Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 11-21-13-'6 13oq-c�oq,�-�'R�CEIY�A NQV'��1p� FORM 405-10. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAVANT ADDITION Builder Name: Street: OAK HAMMOCK Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing Addition 9. Wall Types (592.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=19.0 592.00 ftz b. N/A R= ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(0) d. N/A R= ft2 10. Ceiling Types (312.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 312.00 ft2 6. Conditioned floor area above grade (ftz) 312 b. N/A R= ft2 c. WA R= ft2 Conditioned floor area below grade (ftz) 0 11. Ducts R ft2 7. Windows(133.0 sqft.) Description Area a. U-Factor: Sgl, U=1.07 133.00 ft2 SHGC: SHGC=0.50 b. U-Factor: WA ft2 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 17.2 SEER:19.20 ,c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: WA ft2 a. Electric Heat Pump 17.2 HSPF:10.00 SHGC: Area Weighted Average Overhang Depth: 6.000 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems - None required 8. Floor Types (312.0 sqft.) Insulation Area a' Cap: N/A EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 312.00 ftz 9 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 6.98 Glass/Floor Area: 0.426 PASS Total Standard Reference Loads: 9.81 I hereby certify that the plans and specifications covered by Review of the plans and F'C•NE SrAl this calculation are in compliance with the Florida Energy specifications covered by this v�FO� Code. calculation indicates compliance `'' with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 .p.� I hereby certify that this buil ' as designed, is in compliance Florida Statutes. with the Florida Energy de. OWNER/AGENT: BUILDING OFFICIAL: DATE: -==z 7 -- DATE: <Fr, l. 11/20/2013 10:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 �' _ PROJECT Title: _ Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: DAVANT ADDITION User 1 Single-family Addition Bedrooms: 1 Conditioned Area: 312 Total Stories: 1 Worst Case: No Rotate Angie: 0 Cross Ventilation: Yes Whole House Fan: No Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address OAK HAMMOCK ST. LUCIE COUNTY ST. LUCIE COUNTY, FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce Fl- ST LUCIE _CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 312 2808 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 312 2808 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 85 ft 0 312 ftz ____ 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 338 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 312 W N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 312 ft2 0.11 Wood 11/20/201310:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Ornt Adjacent To Wall Type Space Cavity Width Height Sheathing Framing Solar Below _ 1 _ 2 3 4 N E S W Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood Main Main Main Main 19 24 8 192.0 ftz 19 13 8 104.0 ftz 19 24 8 192.0 ftz 19 13 8 104.0 ft2 0 0 0.75 0 0 0.75 0 0 0.75 0 0 0.75 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 2 3 N 1 Metal Single (Clear) 8 3 Metal Single -(Clear) W 4 Metal Single (Clear) Yes Yes Yes 1.07 0.5 30.0 ft2 6 ft0 in 1.07 0.5 15.0 ftz 6 ft0 in 1.07 0.5 88.0 ftz 6 ft 0 in 6 ft0 in Drapes/blinds 6 ft 0 in Drapes/blinds 0 ft 6 in Drapesiblinds None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 409.2 22.46 42.25 .365 8.7434 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 10 17.2 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 19.2 17.2 kBtu/hr 516 cfm 0.75 1 Ductless SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model # Collector Storage Area Volume FEF ftz 11 /20/201310:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 TEMPERATURES Programable Thermostat: Y Ceiling Fans: ^ Cooling[ Jan Heatin[X] Jan Feb HFeb Mar Mar r Apr I Ma j May Jun Jun rl Jul Jul Aug u Se Sep ri [] Oct [ ] Oct Nov Nov Dec Dec Ventin [ ] Jan Feb X Mar A r May Jun Jul Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/20/201310:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 I FORM 405-10 � Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: OAK HAMMOCK PERMIT #: ST. LUCIE COUNTY, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means, proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. r 11 /20/201310:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5