HomeMy WebLinkAboutEnergy Efficiency CodeJ y ]k FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAVANT ADDITION Builder Name: Street: OAK HAMMOCK. Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing Addition 9. Wall Types (912.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 912.00 ft2 b. NIA R= ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(0) d. NIA R= f12 5. Is this a worst case? No 10. Ceiling Types (804.0 sgft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=20.0 804.00 ftz 6. Conditioned floor area above grade (ftz) 804 b. N/A R= IF Conditioned floor area below grade (ftz) 0 c. NIA R= ft2 11. Ducts R fN 7. Windows(155.3 sgft.) Description Area a. Sup: Attic, Ref: Attic, AH: Attic 6 127 a. U-Factor: Sgl, U=1.07 155.33 ftz SHGC: SHGC=0.50 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.0 SEER:16.00 c. U-Factor: WA ftz SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: NIA ftz a. Electric Strip Heat 18.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.000 ft. Area Weighted Average SHGC: 0,500 14. Hot water systems - None required 8. Floor Types (804.0 sgft.) Insulation Area a• Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 804.00 ft2 b. Conservation features EF: 0.000 b. NIA R= ftz c. NIA R= ftz 15. Credits Total Proposed Modified Loads: 12.05 Glass/Floor Area: 0.193 PASS Total Standard Reference Loads: 16.20 I hereby certify that the plans and specifications covered by Review of the plans and Sr4 , this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates D�t-TtiE M g O ; $ calculation compliance �Q + with the Florida Energy Code, 'lilt E°:' .`.x':'';,`� PREPARE BY Before construction is completed ,: M,ti c' DATE: -- this building will be inspected for compliance with Section 553.908 v m �_. __......_..........._. I hereby certify that this building, as designed, is in compliance Florida Statutes. ♦� �� with the Florida Energy Code. COp WE OWNER/AGENT: __ BUILDING OFFICIAL: DATE: ..... _..... _._._......_._._...__.._.____..__........__-- ................ DATE: ...._. STr LUCIE COUNTY DING DMKON �rea�e�lewed 1Vo liaace . r.= Ravk ' d x Doi;,, ®� •,C3 - 9I5/2013 12:01 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: Building Type: Owner: # of Units; Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: DAVANT ADDITION Bedrooms: 1 User Conditioned Area: $04 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 1 Cross Ventilation: Yes Whole House Fan: No Single-family Addition Address Type: Lot # BlocklSubDivision: PlatBook: Street: County: City, State, Zip: Street Address OAK HAMMOCK ST. LUCIE COUNTY ST. LUCIE COUNTY., FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO_INTL_ 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 804 6432 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 804 6432 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 85 ft 0 804 ft2 ____ 0 0 1 ROOF # Type Roof Gable Roof Materials --Area Area Color Solar Absor. SA Emitt Tested Emiif Deck Pitch Tested Insul. (deg) 1 Hip Composition shingles 871 It' 0 ft2 Medium 0.96 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic - Unvented 0 804 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 CathedrallSingle Assembly (Unvented) Main 20 804 ft2 0.11 Wood 9/51201312:01 PM EnergyGaugeQD USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 . r - WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o mt._........... _. -To ------- Wall Type R-Value---.Ft__In.-__Ft-.In.._Y_Qr - _ 1 N Exterior Frame - Wood Main 19 37 8 296.0 W 0 0 0.75 0 _ 2 E Exterior Frame - Wood Main 19 20 8 160.0 ft' 0 0 0.75 0 _ 3 S Exterior Frame - Wood Main 19 37 8 296.0 ft2 0 0 0.75 0 4 W Exterior Frame - Wood Main 19 20 8 160.0 ftz 0 0 0.75 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation int Shade Screening 1 N 1 Metal Single (Clear) Yes 1.07 0.5 30.0 fF 6 ft 0 in 6 ft 0 in Drapesiblinds None 2 E 2 Metal Single (Clear) Yes 1.07 0.5 20.0 ft2 6 ft 0 in 6 ft 0 in Drapes/blinds None 3 E 2 Metal Single (Clear) Yes 1.07 0.5 6.0 112 6 ft 0 in 0 ft 6 in Drapes/blinds None 4 E 2 Metal Single (Clear) Yes 1.07 0.5 15.0 ft2 6 ft 0 in 0 ft 6 in Drapesiblinds None 5 S 3 Metal Single (Clear) Yes 1.07 0.5 15.0 ft2 6 ft 0 in 6 ft 6 in Drapesiblinds None 6 S 3 Metal' Single (Clear) Yes 1.07 0.5 6.0 It' 6 ft 0 in 0 ft 6 in Drapesiblinds None 7 S 3 Metal Single (Clear) Yes 1.07 0.5 10.0 ft2 6 ft 0 in 0 ft 6 in Drapesiblinds None 8 W 4 Metal Single (Clear) Yes 1.07 0.5 53.3 ft2 6 ft 0 in 0 ft 6 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1054.5 57.89 108.87 .365 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 18 kBhAr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:16 22 kBtu/hr 660 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ftz 9/5/2013 12:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 DUCTS — Supply — ---- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 127 ft2 ^Attic 20 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans - Cooling [[ �Jan Heating (X) Jan ((jj Feb [X) Feb j( Mar [�S� Mar (] j ]r A r I Ma May Jun Jun Jul Jul Au AuSep rl Se Oct WOct Nov Nov H Dec JCDec Ventin [[ 11 Jan [[ ]) Feb [[ { Mar [Xl r May Jun Jul Aug Se Oct Nov [ 1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 T 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) 68 68 68 68 68 8 68 68 68 68 PM 68 68 68 68 66 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/512013 12:01 PM EnergyOauge@ USA- FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: OAK HAMMOCK PERMIT #: ST. LUCIE COUNTY, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. ! Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have, vapor -retardant covers or a Iiquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78°% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat ?10kW must be divided into two _—. or more stages. ....._..._ __.....__._ Ceilings/knee walls 405.2.1 . R-19 space permitting. 9/5/2013 12:01 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5