Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BAXTER RESIDENCE Builder Name: Street 612 VENTURE ST Permit Office: 'fity, State, Zip: FORT PIERCE, FL, Permit Number: _-.- owner. Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types(1136.0 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - &t insul, Exterior R=4.1 1136.00 ft' b. N/A R= fe 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. N/A R= ft, 5. Is this a worst case? No 10. Ceiling Types (828.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 828.00 ft' 6. Conditioned floor area above grade (ftz) 828 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= fN 11. Ducts R ft2 7. Windows(117.0 sgft.) Description Area a. Sup: Attic, Ret: Atfic, /'.H: Main 6 115 a. U-Factor. Sgl, U=1.07 117.00 ft' SHGC: SHGC=0.50 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:16.00 c. U-Factor. NIA ft' SHGC:% 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth;' 8.000 ft. Area Weighted Average SHGC: 0.500: 14. Hot water systems 8. Floor Types (828.0 sq(t) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 828.00 ftz b. Conservation features EF: 0.920 b. N/A R= fN None c. N/A R= ft' 15. Credits Pstat Total Proposed Modified Loads: 20.38 Glass/Floor Area: 0.141 PASS Total Standard Reference Loads: 25.43 I hereby certify that the plans and specifications covered by Review of the plans and S743, this calculation are in compliance with the Florida Energy Code. --� specifications covered by ittis calculation indicates com!:!Ance 0,-i14E { j ; 4 k . E-- with the Florida Energy Cade.,-•:,,�ifr•�•:" J , �.y; �, p PREPAR Q B DATE:_ Before construction is completed this building will be inspected for compliance with Section �:53.908 u� i_c - I hereby certify that this building, as design is in compliance Florida Statutes. with the Florida Energy Code. G' WE �v OWNER] G T`///� BUILDINGOFFICIAL: DATE: DATE: 6/2/2014 2:44 PM EnergyGaugeO USA - FlaRes2010 Section 405A.1 Compliant Sc?aware Page i of 5 PROJECT Title: Building Type: Owner: # of Units: Builder Name: ermit Office: urisdiction: amity Type: ewlEAsting: Comment BAXTER RESIDENCE User '' 1 Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 828 Total Stories: 1 Worst Case: No Rotate Angle. 0 Cross Ventilation: Yes Whole House Fan: No Address Type: Lot # Block/SubDivision: PlatBook: Street County: City, State, Zip: Street Address 612 VENTURE ST ST. LUCIE FORT PIERCE, FL , CLIMATE v Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 ,Blocky... 828 6624 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 828 6624 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Siab-On-Grade Edge Insulatio Main 145 ft 0 828 fe _ 0 0 1 ROOF / v # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 897 ft' 0 ft' Medium 0.96 No 0.9 No 0 22.6 ATTIC / V # ,Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 828 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 i Under Attic (Vented) Main 30 828 fP 0.11 Wood 6/2/2014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS . Omt Adjacent In Wall Type Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext Insul Main 4.0999 22 8 176 ft' 0 0 0.75 0 2 E Exterior Concrete Block - Ext Insul Main 4.0999 49 8 392 W 0 0 0.75 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.0999 49 8 392 ft' 0 0 0.75 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4.0999 22 8 176 ft' 0 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None 0.4 3 6 8 20 ft' 2 W Insulated Main None 0.4 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Clear) Yes 1.07 0.5 45 ft' 8 ft 0 in 6 ft 0 in None None 2 E 2 Metal Single (Clear) Yes 1.07 0.5 6 fF B ft 0 in 6 ft 0 in None None 3 E 2 Metal Single (Clear) Yes 1.07 0.5 4 ft' 8 ft 0 in 6 ft 0 in None None 4 E 2 Metal Single (Clear) Yes 1.07 0.5 15 ft' 8 ft 0 in 6 ft 0 in None None 5 S 3 Metal Single (Clear) Yes 1.07 0.5 8 ft' 8 It 0 in 6 ft 0 in Nate None 6 S 3 Metal Single (Clear) Yes 1.07 0.5 15 ft' 8 ft 0 in 6 ft 0 in None None 7 W 4 Metal Single (Clear) Yes 1.07 0.5 4 ft' 8 ft 0 in 6 It 0 in None None B W 4 Metal Single (Clear) Yes 1.07 0.5 4 ft' 8 ft 0 in 6 It 0 in None None 9 W 4 Metal Single (Clear) Yes 1.07 0.5 16 ft' 8 ft 0 In 6 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Best Guess 0.000500 1085.9 59.616 112.11 0.3650 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 17 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 18 kBtu/hr 540 cfm 0.75 1 sys#1 [J 6=014 2:44 PM EnergyGauge® USA - FfaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.92 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — — Return — Air ` Percent HVAC # V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 115 f? Attic 15 fN Default Leakage Main (Default) (Default) % 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Heatig an Feb Feb Mar Mar f Apr APr f Jun Jul May Jun Jul Ma ri X Au f Aug Se S P Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar (Xj A r [ Ma Jun [ Jul [ Au [ Se [X Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours - Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 . 68 68 68 68 68 66 66 Healing (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 i 6/2/2014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Methnd ADDRESS: 612 VENTURE ST PERMIT #: FORT PIERCE, FL, r, r `MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. L COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & controls 403.1 At least one thermostat shall be provided for each separate heating and cooling system. Where forced -air fumace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical ventilation 403.5 Homes -designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 8 Spas 403.9 Pool pumps and pool pump motors with a total.horsepower (HP) of =1 HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or'a liquid cover or other means proven to reduce heat loss except if 70% 4 heat from site -recovered energy. Off/timer switch required. Gas heaiers minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating equipment 403.E Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity. system. Electric heat >10kW roust be divided into two or e stages. Ceilings/knee walls 405.2.1 �R-lpace permitting. 6/212014 2:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5