Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING1/28/22, 1:48 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv%2bMluu6UrT%2boKMmB96zqssZWexXCYj%2bDD7iqh8lLCBaw%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL36841 Application Type New Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta, GA 30328 (770) 946-4571 mcollins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Paul Casseri Address/Phone/Email 2000 Riveredge Parkway Suite 800 Atlanta, GA 30328 (678) 402-9632 pcasseri@atlasroofing.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Certification Mark or Listing Certification Agency PRI Construction Materials Technologies Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard)Standard Year ASTM D1929 2016 ASTM D2843 2016 ASTM D635 2014 ASTM G155 2013 TAS 100(A)1995 TAS 110 2000 Equivalence of Product Standards Certified By 1/28/22, 1:48 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv%2bMluu6UrT%2boKMmB96zqssZWexXCYj%2bDD7iqh8lLCBaw%3d%3d 2/3 Product Approval Method Method 1 Option A Date Submitted 12/30/2020 Date Validated 01/07/2021 Date Pending FBC Approval Date Approved 02/09/2021 Summary of Products FL #Model, Number or Name Description 36841.1 Highpoint® Intake Intake Vent Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-187.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.6 Cert of Cert (HIGHPOINT INTAKE).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_Highpoint Intake.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.2 Highpoint® InvisaRidge™Exhaust Vent Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.4 Cert of Cert (HIGHPOINT INVISARIDGE).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_Highpoint InvisaRidge.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.3 Highpoint® Performance Ridge Exhaust Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.7 Cert of Cert(HIGHPOINT PERFORMANCE RIDGE ).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_Highpoint Performance Ridge.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.4 Highpoint® Performance Ridge XL Exhaust Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.5 Cert of Cert (HIGHPOINT PERFORMANCE RIDGE XL).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_Highpoint Performance Ridge.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.5 Highpoint® Stealth Ridge Exhaust Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-172.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.8 Cert of Cert(HIGHPOINT Stealth Ridge ).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_Highpoint Stealth Ridge.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 1/28/22, 1:48 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv%2bMluu6UrT%2boKMmB96zqssZWexXCYj%2bDD7iqh8lLCBaw%3d%3d 3/3 36841.6 TruRidge®Exhaust vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.1 Cert of Cert(TruRidge).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_TruRidge.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.7 TruRidge® All-Weather Exhaust Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.2 Cert of Cert(TruRidge All Weather).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_TruRidge All Weather.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 36841.8 TruRidge® Pro Exhaust Vent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof slopes from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. Certification Agency Certificate FL36841_R0_C_CAC_117C.3 Cert of Cert(TruRidge Pro).pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R0_II_TruRidge Pro.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Certificate No: 117C.1 Expiration Date: Nov. 5, 2025 Manufacturer: ATLAS ROOFING CORPORATION Manufacturing Location(s): 1448 Madison Ave. Grand Rapids, MI 49548 118 Celtic Circle, Madison, AL 35758 Product Type: Ridge Vent / Plastic Certified Standards: TAS 110(Table 14): TAS 100(A), ASTM D635, ASTM D1929, ASTM D2843, ASTM G155 ICC-ES AC132 ASTM E330*(design pressure -202.5 psf) *Design Pressure based on 2:1 safety factor CSI Division(s): 91.100, 91.120, 83.140 ICS Number Code(s): 07 72 26 Only products bearing the PRI-CMT Validation Program Mark will be considered as being included in good standing the Validation Program. Brad Grzybowski PRI-CMT, LLC Brian Wilson PRI-CMT, LLC Issued By: Reviewed by: CCeerrttiiffiiccaattee ooff VVaalliiddaattiioonn Product Identification: TruRidge Exhaust Vent Ridge VentTruRidge®A L L-WEAT H E RALL-WEAT H E R Options • TruRidge® All-Weather - with Filter & Nails Features • 4'x12" • NFA: 18 • Exterior baffle product • Our specially formulated polymer creates a stronger product than competition • Raises the cap less than 1” • No connectors, straps or gaskets • Self-sealing ends • Exterior baffles and louvers for extreme protection • Exceeds Department of Energy recommendations and all nationally recognized building codes when installed properly * Refer to the Atlas Signature Select® Limited Warranty for all system coverage requirements. Install the Complete System and Maximize the Coverage Atlas WeatherMaster® Ice & Water Underlayment Atlas Premium Underlayment Atlas Pro-Cut® Starter Shingles 1 2 3 Atlas Roof Shingles Atlas TruRidge® & HighPoint® Exhaust Ventilation Atlas StormMaster® & Pro-Cut® Hip & Ridge Shingles 4 5 6 6 5 4 3 2 1 Fits 3/12 to 16/12 pitches Classic Profile sq. in. per ft. Patent No. 9 5 4 0 8 2 3 ©Copyright 2021, Atlas Roofing Corporation ATL-215741-00 7/21 #AtlasProtects AtlasRoofing.com TruRidge® ALL-WEATHER Ridge Vent INSTALLATION INSTRUCTIONS Remove ridge cap shingles from the entire length of the ridge. Note: Delete Step 1 for new construction. Nail each additional section in the same manner until entire ridge is covered. A chalk line may be utilized to ensure vent alignment. Cut last piece to length and install with original uncut end to the outside. Install new ridge cap in normal manner, using 2-1/2” roofing nails, for 3/4” deck penetration or penetration through the deck, whichever is less. Nailing the ridge caps through the vent along the nailing line will secure the vent. Shingles may need to be trimmed. Ridge-to-ridge application requires a mitre-cut to maintain continuous ridge line appearance. Ridge-to-roof application requires a mitre-cut to maintain continuous ridge line appearance. Snap chalk line on both sides of the ridge and no more than .750 (3/4) of an inch from the peak. Note: If a ridgepole is present, cut a wider gap to allow a minimum of 1/2” air gap on both sides of the pole into the attic space - but do not remove more than 2-1/4” of roof sheathing material from either side of the ridge. Cut along chalk lines. Remove roof sheathing. Note: Slot should not be cut any closer than within twelve (12) inches of gable end, hip intersecting ridge. For appearance (to blend with the roof line), it is recommended that the TruRidge® vent be installed the entire length of the ridge. Position the first piece at one end of the ridge. Using 2-1/2” nails, for 3/4” deck penetration or penetration through the deck, which ever is less, anchor vent through preformed nail holes. Application and installation procedures are beyond the control of the seller or man- ufacturer. (Consequently, neither party shall be responsible for failure of the product when not used in strict accordance to instructions and specifications.) Technical Specs 18 NFA sq. in. per ft. 44 LINEAR FEET/CARTON 48” PC LENGTH 11 PC/CARTON 12 CARTON/PALLET UNIFORM BUILDING CODES R806.2 Minimum area. The total net free ventilating area shall not be less than 1/150 of the area of the space ventilated except that the total area is permitted to be reduced to 1/300, provided at least 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of space, measured vertically, with the balance of the required ventilation provided by the eave or cornice vents. See the published International Residential Code for additional information. Patent No. 9540823