Loading...
HomeMy WebLinkAboutLetter - Plan Review CommentsJoe Cicio From: Joe Cicio Sent: Wednesday, October 16, 2013 1:48 PM To: patoakhammock@comcast.net Cc: Joe Cicio Subject: Permit Number 1309-0097 Attachments: Repo rt_FL_Review_Comments_NoncompIianQrf[l].pdf Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional , contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, o e . Gticiv jspl�M Plans Examiner II Standard Building Inspector 0 Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner o St. Lucie County Planning and Development Services 772-462--1553 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Planning.& Development Services Building,& Code Regulation Division 2300'Vlrginia Avenue Fort Pierce, FL. 34982 Phone:(772)4624172 Fax:(772)462=6443 PROPERTY INFORMATION Address: 3327 Perimeter Rd City / State / Zip: Palm City, FI 34990 Parcel #: 4436-510-0033-000/7 Zoning: AR-1 APPLICATION INFORMATION Permit Number: 1309-0097 Permit Type: Building (Miscellaneous) CONTRACTOR INFORMATION Contractor Name: Patrick C Weber Business Name: Oak Hammock Construction Inc Business Addr: 5240 Rosewood Lane City / State / Zip: Vero Beach, FI 32966 REVIEWS AND COMMENTS REVIEW COMMENTS 1 Owner(s): Dianne B Davant Jurisdiction: Saint Lucie County Lot#: 29 Block: Stories: Automatic Sprinkler System? No Fax Number: 772-336-2952 Email: Patoakhammock@Comcast. Net Review Type Status Reviewed By Date Started Date Completed Date Released Documents Missing Pending Deanna Givens 9/17/2013 Comment: RECEIVED VEG PERMTIT FILED UNDER "D" FOR DAVANT - $100.00 FEE Environmental - Veg Permit Req Complete Ben Balcer 9/16/2013 9/16/2013 Comment: Environmental Review Complete Ben Balcer 9/16/2013 9/16/2013 Comment: Front Counter Review Complete Deanna Givens 9/9/2013 9/9/2013 9/912013 Comment: Plans Examiner Review Incomplete Joe Cicio 10/15/2013 10/15l2013 Comment: SURVEY DIMENSIONS DO NOT MIRROR THE SUBMITTED PLAN O.S.DIMENSIONS AND THE PLANS ARE REVERSED FROM THE SURVEYS * PLEASE CORRECT Comment: BOTH SETS OF PLANS FROM CAROLINA CARPORTS MUST BE SIGNED, DATED AND SEALED AND WHERE IS THE CARPORT BEING CONSTRUCTED * OBTAIN DUPLICATE SEALED LETTERS FROM THOMAS BECHTOL 10/15/2013 P.E.THAT THE " CAROLINA CARPORT " IS APPROVED FOR HABITABLE SPACE IF THIS IS THE INTENT * MY CONVERSATION WITH MR.BECHTOL CONCLUDED THAT THIS IS NOT ALLOWED FOR ANY PART OF HIS STRUCTURES AND THESE STRUCTURES ARE RESIDENTIAL UTILITY UNITS 10/15/2013 Comment: SUBMIT ALL BUILDING ELEVATIONS AND ALL WINDOW SIZES DESIGNED BY ARCHITECT 10/15/2013 Comment: WHAT IS THE INTENT OF THE EXISTING 10.33 X 19.9 STRUCTURE 10/15/2013 Comment: SUBMIT DUPLICATE PLUMBING ISOMETRIC DRAWINGS FOR THE WASTE LINES * SHOWER MINIMUMS ARE 30" X 30" [ fbcr 307.1 ] 10/16/2013 Comment: SUBMIT DUPLICATE TRUSS LAYOUTS FROM THE MANUFACTURER WITH DUPLICATE SIGNED, DATED AND SEALED TRUSS ENGINEERING CUT SHEETS ALL REVIEWED AND APPROVED BY BRADEN AND BRADEN Planning 4 Development Service's REVIEW COMMENTS Building & Code Regulation Division 2300;Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 'Fax:(772)4624443 Page 2 10/16/2013 Comment: SUBMIT A SEALED COPY OF THE SOIL TESTING FOR THE FILE PER NOTE: 6 Comment: SEE DOOR SCHEDULE ON SHEET 1 ** DESIGN PRESSURES ARE NOT ON THE PLANS NOR IS THERE A 10/16/2013 PRODUCT APPROVAL CHART ON THE PLANS FOR REVIEW * SUBMIT DUPLICATE. SIGNED, SEALED AND DATED ST. LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS FOR ALL EXTERIOR CLADDING / COMPONENTS 10/16/2013 Comment: PROVIDE 1 36" EXIT DOOR FROM THIS AREA [ fbcr 311.2 ] Comment: BOTH BATHROOM DOORS ARE 30" ** 1 BATHROOM DOOR MUST PROVIDE A 29" CLEAR OPENING [ 32" 10/16/2013 DOOR ] ** DEPENDING UPON WHICH BATHROOM COMPLIES WITH ADA [ 404.2 ] CODE ALL SWING DOORS TO THAT AREA MUST BE COMPLIANT AS WELL * PLS CORRECT ALL PLANS 10/16/2013 Comment: PAGE 1 OF THE ENERGY CALCS MUST BE ORIGINAL SIGNATURED, PERMIT APPLICATION STATES 631 S.F., ENERGY CALC STATES 804 S.F., E-1 STATES 639 Comment: INSULATION FACTORS ON PLANS DO NOT CO-INCIDE WITH ENERGY CALCS * MUST COMPLETE ALL 10/16/2013 INFORMATION ON THE CALCS IN CONFORMANCE WITH THE ENGINEERS PLANS AND COMPLETE ALL REQUIRED SECTIONS OF THE CALCS [ PROJECT INFO ETC: ] ROOF IS NOT SHINGLES, ATTIC SHOULD NOT BE UNVENTED, HOT WATER IS REQUIRED [ see P2801.1 ] / CALC STATES NONE REQUIRED 10/16/2013 Comment: REMOVE THE ELECTRIC METER DETAIL FROM E-1 [ cannot have a separate service ] * SHOW A LOAD BREAKDOWN ON THE MAIN PANEL WITH A SUB PANEL BREAKDOWN FOR THE ADDITION 10/16/2013 Comment: ARCHITECTURAL PLANS MUST DETAIL THE JACKS AND HEADER SIZES, MATERIAL AND STRAPPING Comment: SHOW THE MECHANICAL EQUIPMENT LOCATIONS AND REQUIRED TIEDOWNS FOR THE COMPRESSOR 10/16/2013 UNIT ** IF TRANSITIONING FROM THE EXISTING MECHANICAL SYSTEM MANUAL J CALCS MUST BE FOR THE COMPLETE SYSTEM NOT JUST THE ADDITIONS 10/16/2013 Comment: PLEASE CORRECT ALL NOTES ON ALL PLAN PAGES SO AS ALL PAGES COINCIDE WITH EACH OTHER AND REMOVE ALL NOTES WHICH DO NOT APPLY 10/16/2013 Comment: SHOW THE REQUIRED ATTIC ACCESS ON THE PLANS 10/16/2013 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE Zoning Review Incomplete Lydia Galbraith 9/11/2013 Comment: PLEASE INDICATE THE EXISTING AND PROPOSED FINISHED FLOOR ELEVATION ON THE SURVEY. SEE ST LUCIE COUNTY LAND DEVELOPMENT CODE CHAPTER 7-04-01 FOR MINIMUM FLOOR ELEVATION REQUIREMENTS. PLEASE INDICATE THE ELEVATION OF THE CROWN OF THE ROAD. THE STRUCTURES ARE REQUIRED TO 9/11/2013 MEET 18" ABOVE CROWN OF THE ROAD. PLEASE INDICATE THE FINISHED FLOOR ELEVATION OF THE 10.24'X 19.20' EXISTING PREFAB BUILDING 9/30/13 SUBMITTED NEW SURVEY. FIFE IS NOT 18" ABOVE CROWN ROAD. CONTRACTOR WILL WRITE LETTER TO REQUEST RELIEF OF THE PROVISION. 10/7/13 RECEIVED LETTER FORWARD TO LESLIE & MARK FOR APPROVAL. 9/11/2013 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. TEMPORARY SPECIAL EVENT PERMIT _.... .... ............ ........... ABOVEGROUND POOL PERMIT ................. ............ T ..�...................... _.................................................... ...... Number of Banners: ._ Pool Dimensions (m feet) Length Number of Days:, .,„_. ( Pool wall must be a minimum of 10 feet Width: i r)icnlav Perind Start Tate•' a,.m,..,aa.P,a.,,..—H.— T-Teivht ahnve ornnnd• http://code/(S(eelOhupg2craybopkzrvc323))/Add EditPermit.aspx 11/7/2013