Loading...
HomeMy WebLinkAboutAPOC INSTALL NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT APOC, sub of Gardner Asphalt Corp. 4161 E. 7th Avenue Tampa, FL 33605 (813) 248-2101 Evaluation Report 1m-GG-19-FBCER.06.19-R2 FL26482-R6 (HVHZ) Date of Issuance: 06/19/2019 Revision 2: 12/17/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: Gardner® Roof Underlayments, for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/17/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC. NEMO|etc. NEMO ETC, LLC Evaluation Report 1m-GG-19-FBCER.06.19-R2 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL26482-R6 (HVHZ) Gardner® Roof Underlayments; (813) 248-2101 Revision 2: 12/17/2020 Page 2 of 4 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Gardner® Roof Underlayments, as produced by Gardner Asphalt Corp., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year TAS 110 Material standard TAS 103 2020 3. REFERENCES: Entity Examination Reference Date Miami-Dade (CER1592) HVHZ Certification 20-0714.01 10/01/2020 NEMO Traceability FBC Cross-Listing 12/10/2020 PRI (TST5878) TAS 103 GGI-196-02-01 07/26/2017 PRI (TST5878) ASTM D1623, TAS 103 GGI-201-02-01 01/26/2018 PRI (TST5878) ASTM D903, D1970 GGI-211-02-01 06/06/2018 PRI (TST5878) ASTM D1623, TAS 103 GGI-202-02-01 08/09/2018 UL, LLC. (QUA9625) Quality Assurance Service Confirmation 02/12/2020 UL, LLC. (QUA9625) Quality Assurance Florida BCIS Current 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.1 Weather-Armor® FT3 Tile Underlayment TAS 103 Springville, AL nominal 60-mil thick, self-adhering membrane of elastic polymers, bitumen and polyester and glass reinforcement 4.2 Eagle-Armor by Apoc TAS 103 Springville, AL nominal 60-mil thick, self-adhering membrane of elastic polymers, bitumen and polyester and glass reinforcement 4.3 TriBuilt Fleece Tile Underlayment FRSA/TRI 09- 18 Springville, AL nominal 60-mil thick, self-adhering membrane of elastic polymers, bitumen and polyester and glass reinforcement 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC High Velocity Hurricane Zone jurisdictions only (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Gardner® Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO|etc. NEMO ETC, LLC Evaluation Report 1m-GG-19-FBCER.06.19-R2 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL26482-R6 (HVHZ) Gardner® Roof Underlayments; (813) 248-2101 Revision 2: 12/17/2020 Page 3 of 4 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC HVHZ Section: TAS 110(S10), RAS 115 TAS 110(S11), RAS 118, 119 & 120 RAS 133 TAS 110(S11) RAS 130 Underlayment Asphalt Shingles Clay and Concrete Tile Metal Panels or Shingles Slate or Slate-Type Shingles Wood Shingle or Shakes Mechanical Attach Adhesive- Set Weather-Armor® FT3 Tile Underlayment YES YES Yes (See 5.6.1) YES YES YES Eagle-Armor by Apoc YES YES Yes (See 5.6.1) YES YES YES TriBuilt Fleece Tile Underlayment YES YES Yes (See 5.6.1) YES YES YES 5.6.1 Adhesive-set tile is limited to use of the following underlayment / tile-adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE-ADHESIVE COMBINATIONS1 Underlayment Adhesive HVHZ Product Approval Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment DAP “Touch ‘n Seal StormBond Roof Tile Adhesive” NOA 20-0309.05 Dupont “Tile Bond™ Roof Tile Adhesive” FL22525 ICP Adhesives “Polyset® AH-160” NOA 17-0322.03 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS Underlayment Substrates Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment ASTM D226 felt Structural concrete* *Note: minimum 73°F ambient application temperature for structural concrete 5.8 Attachment Limitations: See Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment Adhesive-set tile (Polyset® AH-160) 30 Adhesive-set tile (Tile Bond™ Roof Tile Adhesive or Touch ‘n Seal StormBond Roof Tile Adhesive) 90 Mechanically attached 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment Flat or Lugged Max. 10-tile stack 6:12 1 Refer to Tile Manufacturer’s Florida HVHZ Product Approval or NOA for Attachment Resistance Expressed as a Moment Performance. NEMO|etc. NEMO ETC, LLC Evaluation Report 1m-GG-19-FBCER.06.19-R2 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL26482-R6 (HVHZ) Gardner® Roof Underlayments; (813) 248-2101 Revision 2: 12/17/2020 Page 4 of 4 6. INSTALLATION: 6.1 Gardner® Roof Underlayments shall be installed in accordance with APOC, sub of Gardner Asphalt Corp. published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Approved Assemblies: 6.3.1 Deck Type 1: Wood, non-insulated Deck Description: Min. 19/32-inch plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered Base Sheet: One or more plies of ASTM D226, Type II with min. 4-inch side laps and min. 6-inch end laps. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6” o.c. at the laps and 12” o.c. at two (2) equally spaced, staggered center rows. Cap Ply: Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment, self-adhered in accordance with published instructions and back-nailed (if applicable) in accordance with applicable Roofing Application Standard. Surfacing: FBC HVHZ Approved prepared roof assembly, per Table 1. 6.3.2 Deck Type 3: Structural concrete, non-insulated Deck Description: Min. 2,500 psi structural concrete System Type F: Underlayment adhered Underlayment: Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment, self-adhered in accordance with published instructions. Note: Minimum 73°F ambient application temperature for structural concrete Surfacing: FBC HVHZ approved adhesive-set roof tile, subject to published limits of use. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC. (QUA9625); (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT –