HomeMy WebLinkAboutFinal SurveyC]
2
zw
m
i
L0
rn
1
GRAPHIC SCALE
20 40 SO
( IN FEET )
1 inch = 40 ft.
160
SAINT LUCIE COUNTY, FLORIDA
I IIyM AD
NO SCALE
LEGAL DESCRIPTIOM
:FROM THE .SOUTHWEST CORNER. OF THE NORTHWEST 1/4 OF THE SOUTHWEST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 20, TOWNSHIP 35 SOUTH,.
RANGE 40 EAST, RUN NORTH 312.17 FEET, THENCE RUN EAST 330.36 FEET TO A POINT THAT IS 314.89 FEET NORTH OF THE SOUTH LINE OF
SAID NORTHWEST 1/4, SAID POINT BEING THE POINT OF BEGINNING, THENCE CONTINUE EAST 330.36 FEET TO THE EAST LINE OF SAID NW 1/4,
THENCE RUN NORTH 317.42 FEET TO THE SOUTH LINE OF KIRBY LOOP ROAD, THENCE RUN WEST ALONG THE SOUTH LINE OF KIRBY LOOP ROAD
330.26 FEET, THENCE RUN SOUTH 320.84 FEET TO THE POINT OF BEGINNING, ALL LYING AND BEING IN SECTION 20, TOWNSHIP 35 SOUTH, RANGE
40 EAST,SAINT LUCIE COUNTY, FLORIDA.
CONTAINING 2.425 ACRES, MORE OR LESS.
SURVEYORS NOTES AND REPORT:
1. THIS SPECIFIC PURPOSE SURVEY WAS PERFORMED FOR THE PURPOSE OF MAPPING THE SHED, AS SHOWN AND DEPICTED HEREON, I HEREBY
CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS IS A TRUE AND ACCURATE DEPICTION OF A FIELD SURVEY PERFORMED
UNDER MY DIRECTION AND COMPLETED ON FEBRUARY 8, 2022. 1 FURTHER CERTIFY THAT SAID DRAWING IS IN COMPLIANCE WITH THE
STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS, IN CHAPTER 5J-17, FLORIDA
ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027. FLORIDA STATUTES.
2. THIS SURVEY MAP AND REPRODUCTIONS THEREOF ARE NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND RAISED SEAL OF A FLORIDA
LICENSED SURVEYOR AND MAPPER. THIS SURVEY CANNOT BE TRANSFERRED OR ASSIGNED WITHOUT THE SPECIFIC WRITTEN PERMISSION OF
ENGINEERING, DESIGN AND CONSTRUCTION, INC. IT IS A VIOLATION OF CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE, TO ALTER THIS SURVEY
WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT OF THE SURVEYOR. ADDITIONS AND/OR DELETIONS MADE TO THE FACE OF THIS SURVEY WILL
MAKE THIS SURVEY INVALID
3. THE LAST DATE OF FIELD WORK (AND DATA ACQUISITION) WAS NOVEMBER 8, 2022.
4; CURRENT DESCRIPTION($) SHOWN HEREON PROVIDED BY; THE OFFICE OF EDC. A TITLE SEARCH FOR THIS PROPERTY HAS NOT BEEN
ABSTRACTED TO SHOW MATTERS OF RECORD SUCH AS EASEMENTS OR OTHER ENCUMBRANCES OR RESTRICTIONS.
5. PARCELS CONTAIN A TOTAL OF 2.425 ACRES, MORE OR LESS.
6. THIS SPECIFIC PURPOSE SURVEY HAS BEEN REFERENCED TO THE FLORIDA STATE PLANE COORDINATE SYSTEM EAST ZONE, NAD 83 (1990).
7. SUBSURFACE IMPROVEMENTS INCLUDING UNDERGROUND UTILITIES, UTILITY SERVICES, WERE NOT LOCATED AS PART OF THIS SURVEY..
B. REVISIONS SHOWN HEREON DO NOT REPRESENT A "FIELD SURVEY UPDATE` UNLESS OTHERWISE NOTED,
9, BEARINGS SHOWN HERON ARE BASED UPON THE EAST LINE OF THE NORTHWEST 1/4 OF THE SOUTHWEST 1/4 OF THE SOUTHWEST 1/4 OF
SECTION 20, TOWNSHIP 35 SOUTH, RANGE 40 EAST, SAINT. LUCIE COUNTY, FLORIDA PER THE LINE LABELED HERON AS (BEARING BASIS) AND
ALL OTHER BEARINGS ARE RELATIVE THERETO. DISTANCES ARE IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF.
10. ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) AND ARE BASED ON THE FLORIDA
PERMANENT REFERENCE NETWORKS (FPRN) USING GPS REAL TIME KINEMATIC (RTK) OBSERVATION WITH AND ACCURACY OF t0.06`-0.10% SITE
BENCHMARKS UTILIZED ARE SHOWN HEREON.
11, THIS SITE WAS SURVEYED UTILIZING 'TRIMBLE/SPRECTRA HARDWARE- TOGETHER WITH SPECTRA SURVEY PRO REALTIME PROCESSING AND WAS
BASED ON TRIMBLES "VRS NOW" NETWORK AND/OR THE FLORIDA PERMANENT REFERENCE NETWORK (FPRN). THE PROCEDURES AND NETWORK
DESIGN MEETS THE GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING CPS RELATED POSITIONING AS SET FORTH BY THE
FEDERAL GEODETIC CONTROL COMMITTEE IN THE MOST CURRENT PUBLICATION FOR 3RD ORDER CLASS ONE FOR HORIZONTAL CONTROL
SURVEYS:.
12.IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMBOLS SHOWN HAVE, BEEN EXAGGERATED TO MORE CLEARLY ILLUSTRATE THE
RELATIONSHIP BETWEEN PHYSICAL IMPROVEMENTS AND/OR LOT LINES. THE DIMENSIONS SHOWN SHALL CONTROL THE LOCATION, OF THE
IMPROVEMENTS, OVER THE SCALED POSITIONS.
13. THE OWNERSHIP OF PERIMETER FENCES, WALLS, HEDGES AND LANDSCAPING, IF ANY, SHOWN HEREON ARE NOT KNOWN AND ARE NOT LISTED
AS ENCROACHMENTS, THEIR RELATIVE LOCATION IS SHOWN IN RELATION TO THE BOUNDARY LINES SHOWN,
14. THE SURVEY MAP SHOWN HEREON DOES NOT NECESSARILY CONTAIN ALL OF THE INFORMATION OBTAINED OR DEVELOPED BY THE UNDERSIGNED
SURVEYOR IN HIS FIELD WORK, OFFICE WORK OR. RESEARCH.
15. THE PROPERTY WHICH IS THE SUBJECT OF THIS SURVEY APPEARS' TO BE SITUATE IN AN AREA OF MINIMAL FLOOD HAZARD AT THIS TIME
PURSUANT TO FaEM.A, FIRM NUMBER 12111CO186J, HAVING AN EFFECTIVE DATE OF FEBRUARY 16, 2012. FOR APPROXIMATE DELINEATION OF
THE FLOOD ZONE LIMITS, REFER TO AFOREMENTIONED FIRM PANELS.
SYMBOL & ABBREVIATION LEGEND-
= GUY WIRE, ANCHOR.
-OHW- = OVERHEAD WIRE
rC) = WOOD POWER POLE
CMP = CORRUGATED METAL PIPE ("�'�
FND = CONCRETE Si co
FNQ =FOUND DQi Inli
L6 = LICENSED BUSINESS prove
N' = NORTH OR NORTHING
E = EAST OR EASTING'
S = SOUTH
SW = :SOUTHWEST
W ='WEST
R/W = RIGHT-OF-WAY
F.F.E. = FINISH FLOOR ELEVATION,
7,
{ � FfiY
1r
FLORIDA REGISTRATION #5556
r ,
F.B.P.E. CERTIFICATE OF AUTHORIZATION 9935
LB. CERTIFICATE OF AUTHORIZATION 5095
y m w w
m W,
q Q w UUI L �O
U �- vppi
� N
R
� � g
00
p
U.
°"'®
®0z
0
®
C 9
LS!
U
M
[L
J
CN
U)
Z
LU
RECEIVED
-7 MAR 0 4 2022
id CJ 1 St. Lucie permitfinu
Cont