Loading...
HomeMy WebLinkAboutBOUNDARY SURVEY MIN.SETBACK REQUIREMENTSI LEGAL DESCRIPTION Unit K, HARBOUR RIDGE, PLAT NO. 21, according to the Plat thereof, as recorded in Plat Book 32, Pages 22 and 22A, Public Records of St. Lucie County, Florida. R=120.00 Delta=12'17 I PREPARED FOR: John and Margaret Louletta Prepared By: Regina C. Kamer, PSM#4363 Kamer Surveying, Inc. LB#7357 '-a' r 15.0 F+n'sned goo S44®41'081,iy 213.46'(P) S44'41'13"W 213.57'(M) Tract G-11A (osprey Villogge ll12 Harbour RId9 PA'Condo m num Vari1 westinGarageFlElevationations w oor beng Ii Prepared ]!or: John r Margaret . ,i MIN. SETBACK EQ FRONT 125 SIDES YnF'r "— -f CNR SIDES a5 rfi. REARZNG. TECH. vim+ o uA 7J� b W SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal. 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 3.26.2019. 4 This Survey was prepared using the Plat of Record, no search of the public records was performed by this office. 5 This Survey shown hereon was prepared in accordance with the Standards of the practice of Surveying and Mapping as defined in 5J— 1 7.050-052FAC. 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Bearings have been based on the North Line of the Subject Property as shown hereon. All other bearings are relative thereto. 8 Parcel/Lot fine locations have been based on found survey control along the center line and/or right of way line of NW Mariner Court. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined as part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point 'of reverse curvatures (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 Elevations shown hereon are in accordance with the North American Vertical Datum of 1988. i FEMA Flood Zone data shown here on is based on the visual inspection of e the digital Flood Hazardous Maps provided by the Federal Emergency Management Agency (FEMA) and is limited to the accuracy of such maps. Flood Zone: X Community 1: 120285, Panel 1: 0402, Suffix: 'K, Date: 2,19.2020 .RNER SURVEYING, INC. Ne§dential & Commercial Surveying Services 2740 SIB` Harfin Downs Blvd.#333, Paim City, 17.34 Phone: J,772)288r7206&rn Pax_(772)223 8 C — Concrete CIE — Cowered Entry = — Concrete Pad with Ar Consisiudng CB — Catch Basin CBS — Concrete Mack structure CMP — Corrugated Motet Pi CPE — Concrete Pad with Pact Equipment ON — Cable TV Box FFE — Rnished Roor Elavatkm GV — Water Gate valve HYD — Fire Hydrant 0 - Overhead thig y Une PP - Power Pole SSMH - Sanitary Sewer Manhole TCD - telephone Communicaflona Box us - utility Box WM - Wafer Meter LEOLD0 FCN a Found nP w Found FPO Found FIR — Found ; FIRC - Found sm set # WC - Found FM - Found FMD =- Found FN -- Found f FP FNFF Found FPKD -Found MRS - reum /cc - in Pal Site Plan Legend: XO.00 — Denotes existing Elevations (NAVD) NAVD — North American Vertical Datum Site Plan per _.� .26,1:FFE and addl dimensions 9 s+ e4 Concrete Monument ron Pipe tron Ze with cap hon i kan Rod with Cap ron Rai with Corp RB17357' 12` Aron P" with Cup Na g Nall with Disk ,it with rm Tab Plans dated 3,21.2021 Boundary STjrvay sat Akr 12a21 Fla 2xk, I ' i ofi Ct T+Tb fkm :kc Ffw sc rxwr-x