HomeMy WebLinkAboutSet-Up ManualSET-UP MANUAL JA ;OBS N HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-113 8 r•i p NM Am NOTICE These specifications and drawing are original, proprietary, and confidential materials of Jacobsen Manufacturing,_ Inc.. Such,materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. SU-00-0000 REV-01 /13 MANUFACTURED HOME SET-UP *SITE PREPARATION (A.) BLOCKING (B.) LEVELING (C.) ASSEMBLY AND CLOSE-UP *TIEDOWNS (SEE SET-UP MANUAL ADDENDUM) *ELECTRICAL CONNECTIONS *PLUMBING CONNECTIONS *A.C. CONNECTIONS *ON SITE VENT CONNECTIONS SITE PREPARATION *MISCELLANEOUS DETAILS IF YOU ARE GOING TO LIVE IN A PARK, YOUR HOME SITE WILL BE READY OR BE PREPARED FOR YOUR HOME. IF YOU INTEND TO INSTALL YOUR HOME ON YOUR OWN LOT (NOT IN A PARK), SOME SITE PREPARATION WILL BE NECESSARY. ALL DRAINAGE (AT THE INSTALLATION SITE) MUST BE DIVERTED AWAY FROM THE HOME AND MUST SLOPE A MINIMUM OF 1/2" PER FOOT AWAY FROM THE FOUNDATION OR SKIRTING FOR THE FIRST 10'. THE SITE MUST BE GRADED TO PROVIDE FOR STORM RUN-OFF. SPECIAL CARE MUST BE TAKEN WITH THE AREA DIRECTLY BELOW YOUR HOME TO PREVENT WATER FROM PONDING AND/OR PUDDLING UNDER YOUR HOME AND SUPPORTS. IF THE SPACE UNDER THE HOME IS TO BE ENCLOSED WITH SKIRTING OR OTHER MATERIALS, A VAPOR RETARDER (I.E. POLY...) MUST BE INSTALLED TO COVER THE GROUND UNDER THE HOME (SHALL BE 6 MIL. AND ALL SEAMS TO OVERLAP 12" MIN.) REPAIR ANY TEARS OR VOIDS IN THE RETARDER BY PATCHING WITH LIKE MATERIAL, MAINTAINING A MINIMUM 12" OVERLAP AND SEALING JOINTS WITH DUCT TAPE OR MASTIC. PIER SUPPORTS MUST BE PLACED ON UNDISTURBED SOIL (ALL GRASS AND ORGANIC MATERIAL MUST BE REMOVED) OR FILL WHICH IS COMPACTED OR FULLY SETTLED (SEE SU-4.1, DETAIL 'A' AND DETAIL 'B'). IN AREAS THAT ARE SUSCEPTIBLE TO FROST, PIER SUPPORTS MUST BE BELOW THE FROST LINE. OPTIONAL: PIERS MAY BE PLACED ON CONCRETE RIBBONS 6" X 16" X LENGTH OF HOME MINUS 18", REINFORCED WITH WELDED WIRE MESH. (A.) BLOCKING UNLIKE A STANDARD HOUSE, YOUR MANUFACTURED HOUSE DOES NOT NEED A FOUNDATION TO SUPPORT IT COMPLETELY AROUND ITS PERIMETER. THE STEEL FRAME OR CHASSIS USED FOR TRANSPORTATION ALSO SUPPORTS THE HOME AT ITS HOME SITE. THE STEEL FRAME MUST BE SUPPORTED (SEE SU-01-0003 & 0004) TO PREVENT YOUR HOME FROM SAGGING, AND TO KEEP IT LEVEL. NOTE: ADDITIONAL PIERS ARE REQUIRED AT ALL RIDGE BEAM SUPPORT COLUMNS (EXCEPT AT THE FRAME HEADER), SHEARWALLS, AND AROUND THE PERIMETER OF YOUR HOME. CHECK FOR THE APPROPRIATE DETAILS FOUND IN THIS AND THE SET-UP MANUAL ADDENDUM FOR SPECIFICS FOR EACH TYPE OF ADDITIONAL BLOCKING REQUIRED. SPECIFIC BLOCKING LABELS ARE FOUND ON THE EXTERIOR SIDES OF YOUR HOME. MAXIMUM HEIGHT OF A PIER IS DETERMINED BY THE TYPE OF PIER USED, CHECK THE APPROPRIATE DETAILS FOR THE PROPER CONSTRUCTION OF EACH DIFFERENT TYPE OF PIER. (ALSO SEE TIE -DOWN REQUIREMENTS TO DETERMINE MAXIMUM HEIGHT FROM GROUND.) ALL SUPPORTING STRUCTURES NOT LISTED OR SHOWN IN THIS MANUAL OR SET-UP MANUAL ADDENDUM MUST BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER. (B.) LEVELING PROPER BLOCKING SEQUENCE IS ESSENTIAL IN THE LEVELING OF YOUR HOME. (SEE BLOCKING DETAILS ON SU-01-0002 ,0003, & 0004) FOR THE RECOMMENDED BLOCKING SEQUENCE, TAKING CARE TO CHECK YOUR LEVEL BETWEEN EACH STEP AND SUPPORT. RECOMMENDED LEVEL IS A 48" CARPENTER'S LEVEL. (SEE ACCEPTABLE LEVELING GUIDE BELOW) BUBBLE HAIRLINES CARPENTER'S LEVEL 1/8A IS MAXIMUM ACCEPTABLE SPECIAL NOTE FOR ALL HOMES SET IN FLORIDA CHECK FLORIDA STATUTE 15C FOR ANY LIMITAIONS THAT MAY AFFECT THESE INSTRUCTIONS. NOTICE: DRAWN BY: DATE REV. UTTER: ❑❑❑❑ JAC 0 B S E N HOMES THESE SPECIFICATIONS AND DRAWINGS ARE 0. A. 11-21-06 ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: Q ❑„❑ MATERIALS OF JACOBSEN MANUFACTURING u P.O. BOX 368 INC. SUCH MATERIALS ARE FRONDED TO THE MANUFACTURED HOME SET-UP ❑❑❑❑ SAFETY HONEHARBOR,) FLORIDA 384695 �T �F A AND SECT f s� MuST BEHEM DRAWING NUMBER: SU-01-0001 (10-08-08) 1 WAIN FIM PORK TREIAIED. LI118ER (SEE N01E i11) PIER CAPPED 911 SOI14 OQIIan-- I = (NDL 4' iNCK) r X T X 1Ni CELLED MASONRY liiOtSfS� V01 OPEN GELS VOCAL SEE TABLE I FOR PLEB FOOTS SIZE AND SPACING SPMU110E (PAGE 11) (SEE SU-4A FOR 16 X 16 PRECIAST PIER PAD SPACING) SEE NOTE f4— IRFJM ALL WJNC MAMKt AND RACE PAD ON STABS SOIL, BELOW FRO LINE PER LOCAL CODE fflo 11BLiS IE DN STRAPS Amoo-\ TO R IOCE MAN CODIBNS ON E 01 SECTION 10 BE C@OffC1EO TO A DOIBE HEM ANC108 SEE NDIE MIZE iREADfD SEE NOTE 13 __1 - N07E 12-/ DETAIL - DETAILS "A" AND "B" e — SEE NOTE 02 DETAIL 'A' pow vmEs wm ILAX. &OVABE SDI. BEARING) PBR CAPPED MIDI SOLO COINCIEIE SIM WL 4' THICK Or X Ir X lir MO MASM ELOCILS um OPEN MIS VOCAL (SEE NO E h FOR MIX. FERR NEIGIEIS AND 1X:TPL ABOVE) TABLE FOR PER FWB S M AND SPACING SPECff1G11016 (PAGE 10) REMOVE ALL MGAIOC MATERIAL AND PIAPE PAD ON STABS SOIL BELLY FROSRllJE.PER I= LODE RFAUiREi®RF5 \MENN12 (DIffNSNON v ES wm MAX AU.OV ELE I B e i l^81�o9/w _ NOTES: 1. 36' MAX. SINGLE STACKED FOR HOLLOW BLOCKS AT I —BEAMS. 54' MAX. PIER BLOCK DRY STACKED AT PERIMETER do MATING UNE. (PIER SYSTEMS ANY TALLER MUST BE APPROVED BY A LICENSED ARCHITECT OR ENGINEER) 2. MAXIMUM PIER/PAD PROJECTION: SEE OTHER DETAILS 3. ALL PIERS MUST BE CENTERED ON FOOTERS MUST BE WITHIN 1/2' OF PLUMB PER 3285 STANDARDS. 4. MARRIAGE WALL OPENING PIERS TO BE WITHIN 6' OF OPENING .ON EITHER SIDE OF COLUMN. (WHEN REQUIRED FOOTER SIZE PREVENTS A SINGLE `STACKED PIER FROM MEETING THIS, USE A DOUBLE STACKED PIER. GOOD UP TO 28 X 28 FOOTER.) 5. MINIMUM PIER PAD THICKNESS: A. 4' MIN. FOR PRECAST UNITS UP TO16'X16' B. FOR CAST IN PLACE FOOTINGS ON 2000 PSF SOIL (MAX.) THE MIN. THICKNESS IS MAX. F0071NG DIMENSION DIVIDED BY 4.(BUT NOT LESS THAN 6') 6. ALL FOOTING CONCRETE TO HAVE COMPRESSIVE STRENGTH. (icl m 3000 PSI (MIN.) 7. PLACE 6 MIL POLY ON GROUND PRIOR TO POURING FOOTING CONCRETE. (ALL SEAMS TO OVERLAP 12' MIN.) 8 PIERS SUPPORTING THE 1—BEAMS TO BE WITHIN 24' OF BOTH ENDS AND NO MORE THAN 10' O.C. 9. PIERS MAY BE OFFSET UP TO 6' IN EITHER DIRECTION ALONG THE I —BEAMS TO ALLOW FOR PWMBING. ELECTRICAL, ETC. 10. FOOTING CONSTRUCTION MUST COMPLY WITH LOCAL BUILDING CODES. 11. WOOD SHIMS. WHEN REQUIRED ARE TO BE USED IN PAIRS INSTALLED IN OPPOSITE DIRECTIONS AND FITTED TIGHT BETWEEN THE 1—BEAM AND PiER CAP. SHIMS MUST BE MIN. 4' LONG BY 6' WIDE AND NO MORE THAN 1' IN THICKNESS. o� �' F •' ®� APPROVED BY m No 48 woo. Oft Revised Dec 17,2008 IPINC. . o TAT E OF FEDERAL MANUFACTURED HOME C O . i I ! CONSTRUCTION AND SAFETY STANDARDS . A .,: " •" WAIN Ft O.A. 09-07-93 MY. LEM JACOBSEN HOMES T - rA a W� A wOR ac Tu*DETAILS A & B P.O. Box US = sa+ wm�s AE ptol�rn �o ns smw mom FLw u► we rfaewr Re �c �s ao wk t LLRAms NLABFR PHONE (727) 726-1138 wrm�omN aoSM Dees SU-01=0001.1 ( 12-15-011 ) MOBILE HOME SET-UP NOTES: 1. JACKS TO BE RATED AT 5 TONS. 2. ALWAYS USE A SUPPORT UNDER JACKS. 3. FOLLOW BLOCKING INSTRUCTIONS. 4. FOR MULTIPLE WIDES SET HEAVY SECTION FIRST. BLOCKING SEQUENCE 1. LOCATE HOME ON SITE AND LEVEL AS CLOSE AS POSSIBLE USING HITCH JACK. 2. SET SUPPORTS (BLOCKS #1) UNDER BOTH I -BEAMS JUST FORWARD OF THE FRONT SPRING HANGERS. 3. SET SUPPORTS (BLOCKS #2) UNDER BOTH I -BEAMS JUST BEHIND THE REAR SPRING HANGERS. 4. LOCATE SUPPORTS (BLOCKS #3 MAXIMUM 24" BEHIND THE FRONT CROSSMEMBER. 5. LOCATE SUPPORTS (BLOCKS #4 MAXIMUM 24" FROM THE END OF THE HOME. 6. ADDITIONAL SUPPORTS (BLOCKS #5) MAY BE NECESSARY BETWEEN 1 & 3 AND 2 & 4, IF THEY ARE NEEDED THEY SHOULD BE SPACED EQUALLY, MAXIMUM SPACING 10'-0". 7. IF YOUR HOME HAS 4 AXLES ADD BLOCKING BETWEEN THE MIDDLE SET OF AXLES. 8. FOR SINGLE WIDES BLOCKING IS COMPLETE. 9. FOR MULTIPLE WIDES REMOVE ALL SHIPPING BATTENS AND VISQUEEN AND SET LIGHT SECTION(S) AS CLOSE AS POSSIBLE TO THE ALREADY SET HEAVY SECTION. 10. JACK THE LIGHT SECTION(S) TO THE HEAVY SECTION USING JACKS AND COME-ALONGS. 11. FOLLOW BLOCKING SEQUENCES 1 THRU 7. NOTES: 1. THESE FOUNDATION SPECIFICATIONS HAVE NOT BEEN DESIGNED FOR FLOOD -RESISTANT SPECIFICATIONS. 2. PERIODIC RELEVELING MAY BE NECESSARY BECAUSE OF THE WEIGHT OF THE HOME AND SETTLING THAT MAY OCCUR. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFlCATIONS AND DRABINGS ARE DRAWN BY: O.A. DATE 06-06-94 REV. LETTER: P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONRDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: MOBILE HOME SET-UP 2 HEILtIE10 INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HONER 727 726ID1138�95 RECIRENT FOR KEPT C NRDFNTIAL�AND FRROOM O HERS ST BE DRAWING NUMBER: SU-01-0002 (09-30-08 i1 mi SEE NOTE #77 SEE NOTE #6 4 2 1 5 5 3 f-SEE NOTE #2 NOTE #1 I \-NOTE #5 NOTEE 3 # TYPICAL SINGLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) SEE NOTE #7 SEE NOTE #6 le llw- tt� NOTE #3 TYPICAL DOUBLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAPANGS ARE S.A. 6-6-94 ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: DOUBLE WIDE BLOCKING ❑ P.O. BOX 368 MATERIALS OF MANUFACTURING „❑ INC. SUCH MATERIALS IALS ARE RE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM DTHERS. SU-Ol -0003 4 SEE NOTE #7 SEE NOTE #6 2 1 3 NOTE #3 4 2 1 NOTE TC#6 5 5 3 TYPICAL TRIPLE WIDE BLOCKING SEE NOTE #7 NOTES #1-MAIN FRAME I -BEAMS #2-LOCATE PIERS UNDER FRAME I -BEAMS #3-LOCATE PIERS UNDER CLOSEST FLOOR JOIST EACH SIDE OF OPENINGS 48" AND LARGER. (I.E.-RECESSED ENTRIES AND SL. GL. DRS.) SEE TABLE FOR PIER FOOTER SIZING PAGE 10. #4-LOCATE PIERS UNDER MARRIAGE WALL PERIMETER JOISTS WITHIN 6" OF EACH SIDE OF OPENINGS. 48" & LARGER AND RIDGE BEAM COLUMNS. SEE TABLE FOR PIER FOOTER SIZING SU-01-0030 AND SEE DETAIL 'B', SU-01-0010. #5-AXLE ASSEMBLY CENTER LINE #6-SEE TABLE I FOR PIER FOOTER SIZING AND PIER SPACING INFORMATION SU-01-0040, AND DETAIL 'A' SU-01-0010. #7 ')CKING SEQUENCE NUMBERS, SEE SU-01-0002 FOR PROPER BLOCKING PROCEDURES. ❑❑❑❑ ❑❑■❑ ❑„❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRANINCS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROMDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: - DRAWING TITLE: TRIPLE WIDE BLOCKING DRAWING NUMBER: SU-01 -0004 5 ADDITIONAL PERIMETER BLOCKING (THIS BLOCKING IS IN ADDITION TO BLOCKING REQUIRED IN THIS MANUAL) r M �I TYP. FIREPLACES ON SIDEWALL OR MARRIAGE WALL HOST BEAN NOT PERIMETER BLOCKING REQUIRED AT 48' O.C. MAX. 54' OR 60' TUB AT SIDEWALL OR MARRIAGE WALL UNDER EACH SIDE OF ALL EXTERIOR DOORS LOCATED ON SIDEWALLS 2 OR MORE 46 1/2' WINDOWS PIERS REQUIRED AT EACH END AND BETWEEN EACH OPENING RECESSED AREAS REQUIRE PIERS SPACED 647 O.C. MAX. (18' OR LESS IN DEPTH) EACH END OF RECESSED AREAS RECESSED AREAS W/SIDE BAY REQUIRE PIERS SPACED 64' O.C. MAX. THIS ALSO APPLIES TO ALL ENDWALL BAY WINDOWS UNLESS SUPPORTED BY A FRAME MEMBER GARDEN TUB AT SIDEWALL OR 64' O.C. MAX REFER CABINETS ALONG SIDEWALL OR MARRIAGE WALL (APPLES TO BATH CABINETS 80' OR GREATER IN LENGTH) (SAME BLOCKING MAY BE USED FOR MULTIPLE 46 1/2' WINDOWS) SPECIAL BLOCKING NOTE FOR 15"-4" (184"-) WILE FLUOR StCIIUNS PERIMETER BLOCKING IS REQUIRED (MARRIAGE AND SIDEWALLS) 64' ON CENTER MAX. SPACING NOTE: LEVEL FLOOR SYSTEM FIRST (SIDEWALL TO SIDEWALL OR MARRIAGE WALL) BEFORE INSTALLING PERIMETER BLOCKS NOTES 1. ADDITIONAL BLOCKING REQUIRED AS INDICATED ABOVE (USE 16' X 16' PIER PADS). 2 LOCATE BLOCKING UNDER PEPoMETER JOIST OR WITHIN 8' OF END OF 16' O.C. JOISTS. 3. COLUMN PIERS ARE IN ADDITION TO REQUIRED PIERS UNDER FULL -HEIGHT MATING WALLS 4. PERIMETER BLOCKING IS REQUIRED UNDER TILE FLOORS (MARRIAGE & SIDEWALLS) 64' O.C. MAX. 5. PIERS USED FOR PERIMETER SUPPORT MUST BE INSTALLED WITH THE LONG DIMENSION PARALLEL TO THE PERIMETER RAIL 6. WHEN PERIMETER BLOCKING IS REQUIRED ANY MATING LINE OPEN SPAN GREATER THAN 10', MUST HAVE INTERMEDIATE PIERS PLACED AT MAX 10' O.C. EXCEPT 154 WIDE, SEE SPECIAL NOTE ❑❑❑❑ ❑❑■❑ m JACOBSEN HOMES P.O. BOX 368 SAFEPHON(HARBOR,) 7261D1138�95 NOS MO SPECO1CAnONS AND CONRDE ARE ORIGOIAI, PROPRR:'URY, AND CONFlDFNna MATERIALS GF MOM MANUFAC71MIG INC. ENT FOR Y SPWIS ARE WiG AM MUST BE TO nff WT COIRDENTI AM SEW FROM OHM 8Y' O.A. 4-12-00 `�"' `E'�` (09-30-08 ) OKAYING TITLE . ADDITIONAL BLOCKING ORATING NUMBER: SU-01-0005 61 (APPLICABLE TO ALL IMPERIAL AND RI LORD COTTAGES OTH 184' FLOOR 00THS-SEE FL-01-0009.2) ON SITE PERIMETER 16 X 16 PIER PAD 17 X 25 PIER PAD MIN. BLOCKING O.C. SPACING 1000 PSF SOIL 1500 PSF SOIL 1000 PSF SOIL SIDEWALLS/MATELINE WALL 48"/24 64"/40" 64"/48" MAX LOAD INCLUDING PIER AND FOOTER 1778# 2667# 2950# E Al No 454(;F— SBA+ E OF °o ALL v�NDzoNES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. C-FL- 89.01 - 89.03 APPROVED BY May 07,2009 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOT1d4 KV. LETTER: JACOB6EN HOMW s��or�cAT s e�A ,� Ds �" �,T DATE, 03_02-09 �tLt.$ o T �DRA NC n7L6 a,o, eox afie s L! Witte u. m ADD. PER, BLOCKING REQUIREMENTS SAFETY HARBOR. (�7) FLORIDA26� 95 RtcA[ ► Tat s�a",IPt �T 'n�jl o�'� Da G U R7 SU- 01-0005.1 BLOCKING (PIER) LABELS LOCATE THESE LABELS AND CHECK THE APPROPRIATE MANUAL FOR PROPER INSTALLATION OF BLOCKING AND PIERS.. SHEARWALL PIER LOCATIONS SEE SET—UP ADDENDUM FOR SPECIFICS BOTTOM OF EXTERIOR SIDING AT SIDEWALL SPECIFIC PERIMETER PIER LOCATION SEE SET—UP MANUAL FOR SPECIFICS BOTTOM OF EXTERIOR SIDING AT SIDEWALL NOTES 1. THIS IS INCLUDED IN THE HOME OWNERS PACKAGE. COLUMN PIER LOCATION SEE SET—UP MANUAL FOR. SPECIFICS (LOCATE THESE PIERS AT ji, THE MARRIAGE LINE) A JACOBSEN HOMES NMAalA „� sP�cAnaa ro wRcs ARE MA�o I M.T. "' 05-20-06 P.O. BOX 388 ORWIAL PROPWMY. AND CORFVO ML "A11MI&S OF •fig" MAMAAC1UI M DRAIMNG MM- BLOCKING (PIER) LABELS „ SAFETYHONER(OR.) FLORIDA Ir. SM YATEMS ARC PROWED 70 71E � SPE�r AND SWU RM ORK DRAIMNG M11�ER SU-01-0006 f ADDITIONAL RECESSED PORCH BLOCKING (THIS BLOCIM IS IN ADDITIM fi BLOCIM REOIIIRED N THIS MANUAL) _ . 61' VAX 61' WAX USE DETAL v ONCY *0 OUTRIGGER IS ON FLOOR JET SE OETAL 'A' SEE DETAL g DIRECTLY UNDER PORCH POST ------- ------ •—— —B�------- —-- m W. RECESSED PORCH a tx>ER>oR T EXTm ruuL - ADDED I-ffm um EXTERIOR M'AI.L _ PER UNDER ADDED I -BEAM RECESSED PORCH REOIAtE PENS SPACED 64' O.C.'WAX PER UNDER ADDED I-lxAY (AND PIERS AT PORCH POSTS) AS SHOWN 64" O.C. MAX _ r PIER SPACING AT MMUAGEWALI. NOTE: DISTANCE BET#M EDGE OF PIER AND EDGE OF PORCH POST TIP. PORCH POST MAY NOI EXCEED DEPTH OF TV. KM POST FLOOR JOIST (51M 4/5 112, Ma TYP PORCH F x'" TV. PORCH FLOORHG �� PORCH FLOOR JOIST DOABLE PORCH PERDEIER —_ �� (2) 2 X 6 PT X 111' IK no Mum 2 pp. TE-001EIN STRAP (SEE Onb DETAkS) PORCH FLOOR Jasrs UP.PER(6'X6'X16') 16' X IV WH. PER PAD BOSS SECTION VIEW At • TYP. PORCH POST T1fP. PORCH FLOORING PORCH FLOOR JOIST (2)2X6PTx1a-UK EMT1m IIETTIEEN 2 PORCH FLOOR. JOISTS LONGTTUDWAL VIEW A2 DETAIL ' A' PORCH FLOOR JOIST DOUBLE PORCH PEROM RALr 2 X 6 PT X 18' YTL OCED BETWEEN 2. TIP. RE-DOVIN STRAPRCH FLOOR JOISTS (SEE 01HER DETALS) (11' X 6' X 161 16' X 16' UK PIER PAD CROSS SECTION VIEW BI TV. PORCH POST NOTE: DISIANCE BEPRID EDGE OF TIP. PORCH FLOORPIG ��l%2' PIER AND EDGE OF PO 1 POST PORCH RDOR %Ml WAY NOT ET® 5 1/2' (28)6 PT X 18i11DL� TIP. 11E-M SW (SEE Ol[iER DE7A1S) PORCH FLOOR JOISTS WNGI1tUDINAL. VIEW B2 se,E„81'rDETAIL 'B' NOTE0 . �4F1Cti}�•�'y NOTE& + d+O L A001TNINAL BL0C0Ic RE*m AS MI 01ED ABOVE (USE 16' X IC PER � � O, d 4a 3 �{ • PAOS 04 1000 PSF SOL CAPACITY) . 2. LOCATE BIDOON UNDER PENMW JOIST OR IN01N S t/i Cf END Of 16' Qc f 1 PFR41m BLOC3w 15 REQ!lRED UNM PM AT EACH P05T (61' O.C. UAX) • 4. AD0nmx BLocrA REG1>1ttD AS INDN;ATED AM UmmR CENTER OF ADDED I-va v t ' (64 Q 1 MAX) • �Ec+ ' �`r P � S SEE GM DETAIS Fd10DE11 REGUIRED BLOOM LOCAlm f �� � O F'. ,•' ��q,'1' 6 ADDED F-BEAY AT PGRGB/TXIERIOB WILL MAY MTER 01 91 FROM MAIN HOUSE 1-BEAw ��, sTFr`. xonc� s= m._ 1: F JACOBSEN HOMES » wcw=,w Aw WAWM AM CNCWA. ApOMKTm% ATO ooNT10 I& DRAWN RILL MAE> M OF dACOM MU WACRMW P.G. BOX 368 W. am MA1GTu s ME Mw= To U SAFETY HARBOR. FLORIDA W95 Kmw FOR SPOtrl1C FVrgSF9 NO 90 IE DRAWING NUMBER: PHONE (813) 726-1138 I= CrAm 9 APPROVED BY e Dec 13,2006 a INC. s FEDERAL MANUFACTURED MOPE i CONSMUCUON AND SAFETY STANDARDS 1 SL1-01-0007 ATTACHMENT TO HOST BEAM ATTACHMEI4T MAY BE FLUSH WITH HOUSE -� - HOST BEAM STRUCTURE ATTACHMENT SECURED DIRECTLY TO FACTORY INSTALLED HOST BEAM (THIS IS IN LIEU OF 'FOURTH WALL CONSTRUCTION") STRUCTURE ATTACHMENT INSTALLED ON -SITE BY OTHERS -AND MUST MEET LOCAL CODES PERIMETER BLOCKING ON -SITE 48' O.C. MAX. DESIGN MEETS FBC AND A.SCE FOR 140MPH (3 SEC. GUSTS) EXP. B LOADING FOR PARTIALLY ENCLOSED STRUCTURES- REF. PG. 07-0050, 07-0051 NDS01 �`� NOTES: 1. HOST BEAN RISTALLATION IS FOR ON -SITE STRUCTURE ATTACHMENT: 4,�i f-��11 F; : T 20' WIDE MAX WIND ZONE 2 OR 1211PH EXP. B SITES. 16' WADE MAX (WIND ZONE 3 OR 140MPH EXP. B SITES '�^ `; 2. MIN. BRACKET LOAD CAPAaTY FOR VERTICAL BE -DOWNS IS 24501 WIND ZONE Z 29601 WAND ZONE 3 3. WALL FRAMING IS 2 X 6 SPF /J IC O.C. d. �`' 9 ••.,_ Gaff r F �4 4. 48'. O.C. PERIMETER BLOCKING REOLIRED ON HOST BEAM SIDE OF HDUSE , :' :.OR1a•' JACOBSEN HOMES >� ►wa An DR `ttWwI ' CROML PROPRIETARY, AND CUMIX DRI t" P.a Sox s6a wIMUIS OrJA�H �A*ACROM INC 9JW MA70MS ARE FROv1OEW W THE SAFETY HARBOR, FLORIDA 34695 R cmv Rut 9'ECFIC Ftff S AO um K W, PHONE (727) 726-I I U APT COnOM&L AND SEatEr FROM °WZM 10 i®I ALSO MEETS WINDZONE. III E>POSURE C 20 PSF ROOF 10 PSF D.L. APPROVED BY dp Jan 20,200 INC.1; 1 FEDERAL UANUFACIURED NONE CONSTRUCTION AND SAFETY STANDARDS D.M.T. DATE 01-10-07 NEW.1EM ATT. TO HOST BEAM am SU-01-0008 tAlt� BLOCKING FOR TEMPORARY SET FLOOR SYSTEM MUST BE LEVEL SINGLE WIDE UNIT BLOCKING PIER MAIN I -BEAM HEADER BLOCKING PIER MAIN I -BEAM _ HITCH TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN I -BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. MULTI -WIDE UNITS BLOCK EACH UNIT OF MULTI -WIDE HOME IN SAME MANNER MAIN I -BEAM HEADER AXLE 11 MAIN I -BEAM BLOCKING PIER BLOCKING PIER MAIN I -BEAM MATE LINE - - - AXLE MAIN I -BEAM BLOCKING PIER BLOCKING PIER MAIN I -BEAM 7 ii I! I! FLOOR SYSTEM MUST BE LEVEL MAIN I -BEAM HEADER TEMPORARY BLOCKING IS REQUIRED ON HOMES LOCATED AT THE DEALERS LOT OR PARKED AT HOME SITE FOR ANY PERIOD OF TIME. BLOCKING PIERS ARE TO BE LOCATED UNDER MAIN I -BEAM AT THE REAR, AT THE HITCH, IN BACK OF AND IN THE FRONT OF AXLE AREA. 15'-4" (184°) WIDTH UNIT REQUIRES PERIMETER BLOCKING 96" O.0 AT SIDEWALL AND MARRIAGE WALL. ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 ❑❑❑❑ SAFETY ASPHONER(727) 726FLORIDA 3 4695 NOTICE: THESE SPECIFICATIONS AND DRAMINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECPENT FOR SPECIFIC P WOKS AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS 11 HITCH DRAWN BY: DATE REV. LETTER: D.M.T. 10-10-08 DRAWING TITLE: TEMP. BLOCKING DRAWING NUMBER: SU-01-0009 BLOCKING NOTE HORIZONTAL OFFSETS FROM THE TOP TO THE BOTTOM OF THE PIER MUST NOT EXCEED 1/2". (THIS APPLIES TO ALL BLOCKING.) w JAC 0 B S E N HOMES NOTICE: DRAWN BY: DAIS REV. LE17ER: nIESE sPE�tcAna+s AND DRAIMNGS ARE O.A. 10-17-08 ORIGINAL PROPRIETARY, AND CONRUENIIAL DRAWING TITLE: YATEFDALs Of JACOBSEN MANUFACTMNcBLOCKING NOlE P.O. BOX 368 INC. SUCH YATFRIµ,g ARE PROVIDED M DIE SAFETYPHONE HO ER(07) 7261DA34695 nK n�FCWM I11FOR �A MD FRROOY 1�FERS� DRAWING NUMBER $U_01-0010 12 16" X 16" PIER FOOTER SPACINGS* MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR 39" 62" 86" 110" 134" 157" 144' WIDE FLOOR 33" 53' 73" 93" 113" 133" 160" WIDE FLOOR 30" 48" 66" 85" 103" 121" 184" WOE FLOOR 26" 42" 58" 74" 90" 107" MIN. PIER CAPACITY 1778 LBS. 2667 LBS. 3556 LBS. 4444 LBS. 5333 LBS. 6222 LBS. NOTE: ALL UNIT WIDTHS INCLUDES A 6' OVERHANG ON BOTH SIDES MAXIMUM. 4" MINIMUM, AND/OR PER LOCAL CODE REQUIREMENTS 4,.TYP 7" OR 8" .. T TYP 3MAX T " x TYp) Q Q NOMINAL 16" X 16" SQUARE PRECAST 00 00 T CONCRETE FOOTING �I 16" MIN. EACH SIDE 4 X 8 X 8 SOLID 6 X 7 X 8 SOLID FOOTING CONC. BLOCKS CONC. BLOCKS TYPICAL PIER FOOTER TYPICAL PIER CONFIGURATIONS (THE CAPACITY OF THESE PIERS EXCEEDS MIN. REQUIRED) CONCRETE - NOTES WINDZONE III 1. ALL FOOTINGS CONCRETE TO HAVE fc' = 3000 PSI MIN AT 28 DAYS; (110 MPH) ALL EXPOSURES 2. ALL SOLID CONCRETE BLOCKS TO HAVE fm' = 1500 PSI MIN; 20 PSF ROOF 3. CENTER ALL PIERS ON FOOTINGS 10 PSF D.L. REF. CALLS. e (, (/ A-_ � NOTES: EN V •• . F`��i� i ``,�'�STERFp' DAPIA APPROVAL I. REFER TO OTHER DETAILS FOR ADDITIONAL PIER FOOTER SIZES AND N0. y APPROVED EY SPACINGS. 910334 •' 2. START I -BEAM PIER SPACING 112 THE ALLOWABLE SPACING FROM EACH END cos OF THE HOME AT EACH I -BEAM, AND MAXIMUM SPACING SHOWN IN THE CHART ABOVE FOR FULL LENGTH OF HOME. A �. STATEIN [IINC. 3. SEE OTHER DETAILS FOR PIER REQUIREMENTS AND MAXIMUM OPENINGS % Q'•./ P.• '. , /`/ P► \ �� '�� FEDERAL MANUFACTURED HOME AT MATING LINE OF MULTIPLE WOE HOMES. ,. �' / tSs . •.•Mn� CONSTRUCTI E �QAROS 4. SEE OTHER DETAILS FOR TIE -DOWN, REQUIREMENTS. " """' JACOBSEN HOMES Noffic4l THESE SPECIFTCAna+S Mli DRAVOINJ ARE ORKDNAL PROPRIETARY. AND 00141FmENT1AL AWN BY: M.T. DATE 2-8-99 REV. LETTER 8 DRAWING TITLE: MATERIALS OF JACOBSEN MANUFACTURING 16" x 16" PIER SPACING P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 DN:. SUCH MATERIALS ARE PROMDED TO THE REcp[DIT FAT SPEcM PIAROSES AND WMT BE Wl CONSDEMUL AND SECRET FROM OTHERS• DRAWING NUMBER. - SU-01-0020 13 ALTERNATE M IN BEANS PIDR� r (�xa�a*nTAR1 �Ut{11GY USID FQt a~, a `, a �� t It 6r x le HOLLC* C*CRETE HLOG( S S , HE • a i 4(SiE � r6) mm � tt FAL O MIS,4Rd� K TOP 10 TK 400 BOital OF Aff PER µ1ST IjOT EEO1�! MATED LUDo VR (SEE ®o �,v000e.,F s ® �i • ® ®X !r x 16' tEUID TTLOOcS 0000 `�oc E Al S;�4F��®®I�TMN �s SI GLE STACK BL�K PIER (PElFEl4� lRo ro Ai( j No 45484 � $OOO LBS I�rUUt�� CAPAOTY-SEE lE 0 o m 0 T g x g x 16" Hilo CI*CRETE BLOCKS ABE SH* IOECAY AE •T 1A1,1 Alpo° ®aBeBa�Kao®e40°o T tREA >H�c * In TOP TO THE 4X Six (SEE B0 Hol 1HE PffA I�U9Pt40T Ex® 1%t. RER CAPPED t1H Copra Tt r THICK& � I If x If x 16* 1ETLED *i y BLOM OTH OPEC( CTTLS "WA DOUBLE STACK BLOCK PIER 140 In CAPAM (SEE 401E 0 A 12) FLOOR "DTH MAX. MAXIMUM I -BEAM PIER SPACING (CONTROLLED BY PIER LOAD CAPAORES) 48" O.C. 72" O.C. 96" O.C. 120" O.C. 144" *DE FLOOR 242E LBS 3488 LBS 4548 LBS 5608 LBS 160" *BE FLOOR 2661 L I 38M LBS 5014 LBS, 6191 LOS. Me *DE FLOOR 2961 LBS 4288 LBS 5615 LEM 6941 LBS. PIER LOADS INCLUDE (;HT OF PIER UP TO 2500 - ADD DIFFERL14M WNEt4 PIER Wiwi S GREATER. 407Et UNIT *oTHS INCLUDES A 6' OVERHANG ON BOTH' SIDES VAx" REs_ Chm (CHECK PIER PAD LOAD CAPACMES BASED ON SOIL BEARING PSF) �0 1-om FOR PAR SPACd4G *0 U", 16' x le PO PADS, IS40 le x le p PADS OT C01 XTE Ky µSt BE US1ED Atp CER TO EXCEED OR BE EQUAL 4 CAPACITY $ MIEN UAG PIER PADS THEY VUST BE LISTED & CERWID TO EXCEED OR EQUAL 04 M CAPAM A START OXG N THE CHART A FROV * FOR FULL of .TEACH 1-BEAM A!p �IAY�I 4. Ay PQR QM Aeo►iE 5? 0,sr BE DES►Op BY A P.E. OR AROnTEC1, & COSSWST BE SASE LE40TH AtO #DTH AS THE PIERS ON #M THEY REST, A�j 6. BE USED TO PLATESANY =1T TtCAL�GAPR 2 OR 4 *P NO�d4Ai SW COI MTE MM VAY 11 20 PSF ROOF 10 PSF ML. APPROVED BY ONReviaed Oct 17,2008 O rpNC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS p[SE s�anuNandc: DRAFT( Br. 0 A pA1Q �-8-99 eey, �ene0c JACOBSEN HOMES n.18 B. pe�ETA LIE-10" Plo, 1G nnF, ACT. VAIN BEAD PIERS D SAFETY HARBOR, FLU A 34M MsT DR G Wom— PHONE (727) 726-1138 mR YpscO T oao� SU-01-00IA 110-0870 14 MINIMUM HOME SET HEIGHT FINISH GRADE NOTES: WHERE THE GRADE IS SLOPED, 25% OF THE LOWEST MEMBER OF THE MAIN FRAME MAY BE SET BELOW 18"; HOWEVER, UNDER NO CIRCUMSTANCES MAY THE BOTTOM OF THE I -BEAM BE SET BELOW 12" FROM THE FINISHED GRADE. ❑❑❑❑ [:][:IMF] JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING MATERIALS DRAWN BY: B.E.M. DATE: 2-11-99 REV. LETTER: DRAWING TITLE: MIN. HOME SET HEIGHT ❑,.❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-01 -0022 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 15 16" X 16" PIER FOOTER SPACINGS* ( MIN. 256 SQ. IN). MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR-- 39" 62 1/2" 86 1/2" 110" SEE NOTE b4 SEE NOTE #4 144" WIDE FLOOR-- 33" 53" 73 1/2" 93 1/2" 113 1/2" SEE NOTE #4 160" WIDE FLOOR. 30" 48 1/2" 66 1/2" .85" 103" SEE NOTE #4 184" WIDE FLOOR- 26 1/2" 42 1/2" 58 1/2" 74 1/2" 90 1/2" 107" MIN. PIER CAPACITY 1778 LEIS 2667 LEIS 3556 LEIS 4444 LBS 5333 LBS 6222 LBS 18 1/2" X 18 1/2" PIER FOOTER SPACINGS* (MIN. 342 1 4 SQ.IN) MAXIMUM I 'BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR-- 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR- 46" 73" 100" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR.. 42" 66 1/2" 90 1/2 115" SEE NOTE #4 SEE NOTE a4 184" WIDE FLOOR•v 37" 58 1/2" 79.1/2" 101" SEE NOTE #4 SEE NOTE p4 MIN. PIER CAPACITY 2377 LBS. 3565 LBS. 4753 LBS. 5942 LBS. 7130 LBS. 8319 LBS. NOTE: UNIT WIDTHS WITH to INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 �0 -3 / NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE ENGINEER APPROVAL: •• DAPIA /APPROVAL: G� �'�� '!�.. C y FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. c; 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE `�n' - APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN STATEtom .r. ' �' i �� ' _ OCT 1 Y - rNT14 HOMES INSTALLATION INSTRUCTIONS.':';(r '. '�'+�'•`.' r INC. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH IO" OR e•.';" 12' I -BEAMS (24' MAX. FROM ENDS). FEDERAL MANUFACTURED HOME TI NANDSAFETYSTANDARUS ❑❑ JACOBSEN HOMES NOTICE: THESE SPECIi1CAnoNS AND DRAWINGS ARE DRAWN BY: D.M.T. DATE: 09-22-01 REV. LETTER: P.O. BOX 368 ORIGINAL, PROPRIETARY, AND L'V#IDENTIAL SENARE ROOD D TO ING INC. SUCH NAIERIA�S ARE PROtAOED i0 THE NC. SUCH OF JACOMATERIALS THE DRAWING TITLE: PRE-FAB. 16" & 18 1 2" PIER PAD SPACING / ❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIRENT FOR SPECIFIC PURPOSES AND MUST BE NEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: SU-01-0023 16 18" X 22" PIER FOOTER SPACINGS* (MIN'. 396 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR+• 63 1/2" 100 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 54" 85" 116 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR-- 49" 77 1/2" 105 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR•* 43" 68" 93" 117 1/2" SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 2747 LBS 4121 LBS 5495 LBS 6868 LBS 8242 LBS 9616 LBS 20" X 20" PIER FOOTER SPACINGS* ( MIN. 400 SQ. IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 64 1/2" 101 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR** 49 1/2" 78 1/2" 107" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR** 43 1/2" 69" 94" 119" SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 2778 LBS. 4167 LBS. 5556 LBS. 6944 LBS. 8333 LBS. 9722 LBS. NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES: ENCq APPR'�l �'ryA, .� DAPIA APPROVAL: THESJACOBSENMAY BE UHOMESSED SO THE CONCRETE SET --UP MANUALAN ALTERNATE T �� Q. 4,� _ r CC1 FOOTINGSRSPECFIEDEN PER THE 'Y�10 APPROVED BY 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED 910334 MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM c SHOWN ABOVE. •eft PIER CAPACITIES 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN X �" S ATf- a HOMES INSTALLATION INSTRUCTIONS. �O'..� + INC. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' 1-BEAMS / 10' FOR UNITS WITH 10' OR yy� .�a' 12' I -BEAMS (24" MAX. FROM ENDS). EOERALMANUFACTUREDHOhiE c •+in rDATE: r JACOBSEN HOMES NOTICE: ! USN THESE SPECIFICATIONS AND DRAWINGS ARE 41BY: D.M.T. 09-22-01 REV. LETTER: DRAWING TITLE: PRE-FAB. 18' X 22" $ 20" PIER PAD SPACING ORIGINAL. PROPRIETARY, AND CONFIDENTIAL MATERIALS OF KCOBSEN MANUFACTURING P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PROVIDED TO THE REp1ENTFOR NTECD� PURPOSESAND MUST BE OTHERS. DRAWING NUMBER: SU-OI-OOZ4 PHONE (813) 726-1138 17 1 17 3Z16" X 25 3/16" PIER FOOTER SPACINGS* (MIN. '432 7/8 SCIAN) MAXIMUM I —BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 70 1/2' 110 1/2' SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR 59 1/2" 93 1/2" SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 SEE NOTE y4 160" WIDE FLOOR. 54" 85" 116" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR- 47 1/2" 7.5 102" SEE NOTE y4 SEE NOTE y4 SEE NOTE y4 MIN. PIER CAPACITY 3004 LBS. 4507 LBS. 6009 LBS. 7511 LBS. 9013 LBS. 10,516 LBS. 24" X 24" PIER FOOTER SPACINGS* (MIN. 576 SQ.IN) MAXIMUM I —BEAM . PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR.. 95 1/2" SEE NOTE #4 SEE NOTE N4 SEE NOTE #4 SEE NOTE.N4 SEE NOTE #4 144" WIDE FLOOR-- 81' SEE NOTE y4 SEE NOTE p4 SEE NOTE y4 SEE NOTE y4 SEE NOTE #4 160" WIDE FLOOR** 74" 115" SEE NOTE y4 SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 184" WIDE FLOORS 65" 101" SEE NOTE y4 SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 MIN. PIER CAPACITY 4000 LBS 6000 LBS 8000 LBS. 10.000 LBS. 12.000 LBS. 14,000 LBS. NOTE: UNIT WIDTHS WITH .• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE 'SU-01-0021 NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE EN P OV �`i '! p `C�� C�4: ' G�s T y� ��% •¢ No. {� DAPIA APPROVAL: S CkL�s �rY FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. ; � — 14, 03 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE 910334 Gzz APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM �.•� PIER CAPACITIES SHOWN ABOVE. nr- =JTIHT�KEOERALNIA OCT 1 1 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN �Q•'•, HOMES INSTALLATION INSTRUCTIONS. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH 10' OR ��I'•'•\a ; '�� •' F• '' �� •'INC. ts' 12' I -BEAMS (24" MAX. FROM ENDS). D HOME � hi Amn gag TV qI O�DO J AC O B S E N HOMES NOTICE: THESE SPEGFlCAiIONs AND DRAWINGS ARE DRAWN BY: D.M.T. DATE: 09-22-01 REV. SETTER: DRAWING TITLE: pRE—FIB. 17 X 25 do 24' PIER PAD SPACING KP9 P.O. Box 368 SAFETY HARBOR, FLORIDA 34695 ORICINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND N1SE BE _ NUMBER: PHONE (813) 726-1138 KEPT CONRDENTIAL AND SECRET FROM OTHERS DRAWING SU-01-0025 18 26" X 26" PIER FOOTER SPACINGS* (MIN. 676 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR. 113 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR.. 96 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR-- 87 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 SEE NOTE y4 SEE NOTE y4 184" WIDE FLOOR** 77" 119 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 SEE NOTE #4 MIN. PIER CAPACITY 4694 LBS. 7042 LBS. 9389 LBS. 11,736 LBS. 14,083 LBS. 16,431 NOTE: UNIT WIDTHS MATH •r INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES: TO THE E; A OV ��� Q',.•'•\STEM' Fir r' OAPA APPROVAL' S�Le �f�L 1. PRE —FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE CONCRETE FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET—UP MANUAL. 2. THE PRE —FABRICATED PIER PADS ARE TO BE INSTALLED PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM 910334 = APPROVED BY PIER CAPACITIES SHOWN ABOVE. REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN � �T S Ar 3. ALL OTHER ref i• '•,' : •3 ' •Lux. Ill OCT I 1 HOMES INSTALLATION INSTRUCTIONS. , 4. MAX. PIER SPACING 8' FOR UNITS WITH 8" I —BEAMS / 10' FOR UNITS WITH 10' OR U`a �C HINC. 12" I —BEAMS (24' MAX. FROM ENDS). FFIF ! + I IIfA� IP�FI f:'c JACOBSEN HOMES NOTTC : THESE SPECIFICATIONS AND ORABINGS ARE RAWN BY: D.M.T. DkZSTRUC110NAND SAFE 09-22-01 Y ypE�1 Ng P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING TITLE: PRE-FAB. 26" PIER PAD SPACING SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIPIENT FOR SPEOFIC PURPOSES AND MUST BE KCPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-01 —0026 19 17" X 22" PIER FOOTER SPACINGS* (MIN. 374 SQ.IN) MAXIMUM I —BEAM PIER SPACING NOTE: MAX. PIER SPACING WITH k** SEE NOTE #4 FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR•. 580 89" 120'tia 120'*** 120"*** 120'*** 144° WIDE FLOOR** 50' 76' 103'*** 120"*** 12U"a* 120'*** 160" WIDE FLOOR** 45" 69 1/2' 94" 11g'*** 120'*** 120"*** 184" WIDE FLOOR** 40' 1 61" 83" 104'*** 120'*** 120"*** MIN. PIER CAPACITY 2597 LBS. 3896 LBS. 5794 LB& 6493 LBS. 7792 LBS. 9090 LBS, NOTE: UNIT WIDTHS WITH ** INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 PIER PAD (CORNERS MAY BE ROW) TYPICAL PH FRAME 1-BEAM A. ORIENTATION OF BLOCK PLACED SYMETRICALLY ON PIER PAD ®ed�gg60®®OBg®p9S0 REF. CALL. PG. NOTES, DAPIA APPROVAL' 1. PRE -FABRICATED PIERS MAY BE USED AS AN ALTERNATE TO THE CONCRE ° SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL APPROVED BY 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE ® Ski: (': j; m INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM BQ e Dec 04�2009 MANUFACTURER'S ^ „•� a� PIER CAPACITIES SHOWII ABOVE. 1p °°• � �_ .. ® INC. 3, ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN eo S • • • OO INSIRUC110NS 6 is b FEDERAL fIAlWFACHRIED HCHI E CONSTRUCTION MD SAFETY STANDARDS HOMES INSTALLATION AL ®�®®/�� 4. MAX. PIER SPACING Ir FOR UNITS PATH 8' I- -BEAMS / 10' FOR UNITS VOTH 10' OR ®®099®00�1 12" I -BEAMS (24' MAX FROM ENDS -USE 1/2 THE MAX. PIER SPACING IF THE PIER SPACING IS LESS THAN 48' O.C. JACOBSEN HOMES )[OTlC1% THm uws w mwm DUN BY. M.T. DATE: 11-23-as REY LITTER: DRA�NG n ° 17 X 22' PIER SPACING ORMOL JR790 S JACFIRMOOM — P.O. BOX 368 m_ SAFETY HARBOR, FLORIDA 34695 01G 6VOI INTER" ARE•PROWOED TO THE RDTPBR FOR 9�1FC RIP O ARD Must 8E DRAVANG NUMBER; SU-01-0027 PHONE (813) 726-1138 WrOCRmmu.wse ummon= 10 PIER FOOTER SIZING CHART FOR MARRIAGE WALL OPENINGS (FOR SIDEWALL OPENINGS SEE NOTE Q) LOAD SPANS SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' w Q 1000 390 sq. in. 494 sq. in. 597 sq. in. 701 sq. in. 805 sq. in. 908 sq. in. 1500 260 sq. in. 329 sq. in. 398 sq. in. 467 sq. in. 536 sq. in. 606 sq. in. -� 2000 195 sq. in. 247 sq. in. 299 sq. in. 351 sq. in. 402 sq. in. 454 sq. in. C\l 2500 156 sq. in. 197 sq. in. 239 sq. in. 280 sq. in. 322 sq. in. 363 sq. in. MIN. PIER CAP. -9708lbs. 3428IDS. 4148lbs. 4868lbs. 5588lbs. 6308lbs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' A 1000 409 sq. in. 519 sq. in. 628 sq. in. 737 sq. in. 847 sq. in. 956 sq. in. 1500 273 sq. in. 346 sq. in. 419 sq. in. 492 sq. in. 565 sq. in. 638 sq. in. `r 2000 205 sq. in. 259 sq. in. 314 sq. in. 369 sq. in. 423 sq. in. 478 sq. in 2500 164 sq. in. 207 sq. in. 251 sq. in. 295 sq. in. 339 sq. in. 383 sq. in ifs MIN. PIER CAP. 2841 lbs. 3601 IDS. 4361 lbs. 5121 lbs. 5881 lbs. 6641 lbs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 428 sq. in. 544 sq. in. 659 sq. in. 774 sq. in. 889 sq. in. 1004 sq. in. 1500 286 sq. in. 362 sq. in 439 sq. in. 516 sq. in. 593 sq. in. 670 sq. in. 00 2000 214 sq. in. 272 sq. in. 329 sq. in. 387 sq. in. 445 sq. in. 502 sq. in. CO 2500 171 sq. in. 217 sq. in. 264 sq. in. 310 sq. in. 356 sq. in. 402 sq. in. MIN. PIER CAP. 2975 lbs 3775 lbs 4575 lbs 5375 lbs 6175 lbs 6975 lbs LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' A 1000 486 sq. in. 618 sq. in. 751 sq. in. 883 sq. in. 1016 sq. in. 1148 sq. in. 1500 324 sq. in. 412 sq. in. 501 sq. in. 589 sq. in. 677 sq. in. 766 sq. in. CD 2000 243 sq. in. 309 sq. in. 375 sq. in. 442 sq. in. 508 sq. in. 574 sq. in. 0 2500 194 sq. in. 247 sq. in. 300 sq. in. 353 sq. in. 406 sq. in. 459 sq. in. MIN. PIER CAP. 3375lbs 4295lbs 52151bs 6135lbs 7055lbs 79751bs NOTES: (D SEE DETAIL '8'. PAGE SU-01-ODOI FOR BLOCKING AND ANCHORING OF MARRIAGE WALL OPENINGS WADER THAN 49 INCHES. Q2 SEE NOTES; (1), Q3 , AND (D UNDER TABLE I, PACE SU-01-0040. Q3 FOR ALL UNIT WIDTHS. USE 177 sq/in PIER FOOTER UNDER SIDEWALL OPENINGS THAT ARE 49 INCHES TO 96 INCHES WIDE. FOR OPENINGS THAT ARE 96 INCHES TO 144 INCHES, USE 242 sq/'n PIER FOOTER UNDER SIDEWALL OPENINGS. (MIN. 1000 PSF SOIL BEARING REO'D) (D FOR PROPER LOAD SPINS, SEE SU-03-0001. ('LOAD SPANS' ARE CLEARSPANS; PIER SPECIFICATIONS ABOVE ASSUME CLEARSPAN OCCURS ON ONE SIDE OF PIER ONLY -. IF CLEARSPAN OCCURS ON 807H SIDES, ADD VALUES LISTED ABOVE FOR EACH CLEARSPAN) t�5 CHECK WITH LOCAL JURISDIC11ON TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 4GIN`li(iQA pkpvx8T11 ., c!e 'G\STEgF Q No. o' 910334 TATE ,V ; 4 ��'PO�, WINDZONE III (110 MPH) ALL EXPOSUR 20 PSF ROOF 10 PSF D.L. APPROVED EY IN INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS MAR 0 1 1999 NOTICE: - '� pFlAK91'8T DATE: B.E.M. 2-6-99 REV. LETTER: THESE SPECIFICATIONS AND pTAwrlGs ORIGINAL. PROPRIETARY, AND CONFIDENTIAL DRAWING 11TLE. PIER FOOTER SIZING CHART n MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE FOR MARR. WALL OPENINGS /� REOFIENT FOR SaM PURPOSES AND MIST BE DRAWING NUMBER: KEPT OONRUNTIAL AND SECRET FROM OTHERS SU-01-0030 21 TABLE I PIER FOOTER SIZING AND PIER SPACING CHART (SEE NOTES BELOW) 10—WTTIF. WTTITT4 MAXIMUM n n PIER SPACING SGCIAPACI BEARING PSF REQUIRED SQIE N FOOTER (D 3'-0" MAXIMUM FROM EACH END 1000 655 437 AND 8'-0" ON CENTER MAXIMUM 1500 327 (MINIMUM PIER CAPACITY 4548#) 2000 2500 262 4'-0" MAXIMUM FROM EACH END 1000 808 538 AND 10'-O" ON CENTER MAXIMUM 1500 404 (MINIMUM PIER CAPACITY 5608#) 2000 323 2500 13'-4"-WIDE WIDTH MAXIMUM Q Q PIER SPACING 3'-0" MAXIMUM FROM EACH END AND 8'-0" ON CENTER MAXIMUM (MINIMUM PIER CAPACITY 5014#) 4'-0" MAXIMUM FROM EACH END AND 10'-0- ON CENTER MAXIMUM (MINIMUM PIER CAPACITY 6191#) SOIL F RE IEA D AI ©F CAPACITY ®TER AREA, SQ. IN. 1000 716 1500 478 2000 358 2500 287 1000 884 1500 590 2000 442 2500 354 15'-4"-WIDE WIDTH MAXIMUM Q5 S REQUIREDPIER FOOTER IN. ® PIER SPACING CAPACITY ITYI Q2 ©F SQ. 3'-0" MAXIMUM FROM EACH END 1000 807 539 AND 8'-0* ON CENTER MAXIMUM 1500 404 (MINIMUM PIER CAPACITY 5615$) 2000 323 2500 4'-0" MAXIMUM FROM EACH END 1000 1.000 666 AND 10'-0" ON CENTER MAXIMUM 1500 500 (MINIMUM PIER CAPACITY 6941$) 2000 _ 400 2500 NOTES: ( ON MULTIPLE SECTION HOUSES. CHECK EACH SECTION INDIVIDUALLY. O2 UNDISTURBED SOIL OR 90% COMPACTION FOR FILL. 03 ALL FOOTERS TO BE BELOW FROST LINE. ® MORE THAN ONE PIER MAY BE USED TO ACHIEVE THE MINIMUM SQUARE INCHES REQUIRED. QS ALL UNIT WIDTHS TO INCLUDE 6' SIDE OVERHANG ONE SIDE OR ONE 3 OVERHANG ON EACH SIDE MAXIMUM. © CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. JACOBSEN HOMES PC P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 CALCS. G _ O 1 _ OF, 02 ENGIN yVVMsT�((�lj����i� ' • � 910334 � ' • 'CC vaTATE of .:A' THESE SPEdFIWIMIS AND DRAVMGS ARE OAKUM PROMTARY. AND COtiWTIAL MATERIALS OF .NOODSEN MANUFACTURING lwAXIMS ARE PRQVM 70 WE r fdt PURPOSES WO UM BE "p, CONf10Q:RAL ANO SECRET Rm onm ALL ZONES ALL EXPOSURES 20 PSF' ROOF 10 PSF D.L. APPROVED BY 000 . r ON P INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS MAR 0 1 1999 . . A.T. I ,, "- 2-8-99 A FOOTER SPECS CHART SU-01-0040 r� MOBILE HOME SET-UP DIM. 'A' DIM. 'B' COLUMN #1 COLUMN #2 COLUMN #3 COLUMN SUPPORT SPANS TO PROPERLY SIZE PIERS LOCATED AT RIDGE BEAM SUPPORT COLUMNS, SURVEY THE ARRANGEMENT OF THE ROOMS IN THE MOBILE HOME TO LOCATE THE OPENINGS ALONG THE MARRIAGE WALL OF THE HOME. MEASURE EACH OPENING IN THE MARRIAGE WALL PAYING ATTENTION PARTICULARLY TO OPENINGS GREATER THAN 4 FEET WIDE. IN THE EXAMPLE ABOVE TO DETERMINE THE SPAN FOR COLUMN #1 SIMPLY USE DIMENSION 'A'. TO DETERMINE THE SPAN FOR COLUMN #2 ADD DIMENSION 'A' AND DIMENSION 'B' TOGETHER. THE SPAN FOR COLUMN #3 CAN BE DETERMINED THE SAME WAY AS COLUMN #1 SIMPLY USE DIMENSION 'B'. ONCE THE COLUMN SPANS HAVE BEEN DETERMINED, FIND THE CORRESPONDING PIER FOOTING SIZE IN THE CHART (SU-01-0030). ❑❑❑❑ ❑❑■❑ORIGINAL, JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING TITLE- COLUMN SUPPORT SPANS ❑„❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-03-0001 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 • RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 23 SET UP NOTES (CLOSE UP) YOUR NONE 18 EQUIPPED WITH A FACTORY INSTALLED HATE LINE QASKET. THE MATE LINE GASKET MUST BE INSPECTED BEFORE BRINGING THE HOME SECTIONS TOGETHER -IF THE GASKET IS DAMAGED, IT MAY BE REPAIRED WITH A FABRIC TYPE TAPE, AND IF DISLODGED, IT MUST BE REATTACHED. THESE ARE (3) SUGGESTED (NOT REQUIRED) ITEMS TO HELP ELIMINATE AIR INFILTRATION. 1. FABRIC TYPE TAPE ADHERED TO BOTH SECTIONS BEFORE APPLYING ON -SITE FINISH MATERIALS. 2. THERMO-PLY STRIPS OR EQUIVALENT (2" WIDE MIN.) FASTENED TO BOTH SECTIONS WITH NAILS OR STAPLES BEFORE APPLYING EXTERIOR FINISH MATERIALS. (NOTE: THE ROOF IS MATERIAL AND APPLICATION SPECIFIC.) 3. SMALLER GAPS APPROX. 1/4" WIDE MAY BE SEALED WITH A BEAD OF LATEX CAULK. (NOTE: A FOAM SEALANT MAY BE USED IN LIEU OF A LATEX CAULK.) BEFORE SETTING MULTIPLE WIDE UNITS, THE CLOSE-UP PLASTIC SHIPPING MATERIAL MUST BE REMOVED FROM ALL EXTERIOR WALLS OF ALL SECTIONS. THE SHIPPING PLASTIC MAY BE LEFT IN PLACE ON ALL MATING OR MARRIAGE WALLS OF EACH SECTION, BUT THE PANEL STRIPPING MATERIAL SECURING THE CLOSE-UP SHIPPING PLASTIC MUST BE REMOVED TO ALLOW THE MULTIPLE WIDE SECTIONS TO BE BROUGHT TOGETHER WITH MINIMUM GAPPING BETWEEN THE SECTIONS. THE SHIPPING PLASTIC IS TO BED REMOVING SHIPPING STRIPS). AFTER THE SECTIONS ARE SET TOGETHER THE CLOSE-UP PLASTIC, IF LEFT ON THE MARRIAGE WALLS, IS TO BE CUT OUT AT ALL OPENINGS TO THE OTHER SECTIONS. WHEN THE HOME'S RETURN AIR GRILLE IS LOCATED IN THE MARRIAGE WALL, THE FRAMING IS TO BE SEALED NTH LATEX CAULK. OR FOAM SEALANT. AFTER REMOVAL OF THE GALVANIZED WIND DEFLECTOR(S) LOCATED ON THE ROOF AT THE HITCH END OF EACH SECTION OF THE HOME, SEAL ALL FASTENER PENETRATIONS OF THE ROOF SHINGLES WITH A ROOFING CEMENT OR OTHER SUITABLE MATERIAL. THE GALVANIZED WIND DEFLECTOR IS TO BE USED FOR THE ROOF CLOSE-UP, SEE AD-FA-0025 (AD-FA-0026 FOR TRIPLE WIDES). NOTE: BEFORE INSTALLING A CEILING FAN, INSTALL A 4 CU. IN. MINIMUM BOX EXTENSION. (CHECK FACTORY INSTALLED CEILING BOX FOR LABELING INDICATING SUITABLE FOR DIRECT ATTACHMENT OF CEILING FAN FIXTURE -IF NOT LABELED AS BEING SUITABLE, YOU MUST INSTALL A HOOK TYPE CEILING FAN -INSTALL HOOK THROUGH BOX INTO LUMBER BACKER BEHIND FAN BOX.) THE SAFETY CHAIN FOR ALL EXTERIOR OUTSWING DOORS SHALL BE INCLUDED IN THE SET-UP KIT. THE SAFETY CHAIN SHALL BE INSTALLED WHEN THE HOME IS SET-UP. INSTALL THE SAFETY CHAIN PER THE MANUFACTURERS SPECIFICA11ONS INCLUDED WITH THE SAFETY CHAIN HARDWARE. - FASTEN ALL EXTERIOR SIDING TRIM WITH 7/16" X 1" x 16 GA. STAPLES (OR EQUIVALENT) 6" O.C. MAXIMUM THROUGH SHEATHING INTO WALL OR FLOOR FRAMING. (UNDER HOME VENTILATION) WHEN ENCLOSING THE SPACE FROM THE BOTTOM OF YOUR HOME TO THE GROUND (SKIRTING, FOUNDATION WALLS, OR OTHER METHODS) THE AMOUNT OF VENTILATION REQUIRED IS TO BE DONE TO THE LOCAL CODES AND INSPECTED BY THE AUTHORITIES HAVING JURIDICTION. NOTICK DRAWN BY: DAIS •LETTER: JACOBSEN HOMES DOESE�,S AM MIUM A� M.T. 12-22-94 010GRAI, PROPRETARY, AND COlf NnAL DRAWING TULL YAIMALS OF JACOBSEN YAIWACTHMG SET UP NOTES. P.O. BOX 368 M SM YA1ERM ARE PROVW TO THE SAFETY HARBOR, FLORIDA 34695 AEMW FOR SITOF PursDgs AND WST BE . DRAWING NUMBEM SU-05-0001 PHONE (727) 726-1138 MY O FONK AND tWO nM a� r7.1 EXTERIOR FINISH CLOSE-UP SOFFIT AND FASCIA APPLICATION DETAIL METAL DRIP EDGE SOFFIT MATERIAL FASCIA MATERIAL LAP RECEIVER (J CHANNEL) NOTES: 1. ALL MATERIALS REQUIRED FOR ON SITE COMPLETION OF THE LAP SIDING APPLICATION IS SHIPPED INSIDE THE HOME WITH THE SET—UP KIT. 2. FIRST LOCATE AND SECURE THE SOFFIT MATERIAL TO EACH SECTION OF THE HOME WITH EITHER STAPLES, NAILS, OR SHEET METAL SCREWS 6" 0. C. 3. NEXT LOCATE AND SECURE THE FASCIA MATERIAL IN THE SAME MANNER AS LISTED ABOVE FOR THE SOFFIT. 4. THEN COMPLETE THE APPLICATION OF BOTH THE METAL DRIP EDGE AND THE LAP SIDING RECEIVER. 5. AFTER ALL PARTS HAVE BEEN JOINED AT THE MATING EDGES OF EACH SECTION OF THE HOME, BEGIN WITH THE LAP SIDING APPLICATION. START THE LAP SIDING APPLICATION AT THE BOTTOM OF THE HOME AS SHOWN IN THE LAP SIDING APPLICATION DETAIL BELOW. ALL TRIM AROUND OPENINGS (ie. WINDOWS AND DOORS) IS COMPLETED BEFORE THE HOME IS SHIPPED. LEAVE AMPLE ROOM AT ALL TRIM FOR THE LAP SIDING TO EXPAND AND CONTRACT WITH TEMPERATURE CHANGES. FOR ANY .ADDITIONAL INFORMATION REQUIRED SEE THE MANUFACTURERS INSTALLATION INSTRUCTIONS PLACED INSIDE THE SET—UP KIT SHIPPED WITH THE HOME. LAP SIDING FASTENING: 1. SECURE HORIZ. LAP SIDING W/ MIN. 7/16" X 1" X 16 GA. STAPLE`. 0. C. MAXIMUM THROUGH SHEATHING INTO STUD. SECURE ALL EXTI TRIM W/ MIN. 7/16" x 5/8" x 16 GA. STAPLES AT 6" 0. C. MAXIA 2. WITH METAL LAP STAPLE CROWNS MAY BE EITHER PARALLEL OR PERPENDICULAR TO NAILING FLANGE WITH BOTH LEGS OF STAPLE PENETRATING THE NAILING FLANGE. 3. WITH VINYL SIDING STAPLE CROWNS TO BE PERPENDICULAR TO NAILING FLANGE WITH ONE LEG CENTERED IN SLOT AND OTHER LEG ON OUTSIDE OF NAILING FLANGE WITH APPROX. 1/32" SPACE BETWEEN STAPLE CROWN AND NAILING FLANGE. 4. ALL FASTENERS TO BE WEATHER RESISTANT. BOTTOM STARTER STRIP HOOK STARTEF. " STARTER STRIP LAP SIDING APPLICATION DETAIL ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE: REV. LETTE ❑❑■❑ THESE SPECIFICATIONS AND DRAWINGS ARE S.A. 12-22-94 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PROVIDED TO THE EXTERIOR FINISH CLOSE-UP ❑❑❑❑ PHONE 727 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND.0l1OT BE DRAWING NUMBER: KEPT CONFIDENTIAL AND SECRET FROWOTHERS. SU-05 0020 .27 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION SEE OTHER DETAILS (SU-05-0031 THRU 0034) FOR PLAN. VIEW DETAILS IDENTIFING AREAS REQUIRING EXTERIOR SIDING TO BE SITE INSTALLED. SEE SU-05-0020 FOR LAP SIDING FASTENING, AND SOFFIT AND FACIA APPLICATION. ALL AREAS WHERE THE EXTERIOR SIDING MATERIALS EXTEND ACROSS THE MATING LINE BETWEEN MULTIPLE WADE UNITS ARE REQUIRED TO BE FINISHED ON SITE TO PREVENT A CONTINUOUS SEAM IN THE EXTERIOR SIDING LOCATED AT THE MATING LINE(S) OF THE HOME. ALL TRIM AND EXTERIOR SIDING MATERIALS ARE PROVIDED IN- THE HOME SET—UP KIT FOR COMPLETION OF ALL EXTERIOR SIDING APPLICATIONS FOR THE HOME. THE STARTER STRIP FOR THE LAP SIDING APPLICATION IS INSTALLED AT THE FACTORY TO ENSURE STRAIGHT ALIGNED APPLICATION OF THE SIDING. ALL TRIM MATERIALS NOT REQUIRING FASTENING TO MORE THAN ONE SECTION OF MULTIPLE SECTION HOMES IS ALSO FACTORY INSTALLED TO ENSURE PROPER CLEARANCES AND AN ASSURED MATCH TO THE REMAINDER OF THE HOME. ALL TRIM MATERIALS SECURED TO MORE THAN ONE SECTION OF THE HOME ARE TO BE FASTENED TO THE WALL FRAMING MEMBERS WITH MIN. 7/16" X 5/8" X 16 GA. STAPLES OR 1" ROOFING NAILS 6" O.C. MAXIMUM. TAKE CARE IN LOCATING TRIM MATERIALS TO ENSURE PROPER ALIGNMENT WITH THE FACTORY INSTALLED MATERIALS. ALL FASTENERS USED MUST BE. WEATHER RESISTANT TO INSURE DURIBILITY. ENCLOSED WITH THE EXTERIOR SIDING MATERIALS ARE THE MANUFACTURERS INSTALLATION INSTRUCTIONS DETAILING THE RECOMENDED INSTALLATION PROCEDURES AND SPECIFICATIONS FOR THE TYPE OF SIDING BEING USED ON THE HOME. CAREFULLY EXAMINE THE MANUFACTURERS INSTALLATION INSTRUCTIONS BEFORE ANY ATTEMPT TO COMPLETE THE REQUIRED INSTALLATION OF THE EXTERIOR SIDING MATERIALS. SHOULD FOR ANY REASON THE MANUFACTURERS INSTALLATION INSTRUCTIONS BE LOST OR MISSING, CONTACT JACOBSEN HOMES AT 901 4th Street North Safety Harbor, Florida 34695 OR CALL (813) 726-1138 FOR REQUESTING THE INSTALLATION INSTRUCTIONS. SKIRTING MUST BE ATTACHED IN A MANNER SO THE VINYL WILL SLIDE (EXPAND AND CONTRACT). WHEN 6 MIL PLASTIC UNDER HOMES, THE VENTILATION OF THE CRAWL SPACE CAN BE REDUCED TO 1 SQUARE FEET OF VENTILATION PER EVERY 1500 SQUARE FEET. ❑❑❑❑ JACOBSEN HOMES NOTICE: TNLSE sPEc�FICAnaNs AM DRAwLNcs ARE DRAWN BY: O.A. DATE 06-06-94 REV. LET1ETi: P.O. BOX 368 OR MA4 PWRETARY, AND CONFIDWAL MATERIALS OF JACOM MANUFACTUPoNG DRAWING TITLE: EXTERIOR SIDING APPLICATION n A HOEtILIE] INC. SUCH MATERIALS ARE PROYDED TO THE SAFETYHONER( 7) 726ID 138�95 I�T FOR AL AM RUM R M p H DRAWING NUMBER: SU=05-0030 (09-30-08) 28 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION (FOR SLIP UNIT MULTIPLE WIDES) I MATING LINE OF UNITS I I SITE INSTALLED EXTERIOR SIDING I I MATING LINE OF UNITS I SITE INSTALLED INSI[ CORNER POST SITE INSTALLED EXTERIOR SIDING ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE: REV. LETTER: THESE SPECIFICATIONS AND DRAWINGS ARE S.A. 6-6-94 ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ MATERIALS OF MANUFACTURING P.O. BOX 368 INC. SUCH MATERIALSRIALS ARE ARE PRONGED TO THE EXT.SID.APPL. FOR SLIP UNIT SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-05-0031 29 (��i►-•rrdssNl !2•uats 1,1N.11�:nFJ.1 1L (K IW-) '?0,0)1-jdnJ . b1,4 XL I•tJ.1C't 5ar71y o1Q�1��9�0) ._ z �aN q-�i f'a� Ott s ' tIt x• L7�ll-i _ ti 1 • !l 711H k%NTPi4Vj-�, ONI WINK LN A8 03A0addd �� 0 IC4 APPROVED By . JUL i 3 1 7NT;14 „meow ,N� -. I nil �L! �?l OtJ wavER vr►.:`A.Srvi�1G) jrJllfpOy.� . r �SL42J F Z:2gm yl tJ'iL. �lDl IJ � I (�S?�Lr✓P-i 1 Gl� ��P F ��) IG►�cRnop *p , UG,,4XYIr✓"X2.2.° �h v'c� c>; • iGts,�>cVlr��'r'h 1ES 3-7I0'o.c.OR Vi=-fzjlC�d•- �'ticL- _ZONE 2 [�tJD .3 ' � ��•c171 ~r. A•5 J Ep I p��+L I- IloL-ram x-V1 rJr�tzah�! x 2i�2� � I Co"o.G. I IJrDyj7J)�j CMlti1•) Su--oS�oo33 -7A-,b?r>eN dA —:'7i14,(94 thl�r by k Ca Lid-p�-�= ►�1"S Rev. .... rrt" AANYL --7iTM -1NSTP L.hrOrL : MOBILE HOME SET-UP SHUTTER INSTALLATION: SHUTT IRS ARE NORMALLY FASTENED BY SCREWING DIRECTLY THROUGH THE VINYL SIDING. THIS TENDS TO RESTRICT SIDE —TO —SIDE MOVEMENT OF THE VINYL SIDING PANELS. HOWEVER, SEVERAL THINGS CAN BE DONE TO ELIMINATE BUCKLING OR OIL CANNING OF THE VINYL SIDING IN THESE AREAS: A. WHEN PANELS RUN FROM WINDOW AREA TO A CORNER POST OR OR J—CHANNEL (OR ANY TYP. VINYL SIDING TRIM) AT THE OPPOSITE END, BE SURE TO LEAVE PROPER CLEARANCE IN THE 'POCKET" — THEN SIDING WILL EXPAND TOTALLY IN THAT DIRECTION. B. TWO SHUTTERS BETWEEN WINDOWS: THE PANELS THAT WILL BE RESTRICTED BY THE SHUTTER SCREWS SHOULD BE SHORTER LENGTHS (SEAM BETWEEN WINDOWS — NOT ONE CONTINUOUS PIECE OF VINYL) — SIMPLY OVERLAP TWO PANELS IN THIS AREA. PANELS WILL THEN EXPAND TOWARD THE OVERLAP JOINT (SEE DETAIL "A"). OR STAGGER THE SHUTTER SCREWS — INSTALL FIRST SHUTTER, TAKE NOTE OF WHICH PANELS ARE RESTRICTED BY THE SCREWS. THEN INSTALL THE OPPOSITE SHUTTER, POSITION THE SCREWS FOR THIS SHUTTER THROUGH PANELS EITHER ABOVE OR BELOW THE PANELS RESTRICTED BY THE SCREWS FROM THE FIRST SHUTTER. BY DOING THIS THE PANELS OF VINYL SIDING WILL BE ABLE TO EXPAND IN AT LEAST ONE DIRECTION, SO LONG AS PROPER CLEARANCE HAS BEEN MAINTAINED IN THE "POCKET" AREA OF THE CHANNEL. (SEE DETAIL "B") DETAIL "A" NOTICE: urtnmv c ❑❑❑❑ JAC 0 B S E N HOMES THESE SPECIFICATIONS AND DRAWNGS ARE ❑❑.❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING ❑„❑ P.O. BOX 366 INC. SUCH MATERIALS ARE PRONDED TO THE MUST BE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING 32 DETAIL "B" S.A. I ...... 6-6-94 SHUTTER INSTALLATION SU-05-0034 MOBILE HOME SET-UP 71EDOWNS THERE ARE TWO TYPES OF WIND THAT CAUSE DAMAGE: HORIZONTAL AND UPLIFT. YOUR HOME IS DESIGNED FOR THE HURRICANE ZONE (ZONE III). IF YOU FOLLOW OUR RECOMMENDATIONS YOU WILL PROTECT YOUR HOME FROM BOTH TYPES OF WIND FORCES. IN TIEING DOWN YOUR HOME, YOU MUST USE MATERIALS OF ADEQUATE STRENGTH AND SPECIFICATIONS. ANCHORING EQUIPMENT- (LOAD RESISTANCE) ANCHORING EQUIPMENT SHALL BE CAPABLE OF RESISTING AN ALLOWABLE WORKING LOAD EQUAL TO OR EXCEEDING 3.150 POUNDS AND SHALL BE CAPABLE OF WITHSTANDING A 50 PERCENT OVERLOAD (4.725 POUNDS TOTAL) WITHOUT FAILURE OF THE ANCHORING EQUIPMENT. ANCHORING EQUIPMENT- (WEATHERIZATION) ANCHORING EQUIPMENT (STRAPS, ETC...) EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIORATION AT LEAST EQUIVALENT TO THAT PROVIDED BY A COATING OF ZINC ON STEEL OF NOT LESS THAN 0.30 OUNCES PER SQUARE FOOT OF SURFACE COATED, AND IN ACCORDANCE WITH THE FOLLOWING: SLIT OR CUT EDGES OF ZINC -COATED STEEL STRAPPING NEED NOT BE ZINC COATED. TIE -DOWN STRAPS SHALL BE TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING, 1, 1/4 INCHES WIDE AND 0.035 INCHES IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ANCHORING NOTE' THERE IS A TENDENCY FOR THE TOP OF THE ANCHOR ROD TO DEFLECT AND MOVE OR 'SLICE" THROUGH THE SOIL WHEN LOADED WITH THE FRAME TIE. THIS IS NOT DESIRABLE. SINCE IT PERMITS THE MOBILE HOME TO BE DISPLACED DOWNWIND AND TEND TO SLIDE OFF THE PIERS. TO MINIMIZE DEFLECTIONS. AUGER -TYPE AND OTHER ANCHORS USING STEEL RODS SHOULD BE PUT ON AT AN ANGLE SO THEY ARE MORE IN LINE WITH THE DIRECTION OF PULL. THIS CAN BEST BE ACCOMPLISHED BY INSTALLING THE ANCHORS PRIOR TO PLACEMENT OF THE MOBILE HOME ON THE LOT. IF VERTICAL ANCHORS ARE DESIRED. THE ANCHOR MUST BE LISTED FOR USE VERTICALLY AT THE CAPACITY REQUIRED FOR THE STRAPPING BEING ATTACHE. APPROVED BY INJUL 1 3 INC. mm cm me CAUTION: DO NOT PRETENSION TIE -DOWN STRAPS ON ONE SIDE OF THE HOME ONLY. IF i-NSION IS NOT APPLIED TO TIE -DOWNS ALTERNATELY ON OPPOSITE SIDES, THE HOME MAY BE PULLED OFF THE SUPPORTS. J ' � ... v 6-6-94 SU-07-0001 33 TIE -DOWN STRAPS SEE ADDENDUM TO SET-UP MANUAL FOR SPECIFIC TIE -DOWN INFORMATION. THE DETAILS IN THIS MANUAL ARE ONLY TYPICALS, SEE ADDENDUM FOR SPECIFICS. DANGER: DO NOT PRETENSION TIE -DOWN STRAPS ON ONE SIDE OF THE HOME ONLY. IF TENSION IS NOT APPLIED TO TIE -DOWNS ALTERNATELY ON OPPOSITE SIDES, THE HOME MAY BE PULLED OFF THE SUPPORTS. ❑❑❑❑ ❑❑.❑ORIGINAL, JACOBSEN HOMES NOTICE: THESE SPECIRCATIONS AND DRAWNGS ARE PROPRIETARY, AND CONFlOENTIAL MATERIALS OF JACOBSEN* MANUFACTURING DRAWN BY: S.A. DATE: 7-ZO-94 REV. LEVER: _ DRAWING TITLE: TIE -DOWN STRAPS ❑,E❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-07-0002 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REOPlENT FOR SPECISC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS 00 :34 MOBILE HOME SET-UP/ELECTRICAL ELECTRICAL CONNECLIONS BETWEEN HOME SECTIONS NOTE: NO ELECTRICAL POWER SHOULD BE CONNECTED TO HOMES WHILE MAKING ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. MATERIAL SUPPLIED 1. APPROPORATE NUMBER OF JUNCTION BOXES TO MAKE 2 CONNECTIONS PER JUNCTION BOX. (SHIPPED LOOSE IN THE SET-UP KIT) 2. WIRE NUTS. 3. JUNCTION BOX COVERS. INSTRUCTIONS A. SECURE JUNCTION BOXES UNDER HOME. B. WIRES HAVE BEEN COLOR CODED; SIMPLY MATCH UP COLOR CO-ORDINATED WIRES WITHIN A JUNCTION BOX AND CONNECT WITH WIRE NUTS. C. PLACE COVERS OVER JUNCTION BOXES. OMITTED CEILING FIXTURES FIXTURES TO BE INSTALLED AT THESE LOCATIONS MUST BE A TWO WIRE FIXTURE WITH GROUND. INSTALL ALL FIXTURES BEFORE TURNING ON MAIN BREAKERS. NOTE: SEE BELOW FOR SERVICE CONDUCTOR SIZES GROUND (GREEN OR BARE) WIRE TO GROUND BAR HOT LEADS (RED & BLACK) CONNECTED TO MAIN BREAKER NEUTRAL (WHITE) WIRE TO NEUTRAL BUSS MINIMUM CONDUIT SIZES:---- CONDUIT DROP FROM HOME - EXTEND 1/2" MINIMUM - 150 AMP TO BELOW GROUND LEVEL OR SEE 2" MINIMUM - 200 AMP LOCAL CODES TYPICAL ELECTRICAL CONNECTIONS CROSS -OVER CONNECTIONS CROSS -OVER INFORMATION APPLIES TO MULTI -SECTION UNITS CROSS -OVER WIRES ARE COLOR -CODED SERVICE CONDUCTORS MAIN BREAKER HOT I NEUTRAL GROUND 150 2 NO. 1 1 NO. 1 NO. 6 200 2 NO. 2 0 1 NO. 2 0 NO. 6 NOTE: ABOVE SERVICE CONDUCTORS ARE FOR COPPER ONLY. FOR COPPER -CLAD ALUMINUM REFER TO LOCAL CODES ELECTRICAL PANEL LABEL THIS LABEL IS LOCATED ON OR NEAR THE ELECTRICAL PANEL THE MINIMUM SIZE JUNCTION BOX ATTACHED TO THE CONDUIT FOR SERVICE CONDUCTORS ARE: 9" X 9" X 4" - 150 AMP OR 12" X 12" X 4" - 200 AMP JACOBSEN HOMES NOTICE: THESE SPEWCATIONS AND DRAWINGS ARE DRAWN BY: B.C.K. DATE 03-30-12 REV. LETTER: DRAWING TITLE: SET-UP ELECTRICAL U10IMPFE) P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING B INC. SUCH MATERIALS ARE PRONDED TO THE DRAWING NUMBER: S0-09-0001 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECMT FOR SPECIFIC PURPOSES AND MUST DE KEPT CDNRDENTIAL AND SECRET FROM OTHERS. 35 ELECTRICAL CROSS -OVER & TESTING PROCEDURES --MARRIAGE LINE I i i NOTCHED MARRIAGE WALL PERIMETER JOISTS = .92" DEEP NOTCH MAX. ELECTRICAL WIRING FROM ONE SECTION TO BE HOOKED —UP IN JUNCTION BOX(S) ELECTRICAL JUNCTION BOX(S) FASTENED TO TRANSVERSE FLOOR JOIST. AFTER ALL ELECTRICAL WIRING CONNECTIONS ARE MADE, SYSTEM MUST BE INSPECTED AND TESTED. (FOR CONTINUITY TEST PROCEDURES SEE SU-09-0020) TESTING THE POLARITY OF THE ELECTRICAL SYSTEM WILL REQUIRE TEST EQUIPMENT. CAPABLE OF DETERMING INCORRECT WIRING CONFIGURATIONS, AND ALSO SHOULD INCLUDE ADAPTERS FOR VARIOUS CONFIGURATIONS (POLARITY TESTER). USING THIS DEVICE ALL ELECTRICAL CONNECTIONS (INCLUDING OUTSIDE FIXTURES SUCH AS HEAT TAPE RECEPTACLE) ARE INDIVIDUAL TESTED TO ENSURE ALL CONNECTIONS HAVE BEEN PROPERLY MADE. A PIGTAIL CIRCUIT TESTER MAY BE USED AS AN ALTERNATE TEST METHOD FOR LIGHT FIXTURES. PIGTAIL TEST IS AS FOLLOWS: HOT IN BASE OF SOCKET TO GROUNDED FIXTURE CANOPY (LIGHT MUST LIGHT), NEUTRAL TO FIXTURE CANOPY (LIGHT MUST NOT LIGHT), AND A GROUND CHECK TO DETERMINE NO OPEN GROUND. FAILURE AT ANY FIXTURE REQUIRES REPAIR AND RETEST. NOTE: ALL GROUND LEADS ARE SECURED TOGETHER AND BONDED TO THE JUNCTION BOXES W/ THE LARGEST SIZE CONDUCTOR IN BOX. (ALL REQUIRED JUNCTION BOXES ARE SHIPPED LOOSE IN THE SET—UP KIT) NOTES: 1. ALL ELECTRICAL WIRING CONNECTIONS T0. BE MADE INSIDE LISTED JUNCTION B.OX(S) IN COMPLIANCE WITH N.E.C. — 2005 2. WIRING IN LISTED JUNCTION BOX(S) NOT TO EXCEED CAPACITY OF THE JUNCTION BOX(S) PER N.E.C. — 2005. 3. WIRING TO BE PROTECTED AND SECURED AT MARRIAGE WALL JOISTS WITH WIRE PROTECTOR PLATES INCLUDED IN SET—UP KIT. 4. ELECTRICAL CROSSOVER WIRING TO BE DONE ONLY BY QUALIFIED PERSONNEL. MATCHING IDENTIFIED CIRCUIT WIRING FROM EACH SECTION OF MULTIPLE WIDE HOMES. 5. AFTER WIRING CONNECTIONS HAVE BEEN MADE, REPLACE COVER ON JUNCTION BOX(S), AND REPAIR ANY CUTS OR VOIDS IN THE BOTTOM BOARD WITH DUCT TAPE. ❑❑❑❑ JACOBSEN HOMES N0T10 1NESE sPEaFiCAnONs AND DRIIIMNGS ARE DRAWN BY: D.M.T. DATE 05-25-06 REv. lET1ER DRAWING VUL- ELECTRICAL CROSS —OVER ❑❑;N� P.O. BOX 368 ORIGINAL, PROPMEMY, AND CONFRIENRAI. MATERIALS OF JACOBSEN MANUFACWPoNG %� 1`l ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 NC. SUCH MAISLU ARE PR VW TO THE RECFNNf FOR � PURPOSES AND MUST BE (09-29-08 DRAWING NUTABER: PHONE (813) 726-1138 KEPT CMU M M AND SECRET FROM OTHERS SU709-0010 ` 36 WIRE FROM TO GROUNDI #8 BARE C( OUTRIGGER MOBILE HOME SET-UP/ELECTRICAL GIRDLING WIRE MAY BE ATTATCHED TO ANY PART OF THE FRAME ASSEMBLY (NOT REQ'D TO BE ® OUTRIGGER). ANY APPROVED GROUNDING TERMINAL SECURED TO FRAME TO INSURE PROPER GROUND (METAL TO METAL CONTACT INSURED BY USING A STAR WASHER BETWEEN OUTRIGGER AND TERMINAL). TYPICAL ELECTRICAL GROUND NOTE: ALL EXPOSED NONCURRENT CARRYING METAL PARTS THAT MAY BECOME ENERGIZED SHALL BE EFFECTIVELY BONDED TO THE GROUNDING TERMINAL OR ENCLOSURE OF THE DISTRIBUTION PANELBOARD. A BONDING CONDUCTOR SHALL BE CONNECTED BETWEEN EACH DISTRIBUTION PANELBOARD AND AN ACCESSIBLE TERMINAL ON THE CHASSIS. NO. 8 BARE COPPER-" L APPROVED GROUNDING TERMINAL BOND WIRE (MINIMUM) ATTACHED TO OUTRIGGER OR I -BEAM (TYPICAL EACH UNIT). TYPICAL ELECTRICAL BONDING GROUNDING AND CONTINUITY TEST THE GROUNDING CONTINUITY TEST MUST BE PERFORMED BEFORE THE FEEDER CONDUCTORS ARE CONNECTED. PERFORM THE FOLLOWING TEST AFTER ALL STRUCTURAL ASSEMBLY, METAL AND TRIM INSTALLATION IS FINISHED: A. CONNECT ONE CLIP OF A FLASHLIGHT CONTINUITY TESTER TO A CONVENIENT GROUND (METAL SKIN, WINDOW FRAME ON METAL SKINNED UNITS, FLOOR DUCT RISER, SCREW HEAD ON RECEPTACLE OR SWITCH PLATE, ETC.) AND TOUCH THE OTHER CLIP TO EACH LIGHT FIXTURE CANOPY (WHERE LIGHT IS MOUNTED TO CEILING OR WALL). THE CONTINUITY TESTER SHOULD LIGHT IF EACH FIXTURE IS PROPERLY GROUNDED. B. REPEAT THESE PROCEDURES FOR ALL DIRECT WIRED APPLIANCES AND FIXTURES. C. USING THE SAME PROCEDURES, CHECK THE CONTINUITY BETWEEN THE FOLLOWING: 1. BETWEEN METAL ROOF AND STEEL FRAME. 2. BETWEEN METAL SKIN AND STEEL FRAME. 3. BETWEEN STEEL FRAME AND GAS PIPING. D. ANY LOSS OF GROUNDING CONTINUITY FOUND IN THE ABOVE WILL REQUIRE INVESTIGATION, CORRECTION, AND RETESTING FOR CONTINUITY. ❑❑❑❑ JAC 0 B S E N HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROMDED TO THE TYPICAL ELECTRICAL GROUND ❑❑❑❑ SAFETY HARBOR, FLORIDA 34595 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-09-0020 37 EXTERIOR LIGHT FIXTURE INSTALLATION BE SURE ELECTRICAL SERVICE IS DISCONNECTED BEFORE COMING IN CONTACT WITH ELECTRICAL CONDUCTORS FIXTURE FLASHING RING (THIN WHITE FIBROUS RING) WHITE (NEUTRAL) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT BLACK (HOT) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT 0 EXTERIOR ELECTRICAL BOX BARE (GROUND) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT EXTERIOR LIGHT FIXTURE (LISTED FOR EXTERIOR USE) BEFORE ELECTRICAL SERVICE IS CONNECTED TO THE HOME, INSPECT THE EXTERIOR OF THE HOME AND LOCATE ALL THE EXTERIOR LIGHT LOCATIONS TO BE INSTALLED ON SITE. (ALL EXTERIOR LIGHT FIXTURES IN PORCH AND OTHER AREAS NOT ALONG THE EXTERIOR WALL AREAS OF THE HOME ARE INSTALLED AT THE FACTORY). THE EXTERIOR LIGHT LOCATIONS CAN BE IDENTIFIED AS EXTERIOR ELECTRICAL BOXES IN THE WALLS USUALLY LOCATED ADJACENT TO EXTERIOR DOORS THAT ARE COVERED WITH BLANK (SOLID) COVERS. TO INSTALL THE EXTERIOR LIGHT FIXTURES, REMOVE THE BLANK COVERS FROM THE ELECTRICAL BOXES AND FEED THE THREE WIRES (IDENTIFIED IN THE DETAIL ABOVE) THROUGH THE FIXTURE FLASHING RING BEFORE THE CONNECTIONS OF THE CONDUCTORS ARE MADE. THE FIXTURE FLASHING RINGS MUST EXTEND FROM THE OPENING OF THE ELECTRICAL. BOX TO THE OUTERMOST EDGES OF THE EXTERIOR LIGHT FIXTURE (EXCESS AMOUNT OF THE FLASHING RING MAY BE TRIMMED OFF AFTER THE FIXTURE IS SECURED TO THE ELECTRICAL BOX). TO INSURE AGAINST THE POSSIBILITY OF AN ELECTRICAL SHOCK, ALL ELECTRICAL CONNECTIONS SHOULD BE DONE WITH THE ELECTRICAL SERVICE SHUT OFF TO THE HOME. THE WIRE NUTS REQUIRED FOR SECURING THE WIRES WILL BE FOUND INSIDE THE ELECTRICAL BOX FOR THE FIXTURE (THESE WIRE NUTS ARE INSTALLED AT THE FACTORY TO CAP THE CONDUCTORS IN THE ELECTRICAL BOX). THE FIXTURE FLASHING RING IS LOCATED IN THE SHIPPING KIT INSIDE THE HOME. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING TITLE: LIGHT FIXTURE INSTALLATION ❑❑■❑ P.O. BOX 368 ORIGINAL. PROPRIETARY. AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING ❑„❑ INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-09-0030 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 38 MOBILE HOME SET-UP PLUMBING CONNECTIONS CHECK WATER AND DRAIN LINES FOR ANY CONNECTIONS THAT MAY HAVE COME LOOSE DURING SHIPMENT. SHOULD YOUR HOME NOT BE EQUIPPED WITH A MASTER SHUT-OFF VALVE, ONE MUST BE INSTALLED BETWEEN THE HOME AND THE WATER SUPPLY. THE WATER SUPPLY SYSTEM IS DESIGNED FOR A MAXIMUM INLET WATER PRESSURE OF 80 PSI. IF THE LOCAL WATER SUPPLY PRESSURE TO WHICH THE HOME IS BEING CONNECTED EXCEEDS 80 PSI, A PRESSURE REDUCING VALVE SHOULD BE INSTALLED TO LIMIT THE SUPPLY PRESSURE. WHEN HOMES ARE SET IN AREAS SUBJECT TO FREEZING THE EXPOSED WATER SUPPLY LINES MUST BE PROTECTED. AN ELECTRICAL RECEPTACLE IS LOCATED ON THE UNDERSIDE OF THE HOME NEAR THE WATER INLET, AND NEAR ANY CROSSOVER LOCATION WHERE THE WATER LINES ARE EXPOSED. THESE ELECTRICAL RECEPTACLES ARE FOR THE CONNECTION OF AN ELECTRICAL HEAT TAPE. HEAT TAPE USED MUST BE LISTED FOR USE WITH MOBILE HOMES. FOR MULTIPLE SECTION HOMES WITH PLUMBING IN MORE THAN ONE SECTION, LOCATE AND CONNECT THE WATER CROSSOVERS LOCATED UNDER THE FLOOR ALONG THE MARRIAGE LINE BETWEEN THE SECTIONS. TURN THE WATER SUPPLY ON AND CHECK FOR LEAKAGE. CAUTION: DO NOT TURN THE POWER ON TO THE WATER HEATER UNTIL THE TANK IS FULL OF WATER. CONNECT DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE TO COMPLY WITH LOCAL PLUMBING CODES. GAS PIPING HOMES WITH GAS PIPING HAVE BEEN FACTORY TESTED FOR LEAKS, HOWEVER, BEFORE CONNECTING THE GAS SUPPLY TO THE SYSTEM ANOTHER PRESSURE TEST IS REQUIRED TO INSURE THAT THERE ARE NO LEAKS AFTER THE HOME HAS BEEN TRANSPORTED AND SET-UP. 1. CLOSE OFF ALL THE GAS APPLIANCE SHUT OFF VALVES. 2. ATTACH THE GAS TEST FITTING GAUGE. 3. PRESUREIZE THE SYSTEM UNTIL 3 PSI OF AIR PRESSURE IS REACHED. 4. PRESSURE MUST BE MAINTAINED FOR 10 MINUTES WITHOUT ANY INDICATED PRESSURE LOSS. CAUTION: DAMAGE MAY RESULT IF THE SYSTEM IS OVER PRESSUREIZED, THE GAS PIPING SUPPLY SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM PRESSURE OF 14" WATER COLUMN (1 /2 PSI) AND NOT LESS THAN 7" WATER COLUMN (1 /4 PSI). THE GAS PIPING SYSTEM IS DESIGNED TO USE EITHER LIQUIFIED PETROLEUM GAS OR NATURAL GAS. BEFORE TURNING THE GAS ON: 1. BE SURE THE APPLIANCES IN YOUR HOME ARE DESIGNED FOR THE TYPE OF GAS BEING CONNECTED. 2. WHERE APPLICABLE ON MULTIPLE WIDE HOMES, LOCATE "QUICK -DISCONNECT" AND CONNECT. THE "QUICK -DISCONNECT" IS LOCATED UNDER THE FLOOR AT THE MARRIAGE LINE. 3. MAKE SURE ALL CONNECTIONS ARE TIGHT, AND ALL APPLIANCES ARE TURNED OFF. 4. AFTER THE GAS HAS BEEN CONNECTED AND TURNED ON, MAKE SURE ALL THE PILOT LIGHTS ARE LIT. ❑❑❑❑ JACOBSEN � HOMES NOSAN: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: D.M.T. DAIS 3-22-95 REV. LETTER: ❑❑�❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATMIAALS OF ACOBSEN MANUFACTURING DRAWING TITLE A P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE PLUMB. CON. &GAS TEST ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: SU-11 _0001 (09-29-08) 39 PLUMBING TESTS WATER SUPPLY PIPING TEST ALL PIPING IN THE WATER DISTRIBUTION SYSTEM SHALL BE SUBJECTED TO A PRESSURE TEST. (MULTI - WIDE UNITS SEE SU-11-0020A FOR CROSS -OVER CONNECTION) PRIOR TO TESTING BE SURE ALL PLUMBING FIXTURES ARE CONNECTED EXCEPT WATER HEATER. CLOSE ALL FAUCETS AND RAISE AND HOLD THE FLOAT ARM IN THE TOILET TANK TO SHUT-OFF LEVEL. ALL SHUT-OFF VALVES IN PIPING SYSTEM ARE OPENED FULLY (EXCEPTIONS ARE DISHWASHER AND ICE -MAKER SHUT-OFF VALVE WHICH WILL REMAIN CLOSED) TAKE THE HOT AND COLD SUPPLY LINES AT WATER HEATER AND (FOR TEST PROCEDURE. ONLY) CONNECT THEM TOGETHER. OR IF YOU CHOOSE YOU MAY TEST HOT LINES AND COLD LINES SEPARATELY (IN THIS CASE DO NOT CONNECT HOT TO COLD AT WATER HEATER). CONNECT TEST GAUGE AND THEN CONNECT SOURCE OF PRESSURE (AIR OR WATER MAY BE USED) TO PIPING SUPPLY SYSTEM.. PRESSURIZE SYSTEM TO 100 PSI NO LESS AND THEN ISOLATE / DISCONNECT SOURCE OF PRESURE. 100 PSI MUST BE MAINTAINED FOR AT LEAST 15 MINUTES. IF GAUGE SHOWS A DROP IN PRESSURE THERE IS A LEAK IN THE SYSTEM THAT REQUIRES REPAIR. AFTER REPAIR IS MADE RETEST THE SYSTEM, 100 PSI MUST BE MAINTAINED FOR AT LEAST 15 MINUTES. DISCONNECT HOT FROM COLD SUPPLY LINE AT WATER HEATER, AND CONNECT TO WATER HEATER. DRAINAGE SYSTEM TEST CONNECT ALL DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE PER ENCLOSED DRAIN LAYOUT OR TO COMPLY WITH LOCAL PLUMBING CODES. CAP OR PLUG THE MAIN DRAIN OUTLET. LOCATE THE LOWEST FIXTURE (USUALLY THE SHOWER), THIS WILL BE WHERE YOU NEED TO OBSERVE THE WATER LEVEL. INTRODUCE WATER INTO THE SYSTEM (SEE NOTE #2) UNTIL WATER REACHES DEPTH OF 2" MIN. IN LOWEST FIXTURE. THE TEST SHALL BE SUSTAINED FOR NO LESS THAN 15 MINUTES WITHOUT EVIDENCE OF LEAKS. VISUALLY CHECK ALL CONNECTIONS MADE ON -SITE FOR LEAKS (FACTORY CONNECTIONS HAVE ALREADY BEEN TESTED). IF WATER LEVEL IN LOWEST FIXTURE HAS NOT CHANGED WITHIN THE MINIMUM 15 MINUTES, AND THERE WAS NO EVIDENCE OF LEAKS AT FITTINGS, THEN THE DRAINAGE SYSTEM TEST IS COMPLETE. FAILURE TO MAINTAIN WATER LEVEL INDICATES A LEAK IN THE SYSTEM AND REQUIRES REPAIR AND RETESTING. NOTES: 1. HOME SHALL BE IN A LEVEL POSITION. 2. INTRODUCE WATER TO SYSTEM AT SINK, SHOWER OR TUB. DO NOT INTRODUCE WATER TO SYSTEM AT TOILET BOWL FOR THIS MAY TRAP AIR WITHIN THE SYSTEM. NOTICE: DRANK BY: DATE REV. LEM: ❑❑❑ ❑JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE D.M.T. 09-29-08 ORIGINAL, PROPRIETARY, AND CONRDENTIAL DRANING TITLE: ❑❑m❑ MATERIALS OF JACOBSEN'MANUFACIIRBNG - ❑,�❑ P.O. BOX 368 WC. SUCH MATEIM AM PROWAG TO THE PLUMBING TEST SAFETY HARBOR, FLORIDA 34695 Ir ww FOR MIX RI8m AND WIST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 IVT WDENTIAL AND SECRET FROM OTHERS. $U-11-0002 40. MOBILE HOME SET-UP SET-UP KIT PLUMBING FITTINGS r� B FITTING NAME: COUPLER SYMBOL ORIENTATION / USE COUPLING PIPE SPLICING DIRECTION OF FLOW FITTING NAME: SANITARY TEE SYMBOL ORIENTATION / USE SAN. TEE HORIZONTAL TO VERTICAL ONLY FITTING NAME: LONG TURN 90' ELL SYMBOL ORIENTATION /USE 90' ELL MAY BE USED IN ANY ORIENTATION CHECK THE INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED AND PLACEMENT OF FITTINGS, NOTE AS SHOWN IN THE DETAILS THE DIRECTION OF FLOW FOR FITTINGS. ALL PIPING REQUIRED TO FIT BETWEEN FITTINGS IS INCLUDED IN THE SET-UP MATERIALS. THE LENGTHS OF PIPE SHOULD BE CHECKED BEFORE CUTTING TO ENSURE THAT PROPER DROP-OFF IS REMAINING FOR COMPLETION OF PIPE RUNS. DRY FITTING ALL PARTS TOGETHER IS RECOMENDED BEFORE ANY FITTING AND PIPE JOINT IS GLUED. p _ff DIRECTION OF FLOW FITTING NAME: REDUCER BUSHING SYMBOL ORIENTATION / USE BUSHING REDUCE FITTING PIPE SIZE DIRECTION OF FLOW FITTING NAME: LONG TURN TEE WYE SYMBOL / USE LTTY MAY�BEUSED ORIENTATION SET-UP INSTRUCTION SYMBOLS O. = 1 1/2" DROP O = 1 1/2" DRY VENT 0 = 2" DROP 0 = 2" WET VENT O = 3" DROP O = 3" MAIN DRAIN - - - - = 1 1/2" DRAIN LINE � = =� = 2" DRAIN LINE = 3" DRAIN ,LINE NOTE: USE A GOOD QUALITY CLEANER AND CEMENT LISTED FOR USE WITH PVC PIPING CONNECTIONS. BE SURE TO FOLLOW THE MANUFACTURERS INSRUCTIONS ON THE CONTAINERS. ❑❑❑❑JACOBSEN ❑❑■❑ HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING V"' S.A. 6-6-94 DRAWING TITLE: SET-UP KIT. PL. FITTINGS ❑„❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: Su-1 1-001 O ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 4'1 MOBILE HOME SET-UP 2" WET VENT WITH NOT MORE THAN UNVENTED /� (1) FIXTURE DRAIN W.C. DROP / / 2" / D / ALT. VENTED W.C. 3" DROP / TYPICAL / 2" DROP 3 / / INDICATES BOTTOM OF HOME / / 1 1/2" DRY VENT 2" (SEE ALT. FOR UNVENTED / OPT. WET VENT / CONNECTION) @ �- INSTALL FULL SIZE W.C. DROP / / 1 1/2" 2" CLEAN -OUT IF SLOPE / / 3" 2 Q IS BETWEEN 1/8" & 3" O 1/4" PER FOOT USE O IF CLEAN- O3 p 3" TYPICAL OUT IS NOT NEEDED 3" O 1 1/2" DROP O 0 / / 3" / / 3" / 1 1/2" 1 1 /2" O �- MINIMUM SLOPE 3" / /j 1/8" PER FT. / 1 WITH CLEAN -OUT 1/4" PER FT. WITHOUT CLEAN -OUT FITTING SCHEDULE OA. VERT. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) 0 HORIZ. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) © © HORIZ. TO VERT. (1/4 BEND -LONG ELL) OD VERT. TO HORIZ. (LONG SWEEP 1/4 BEND) 3" O HORIZ. TO VERT. (SHORT TURN TY - SAN. TEE) TO ON SITE DRAIN CONNECTION TYPICAL ON SITE DRAIN CONNECTIONS 3/4" DROP FROM WATER HEATER 3/4" DROP / / SECTION 3/4" ELL / / 0,,-3/4" THREADED INLET / f / 3/4" TEE AND J FRESH WATER INLET FOR 3/4" THREADED 3/4" ELL SINGLE WIDES AND MULTI- NOTE: INLET - FIELD THE TWO EXAMPLES SHOWN ARE INSTALLED WIDES WITH PLUMBING IN TYPICAL FOR MOST MODELS. ONE SECTION ONLY SOME MODELS DEPENDING 3/4" CROSS-OVERS ON THE PLUMBING LAY -OUT FRESH WATER INLET FOR (FIELD INSTALLED) MAY HAVE A COMBINATION MULTI-WIDES WITH OF BOTH OF THE EXAMPLES SHOWN. PLUMBING IN MORE THAN ONE SECTION TYPICAL FRESH WATER ENTRANCES NOTICE: DRAWN BY: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS A D DRAWINGS ARE S.A, DATE: 6-6-94 ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONROENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING DRAIN SET-UP INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 REOPIENT FOR SPEORC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-11-0005 42 WATER LINE CROSS -OVER (SEE DETAIL BELOW) TYPICAL MARRIAGE LINE OF MULTIPLE WIDE HOMES TYPICAL FLOOR ASSEMBLY FLOOR JOIST MAY BE NOTCHED AT PLUMBING CROSS -OVER WATER CROSS -OVER (SEE ELECTRICAL SET-UP FOR SPECIFICATIONS). R-7 INSULATION MINIMUM AND BOTTOM BOARD OVER WATER CROSS -OVER LINES NOTE: NO HEAT TAPE RECEPT. REQUIRED AT INSULATED WATER CROSS -OVER. NOTES: 1. CONNECT WATER LINES TOGETHER AT ALL CROSSOVER LOCATIONS. 2. INSTALL R-7 MINIMUM INSULATION BLANKET OVER THE WATER CROSS -OVER LINES AND SECURE INTO PLACE WITH DUCT TAPE. 3. PLACE A PIECE OF BOTTOM BOARD MATERIAL LARGE ENOUGH TO COVER WATER CROSS -OVER LINES AND INSULATION AND SECURE TO FLOOR FRAMING MEMBERS WITH 1" X 1- X 16 GA. STAPLES _ MINIMUM AT EACH FRAMING MEMBER, AND TAPE OVER SEAMS WITH CLOTH DUCT TAPE OR EQUAL. ❑❑❑❑ ❑❑■❑ J AC 0 B S E N HOMES NOTICE: THESE SPECIFICATIONS AND ORAIMNGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWN BY: C.L.Y. DAIL: 10- 23- 95 HtV. LtIItK: ppp DRAWING TITLE: WATER CROSS -OVER ❑"❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-11 -0020 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. 43 MOBILE HOME SET-UP 6. A.C. CONNECTIONS JACOBSEN MOBILE HOMES ARE MADE AIR CONDITIONER READY, WHICH MEANS THE REGISTERS, SUPPLY DUCTS, AND RETURN AIR FACILITIES ARE ALREADY INSTALLED IN YOUR HOME. IN A MULTI — SECTION HOME THERE IS ONE SUPPLY DROP PER SECTION, AND ONE RETURN AIR DROP FOR THE ENTIRE HOME. CONNECT THE RETURN AIR DROP TO THE INTAKE SIDE OF THE AIR CONDITIONING UNIT, AND CONNECT THE SUPPLY DROPS REDUCER ' Y•' FITTING(S) (i.e., (1) 12" TO (2) 10") TO THE BLOWER SIDE. FOR SINGLE UNIT HOMES, THERE IS ONE SUPPLY DROP, CONNECT THAT ONE DROP DIRECTLY TO THE BLOWER SIDE OF THE AIR CONDITIONING UNIT. ALL CONNECTIONS BETWEEN THE AIR CONDITIONER AND DROPS CAN BE MADE WITH INSULATED FLEXIBLE DUCT. CHECK THESE ITEMS AFTER THE AIR CONDITIONER IS INSTALLED. 1. ALL DUCT WORK BELOW THE HOME IS INSULATED. . 2. ALL SEAMS ARE SEALED. 3. ALL CONNECTIONS ARE INSULATED AND TIGHT FITTING. 4. CROSS —OVER DUCT MUST BE SUPPORTED EVERY 4'-0" O.C. TYPICAL RETURN AIR DROP TYPICAL - SUPPLY DROP TYPICAL SUPPLY DROP REDUCER 'Y J FITTING AIR FLOW UNIT IS SHOWN WITH TWO SUPPLY AND ONE RETURN DUCT(S). THIS WILL VARY BY MODEL. MODELS MAY HAVE MORE OR FEWER SUPPLY OR RETURN DUCTS. IN ONE AIR CONDITIONER UNIT ! HANDLER, CONDENSER, AND COMPRESSOR) TYPICAL MULTIPLE SECTION A.C. CONNECTIONS NOTE: ON SOME MODELS THE SUPPLY AND/OR RETURN AIR DROPS PROVIDED ON THE HOME MAY BE LOCATED DIRECTLY OVER THE RUNNING GEAR (TIRE AND/OR.AXLE). ON HOMES WITH THE DROP LOCATIONS LOCATED ABOVE THE RUNNING GEAR IT IS NECESSARY TO REMOVE THE RUNNING GEAR BEFORE HOOKING UP THE SUPPLY AND/OR RETURN AIR DUCT FROM THE AIR CONDITIONER UNIT TO THE HOME. NOTICE: DRAWN BY: DATE ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWNGS ARE O.A. 06-06-94 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: LOS, ;�INC. SUCH OF ,M ARE MANUFACTURINGDOUBLE WIDE A.C. CONNECTIONS P.O. BOX 368 INC. SUCH MATEIiIAIS ARE PRONDm TO 7HESAFETY HARBOR, FLORIDA 34695 RECPIBIT FOR SKCFIC PURPM AID MUST BE DRAWING NUMBER: pp PHONE' (727) 726-1138 RDPT CONFDDNTUL AND SECREF MW OTNBRS SU-13-0001 4` REV. UTTER: A (09-30-08) MOBILE HOME SET-UP USE THE FOLLOWING INSTRUCTIONS WHERE APPLIED TO DUCTWORK PROVIDED BY JACOBSEN HOMES FOR AIR CONDITIONER INSTALLATION. CHECK THE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL ADDITIONAL DUCTS USED DURING AIR CONDITIONER HOOK—UP FOR RECOMMENDED INSTALLATION PROCEDURES FOR THE TYPE DUCT BEING USED. METHOD DETAILS CONNECTIONS SPLICES PRESSURE LIMITATIONS TAPE ONLY A) FOLD BACK JACKET AND INSULATION A) FOLD BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. FROM END OF DUCTS EXPOSING CORE. (FOR LOW B) SLIP CORE OVER FITTING AT LEAST B) INSERT ONE CORE INTO THE OTHER PRESSURE 1 1/2 INCHES. ABOUT THREE INCHES. NOT TO EXCEED C) APPLY DUCT TAPE* AROUND CORE AND C) APPLY DUCT TAPE* AROUND OUTSIDE CONNECTING 2 IN. W.G.) FITTING WITH AN EQUAL TAPE WIDTH ON OF CORE EDGE WITH EQUAL WIDTH ON EACH. EACH CORE. D) PULL BACK INSULATION AND JACKET D) BUTT INSULATION AND PULL JACKET OVER FITTING. FROM ONE DUCT OVER OTHER DUCT. E) APPLY DUCT TAPE* AROUND JACKET E) APPLY DUCT TAPE* AROUND OUTSIDE 0 o AND FITTING WITH AN EQUAL TAPE OF JACKET EDGE WITH EQUAL TAPE WIDTH ON EACH. WIDTH ON EACH JACKET. SPLICING CLAMP ONLY A) SLIP DUCT OVER FITTING AT LEAST A) FOLLOW AS DIRECTED UNDER 'CONNECTIONS' THREE INCHES. BUTTING TWO DUCTS METAL CLAMP B) PLACE CLAMP** AROUND DUCT AT TOGETHER ON A STANDARD SHEET (FOR LOW TO BondEi FITTING AND TIGHTEN WITH APPROPRIATE METAL COUPLING AT LEAST SIX INCHES MEDIUM PRESSURE TOOL UNTIL ALL MATERIAL UNDER CLAMP IN LENGTH. NOT TO EXCEED HAS BEEN COMPRESSED AND CLAMPING 4 IN. W.G.) PRESSURE IS ASSURED. SEE PRESURE C) CHECK CONNECTION BY PULLING ON LIMITATIONS FOR DUCT WITH A FORCE OF AT LEAST 25 PLASTIC CLAMPS** MIN. LBS. TO INSURE DUCT HAS BEEN ADEQUATELY CLAMPED. CONNECTING OR SPLICING TAPE & CLAMP (FOR LOW, MEDIUM OR HIGH PRESSURE NOT TO EXCEED 10 IN. W.G.) SEE PRESURE CONNECTING LIMITATIONS FOR PLASTIC CLAMPS** SPLICING A) PULL BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. B) SLIP CORE OVER FITTING AT LEAST 1 1/2 INCHES. C) APPLY DUCT TAPE* AROUND CORE AND FITTING WITH EQUAL TAPE WIDTH ON EACH. D) PLACE CLAMP** AROUND TAPE AND CORE AND TIGHTEN WITH APPROPRIATE TOOL. E) PULL BACK INSULATION AND JACKET AND APPLY DUCT TAPE* AROUND JACKET AND FITTING. WITH TABBED DUCTBOARD FITTINGS, OUTER JACKET MAY BE 'DIAPERED' INSTEAD OF TAPED (SEE STEP F). F) PULL JACKET OVER RING, THROUGH HOLE, AND FOLD UP WITH TABS. A) BUTT TWO CORES TOGETHER ON A SIX INCH METAL COUPLING AND FOLLOW DIRECTIONS UNDER 'CONNECTIONS'. * DUCT TAPE: USE A MINIMUM OF ONE WRAP OF 2 INCH OR TWO WRAPS OF 1 1/2 INCH WIDTH OF TYPE SHUFORD #PC622, TUCK #92T, ARNO #C520, POLYKEN #222, OR NASHUA #357. ** PLASTIC CLAMPS: PLASTIC CLAMPS ARE NOT RECOMMENDED FOR PRESSURES EXCEEDING 4 IN. W.G. (DIAMETERS 3" — 10') AND 2 IN. W.G. (DIAMETERS 12" AND OVER) TO ACHIEVE PROPER TENSIONING OF PLASTIC CLAMP, SET CORRESPONDING TOOL AT MAXIMUM TENSION SETTING. APPROVED TYPES: PANDUIT TYPE PLT—H (TOOL G); CATAMOUNT L-175 (TOOL L-300); OR TYTON T-150 (TOOL T-150). ❑❑❑❑ ❑❑■❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRA'MNCS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL OF JACOBSEN MANUFACTURING DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: DRAWING TITLE: ❑ „❑ P.O. BOX 368 MATERIALS INC. SUCH MATERIALS ARE PROVIDED TO THE MOBILE HOME SET-UP DUCTWORK DRAWING NUMBER: SU-13-001 O ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. PHONE (727) 726-1138 00 i:1-72 ELECTRIC CLOTHES DRYER VENTING IMPORTANT - BEFORE DRYER IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES SET UP TO RECEIVE A DRYER ARE EQUIPPED WITH A VENT HOLE PRE -DRILLED THROUGH THE FLOOR AT THE DRYER LOCATION, TO COMPLETE THE DRYER EXHAUST SYSTEM, FOLLOW THESE PROCEDURES: 1. REMOVE THE DRYER VENT ACCESS HOLE COVER. 2. CUT DRYER VENT DUCT TO THE PROPER LENGTH, AND CHECK FOR OBSTRUCTIONS. THEN CONNECT TO DRYER IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE FLEXIBLE DRYER DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS. NOTE: DO NOT USE ANY SCREWS OR OTHER DEVICES THAT EXTEND INTO THE DUCT. 5. STRAP THE DRYER DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE DRYER EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE INSTRUCTIONS LISTED ABOVE. NOTE: GAS DRYER INSTALLATION MUST BE DONE BY QUALIFIED PERSONNEL. THE CUTTING OF STRUCTURAL ELEMENTS OF THE HOME, SUCH AS RAFTERS OR FLOOR JOISTS TO EXPEDITE INSTALLATION IS PROHIBITED. ANY WEAKENING OF THE STRUCTURE RESULTING FROM SUCH CUTTING IS NOT THE RESPONSIBILITY OF JACOBSEN HOMES, AND MAY RESULT IN NEGATING YOUR WARRANTY. NSTALLED DUCT ;T BE METAL :X OR RIGID CAP CAP NOTES: ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAHINCS ARE DRAWN BY: R.R. DATE: 01-21-00 REV. LETTER: ❑❑■❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL ING RUCHSMATERAOF CLSBARE CTORTHE DRAWING TITLE: ELECT. n ❑„❑ INC. R01A EDSEN CLOTHES DRYER VENTING /(�\ ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 • RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-15-0001 46,. SITE INSTALLED WATER HEATER PAN DRAIN IMPORTANT - SET-UP OF THIS HOME REQUIRES THAT AN ON -SITE DRAIN BE INSTALLED FROM THE WATER HEATER PAN TO THE EXTERIOR OF THE HOME BEFORE THE WATER HEATER MAY BE USED. WATER HEATER PAN\ FACTORY INSTALLED \ DRAIN THROUGH FLOOR ---,, AND BOTTOM BOARD SITE INSTALLED DRAIN y PIPE AND ELBOW (1/4" PER FOOT MIN. SLOPE) I'll - UL U , , .- 4'-0" O.C. MAX. DRAIN TO EXTEND PAST THE EXTERIOR WALL LINE AND BE LEFT EXPOSED AND VISIBLE FOR INSPECTION. T-1 (SEE DETAIL 'A') SCREEN FACTORY INSTALLED BETWEEN PIPE AND ELBOW. THIS ASSEMBLY TO BE USED AS OVERFLOW PIPE TERMINATION. DETAIL 'A' (DEALER IS RESPONSIBLE FOR THE SHIP LOOSE W/H PAN PIPE ON SITE INSTALLATION) NOTES: 1.) SITE INSTALLED STRAPPING USED TO MAINTAIN THE REQUIRED SLOPE MAY BE SECURED TO FLOOR FRAMING AND/OR CHASSIS MEMBERS. 2.) SHIP LOOSE DRAIN LINE TO BE THE SAME MATERIALS AS THE FACTORY INSTALLED W/H PAN PIPE. ALL MATERIALS FOR THE COMPLETION OF THE ON SITE DRAIN WILL BE SHIPPED LOOSE. 3.) THE WATER HEATER PRESSURE AND TEMPERATURE RELIEF LINE MAY TERMINATE UNDER THE HOME. ❑❑❑❑ JAC O B S E N HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: M.T. DAIS 03-08-07 REV. LETTER: ❑❑■❑ORGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE W/H PAN DRAIN Q P.O. BOX 368 TO THE u ❑„❑ INC. SUCH MATERIALS ARE PROVIDED ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MIST BE KEPT CONFIDENTIAL AND SEDU FROM OTHERS. DRAWING NUMBER: SU-15-0003 47' DOWN DRAFT RANGE VENTING IMPORTANT - BEFORE RANGE IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES WITH A DOWN DRAFT RANGE ARE EQUIPED WITH EXHAUST DUCT INSTALLED FROM THE RANGE THROUGH THE FLOOR, THE REMAINING DUCT IS SENT WITH THE HOME AND MUST BE INSTALLED ON SITE. 1. LOCATE DUCT DROP FROM RANGE. (MAY BE EXTENDING THROUGH BOTTOM BOARD, OR SEALED INSIDE) 2. CHECK DUCT PROVIDED FOR PROPER LENGTH, AND OBSTRUCTIONS. THEN CONNECT TO DUCT DROP FROM RANGE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE DOWN DRAFT RANGE DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS OR SCREWS. NOTE: DO NOT USE ANY FASTENERS THAT CRUSH OR BLOCK THE DUCT. 5. STRAP THE DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM BENDING OR COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE RANGE EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, AND THE INSTRUCTIONS LISTED ABOVE. RANGE NOTE: DROP LOCATED DIRECTLY BELOW RANGE BLOWER MOTOR SITE INSTALLED DUCT f VENT CAP ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAB1NGS ARE DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: ❑.❑ ORIGINAL. PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS AT JACORIALS E MANUFACTURING INC. SUCH ARE PROVIDED TO THE THE DOWN DRAFT RANGE VENTING _ ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-113B R SPECIFIC RECIPIENT FOR SPEC6IC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER:N. ' SIJ-.15-0002 48 BOTTOM BOARD P-TRAP ACCESS PANELS - TAPE APPLIED OVER ALL SEAMS AT PATCH APPROX. 1" - PATCH TO BE SAME MATERIAL AS BOTTOM BOARD BEING REPAIRED. HOLE MAY BE (3) SIDED CUT IN BOTTOM BOARD AND TAPE USED TO SEAL EXISTING MATERIAL BACK OVER OPENING VISUALY INSPECT BOTTOM BOARD OF THE ENTIRE HOUSE TO ASSURE THAT THERE IS NO DAMAGE (RIPS OR TEARS ) AND THE AREA AROUND PROTRUSIONS ARE REPAIRED. P-TRAPS MUST BE CHECKED TO BE SURE THEY ARE WELL INSULATED AND COVERED. NOTES: 1. P-TRAP ACCESS PANELS WILL BE BELOW P-TRAP AREA IN FLOOR. 2. P-TRAP ACCESS PANELS MAY BE 3 OR 4 SIDED, AND WILL HAVE 1 OR 2 ROWS OF TAPE AT THE PERIMETER OF THE PANEL. 3. NORMAL BOTTOM BOARD REPAIRS WILL HAVE ONLY TAPE OVER THE CUT OR DAMAGED AREA. 4. MINOR HOLES AROUND PIPES ETC. MAY BE SEALED WITH TAPE 5. THESE ARE SOME ACCEPTABLE TAPES TO USE FOR.REPAIR; SHURTAPE PC658, FIRST LINE 620 ❑❑❑❑ JAC 0 B S E N HOMES NOTICE: THESE SPECIFICATIONS AND mtA1MNGS ARE DRAWN BY: D.M.T. DATE 10-31-01 REV. LETTER: ❑❑E❑ ORIGINAL. PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE D ❑��❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE BOTTOM BOARD P-TRAP ACCESS u ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CWDFNnAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-15-001 O 10-08-08 49 AIR HANDLER CROSS -OVER CONNECTIONS PLENUM (DUCT CONNECTION BETWEEN CROSS —OVER SUPPLY DISTRIBUTION BOX) I / DUCTS SHAM. BE MADE PER OTHER DETAILS. t,oe 00 I CEILING BOARD PLENUM (DUCT DISTRIBUTION BOX) UNIT MARRIAGE LINE DUCT RISER(S) (SUPPLY DUCTS) AIR HANDLER A/C SYSTEM (AIR HANDLER, ETC...) SUPPLIED BY OTHERS AIR HANDLER CROSS —OVER ELEVATION VIEW JACOBSEN HOMES NOSAND DRAWN BY: DATE TNESE sPeanunoxs {w0 DRAVAxcs ARE C.L.Y. 3-21-95 ❑❑■ ORIGINAL, PROPRIETARY, AND CONFlDENTIAL DRAWING 11t�.�., P.O. BOX 368 MATERIALS OF JACOBSEN MAWFACTURINC E HANDLER CROSS —OVER O„ SAFETY HARBOR, FLORIDA 34695 KcmTT FCH OR MAIMS ARE up TOTHE BE ORAWING NUMBER PHONE (813) 726-1138 KEPT COIiIG U& ADO SEOU nN OTHM SU—AC-0100 50. NO 0 imowom 0 . Im