HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BAXTER RESIDENCE
Builder Name:
Street 612 VENTURE ST
Permit Office:
'fity, State, Zip: FORT PIERCE, FL,
Permit Number:
_-.- owner.
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types(1136.0 soft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - &t insul, Exterior
R=4.1 1136.00 ft'
b. N/A
R= fe
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft,
5. Is this a worst case? No
10. Ceiling Types (828.0 soft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 828.00 ft'
6. Conditioned floor area above grade (ftz) 828
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= fN
11. Ducts
R ft2
7. Windows(117.0 sgft.) Description Area
a. Sup: Attic, Ret: Atfic, /'.H: Main
6 115
a. U-Factor. Sgl, U=1.07 117.00 ft'
SHGC: SHGC=0.50
b. U-Factor. N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.0 SEER:16.00
c. U-Factor. NIA ft'
SHGC:%
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth;' 8.000 ft.
Area Weighted Average SHGC: 0.500:
14. Hot water systems
8. Floor Types (828.0 sq(t) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 828.00 ftz
b. Conservation features
EF: 0.920
b. N/A R= fN
None
c. N/A R= ft'
15. Credits
Pstat
Total Proposed Modified Loads: 20.38
Glass/Floor Area: 0.141
PASS
Total Standard Reference Loads: 25.43
I hereby certify that the plans and specifications covered by
Review of the plans and
S743,
this calculation are in compliance with the Florida Energy
Code. --�
specifications covered by ittis
calculation indicates com!:!Ance
0,-i14E
{
j ; 4
k . E--
with the Florida Energy Cade.,-•:,,�ifr•�•:"
J , �.y; �, p
PREPAR Q B
DATE:_
Before construction is completed
this building will be inspected for
compliance with Section �:53.908
u�
i_c -
I hereby certify that this building, as design is in compliance
Florida Statutes.
with the Florida Energy Code.
G' WE �v
OWNER] G T`///�
BUILDINGOFFICIAL:
DATE:
DATE:
6/2/2014 2:44 PM EnergyGaugeO USA - FlaRes2010 Section 405A.1 Compliant Sc?aware Page i of 5
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
ermit Office:
urisdiction:
amity Type:
ewlEAsting:
Comment
BAXTER RESIDENCE
User ''
1
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 828
Total Stories: 1
Worst Case: No
Rotate Angle. 0
Cross Ventilation: Yes
Whole House Fan: No
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street
County:
City, State, Zip:
Street Address
612 VENTURE ST
ST. LUCIE
FORT PIERCE,
FL ,
CLIMATE
v Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST_LUCIE CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
,Blocky...
828 6624
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
828 6624 Yes 1
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Siab-On-Grade Edge Insulatio Main 145 ft 0
828 fe
_
0 0 1
ROOF
/
v #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 897 ft' 0 ft' Medium
0.96
No 0.9
No 0 22.6
ATTIC
/
V #
,Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
828 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
i
Under Attic (Vented)
Main 30 828 fP
0.11
Wood
6/2/2014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
. Omt
Adjacent
In Wall
Type
Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1 N
Exterior Concrete Block - Ext Insul
Main
4.0999 22 8
176 ft'
0
0 0.75
0
2 E
Exterior Concrete Block - Ext Insul
Main
4.0999 49 8
392 W
0
0 0.75
0
_ 3 S
Exterior Concrete Block - Ext Insul
Main
4.0999 49 8
392 ft'
0
0 0.75
0
_ 4 W
Exterior Concrete Block - Ext Insul
Main
4.0999 22 8
176 ft'
0
0 0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In Ft In
1
N
Insulated Main
None
0.4 3
6
8
20 ft'
2
W
Insulated Main
None
0.4 3
6
8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame
Panes NFRC
U-Factor SHGC
Area Depth Separation Int Shade
Screening
1
N 1 Metal
Single (Clear)
Yes
1.07 0.5
45 ft' 8 ft 0 in
6 ft 0 in
None
None
2
E 2 Metal
Single (Clear)
Yes
1.07 0.5
6 fF B ft 0 in
6 ft 0 in
None
None
3
E 2 Metal
Single (Clear)
Yes
1.07 0.5
4 ft' 8 ft 0 in
6 ft 0 in
None
None
4
E 2 Metal
Single (Clear)
Yes
1.07 0.5
15 ft' 8 ft 0 in
6 ft 0 in
None
None
5
S 3 Metal
Single (Clear)
Yes
1.07 0.5
8 ft' 8 It 0 in
6 ft 0 in
Nate
None
6
S 3 Metal
Single (Clear)
Yes
1.07 0.5
15 ft' 8 ft 0 in
6 ft 0 in
None
None
7
W 4 Metal
Single (Clear)
Yes
1.07 0.5
4 ft' 8 ft 0 in
6 It 0 in
None
None
B
W 4 Metal
Single (Clear)
Yes
1.07 0.5
4 ft' 8 ft 0 in
6 It 0 in
None
None
9
W 4 Metal
Single (Clear)
Yes
1.07 0.5
16 ft' 8 ft 0 In
6 ft 0 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 W holehouse Best Guess
0.000500
1085.9 59.616 112.11 0.3650
9.8363
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COP: 1
17 kBtulhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR
Block
Ducts
1
Central Unit
None
SEER: 16
18 kBtu/hr 540 cfm 0.75
1
sys#1
[J
6=014 2:44 PM EnergyGauge® USA - FfaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Exterior
0.92 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft'
DUCTS
/
— Supply —
— Return —
Air `
Percent
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
CFM 25
Leakage QN
RLF
Heat Cool
1
Attic
6 115 f?
Attic
15 fN Default Leakage
Main
(Default) (Default) %
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Heatig an
Feb
Feb
Mar
Mar
f
Apr
APr f
Jun Jul
May Jun Jul
Ma ri
X Au
f Aug
Se
S P
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
(Xj
A r [
Ma Jun [ Jul
[ Au
[ Se
[X
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours -
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78 78 78
78
78
78
80
80
80
80
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78 78 78
78 78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66 66 68
68 68
68
68
68
68
68
68
.
68
68
68
68
68
66
66
Healing (WEH)
AM
PM
66
68
66
68
66
68
66 66 68
68
68
68
68
68
68
68
68 68
68
68
68
68
66
66
i
6/2/2014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Methnd
ADDRESS: 612 VENTURE ST PERMIT #:
FORT PIERCE, FL,
r,
r
`MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
L
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
controls
403.1
At least one thermostat shall be provided for each separate heating and
cooling system. Where forced -air fumace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
ventilation
403.5
Homes -designed to operate at positive pressure or with mechanical
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
8 Spas
403.9
Pool pumps and pool pump motors with a total.horsepower (HP) of =1
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or'a liquid cover or
other means proven to reduce heat loss except if 70% 4 heat from
site -recovered energy. Off/timer switch required. Gas heaiers minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
equipment
403.E
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
occasion cooling or heating capacity requires separate system or
variable capacity. system. Electric heat >10kW roust be divided into two
or e stages.
Ceilings/knee walls
405.2.1
�R-lpace permitting.
6/212014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5