Loading...
HomeMy WebLinkAboutProposed Screen Room PlanDESIGNaCRITERI ;: , APPLICABLE CODES REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN PROPOSED 4" SLAB 3000 PSI CONCRETE W/ FIBERMESH + PERIMETER 8"X8" MONOLITHIC FOOTER (1) #5 REBAR CONT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1 /2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE. SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6' FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6' FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 FOUNDATION PLAN S/04 DETAILS PROPOSED SCREEN ROOM SEE FOUNDATION PLAN SHEET-03 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2x2"4.044" 2 x 3: Zlx3'k0.050" 2 x 4: 2'kKN'4.050" 2 x 5: 2"x5"x0.050" RECEIVED OPEN BACK SECTIONS 1 x2: 1'k20.044" "x3`4.045" FEB 0 8 2091 1 x 3: 1 SNAP SECTIONS St. Lucie County 2 x 2 SNAP: 2"x2"x0.045" Permitting 2 x 3 SNAP: 2'kOlxO.050" 2 x 4 SNAP: 2'k4"x0.045" SELF MATING (SMB) 2 x 4 SMB: n4'k0.044'k0.109' 2 x 5 SMB: Z6c K0.050"x0.109' 2 x 6 SMB: 2'k6'k0.050'k0.120" 2 x 7 SMB: 2"x7`xO.057"x0.120" 2 x 8 SMB: n8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082'k0.124" 2 x 10 SMB: 2"xl0"x0.092"x0.398" DETAIL A aJ�7'Y i C. coo N =CZ:)'� W coo H �:�= y y> z � �� ui i� 1rllll1nln01` Q 2 Q U )o LE COPY IZED IdEVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNT( BOCC t 1X2 � N X-I N X lD cx= N N N 2X4 PB DJ 0 o N N in m DJ 2X4 PB d N N O cI N N N 1X2 - 9'-0" -i ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6' FROM ENDS & 24" CENTER TO CENTER. #10 SCREW 6' FROM ENDS & 12" CENTER TO CENETER. 3. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 4. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 5. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 6. 1 "X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. 7. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. "NOTE: 36" (MAX.) O/H AT FRONT, 25% OF LAST PANEL WIDTH ALONG SIDES, TYP. RESIDENCE HOST CMU WALL 3" X .032" X 1LB I I I I I I I I I I I I I I I I I COMPOSITE PANELS I Lu ujlii O O I� 3003-H 154 (3 0I Lu 1/4"-1' SLOPE (MIN.) wll iix (FL.#7561.1-R5) xi1 IN NII I I I I I I I I I I 2X4X.050 EDGE BEAM X 40'-6" I I I I I I 40'-6" 42'-0" - 6" EDGE EBAM CANTILEVER 2X4X.050 EDGE BEAM X 40'-6" (PANEL LAYOUT MAY BE MIRRORED) m a� a2 a2 a2 0-� V) 0N Nof N� N of N� N w i O O O O O Ql 2X2 2X2 2X2 2X2 2X2 2X2 24" KP 24" KP 24" KP 24" KP 24" KP 24" KP 1X2 II 1X2 1X2 1X2 I 1X2 1X2 6'-8" 6'-8" .6'-8" 6'-8"--tom6'-8" 6'-8" 40'-0" m X cV 1X2 (V X N 2X4 PB DJ X N DJ 2X4 PB N i 9'-0" `\�111111111111//////04 ;Z c co W Q Z zco lllllI \00\''\\ U 0 FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FOUNDATION DESM;N PROPOSED 4" SLAB 3000 PSI CONCRETE W�/"FIBERMESH + PERIMETER 8"X8" MONOLITHIC FOOTER (1) #5 REBAR CONT. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OR NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: L PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT-ASTM C 494 v. CLEAN POTABLE WATER A. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE AREA FOR TERMITES IN COMPLIANCE WITH THE FBC. FOR RISK CATEGORY II, III, & IV STRUCTURES ONLY. g. CONCRETE SLAB SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. (SLAB ONLY) 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #4 X 8" REBAR INTO EX. FOUNDATION EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 6. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. FOOTING NOTES 1. PROVIDE 1-1/2' COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 60 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES ABOVE FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES ABOVE FOR ADDITIONAL CONCRETE INFORMATION & SPECS. O SODDED GRADE 8„ NEW 4" SLAB 3000 PSI W/ FIBERMESH \ 450 (1) #5 BAR CONTINUOUS (25" MIN. LAP) 8"x8" MONOLITHIC FOOTING SCALE: NTS 8"x8" MONOLITHIC FOOTER RESIDENCE o ,•�......... N co o Z;Z c OLj J V (o Q Q = C� z53 ui CONCRETE LEGEND HATCH INDICATES HOST/ EXIST. 0 NEW FOOTING 0 NEW SLAB AREA NOTE: ALL MAY NOT APPLY i 4" SLAB 3000 PSI C?NEW Ln W/ FIBERMESH c-I r- 40'-0" - FILE �®p� REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC at ._ .024 FLASHING SEALEF�5) WALL (TYP.) n^ # 14x1 /2" S.M.S. W/ INTEGRAL 3/4-0 WASHER AND NEOPRENE GASKET Q 12" O.C., TOP & BOTTOM. O O O IF CLEARANCE PROHIBITS INSTALLATION OF TOP O FASTENERS USE #14x4. S.M.S. W/ 1-1/4' 0 FENDER WASHER AND NEOPRENE GASKET @ 12" O.C. s (3) PER PAN FOR PANS EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1 /7' BEARING LEG. HOST STRUCTURE 1 /4" 0 x 2-1 /7' LONG WOOD LAG SCREW OR MASONRY OR WOOD 1/4" 0 x 2-1 /4" LONG MASONRY ANCHORS @ 24" O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. �9 `C EXISTING RAFTER \ Q�. co O O d #14x4"S.M.S.w/1-1/4"0FENDER WASHER pe /� _=z; Jcn OR TRUSS O < # AS ER S.M.S. EO INTEGRAL GASKET AND NEO-PRENE GASKET @ 17' O.C. �' �� ®�� — = u O Q : z = p O WASHER AND NEOPRENE GASKET = (� C4 ` @ 17' O.C., TOP & BOTTOM # 12 X 9/16' W/ 5/8" NEO-WASHER = : O � _ al (3) PER PAN FOR PANS (3) PER PAN FOR PANS ROOF PER P 7 EXTRUDED OR BRAKE -FORMED ROOF HEADER PLAN(�� 0 OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) R SECURE FASCIA TO EACH WITH MIN. 1-1 /7' BEARING LEG. \COVER END OF PANEL `�(�,{/. ��\\ LL RAFTER TAILW/(1)1/4"0x4" `�vHW PAN HEAD LAG CHANNEL (1)1/4"0X7'LAGSCREW@24"O.C. r`u VIEWED ®�////IIIIIIIIItCt`��,\\ BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL 3" X T X .050" MIN. �r�,;y: ROOF PANEL ATTACHMENT -WOOD FRAME (SEE PLAN) P O PLIAN C) �, 00 SCALE: N.T.S. ROOF PANEL TO CARRIER BEAM � G C ���N®vu � R® 00 J o CD CONNECTION SCALE: N.T.S. ®� �? ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNELw/(4) #10x.75' INTO GIRT OR PURLIN & (2) #14x.75" BEAM OR (4) #10xl-1/2' SMS INTO CLIIPPS MAYBE USED UPRIGHT 0.062 ANGLE SCREW BOSSES BEAM -SNAP, NG, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS /8'k7k7k ANGLE SELF -MATING OR 1 SNAP SECTION TYP. 5032 H-32 ANGLE (2) - #12 SMS INTO COLUMN 1",0 O.B. BASE PLATE-TYP. ANGLE - EACH SIDE COL. o 0 ANC 0 0 MIN. CONIC. 1 /4" MASONRY ANCHOR EACH � ANCHOR EMBEDMENT 2-1/4" MIN. CONC. ANCHOR EMBEDMENT SECONDARY ANGLE a , a n ° 3000 PSI CONC. SLAB/FTG. 6x6-10x10 WWM OR FIBERMESH 1 /4" MASONRY ANCHOR AT EACH ANGLE 2-1/4" MIN. CONC. ANCHOR EMBEDMENT SECONDARY ANGLE SIDE VIEW 7' MIN. INCREASE DISTANCE WHEN GREATER THAN 2X4 UPRIGHT IS USED (2) - # 12 SMS 1/4"TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ 1x2 BASE 2 @ SLAB (BEYOND) ROOF PER PLAN # 14x4" S.M.S. w/ 1-1/4" 0 FENDER WASHER AND NEO-PRENE GASKET @ 12" O.C. # 12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL CARRIER BEAM (SEE PAGE-2 FOR SIZE) (2) 1/4" DIA. MACHINE BOLTS THRU CARRIER BEAM & POST ALTERNATELY (4) # 10 INTO SCREW BOSS OF UPRIGHT 7' MIN. POST •OPTIONALEXTRUDED GUTTER IS ATTACHED TO 3" INSULATED ROOF W/#12x1"6" FROM ENDS 24" O.C. POST TO CARRIER BEAM CONNECTION SCALE: N.T.S. na y I L • I ° �1 k7 BASE PLATE ANCHORED TO CONIC w/ 1/4"MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24" O.C. MAX a ° ° 1-1 /4" CONC. EMBEDMENT TYP. •n ° 6" NOTE 3000 PSI CONC. WHERE PAVERS ARE PRESENT USE 5/16" SLAB/ FTG. TAPCON XL (RED HEAD MFG.) MASONRY 6x6-10x10 WWM FRONT VIEW ANCHORS TO PENETRATE UNDERLYING OR FIBERMESH CONCRETE FOOTING 2-1/4" (MIN.) DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS ANCHORING UPRIGHT TO FOUNDATION NOTES: l .- IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-1/4" MIN. (TYP.) 2.- WHEN FASTENING TO WOOD USE 1 /4' GALV. LAG SCREW IN LIEU OF CONC. ANCHORS AND ENSURE 2-1 /4' MIN. PENETRATION INTO STRUCTURAL FRAMING BENEATH (TYP.) 3.- NO SECONDARY ANGLE REQUIRED FOR 2X3 UPRIGHTS OR DOOR JAMBS. 2"X2"Xl/8" ANGLE CUT W/ (3) #12x.75" EACF EACH SIDE OF UPRIGHI SEE UPRIGHTTO CONNECTION DI OPTION # 1 FASTEN TOP OF HEADER TO INTERSECTING MEMBER w/ (4) #10 SMS (INTERNAL) 2" MIN. INTO SCREW BOSS OF INTERSECTING MEMBER EDGE BEAM PER PLAN mi ii ii `OPTION #2 li it ii ALUMINUM INTERNAL OR EXTERNAL n RECEIVING CHANNELw/(4) *10x.75" INTO COLUMN & (2) # 14x.75" COL. PER COL. PER ii INTO EDGE BEAM (`0.062 ANGLE PLANII PLAN CLIPS MAYBE USED) II II � I II II II II II II II II II II II II II II II II II II II II II II II II II II II II 2X3/ 2X4 COL. TO 2X3/ 2X4 EDGE BEAM CONNECTION SCALE: N.T.S. #144" S.M.S. W/ 1-1/4" 0 FENDER WASHER AND NEO-PRENE GASKET @ 12" O.C. ( )FIT LEG 2"X2"XI/8" ANGLE CUTTO FIT #14x4" S.M.S. w/ 1-1/4" 0 FENDER WASHER TYP. w/#12x.75" @ 1" SPACING MAX. AND NEO-PRENE GASKET @ 24° O.C. (4) PER LEG (MIN.) EACH SIDE TYP. FOR NON -LOAD BEARING WALLS ALTERNATELY CLIPS MAYBE USED 1/4" DIA. TAPCON 6" FROM ENDS PRIMARY UPRIGHT PER PLAN SIDE WALL UPRIGHT 24"0.C. MAX 1-1/4" EMBEDMENT PER PLAN INTO UNDERLYING CONIC. ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/(4) #1Ox.75" INTO GIRT OR PURLIN & (2) #14x.75" INTO BEAM OR UPRIGHT 0.062 ANGLE (4) #IOx2" SMS INTO SCREW BOSSES CLIPS MAYBE USED CHAIR RAIL PER PLAN *ANGLE REQUIRED ONE SIDE ONLY ATCORNER AND DOOR OPENINGS WHERE KICK PLATE IS INDICATED FASTEN W/ #10 X 9/16" SMS 6" FROM CORNERS 18" IN FIELD (2) #lOx2" SMS INTO ,ECK 1/4"DIA. TAPCON 6"FROM ENDS OR FASTEN W/#8 X9/16°SMS SCREW BOSSES OR TAIL 24" O.C. MAX 1-1/4" EMBEDMENT 2" FROM CORNERS 8" IN FIELD CLIPS MAY BE USED INTO UNDERLYING CONC. FOUNDATION PER PLAN SCREEN ROOM END WALL DETAIL SCALE: N.T.S.