HomeMy WebLinkAboutPOOL - SPA LAYOUT & PIPING PLAN0 48" MIN. HIGH FENCE W/ SELF LATCHING GATE THAT SWINGS OUT AWAY FROM POOL AREA VERIFY EXIST, FENCE IN COMPLIANCE W/ CHILD SAFETY BARRIER REQUIREMENTS PER FBC SEVENTH EDITION (2020) - EXISTING OR SEE SEPARATE PERMIT IF NEW - (BY OTHERS) NOTEG GROUND WATER MUST BE BOTTOMLOWERED TO k kDEEPt END PRIOR TO OL TO AVOID UPLIFTING (POPPING) ': k k PROVIDE 24" WIDE - FILTER CLOTH (CENTERED) ALONG VERTICAL JOINT@ POOL AND RETAINING WALL - TYP. BOTH SIDES (BY OTHERS) RETAINING WALL -BY OTHERS NOTE FINAL YARD GRADES TO BE FLUSH WITH EDGE OF POOL DECK (OR POOL WHERE NO DECK IS PROVIDED) AND TO SLOPE AWAY FROM POOLtDECK AT 1':12' MAX. FOR FIRST 6' FROM EDGE, RETAINING WALL & STAIRS W/ RAILING - BY OTHERS ` - m %1ZOTEW x .�" (Y 0381-1011 i'I;R1FY; 23'-8" F---T--- I 4' -o"- T., F i _-- 2`_4" 23'-4" _3'_' SCH 40 PERIMETER BONDING _30" T.O.C. WIRE @ 1 (SE - 24" MAX. FROM W.L.L. {SEE DE'I'A1L) --'�- ---• '— 2.5" VANISHING EDGE PIT 8 s 2` \ \ 8'° T1Ht;.K COMMON AUTO -FILL DEVICE WALL SEE \ 3/4" FRESH WATER SECTION SHEET 2 \ SUPPLY LINE FROM EX. \ \ -0"- T.O.0 SOILS UNDER POOL STRUCTURE: 5'BEYOND TO BE PREPARED ENGINEERINGACCORDANCE WITH ALLTERRA REPORT DATED 10-6-2021 a" RETAINING WALL & STAIRS W/ RAILING - BY OTHERS p,ECEIVED ,IAN 0 6 7017 Permitting Department St. Lurie coun`v HOSE BIBB - BY OTHERS FIELD VERIFY H.B. LOC. & 2" OVERFLOW LINE TO i ON -SITE DRAINAGE -'- SYSTEM 2"SCH 40 STEPS - (4) POOL (4) POOL 240 SQ. IN. MIN. FILTERED TOP TREAD EDGE FEATURE INLETS FLOOR INLETS v 8" THICK FLOOR W/ 1.5" SCH 40-- I x #4111A. REBAR @ 12" m O.C. LATERAL a 3" SCH 40 (2)AQUAS'I'AR 32CDFL-321° I � CHANNEL DRAIN (316 GPM @ 3s & 6" O.C. LONG. � I 6 FT/SEC THRU GRATE SINGLE UNBLOCKABLE COMPLIANT W/ 25' ASM,E/ANSI A 112.19.8 - 2017 N 4 LED LIGHTS - I '^ 3 SCH 40 I OR EQUAL P, O I IN wl STUB -OUT FOR 2.5" AI 18"BENCH- POOL CLEANER SCH ® 20" BELOW 40 COI W.L. CENTERLLNEOFSPA - FIELD VERIFY 2" SCH 40 19'-5" e' I 7'-11" 18" 8" 3'-611 3'-6't �(�Cv V A SKIMMER I 6'-8" \ \ I — 8" ® NICHELESS I I MOTH � I POOL HEATER/5 TO BE A MIN. OF 48" a V-6PO 1.9-67f ��—_— -----� \�— S3 2.5"Sc 40 —ti 1.5" SCH 40 � \ _ "®' I _24 2.5' IN 12" ISED SPA �� I 7 r }- ' I 18" BENCH-20" BELOW W.L. & 24" BELOW W.L. I m �i N I� (6) THERAPY JETS I -20" (2) FILTERED IN LET5 'I, I (2) AQUASTAR 32CDFL - 32" CHANNEL DRAIN I ' (316 GPM: @ 3.9 FTISEC THRU GRATE - SINGLE (— — — _ _ UNBLOCKABLE OR EQUAL) — — — — �� SPA SIDE AIR SWITCH (1) LED SPA LIGHT -NICHELESS 899 f 3" SC1i 40 �5" SCH 40 (1) T WIDE, SPILLWAY ( I— — TILE BACKSIDE OF SPA DOWN TO DECK l 10111W4010111 lllkf.Xoj ILI)r t IN t, r r t t r t VERIFIED W/ OWNER PRIOR CONSTRUCTION ONTROL LINES - FIELD VERIFY LOCATIONS POOL/SPA LAYOUT & PIPING PLAN SCALE: I/4"=I'-0" 1 6,-6vr I I HORIZONTAL FROM ANY DOOR, OPERABLE WINDOW OR GRAVITY MR INTAKE INTO BUILDING OR PER _ SUN SHELF I I MANUFACTURE'S SPECIFICATIONS, 6 DEPTH I I WHICHEVER GREATER T I J 4a j I POOL/SPA. EQUIP. T 2'-4" I SEE SITE PLAN: I I BY OTHERS REINFORCED OR 2'-4" / PRODUCT APPROVED CONCRETE SLAB(S) (F1ELVERIFY SIZE & _ _ - LOCATION) t SCH 40 2.5" SCH 40 :i" SCH —40 GII 40 '� 18"BUNCH - —�/ j �aI5T... &�.�...`. 20" BELOW W.L. DECK -BY OTHERS NOTE: .. �. �I b f� 1 .t �� � i 1 f t •� NOTE THESE PLANS ARE FOR POOL AND SPA STRUCTURES, PLUMBING, EQUIPMENT/ELECTRICAL & DECK ONLY, ALI, OTHER FEATURES DESIGNED BY OTHERS. ���G �p GoJO o ^04 a v3G`� GG in - 6® DECK - BY IS" MIN:MAX. 24" MA 12°'COPING- OTHERS INSTAL LED ONLY SLOPI; DECK:CK (ENTIRE, PERIMETER) 2„ N a� n,. PER. FOOT �, a 3"wa.. W.L.. v, 6- #8 SOLID BARE COPPER - ,.. w BOND WIRE W/APPR - - Yr CLAMPS (ONE ON EACH _ -.� J® SIDE OF POOL-4 TOTAL) r 10" WIDE X 6" DEEP f I BEVAM V t O 2 #4 DIA. G Z a � REBAR CONT. #8 SOLID BARE COPPER WIRE 0„ BONDED TO cool. STEEL As SHOWN MARCITE ^''� NOTE: BONDING WIRE REQUIRED AT PERIMETER OF POOL OR EQUAI. E EL REINFORCING STEEL #4 DIA. REBAR (k 12" O.C. EQUIPOTENT[AL BONDING DETAIL V ERT & 6" O.C.HORZ. IN PER FLORIDA BUILDING CODE ADAPTATION OF 81, -�-�' LONG WALLS & #4 DIA. N.E.C. 2017 SEC. 680.26 REBAR rt 12" O.CX.W. / RADIUS ELSEWHERE - #4 DIA. REBAR 12" O.C. LATERAL. VARIES & 6" O.C. LONG. (FLOORONLY) TYPICAL WALL SECTION SLOPE TOP 2 APPLY BASECRETE WATER PROOFING ON VANISHING 891 24" 8'P EDGE WALL -PER MANUFACTURES SPECIFICATIONS EXTEND Y ONTO POOL FLOOR AND ADJOINING V-6" WALLS I 1 BELOW SUB -GRADE 44 DIA. REBAR a, 6" O.C.E.W. IN COMMON WALL ONLY -(TURN ALL STEEL MIN. 24" INTO WALLS & FLOOR) um a PIPE REDUCED TO V f AND RUN TO DECK i 3 / BOX 2" SC H 40 PVC CORD LED LIGHT SLEEVE SP 10-22 WALL FITTING - OR EQUAL INSTALLED INSIDE PIPE NICHELESS LIGHT DETAIL 12" 12" 12" SKIMMER COVER W/ ADJUSTABLE COLLAR ni4" AECK-BY 01 HE lis LEnF'BASKET WRAP (2) #4 DIA. AROUND POOL WALL. SKIMMER, TIED TO POOL -.-m.-- STEEL ON EACH SIDE OF SKIMMER 1 t17 POOL PUMP 25 GPM MIN. FLOW POOL S'OTL SKIMMER DETAIL ) , rnw NEUT. IEAT PUMP / 2 #6 CU, 1 #10. 2.7 HP EDGE EE:ATL'RF, PUMP MOTOR w/ & (1) #10 CU GROUND IN 3/4" CONDUIT BUILT-IN OVERLOAD SWITCH W/ 3 - # N C NNECT TO AMP-2P LE BREAKER O 0 O PIIH>I CU WITHIN 1/2" MIN. 1}IIII' ( D Cow DI AT TO 20 AMP - 2 POLE GFCI HEATER (GAS) - IGNITION SWITCH 2.7 3 - 412 THHN CU WITHIN 112" CONDUIT 2.7 HP SPA THERAPY PUMP MOTOR wl {CONNECT TO 20 AMP -1 POLE BREAKER} BUILT-IN OVERLOAD SWITCH W/ 3 - #10 TURN CU WITHIN 1/2" MIN. CONDUIT (CONNECT TO 20 AMP - 2 POLK GFCI CONTROLIPOOL PANEL, W/ 100 AMP BREAKER) - 2 POLE BREAKER W/INTEGRAL TIME CLOCK FOR PUMPS, MOTOR MANUAL MOTOR STARTER SWITCH AND HEATER MHEREC. PUMP MOTOR w/BUILT-IN (2) - #3 LINE, (1) #4 NEU. & (1) #S OVERLOAD SWITCH W/ 3 - #10 TURN EQUIPMENTGROUN'DING CU WITHIN 112" MIN, CONDUIT CONDUCTOR THHN CU IN -- (CONNECT TO 20 AMP - 2 POLE GFCI 1 1/4" RPVC CONDUIT S.P3.T. TOGGLE BREAKER) SWITCH (4) LED POOL LIGHTS--" 12 VOLT TRANSFORMER (GFI NOT REQUIRED) JUNCTION BOX (1) LED SPA LIGHT ( GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH NEC 2017, SECTION 680. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 THHN CU WITHIN 112" MIN. CONDUIT FOR POOL LIGDT(S). 3. GROUND At,[, BOXES, LIGHTS, MOTORS, ETC. w/ #B SOLID, BARE COPPER. 4, PROVIDE W.P.G.F.I. OUTLET 10' MIN. - 20' MAX. FROM W ATER'S EDGE. 5. ALL POOL. PUMPS TO BE GFCI PROTECTED PER NEC 680.5. 6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL, - BY OTHERS. 7. ALL PVC CONDUITS EXPOSED TO SUNLIGHT TO RE: PAINTED WITH APPROVED COATING. EIJECT I .AL _ DIAGRAM N.T.S. 6" 12 W.L. - vP j W.L. IN PIT - PUMP OFF W.L. IN PIT - PUNIP ON 7.S" 241P (ESTIMATED 3P0 DRAW DOWN - 7• vP i CLEAN SOIL EXTEND W.L. TILE TO BELOW 7.5vP '�I-e+v �- COMPACTED TO #4 DIA, REBAR av .., i 95% MAX. DRY 32" �2" 11 _- DRAW DOWN 7.5 _ AQUASTAR32CDLz -3z" (i I.2 ®.C',E.W. '- ) DENSITY CHANNEL DRAIN (316 GPM "• HYDROSTATIC RELIEF VALVE 8" THICK FLOOR W/ Pv G 3.9 E T/SEC'THRU GRACE - PORT' OR CAP OFF 9 ® SINGLE UNBLOCKABLE 3 i!a° WELL OR EQUAL COMPACTED #4 DIA. BAR � 12 7 �" 3P O.C. LATERAL FINISH PLASTER FLOOR SOIL 6" O.C. LONG. _ MAIN DRAIN SUCTION LINE HYDROSTATIC RELIEF VALVE: & TIED TOGETHER AS SHOWN S PERFORATED PvC COLLECTION ABOVE. - PIPE SIZE PER TUBE., WHERE REQUIRED PLAN VANISHING VN SECTION SCALE: 3/8" = I'-O'v MIN.% YARD GRAVEL SUMP ...... .. NOTE: 25.9 SQUARE, INCH OPEN ARE. A, WRAPPED W/ DRAIN FEILD SCALE: 3/8" = I' -Of' 316 GPM= 3.9 FEETPER SECOND CLOTH (RECOMMENDED) Channel Maul Drain Detail SCALE: N.T.S. Q" 811 7 v CA (E 18" 12" 1 614 i1v4 W.L. 9 12" q de9s 16" #4 DIA. REBAR �^ C, 12" O.C.E.W. CLEAN SOIL �� IN SPA WALLS COMPACTED TO 95% MAX, DRY #4 DIA. REBAR � 12'° `� DENSITY O.C°E.W. , IN SPA FLOOR I _SPA. S I ON SCNLI 3/8" = 1>_ O PUMP FRAME OR FILTER TANK MOUNT OR HEATER A NCHORPOOL PUMP AND ER MFGR'S. N.O A. K REINFORCED CONCRETE SLAB2" MIN.F.G.PUMPFH71ATER FILTER POOL, PUMP, FILTER P'' AND HEATER ANCHOR POINTS MAY VARY POOL EOUIPMENT ANCHORING DETAIL SEE; MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION - EQUIPMENT SHAPES MAY VARY VACUUM FITTING Wl� SELF -CLOSING SAFETY COVER (HAYWARD MODEL #400 OR EQUAL) VACUUM LINE DETAIL E BENCH SECTION 14' EQUIPMENT LAYOUT SCALE: N.T.S. 6'_6P, --�- 3' 8?_ " _ 34 f./fv SLOPE 1' TYPE PO' POOL LEGEND 1. 3" THERAPY JETS SUPPLY LINE 2. 3" SPA MAIN DRAIN LINE 3. 3" EDGE RETURN SUPPLY LINE 4. 3" PIT MAIN DRAIN LINE 5. 3" SPA MAIN DRAIN LINE 6. 2" VACUUM LINE 7. 3" POOL MAIN DRAIN LINE 8. 2" SKIMMER LINE 9. 2.5" SPA RETURN LINE 10. 3" POOL RETURN LINE A. 2.7 HP EDGE FEATURE PUMP B. 2.7 HP THERAPY PUMP C. 1.5" TO WASTE OR DISCIIIARGE TO GROUND D. 2.7 HP REC. PUMP W/ APPROVED HAIR & LINT STRAINER E. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE F. 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS G. 132,000 BTU HEAT PUMP W/ INTERNAL BY-PASS H. CHECK VALVES (TYPICAL) J. VALVES (TYPICAL) K. SALT GENERATOR L. INSTALL PERMA-CAST PB-2008 WATER BOND T:R APPROVED EQUAL TIED TO V'UMP GROUND W/ #8 SOLID COPPER 1 APPROVED f. . fO F SQ. IN SURFACE AREA EXPOSED TO WATER) S" THICK WALLS W/ #4 DIA. REHAR @ 12" O.C. VERT. & 611 O.C. HORS. ,a 8" THICK FLOOR W/ #4 DIA. REBAR a; 12" O.C. LATERAL, & 6" O.C. LONG. 6' n sDEPTH: TO I DEPTH: 4 DEPTH: TOTAL VOLUME: 26,200 SALLONS TURN OVER RATE. 12.1 HR. Eki 3366 GGPPM MAX. - LOW SPEED (TURN OVER RATE: 2.9 HR. ,. DESIGN RATE:GAL./6 % THERAPYELEVATION: DET. ON SITE POOL TILE: S TANDARD POOL i '; PIPING: SCH. !. DECK: BY OTHERS ELECTRIC: BY OTHERS POOL .■ y SPA LIGHT: O; HANDRAIL: NO EDGE FEATURE PUMP: 2.7 HP JANDY E-PUMP - ,. SPA THERAPY PUMP: 2.7 HP JANDY E-PUMP - VSSHP270AUT JANDY 1 • AREA HEATER {- APPV.OVEDIi' COVEI HEATER #2: JANDY JE300T - 132000 BTU HEAT PUMP VACUUM LINk:: YES POOL AREA: 016 S.F. PERIMETER 114 L.F. SPA AREA: 49 S.F. PERIMETER 28 L°F. PIT AREA: 87 &-f-t PERIMETER 93 L.F. AUTO -FILL: YES OVERFLOW: YES CHLORINE GENERATOR: JANDY AQUA PURE 1.400 POOL/SPA CONTROL SYSTEM: JANDY AQUALINK PS4 GENERAL NOTES: 1, ALL LIGHTS LADDERS HANDRAILS, REINFORCIVG STEEL SHALL BE GROUNDED PER CODE. 2. POOL. TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE: STRENGTH OF3000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, MIN. 40 DIA. LAP SPLICE AND PLACED IN ACCORDANCE WITH ACI STANDARDS. PROVIDE 3" MIN. CONCRETE COVER OVER REINFORCING STEEL.. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF. THE SUCTION LINE. 5, STEPS TO HAVE A 10 MINIMUM TREAD AND A 12 MAXIMUM RISER. & POOL TO BE FENCED PER LOCAL. CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. S. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE CURRENT REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI! NSPI 5; ANSI/ NSPI 6; ANSI/APSP 7 AND ANSI/APSP.ICC-15. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER IESIGNED T'O NIINIMl'I,E IIEA'I' LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALI, FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC SEVENTH EDITION (2020) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS IF ANY 11 RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SEVENTH EDITION (2020) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. PRESUMPTIVE LOAD - BEARING VALUE OF SOLI, - IN ACCORDANCE WITH FBC SEVENTH EDITION (2020) SECTION 1506.2 THE SOIL BEARING VALUE SHALL BE A MINIMUM OF 1500 P.S.F. (FOLLOW GEOTECHNICAL ENGINEERING REPORT RECOMMENDATIONS OR INDUSTRY ACCEPTED STANDARDS - BY OTHERS) 13. SHOULD ANY MUCK, MARL, OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT 1 INSPECTION. 14. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 15. POOL PLANS ARE DESIGNED TO MEET THE FBC SEVENTH EDITION (2020) - RESIDENTIAL - PRIVATE SWIMMING POOLS. 16. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2013 AND FBC SEVENTH EDITION (2020) - RESIDENTIAL, CHAPTER 45. 17. GROUND WATER MUST BE LOWERED TO BOTTOM OF DEEP END PRIOR TO EMPTYING POOL, TO AVOID UPLIFTING (POPPING) OF POOL. PLUMBING NOTES; 1. ALL PIPING, EQUIPMENT AND MATF,RI A.LS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC SEVENTH EDITION (2020), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, ,PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING; AT LEAST A DIMENSION OF FIVE, DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER. AI.,I, VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 4. WHERE FRE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL C'H:ECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY' -PASS OR ANTI SIPHON DEVICE INSTAI LF.D TO PROVIDE, A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6, ALL POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO Y-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 8. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACK FLOW PROTECTION. NO OVER -THE -RIM FILL: SPOUT WH,L BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OF NOT LESS THAN 50 PSI FOR 15 MINUTES. IL JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FBC SEVENTH EDITION (2020), PLUMBING REQUIREMENT'S. 12, ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE HEATER. 13. PURPLE PRIMER CONFORMING TO ASTM F656 REQUIRED ON ALL PVC PIPING PER FBC SEVENTH EDITION (2020) PLUMBING 605.21.3. 14. GAS PIPING SHALL COMPLY WITH FBC, SEVENTH EDITION (2020), FUEL GAS. (SEPARATE PLANS ANI) PERMIT REQUIRED) 15. SWIMMING POOL/SPA WATER HEATERS SHALE SEAR THE LABEL, OF A RECOGNIZED TESTING AGENCY. 16. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY - BY OTHERS. POOL SYSTEM FLOW RATE- 15GP (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP = 2.7 HP JANDY E-PUMP - VSSHP270AUT VARIABLE SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED =150 GPM aa> 42 TDI-I 3" SUCTION PIPE {a% 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.594 BRANCH PIPE (a-), 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) 3" PRESSURE PIPE (41 150 GPM'. = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 150 GPM n I GPM/ SQ. FT. =150 SQ. FT. MIN. FILTER AREA mommom DRAWN RV W3C SHEET 2 4; I'