCREWS o6' EA.END E 18' O.C.(SNGL.LEAF) E 1T O.C.0131-LEAF) ;TERIOR SWING DOOR ATTACHMEN- I'X2' P.T. I'X2' P.T. FURRING FU2RING 1/7 DRYWALL I'X6' P.T. WINDOW BUCK �TTACHED W/1-1/2' 'T / NAILS o 18'O.C. VERT WINDOW FRAME ATTACHED TO CONC, BLOCK TH12U WOOD TYPICAL WINDOW BUCK W/l/4' X 2-L STUCCO TAPCONS, FILL ALL HOLES MIN. EMBED 1-1/4' WINDOW ATTACHM 316 CONT. BEAD OF CAULK (BACK BEDDING) BEHIND BUC TO PREVENT LIQUID PASSAGE1 SET FLANGE IN COW. BED OF CAULK ACROSS. ENTIRE FACE OF BUCK PE2IMETER CAULK ATTACH P.T. BUCKS W/.099 X 1-I/2' NAILS AT 17 O.C. jl/4• MAX SHIM P.T. IX WOOD BUCK TO —EXTEND BEYOND INTERIOR FACE OF WINDOW OR S.G.D. /2' DRYWALL TTACH AS PER MAN JF. 20DUCT APPROVALS . ALUM.WINDOW S.G.D. JAMB TYPICAL WINDOW E S.G.D. JAMB DETAIL AT C.B.S. WALL NOTE, GLNNABLE SEALANTS SHALL COMPLY WITH ASTM C 920 CLASS 25 GRADE N5 OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION 3/6 CONT. BEAD OF CAULK (BACK BEDDING) BEHIND SHI TO PREVIBNT LIQUID PASSAGE 1/4• (MAX) SHI TYP.ALUM.WINDOW SET FLANGE IN CONT, BED OF CAULK A WINDOW ENTIRE FACE OF SHIM SILL CORROSIVE RESISTANT TAPCON' PE12IMETE12 CAULK CONO. SCREWS INSTALLED AS SPECIFIED CRE"C� IN WINDOW MANLF. PRODUCT APPROVAL WALL W/In5 VERT AS IN FLOOR PLAN TYPICAL PRECAST CONC. SILL DETAIL NOTE- GLMABLE SEALANTS SHALL COMPLY WITH ASTM C 920 CLASS 25 GRADE N5 OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION R703.8 FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH, APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 1.1 THE FENESTRATION MANUFACTURER'S WRITTEN FLASHING INSTRUCTIONS. 1.2 THE FLASHING MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 1.3 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, OR 'IMP METAL FMA/WDMA 250. PANEL 1.4 IN ACCORDANCE WITH THE FLASHING METHOD OF A REGISTERED DESIGN PROFESSIONAL. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. PLYWOOD I. AT THE EAVE, RAKE,AND RIDGE, FASTENERS SHALL BE LOCATED NOT MORE THAN 3" AWAY FROM THE PANEL END. 2. THE LEADING SIDE EDGE OF THE PANEL SHOULD BE THE SIDE WITH THE ANTI -SIPHON GROOVE, EACH PANEL SIDE WILL OVERLAP THIS CHANNEL TO PROVIDE A CAPILLARY BRAKE. 3. u9-15 X 1-1/2" SELF DRILLING CORROSIAN RESISTANT FASTENERS W/ SELF SEALING WASHERS AT 12" O.C. AND AT 12" O.C. IN THE CENTER OF THE PANEL AT THE FIELD PERPENDICULAR TO THE ROOF SLOPE= ON THE HIGH POINTS OF THE PANEL RIBSA. THE PANEL'S WIDTH FASTENER`; SHALL BE SPACED AT 12' O.C. TO THE CENTER RIB, THEN IT TO THE NEXT, PERPENDICULAR TO THE SLOPE, THROUGH THE OVERLAPPING PANEL. THE FLAT AREA OF THE PANEL AS SHOWN IN THE DETAILS HEREIN. 5. THE PANELS FASTENING PATTERN AT THE INTERIOR OF THE PANEL, SHALL BE IN ROWS SPACED 12' 0.0, RUNNING PARALLEL TO THE SLOPE OF THE ROOF. FL u6931-RI TYPICAL W SEE WALL DET/ TYPICAL SOFFIT DETAIL N.T.S. AL DRIP FLASHING " P,T. DRIP EDGE PRIMED R.S. .IA CONTRACTOR TO USE 7/8" STUCCO OVER 3/8" HI RIBBED PAPER BACKED METAL LATH OVER "TYVEK" W/1.5" NAILS W/3/8" DIA.HEADS PER F.B.C. 2514.3.5, THE CONTRACTOR SHALL INSTALL 6' X 24" SOFFIT VENTS o 8'-(y O.C. PNEUMATIC F=ASTNEQ SCHEDULE I.) PNEUMATIC FASTNERS SHALL BE 'HILTI" COIL NAILS, TYPE CRF 1120. 1-1/2' LONG BY .120 DIAMETER UNLESS OTHERWISE NOTED. 2.) FASTNERS OF EQUAL LENGTH AND DIAMETER MAY BE SUBSTITUTED FOR THOSE SPECIFIED. LOCATION NAIL SIZE MANUF. MODEL tt SPACING/ REMARKS PLYWOOD WALL SHEATHING 2-3/8' X .113 (34 DEG.) PRUDENTIAL BUILDING MAT. SP812MS SEE DIAPHRAM SCHEDULE PLYWOOD FLOOR 2-3/8" X .113 (34 DEG.) PRUDENTIAL SP,8RMS SEE DIAPHRAM SCHEDULE SHEATHING BUILDING MAT. PLYWOOD ROOF 8D COMMON COATED PRUDENTIAL SEE DIAPHRAM SCHEDULE SHEATHING BUILDING MAT. I" X T FURRING .099 X 1-1/2" SM INTERNATIONAL 422428 16" O.C. STRIPS STAPLE WINDOW BUCKS .120 X 1-1/7 HILTI 12' O.C. GARAGE DOOR 1/2' X 5-1/2" RAMSET/REDHEAD 24" O.C. VERTICALLY BUCKS DOOR BUCKS 1/4' X 2-1/2' INTERNATIONAL 8" O.C. TAPCONS STAPLE SLIDING GLASS .120 X 1-1/2' HILTI 12" O.C. DOOR BUCKS ROOF BASE 120 X I" CENCO HJI5ATA 12' O.C. AT HEAD LAPS AND EVE EDGES SHEET GALVANIZED 24' O.C. AT EDGE OF VALLEY SHEETS DIAPHRAM SCHEDULE PANEL FRAMING DIAPHRAM ZONE I ZONE 2 ZONE 3 EDGE INTER. EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING BOUNDERIES REMARKS IOD, IOD, IOD, IOD, IOD, IOD, IOD, BLOCKING ROOF RATED SHEATHING APA R 19/32" 24' O.C. MAX. 6" O 6" O.C. 6' O.C. 6" O.C. 6' O.C. 4" O.C. 4" O.C. AS SHOWN EXPOSURE I, OR EQUAL .C. SPAN RATING 40/20 NOTE ALL ROOFING NAILS TO BE RING SHANK I NOTE TO GENERAL CONTRACTOR: ALL CONNECTIONS IN CONTACT WITH ACID MATERIAL SHALL BE HOT DIPPED GALVANIZED MINIMUM. NOTE TO BUILDER: BUILDER SHALL COORDINATE AND REVIEW ALL FINAL ARCHITECTURAL DRAWINGS WITH TRUSS MANUFACTURERS DRAWINGS BEFORE TRUSS MANUFA(TURERS TRUSS ENGINEERING PACKAGES AND ACTUAL TRUSSES ARE PRODUCED. (2) 5/8" D. WEDGE ANCHOR MOUNTING PLATE TO BILK. WALL BOTH SIDES 1/4" X 4" ALUM MOUNTING PLATE W/1/4" FILET WELDS ALL EDGES 1/4" X 3" FLAT STRAP, BOT SIDES OF PLATFORM , 36" X 36"X 1/4" ALUM. AG PLATFORM ABOVE HOOD OF CAR 1/4" FILET WELDS ALL EDGES TYPICAL TYPICAL WALL SEE WALL DETAILS 5/8" D. WEDGE ANCHOR AT 6" O.C., PLATFORM TO BLK. WALL 1ETAL DRIP FLASHING -I"X2" P.T. DRIP EDGE "X6" PRIMED R.S. FACIA ZERO OVERHANG DETAIL N.T.S. R702.4.1 GENERAL. CERAMIC TILE SURFACES SHALL BE INSTALLED IN ACCORDANCE WITH ANSI A108.1, A108.4, A108.5, A108.6, A108.11, AI18.1, AI18.3, A136.I AND A137.1. R702.4.2 CEMENT, FIBER -CEMENT AND GLASS MAT GYPSUM BACKERS. CEMENT, ' FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325 OR C 1178 AND INSTALLED WITH 1-1/4, WAFER HEAD, RUST RESISTANT DRILL TYPICAL OR SHARP POINT SCREWS AT 8" O.C. IN XTERIOR FIELD AND 4" O.C. AT EDGES, BACKING FOR WALL WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS, ON MIN. 2" X 4" WOOD FRAMING. FIN.FL. A.F.E. NAVD88 a ALUMINUM AC MOUNTING PLATFORM AT FINISHED FLOOR ELEVATION MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC. FOR FULL COMMISION. ATTACHMENT TO ALUMINUM DECK AS PER AC MANUF. CONDENSER UNIT ALUMINUM AC PLATFORM, SEE - DETAIL THIS PAGE COMPRESSOR ATTACHMENT DETAIL N.T.S. W w co O >� Q ��J -i Z Z(7LL Um Q9QODI N Q Lu a � Z 0, 0 Q O IL > co m J I Q w z L� (n c I N (4 0 0- O W J>� 3:zd0 Wm�U U�zW.1 LLJ _ n a (0 � LO � a 0 Iq �_ W Lu U J I— W () Z W W ry W Z pj W N Z �O 5 5 *BUILDER'S WARNING* * THIS IS A PLACEMENT PLAN FOR ENGINEERED * SEE FINAL ENGINEERING SHEETS FOR THE COMPONENTS AS DEFINED BY WTCA 1-1995. STRUCTURAL DATA, NUMBER OF GIRDER AND DIAPHRAGMS HAVE NOT BEEN ANALYZED BY TRUSS PLIES AND THE CONNECTION INFORMATION. EAST COAST TRUSS. * OUR DESIGN DEPARTMENT MUST APPROVE �c FOR ERECTION AND INSTALLATION OF TRUSSES ALTERATIONS AND/OR REPAIRS TO TRUSSES FOLLOW INSTRUCTIONS ON THE BCSI—B1 SUMMARY IN ADVANCE. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS * BACK CHARGES WILL NOT BE ACCEPTED �c BRACING UNLESS OUR DEPARTMENT APPROVES 1.) FOR ERECTION BRACING FOLLOW INSTRUCTIONS * THEM IN ADVANCEGN ALL HANGERS ARE SIMPSON STRONG —TIE ON THE BCSI—B1 SUMMARY SHEETS. 2.) PERMANENT BRACING FOR THE STRUCTURE UNLESS OTHERWISE NOTED. INSTALL HANGERS IS THE RESPONSIBILITY OF OTHERS. ACCORDING TO THE CURRENT SIMPSON 3.) INSTALL WEB BRACING AS STATED ON SEALED STRONG —TIE CATALOG. ENGINEERED TRUSS DRAWINGS. WARNING ALL BEARING POINTS MUST BE INSTALLED PRIOR TO INSTALLING ANY TRUSSES. FAILURE TO DO SO MAY RESULT IN DAMAGED TRUSSES AND WILL VOID ANY WARRANTIES. BRG POINT "A" TRUSS CONNECTOR SCHEDULE Baxter residence TRUSS CONNECTOR CONNECTOR CONNECTOR TRUSS I.D. UPLIFT MFG QTY TO USE A07G 1971 S 2 EACH END HETA20 CONNECTOR UPLIFT 2035 FASTENERS PER STRAP 10-10d x 1-1/2 Truss to Concrete < 1725 S 1 HETA20 1805 10-10d x 1-1/2 Truss to Wood < 625 U — 1 RT7A 650 10-8d x 1-1/2 Connector Mfg U=USP, S=Simpson SIGNATURE ACKNOWLEDGES: Having used the Truss Loads (Provided by the Truss Manufacturer) for Design of Pertinent Components. No Responsibility is Hereby Assumed for the Dimensioning, Detailing, Fabrication Nor Installation of This Truss System. APPROVED BY: JOHN H. CPESWELL, PE TITLE: ENGINEER OF PECOI2D APPROVAL DATE: J W W 2 U.'ICD M 811 PLUMB CUT CANTILEVER TYR END DETAIL TRUSS PLACEMENT PLAN MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC. FOR FULL COMMISION. 0 Q 75 HANGER SCHEDULE ALL 2x HANGERS HUS26 EXCEPT ARE SIMPSON AS NOTED HUS26 OTY = 0 HIPCATS 12 CITY = 0 ENGINEERED 'RUSS SYSTEMS 5285 ST. LUCIE BLVD. FT. PIERCE FL. 34946 OFFICE:(772)466-2480 FAX:(772)466-5336 CUSTOMER: Mel—Ry Construction JOB NAME: Baxter Residence ADDRESS: 10701 S. Ocean Drive, #612 CITY/COUNTY: Jensen Beach/St. Lucie JOB#: 26768 MODEL: - ELE _ W/OPT W/OPT GARAGE- - SQ FT DATE: 05/02/2014 In accordance with the Florida Administrative Code 61 G15S-31.003 (3) (c), EAST COAST TRUSS is the "Truss Design Engineer". Trusses are des'gned in accordance with the Florida Building Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representative acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the projt=ct indicated on this drawing. The customer acknowledges that he/she accepts financial responsible for any repair engineering and labor required due to errors other than those of EAST COAST TRUSS signed date CODE: FBC 201O/TP12007 ASCE 7-10 DESIGN CRITERIA — C & C OCCUPANCY CATEGORY: II EXPOSURE CATEGORY = D MWF SPEED: 170 M.P.H. BUILDING TYPE: ENCLOSED MEAN HEIGHT: 15 FEET TRUSS SPACING 24" O.C. EXCEPT AS NOTED Designed w/Lumber Values effective 6-1-13 GRAVITY LOADS ROOF TC LIVE: 30psf TC DEAD: 15psf BC LIVE: 10psf* BC DEAD: 10psf DUR FACTOR: 1.33 LOADS PER FBC & FRC * NON —CONCURRENT BC LL 10psf CONCURRENT 13C STORAGE LL 20psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS & CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD DL = DEAD LOAD # = POUNDS psf = POUNDS PER SQUARE FOOT CAUTION: SPANS GREATER THAN 30'-C MUST BE SET WITH A SPREADER BAR. THE SPREADER BAR SHOULD BE AT LEAST 1 /2 TO 2/3 IN LENGTH AS THE SPAN OF THE TRUSS BEING SET. REFER TO BCSI-131 FOR COMPLETE ERECTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER NOTE: TRUSSES DO NOT SUPPORT ANY PLANT SHELVES (1/4" if plotted 18x24) DESIGNED BY: NW 0 W Q H V) Cf ) (n W J Z W V) V) w N H O m n O O CL n W