Loading...
HomeMy WebLinkAboutgulfeagleCREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Ceftmcate of No. 29824 17520 Edinburgh Drive Tampa, FL 33847 (813) 480-3421 FLORIDA 911ILDINO CODE T" EDITION (2020) Manufacturer: CONTINENTAL MATERIALS, INC. Issued October 16, 2020 1614 Old York Road Abington, PA 19001 (800) 247-6637 Quality Assurance: Intertek Testing Services (QUA1586) SCOPE Category: Roofing Subcategory: Underfayments Code Edition: Florida Building Code, 7" Edition (2020) Including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Entity $gR91L 1�. Standard `%C Intertek Testing Services (TST1585) 102074565COQ-004 AC 188' 2012 Intertek Testing Services (TST1565) 102074565COO-004A AC 188' 2012 Intertek Testing Services (TST1585) 102074565000-007 ASTM D 228 2009 Intertek Testing Services (TST1585) 10379696000O.003D AC 188' 2012 Intertek Testing Services (TST1585) 10379696000O-004B ASTM D 1970 2015a Intertek Testing Services (CER1497) CCRR-1045 18C, IRC 2012 PRI Constriction Materials Technologies (TST5878) CMI-048.02-01A ASTM D 228 2009 PRI Construction Materials Technologies (TST5878) CMI.048-02-01B ASTM D 226 2009 PRI Constriction Malenals Technologies (TST5878) CMI-048-02-01C ASTM D 226 2009 PRI Constriction Materials Technologies (TST5878) CMI-05S02-01 ASTM D 4533 2015 PRI Constnuction Matenals Technologies (TST5878) CMI-056-02-01 ASTM D 4533 2015 PRI Construction Materials Technologies (TST5878) CMi-062-02-01 TAS 117(B) 1995 'Determined to be equivalent to ASTM D 226 (2009). Type I and 11 CM115001.5 FL18374-R5 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product Changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Impfy warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. [A CREEK CONTINENTAL MATERIALS, INC. SocureGrlp Undorlaymonts TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION SecureGrip PROM A mechanically attached, woven polypropylene underlayment (nominal weight = 1.74 Ib/100ft?) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum tensile strength per ASTM D 5035 of 20 poundslinch, and meets liquid water transmission test of Section 8.6 of ASTM D 4869. The underlayment is available in rolls 48-Inch wide by 250-ft long. SecureGrIp25TM A mechanically attached, woven polypropylene underlayment (nominal weight = 2.05 Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum tensile strength per ASTM D transmission test of Section 8.6 of 5035 of 20 pounds/inch, and meets liquid water ASTM D 4869. The underlayment is available in rolls 48-inch wide by 250-ft long. SecureGripT" PLUS A mechanically attached, woven polypropylene underlayment (nominal weight = 2.46 Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum tensile strength per ASTM D liquid water transmission test of Section 8.6 of 5035 of 20 pounds/inch, and meets ASTM D 4869. The underlayment is available in rolls 48-inch wide by 250-ft long. SecureGrlpMAX- A mechanically attached, woven polypropylene underlayment (nominal weight = 3.69 Ib/100ft2) used an alternative to ASTM D 226, Type I and Type II with a minimum tear strength per ASTM D 4533 of 15 pounds, a minimum tensile strength per ASTM D 5035 of 20 poundsllnch, and meets liquid water transmission test of Section 8.6 of ASTM D 4869.. The underlayment is available in rolls 48-inch wide by 250-ft long. SecureGrip'" PS MAX HT A self -adhered, polymer -modified bitumen underlayment with a synthetic facer (nominal weight = 18.5 Ib/100ff) used as an alternative to ASTM D 226, Type I and Type II and ASTM D 1970 with a minimum tear strength per ASTM D 1970 of 20 pounds. The underlayment is available in rolls of 36-inch wide by 72 ft long. APPLICATION INSTRUCTIONS FOR SECUREGRIP PROT", SECUREGRIP25Tm, AND SECUREGRip- PLUS Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. New construction in the HVHZ shall be minimum 19/32-inch plywood. Roof decks shall have no more than 1/8-inch gap at abutting joints. Attachment method Underlayment shall be attached in accordance with the FBC Section 1507.1.1, Table (non-HVHZ): 1507.1.1.1 and manufacturer's installation instructions. Use of 1-inch diameter plastic cap nails where the ultimate design wind speed, V.4 equals or exceeds 170mph is permissible with the following provisions: 1) The attachment density shall be increased by a factor of 3 for SecureGrip PROTM, SecureGripWm, and SecureGrip TMPLUS 2) The attachment density shall be increased by a factor of 2 for SecureGripMAXTM Attachment method Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch (HVHZ): end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Table 1507.1.1.1. (Non-HVHZ): Allowable roof coverings Underlayment shall be used with mechanically attached asphalt shingles, metal roof (HVHZ): panels and shingles, composite shingles and wood shingles and shakes CM115001.5 FL16374-R5 Page 2 of 4 This evaluation report Is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not Specifically addressed herein. -` CREEK CONTINENTAL MATERIALS, INC. 3ocureGrlp Undo►laymortta TECHNICAL SERVICES, LLC APPLICA71ON INSTRUCTIONS FOR SECUREGRIP"i PS MAX FIT Application: All underfayments shell be Installed In accordance with the FBC. Deck substrates shell be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Pdor to beginning installation, the undertayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underfayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3' side laps and minimum Wend laps staggered min. 6-ftfrom preceding course. In the HVHZ, the underlayment shall be installed over one of more plies of ASTM D 226 Type II or ASTM D 2626 organic felt with minimum 4' head laps and minimum 6' end laps In accordance with FBC Section 1518.3. It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application 40'F: Contact the manufacturer when instaffing at temperatures below Me minimum Temperature: application temperature. Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1607.1.1. (Non-HVHZ): Allowable roof coverings Underiayment shall be used with mechanically attached asphalt shingles, metal roof (HVHZ): panels and shingles, composite shingles and wool shingles and shakes LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) All undedayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment Roof coverings shall be mechanically fastened through the underfayment to the roof deck. 9) The underlayment shall not be installed over existing roof coverings. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. CMI15001.5 FL18374-R5 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 81G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK CONTINENTAL MATERIALS, INC. SocureOrip Underlaymanb TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. S`��,,,RY No 74021 -O ; Cr . /STATE OF :lu; CERTIFICATION OF INDEPENDENCE 2020.10.16 i�-13:44:09 yy+.b MlR�rl -041001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, norwill It acquire, a financial interest in any company manufacwng or distributing products under this evaluation. CREEK Technical Services. LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor wilt acquire, a financial Interest In any company manufacturing or distributing products under this evaluation. Zachary R. Priest P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product END OF REPORT CM115001.5 FL16374-R5 Page 2 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein.