Loading...
HomeMy WebLinkAboutEngineering PackageENGINEERING PACKAGE 7!" Builder: JDR HORTON / STATEWIDE Project: 7 320 CREEKSIDE Model/Building: 182EC,E Lot Alt: 102 H Lot:.-;�.... 4 ._�..-._.-_..��. Block: Unit: Address: E ........................................................................................ JobNumber: `N3.34501 Revision Date: New Load #: CARPENTER CONTRACTORS OF AMERICA, INC 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 .J'j N ALPINE ,J March 13,:20.19 ANITWCURANY Mir. Bob Michaelis Carpenter "CcOtraictott 6fAmerick.1rid. .0 Avenue 0, Nbiihwesf Witit6f Ha&On,.FL 33880-6201 Re: AltprnapV6 Installations. for 6 single ply carried truss with a width Jess than the hanger width, .9nd wood.b . I . o tking to: achieve full design loadvallue-10'r fotpry-*io.un*t6.'d'.'hange'r.attad'h*i-n6nt'*' on..a, one Ply Supporting girder (Reference detail WA3M2).-. Pear Bob,: Fora single ply carried truss with' 'a width 16st than the hanger Width -you -can in;qql1a. prefabricated jack. scab .truss: for wood.filler bIoQkihgi. The chord . - sites- chord.grqO J es, and -A piaECtdhhb.,dt r pi t (s) to be -the. same as the single: ply'zamod truss. The pr6fabCic"atiad lock cab truss have a.. minimum length, of 48" and Will have.a minimum pit6h-:of,5/-12... The single ply- careied �fruss shall have..a reaction of or lei�s. Attach pre'fg*b"d'�'o8t"6.d.j'..ac'k:'s-c.a.b.tr.-uss..wit't�twQ.('2)'toWs'of 0.428"Aff"GLin. Nails at'2" jw ro*,..stag9er6d -_".;(See loiqreI__4616w). Pl6asb-bef& t6the" Simpson Strong -Tie. Catalog 0--ic" , 201:9.. Page 216: 1=igqr.e:-3 for more information, Figure Pora single- pl' `,gied '' � thati quires Woodblockin ' to,adhio'veftlll design load value for face -mounted mounted er re 9 .,e-. hangers -.attach. one wood.- block to .the back face of the single :ply girder with . : . t . he' same size: and qrade..as'thd bottom. bhbtd, Of the single ply girder. The wood block length to be such that'Ahe'-wood blocking extends to each adjacent' I points fWebs:.a0d b6,ttom chord intersections): Attach wood pane p Gun Nails 3.0" applied to: the 6760 Forum Drive Suite 305, b.flan.d.o; FL 3282-! .48Qq) Vww.alpineitw.com � ALPINE mNE single ply �� am���n�Ile to'the. _..... ... ... _-..... .......... ____-_______- ..... ............... ... _-__--_--__-'_____---......... —........ .... '.... ... ........... .............. '—_—� - The ' of tuj�afbrVvmwdfU|��bb��d' ���mxzm� �bo full,' - design load. �valuehangers must be.apprpved the. hardware manuf4durer., At! edoe #hd ' all nail mutt be tb OeeVbht.spIitti'hqof \mood- If!can,beCfany further �youh�veanyq o�ennaa ' ' `Chief Engineer ~ 875OF6r'UhMOhve.8dity�06,[Nnhdn,FL32821- -.8790- | 422'8.685 ALPINE April 261:2019, Mr. Bob Michaelis Carpehter Contractors -of Afn e rida, Inc. AvenueG.. Northwest Winter H6v6n, FL 33880-6201� Dea.r. Bob, .R6; Stron'gback bridgiho'. on tb6f. trusses. I understand -there is some- bohdEirn over our recommendations f6rstrdngback bridging on. roof trusses: i it irementoUthe Strongback bridging for roof trusses is not.a -requirement' pf:ANSI-�TPI 20-14 nor is i.. a re u... q BuildingComponent -Safety- Infoemation . -(B ti*()� But ry .0 strongback bridging roof*- tm§ges is .-.-..-.-rec-oMiliep($eo...by.�CarDehtef- COhtrktbrs of. .. America -S *.6h back bridgingh o . - functions: One, bridging aligns th.e.bottoM.phpF.Os-.pfter they: are. setisojbev are uniform along the, ceiling line and h;,, Os .'with _ceiling -'serviceability Twoj bridging reduces f6lativd deflecti6h of. adjae:66A.-tfussb8i. Str9ngba.ck b(Idging'.do6s hot;Or6Vent-pr r6duc6werall indiVidUal deflection, especially any r66f"VUs96sw .. ....... ........ fjectjo_. than 1/4 9 inch. Sirongoack The outer ends .of'fh;b'gtroog'!:iap'kbridging shaft be.-affpched.-to awall or aripthorzecure end..restrain . t)- -of a.s.sppcifie6by the Engineer of R6bofd6rAh& Building .Designer: Strongback- bridging be fia. minimum 2j(6 -horhinat lumber. oriented - 9 e o., with the depth -vertical:. Attach with (8) 16d -common nails (0.16Z"A51 nails at each intersecting member: When -extending the- strdngbatk bridging overlap by- at. a.minimpm of. two trusqps. The location of. the: pti-pogback. 6d;dging` ipaV.be:spp6ifted*O'y-',�h'eTruss Manufacturer,. Engineer 6f-R66ord,.Pr Building De§idriet.-'F51ei��se'-refe;r-:to- BCS . I "St - rang. backing Provisions" or to Alpine.:MOR-18131014 defail for more.. information. The. graphic shoWh is f6r .generic illustrative pdrp6se only. ,676OF6rumDrive:8uite3O5,Qriando,.FL32821'-(800).521A' 790�­(8631.42_2-8685 *vM--.W P­ineitvV.com.� ALPINE iN it U L- -L L- k.jv. I Figure-1, If I. -Clain be of any further sissistance. or ify.pu have any questions; plea give me a Call. Williaitn, H.,Knck. PAS. Chief'.Eng'k'q.eer Alpine an jTW. _ Company Engineering 'Department -Oeldn,do-, 1702821. 675.0. . Forum Drive Suite.366, Cd6nidd, FL 32821 (800). 521*-9.790'- (863).422-8685* NO TD (P) -10d COMMON .4 -STRON GBACI< tPIDGING RECOMMENDATIONS' 7 lk- All scab -.on b(ocks shall, be: a. .minimum. `2X4. BUTT .STRONGBACK BRIDGING TOGETHER 4 "stress graded lumber;' : lo-AIL strongback bridging .and bracing shaft minimum 8x'6 'stress : gra61ebl* IuHber..' ►--.The put -pose, of strondback bridging MgIsI: t..c J. 'ATTACH SCAB WITH 10d:B13VGUN oxf sharing be'tween :trusses,_ -es,. 4' '-0.' �MAPS!xUf). 14AILSIN'B ROWS. 6 Af� develop(o ;SCAB D.C. r?s,�41.j;lng In an overall Incredsg- In, -the NOTE, 'IN LIEUJIF SPLICING AS'SHOWN, w stiffness. of -the. floor system; LAP-* MEMBERS- FOR:AT LEAST 13NE TRUMAPACING strop back brldglng� po'_4M.-tIoh6cI- ;as shown In STREINGBACK'SIRIDGIN15 SPLICE DETAIL cletalls, 'Is recommended at 101 =01.o.c. (m ax;) J. and .2.­oq�101 the 'preferredattachment me-thods t 'Ms. 'b'rWbInV -.,braC1hg t g Ir �qre- some Imes 101 STRONGBA.tk m1s*akentyuse.1 nt'erchangeabl. `qcihIs- and yM. Impqrtantt 'structural t4Oq uIremeh.t. ' bf .any 1*0 Q*t^' or roof 'system, R.efe Truss. Design Drawing (T.DD). TOr the; ..bracing rLm.quW-'Oments T.6'r each jndIVIbIUAk truss compomen 'Bridging;' partIcUlarly "strongbaCk.-"4bridiging".1s.:d. rec6mmehdatloh for 'a' -truss system to. help con-Wo vibra-tloe), In: addition: -to --alclIng In the: distrIbLitIon of pblnt tbads between adjacent. truss,k * ­ -5trongbac lc�rldglng servesto reduce STRONGBACK BRIDGING.; -REAM I REQUIREMENTS W10 1V None re uMed bounce. Or residual vjbrI n'ro:5tu Ing: from moving point ipqcit., :5uch as foo+st.eps, 4) STRONG3A2CKK,. TM AT EACH -END, Wit'M 2,raw Q rf Mi. in P*1s) V to pdft� The performance of all . floor systems tems are enhanced by. the. Int�tatta-tlbh bt :strop back I nclect bticiglng arid ther6for'6:1i�. strongly recommended ATT'At-HME'NT A by Alpine. For adclItionat ln'fdrpiat r; Ioh regarding .137trongbo,5�4 O bridging, refer t.0-.wSz,(BuILcIIng Component Safety Information). ANffWCWPAWI1Z7&wi',* an 9. brackv Inatµlatr, tw-- *r , . ­ rh .— I 13723.KWrpbrt Delve ..shm , Thi xuroMny-wW uft Wto 200 ww _AA��Is 1-1� w ANA .1 MaNftw MOMS. Mo 63043 1 a i�. stwi*": 1. — I _R ZATTACH S.TRUMACKJ. TO BM7134. DOW WI 0110 - 3' SCRE% :YES Rf"'el 'ffil N6. 70861. . 0 L L: Psr esx tPSF QC 3 - DL PV* FC A L L ?SF t'.i�m PSF -1 .6 6 4 Oki '"130+1,c'l�li � `�FI4 ��•' .�l�,�Bl�i;i�,�6'r•I�.�sd �'�n�r H�3t# 31F1t5k�r1��.:�k�'.�.' situ ' irWm9l :T. "1°kv1,1�E LkE.• r cl e (1�"Klfi f t41I vT�E�� .'ONV S V-iU "YaWfl- 1, ?��Ik11 H.5 a.SfIi 380 : �1Cld .z M. "fVx#f3E`1 4' ND f�l '' A. ? Cracked or Broken Member-: Repair 'Deto'dt Load. Duratlon' = 0% This drawing specifies repairs for a truss with broken chord Member forces may be Increased for Duration of Load or web member, This. design Is valid only for single ply trusses with 2x4. t 2x6 broken members, :.NO more than one break per chord panel, ' and no more than two breaks per truss, are allowed; Contact the. truss' manufacturer for any repairs. that do :not ., ? comply with this detail, (B)' = Damaged Area; 12'. mak _ length:.•of damaged section J � (L) = Minimum rlalling distance on: -each side of damaged area CB)'' i (S) = Two 2x4 or two 2x6 side members,same size, grade, and species as damaged member. Applyy one scab per face, . Minimum side member lengths) _ (2)(L) + (B) Scab member length '(S) must -be within the broken panel. Nall into 2x4 members. using two (a) rows at 4' o,c„ rows staggered; Nall Into 2x6 members. using three (3) rows at 4' o,c„ rows s • aggeried, Nall using 104 box or gun nails C0,1281x3', min) Into each side member> The maximum permitted lumber grade for -use with this detail Is Limited to Visual grade: 41 and MSR grade 1650f. This repair detail may be used for broken connector plate at mid -panel splices. This repair detail mnyy not be used for damaged chord or web sections occurring within the connector plate area. Broken chord may not support any tie -In loads, S. L L a �Typlcat + O + O + O + O O + O + O + O + Str agger + = Back Face Wcl Box (0.128' x 3', min) Nallsl 0 = Front Face 2x4 Member - Double Row Staggers 2x6 Member - TrIoie RowStaooere Nail Spacing Detail JACS�tNF;; AN 17W COMPANY 17380 Lakehonlpp��lve E}Ah cµy, Mo 6awJ45 FRNSND TORAUmWoFtTANTux H THIS MAK READAV= ALLCK)WCM Maxlmum Member Axial Force . Me'mber!:• Size L SPF-C HF DF-L SYP Web DnCy'. " ' 2x4. `. 18' •. 620# 635# 730# 8004 Web .pnly ! 2x4- 18' . 975# 1055# 1295# 1415# Web or, Chord 2x4 24 975# 1055# 1495# 1 1745# Web Y 'gr Cord 2x6 1:465# 15B5# 2245# 2620# Web or Chord 2x4-.1910# 30' 1960# 2315# 2555# Web or. Chord 2.x6 2.230# 2365# 3125# 3575# Web .or Chord 2x4' 36, 2470# 2530# 2930# 3210# Web or Chord 2x6 31535# 3635# 4295# 4745# Web or Chord 2x4 42 2975# 3045# 3505# 3835# Web or Chord 2x6 43954 4500# 52254 5725# Web or Chord 2x4 '48, . 3460# 3540# 4070# 4445# Web. or Chord 2x6 5165# 5280# 6095# 6660# JNSTALLM. have a properly aiiazhed id ceI Locations shorn Far pernenent lateral rest—InT of : hove braeknp Nsialled per I ae )s, 17 or 110, os oppptteable,. Apply plates to eadt roes and position as shown obove and an the Jolni letaes, unless rated othervlse, r io dranrwngs 160A-2 Iar standard plat. paSklane, Hite, a division of 17W IWdhC Conponenis OreuP Inc, shall not be responsible For a devlat4 drartng, any /allure to bultd the •la•uss M eonfarnonce with MSIMI 1, or for handd 9, Shipp dlatlon L'bracing of irusses. seal'm ihh drastrnp or cover poppee tlsift iNs dravk%0 ltdeaies oesepianes Of professbnd rim nzPWW llty sotsly for the deegn shown. The sedtobllty and use of iNs dra►fn0 ayitsy structure 1e flit rnpenabOW oP 1M IMIc" Daignar per ANSYMI t Sect. For ears Infornaiton see thls Jobs general notes ppao a and •geese web slt►sn ALP1N6, wvv.a r1*1tw,eenl TPD weetpyat.orgl S1CN wwwebelnductay.orgl 1CG wwwJecsafs,ors ' Hlntnun L Dktnnee e L S Hlntwn B \% L Hlhtnum 7i L L Dlstoree L REF MEMBER REPAIR DATE 10/01/14 DRWG REPCHRD1014 e � SPACING 24.0' MAX a A. I ." lvogs. *304�, 'hT41-am.gMTIMAO PA-,zmr41 4. Ali ngz= w* T/�rrI Z - p 0 0 0 0 cn 4-V 0. ;w rM Ot s .. .. --m T.. +ad. Poll V.q. *A"'"'. * .-;6 , .4kw Am. STONST-MbW VMHO 0 0 0' 0 'IQ U VSR!q1A 'Pu �,Vtb/`Ot -,ijya Z, L Oz O.'T -,1a as Offillr 13 �A. J v R04-'Q'N 0 .43". .q. su -jqm .10104 AOII9A UO'sAk 11DA0.1001-m"41. G�O!P? jlp�� . ?APjkQUlY)Ri%%50^1 i I P%O. d ?y-.J?;sp.am3 p MI" DO pug' 1.9 1.0 '91jam uc, WW66 jo . )00Vat .90 9 WorAO 2�A- 0 . %UI ul 'ONIb"' ;;%*r; 4 WV-Rqdglli*' 'ET' S,ujp- rr. t0aA SROYIVIO�'W. 1 . d . AL NJA V�M` -OT. Am o ---rfircq W,0.Qq-ak!Pt-d-- '4, tioild -dox at-av sV-J.� -wi", 9'. . S -acq PgT v x3pluad-w `9, OP p 1511"iRal. PoItt I. AX132A '1411mg. R .14R4 601418-la ul q63oup Ualm• 1411530H Mp P. .94. 11 d4v P. 'g. .............. V-14 10�3 "Yoe 17% nO N04.:?-tdV. ajo stjollvool alddlyo ley'. d 003 ql AMMO It?-t-ve lmgalfRlB Sirnpson.Strong-TeO Wood ConstrucUon Connectors Face -Mount Hangers - I -Joists, Glulam and SCL wce' These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. .J A OEM Actual =' T Jolst " Siie (in.) , = Model No Carded-- ".Member " Dimensions (in:} , Mjn l Max Fasteners (in:) Allowable Loads �. Code Ref.' cS �, Web o Stiff, = Regd.� i W iiii v H - ', B Face - Joist " DF/SP Species Header SPFIHF �` S 6i cies Header Uplift (160) Floor (100) Snow: (115) Roof (125) 1 Floor (11100): Snow, {115) Roof, (125)" IUS2.56/16 - 25/a 16 2 Min. (14) 0.148 x 3 - 70 1,660 1,805 1,805 1,425 1,555 1,555 Max. (16) 0.148 x 3 - 70 1,805 1,805 1,805 1,555 1,555 1,555 21/z x 16 MIU2.56/16 - 29/16 157/16 21/z - (24) 0.162 x 3Yz (2) 0.148 x 11/z 230 3,455 3,920 4,045 2,970 3,370 3,480 U314 ✓ 29M6 101h 2 - (16) 0.162 x 31/z" (6) 0.148 x 11/z" 970 1,945 2,205 2,375 1,67511,895 2,045 HU316 / HUC316 V' 29A6 141/a 21/z - (20) 0.162 x 31/z (8) 0.148 x 11h 1,515 2,975 3,360 3,610 2,565 2,895 3,110 IBC, Yz 2x18 :. Mik2 6/f8 - � 24/6• 17ti6; 2'/z - `-(26) 0162x311a� (2) 0.1¢8 x 11/z- 230 3,745 4,045' 4,045 3,220 3"480 3,480, LA "=H0316/HUC316,,, --',- �� "'-✓ 2h6. --1Ala� 2Yz =: "(20)0162x31/�': (8)0148x1'/z;,'!°1515 2,475; 3,360!.3,610 2.565� 2,895 3,110' 21h x 20 MIU2.56/20 - 29/6 197/6 2Yz - (28) 0.162 x 31/z (2) 0.148 x 11/z 230 4,030 4,060 4,060 3,465 1 3,495 3.495 211zx22 to 26, MIU2.56/20 ✓ �29/,6 19?tis::" 2Yz° - 1 (28) 0162 x 3 /z; (2) 0.148 x.1 /z 230 4,030 4,060' 4,060 3,465 .3,495 3,495'. 29/6 x 9Y4 to 26 21A6" wide joists use the same hangers as 21/z" wide joists and have the same loads. 3 Yz MIU312j9 ",' - '3'Is ; " 9Y+6 2Yz -_ (16) 0=162 X 3Yz : (2) 0..1 x 11h 230 2 05° ,615 2 820 },980 2;245� 2,-025 X,9 HU210-2 / HUC210-2' ' ✓. 31/8 i 813/t6. 2Yz Max. ;{18) O'.162 x 31h' (10) 0.148 x 3 " ' .,r 5` 2,680 3,020; 3 25012,305 :2,605 2,800'' IBC, 3 117A MIU3.12/11 • - 31/a 11 Y6 21h - (20) 0.162 x 31h (2) 0.148 x 11/z 230 2,880 3,135 3,135 2,475 2,695 2,695 FL, x HU212-2 / HUC212-2 •' ✓ 31/a 109/16 2Yz Max: (22) 0.162 x 314 ' ' ('i0) 0:148 x 3 1,795 3,275 3,695 3,970 2,820 3,180 3,425 to HU325/12"/HUC3.25112 3'/4 113/4 -2%z, :- ,(24} 0162 x 31/z- ; `(12) 0,148 g 3 :� "., ,7..5 3;570 4;030'; 4,335 3 075', 3,470 3,735' -"' 3'IaHUC3.25/16 313%6' - 1 ", h Min, , Max. (28) 0162 z 31/z 4HU3.25/1618 - (12)0.148x3 , 1,515 ',75 2,975 3870 3,360 4,365- 3,610, 4,695 2,560 3,330 2,890 13.755 3,105` 4,040- - 31/.,gbiam HUCO210 2 SDS •'' 3114 '9 3 = (12) Y4".<x 21Iz"SDS (6) Ya" xs21h"SDS :L,3 t5 °,:1n, f#.31,q 1,a1 , 3;fi00 � ?16 3,71 FL HGUS3.25Y10' " ' � 31/4 j " 85A ` 4,' "-; (46) 0.162' 31h (16) 0162'x 3Yz '4,095 9,100 9,100'� 9.100 7825 7,825 7:825 IBC, H5US325f12 3174 105/s 4" - - (56) OA62 x 3Yz - (20) 0.162,x 311/2 ::5,040 9;4„00 9,400: 9,400 $;085 i-8 085 8,085 FL . sLGU3.25 3' a , 8 to 30" ,4Yz = (16) Y4"X 2Yz'' S,DS (12) Y$' X''„21h" SDS :5 555 6720 7,310� %070" 4;$40 5, fi 5,26 i 31h 51/a HHUS46 - 3% 51/a 3 - (14) 0.162 x 31h (6) 0.162 x 31/z 1,320 2,785 3,155 3,405 2,395 2,715 2,930 x HGUS46 - 3% 4346 4 - (20) 0.162 x 31/z (8) 0.162 x 31/z 2,155 4,360 4,885 5,230 3,750 4,200 4,500 HUS48 -)'39l+6 61556 " ' 2 - (6) 0:162 x"3Yz" (6) O.t62 xy3Yz ,1„320 1;595 1,815' 1,960;1365 7,555 1,680' 31h x 7114 HHUS48' '; • -� 35/a 7i/e :' 3 0 -' (22) 6;i62x 3'!z (8) 0.162 x 3Yz; `. 7M0` 4,210 4,770- 5,140 3;615 4,095 4,415 _ HGUS4$ ' -" `=,_ •` • - 351s ! 7:',A6 4 , _ (36)'0r162 x 31/2: (12) 0.162 x 3'h 3,235 °7460 7,460', 7,460_` 6, 15: "6.415 .6,415 IUS3.56/9.5 - 35/e 91/z 2 - (10) 0.148 x 3 - 70 1 1,185 1,345 1,455 1,020 1,160 1,250 MIU3.56/9 • - 39AG 813A6 21/z - (16) 0.162 x 31h (2) 0.148 x 11/z 210 12,305 2,615 2,820 1,980 2,245 2,425 U410 • • • ✓ 3f3/Y6 83/8 2 - (14) 0.162 x 31/z (6)0 .148 x 3 970 2,015 2,285 2,465 1,735 1,965 2,120 HUS410 0 - 39/i6 815/i6 2 - (8) 0.162 x 31/z (8) 0.162 x 31/z 2,990 2,125 2,420 2,615 11,820 2,070 2,240 31/z 9 Yz HHUS410 - 3% 9 3 - (30) 0.162 x 31/z (10) 0.162 x 3Yz 3,565 5,635 6,380 6,445 4,845 5,486 5,545 x HU410/HUC410 ✓ 31N 8% 21/z - (36) 0.162 x 31h (12) 0.162 x 31/z 3,235 7,460 7,460 7,460 6,415 6,415 6,415 HUC0410-SDS - 31A6 9 3 - (12)1/4" x 21/z" SDS (6)114" x 21/z" SDS 2,265 4,500 4,500 4,500 3,24013,240 3,240 HGUS410 • • - 35A 9'A. 4 - (46) 0.162 x 31h (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 7,825 7,825 7,825 IBC, LGU3.63-SDS - 35A 8 to 30 41/z - (16)1/4" x 21/z" SDS (12)1/4" x 21/z" SDS 5,555 6,720 6,720 6,720 14,840 4,840 4,840 LA MGU3.63-SDS - 35/6 91/4 to 30 41/z - (24) Y4" x 21h" SDS (16) Y4" x 21/z" SDS 7,260 9,450 9,450 9,450 16,805 6,805 6,805 tUS3,56Jkf $8 �; - .35N 11'(a ;2 ,- 02) p.148x3 - 0 ,1;420 7,615;' T,745 (:i; 20°"7,390'; 1,485 MIU3.56111 �" "=� 39h6 11 Ya l .2'/z =` (20) 0162 x 3'I: �7 "(2) 014$'x 11/z 210 2,'860 3,135' 3,135) 2,4752,695 2,695' U414 2- - (16j-0162x31/2, - (6).0.148x3; 970 2,305, 2,61512,82011;980 12,245'2,425; ' HHUS410 ' • =° } 36% 9- ' • 3 - {30)"0.162 x 31/z�: `(10) 0.16x 31h %3,SGS 5,635. 6,386 6.44514,845 5,486 5,545< HUS412 = l3'/6 101h 2: " - (10)0 62x 3'h (10) 0.762 z3Yz 13 43 2 660; 3;025 3,265 2,275 2;5901 2,795i 3,1Iz x 71'Ja - HU642 � ,. • • 3e 106 „: _ , - 2,/z Min Max:. (16) 0162 x31h (22) 0162 x 3Yz (6) 01 (10) 0.1480 3 - .',725 1135 2;380 3,275 2688 3,695 3,970 (2,82013,180' ,HU412/ ;2,490+51 3,425' HUCQ412 5DS - 3s/+6 11,)-'^- ` = =(14) Ya'"°X 211i' SDS (6} 1/4° xl1/z" 5DS '2 ct 5 6,{i'37 �,€ 315' 16,0 15l2:630 3.Ei,YL 3,6?G HGUS412 C: ' - '<35/a i 107/116: 4- - (56)6.162 x 3'h (20) 0.162 x 311z '5,040 9,400 9,400,1 9,400 8,085l 8i085' 8,085 LGU3.63 SDS, " • _ _= ,i 3$! j 8 tc 30= 4.1h = (16) Y4''x 2Yz'"SDS (12) Ya' x,21/i' SDS' 5,655 6,70. 6,720'' 6,720 )A 840-j 4;840 (4,840 .. MA'I 14 FQ_Cr1C . . - I'16z ❑t/. f��[1 `Eli.,_ in.n Yin',, nY�".p ti. iYc1 Yi��.,niza bnc."­1. /1111in.cn1'. n ernlo IIr, I nae In ,...r. 46 See footnotes on p.150, Simpson Strong -Tien Wood Construction Connectors Adjustable Truss Hangers �C, This product is preferable to similar connectors because of (a)'easier installation, (b) higher loads, (c) lower installed �j cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table N Finish: Galvanized. Some products available in ZMAX® coating. C See Corrosion Information, pp.13-15. v Installation: m. CUse all specified fasteners; see General Notes. C The following installation methods may be used: U N Top -Flange Installation — The straps must, be field formed over the header — see table for minimum top -flange requirements. F= Install top and face nails according to the table. Top nails shall not be within 1/4" from the edge of the top -flange members. For -- -- the THA29, nails used -for joist attachment must be driven at an d angle so that they penetrate through the corner of the joist and into the header. for all other top -flange installations, straighten the double -shear nailing tabs and install the nails straight into the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, with at least half of the required fasteners in the top half of the header. Not all nail holes in the straps will be filled. Nails must have a minimum.1h" edge distance. Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min.) installation option accommodates conditions where the supported member hangs either partially or entirely below the header. Face-Mount.(Max.) Installation — Install face nails according to the table. Not all nail holes in the"straps will be filled except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift - Lowest face nails must be filled to achieve uplift loads. Options: • .THA hangers available with the header flanges turned in for 35/a" (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart 1314' fnr THAC422 for {22-2 {26.2 Vj THAC422 Face nails Top nails per table per table 13/i typical 21h'for THA422-2 and THA426-2 € o ` c W 21�. U11111THA29 THA418 Double 4x2— 2face nails Use full table value (total) Single 4x2—I 4 top nails See (totaq . nailer table @ ... . r. Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps maybe installed straight or wrapped over with tabulated face nails installed into top and face of head ® Double -Shear Double- Dome Double -Shear Shear Nailing Naifing Side View Side View; Naifing j Do not (Available on Top View bend tab some models) Straighten the double shear nailing tabs and install nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation rypwai 1 nr+ta Top Flange Installation erto tnote 5 p.187 86 THA/THAC . - Adjustable Truss Hangers (cont.) ID These products are available with additional corrosion protection. For more information, see p.15. U M 1. Uplift loads have been increased for earthquake or wind leading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. 3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 1 Yz" min. top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 1'h" nails in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the tniss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried Qoist) member. Based on the installation condition, nails will be installed either straight with straighted double -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 18 Simpson Strong -Tie® Wood Construction Connectors Face -Mount Joist Hangers W 64..... This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost or a combination of these features. The double -shear hanger series, ranging from the fight -capacity LUS hangers to the highest -capacity HGUS mangers, feature innovative clWble-shear nailing that distributes the load through two points on each joist nail for greater strength. This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. ofdesgned fior welded or nailer applications:'--- -- — -- Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart Double -Shear Nailing Top View Double -Shear Nailing Side View Do not bend tab Dome Double -Shear Nailing Side View (Available on some models) 1. for 2x's 1' efor4x's H LUS28 HHUS210-2 P dV "- ---< MUS28 0 gw.41 HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) e LUS/MUS/HUS/HH.US/HGUS .. ................................._..................................................................._......................................................................._.................................................. + Face -Mount Joist Hangers (cont.) a SS" All SS Model Heel" No , �� Height Dimensions (in.): Fasteners" =- Ga = W . _ H B Carrying �= Carded , ;`Member _ .. --,,''Member., Single 2x Sizes ' 18 '': 3i/a 13h 14x3�21% )d.148 x 3 41/4 ' 19Ai <- ""43/a 1 /4 ' ' (4} .1480 3 ° _ "(4) 0:148 MUS26 411Ae 18 1 e/i6 53i6 2 (6) 0.148 x 3 (6) 0.148 x 3 HUS26 45/i6 16 15/6 5% 3 (14) 0.162 x 31/2 (6) 0.162 x 31/2 ;HGUS26 404, 14, " 55/e (20) 0.162 x 31h- - (8) 0162 x 31h " LUSH' (6)D148`.X.3, j �(4)0.148o, MUS28 65/i6 18 i 19AG 61a/i6 2 (8)0.148x3 (8)0.148x3 HUS28 61/2 16 1 % 7 3 (22) 0.162 x 31h (8) 0.162 x 31/2 HGUS28 69A6 12 1 % 71/e 5 (36) 0.162 x 31/2 (12) 0.162 x 31h WS216 ' 41% " 18, ;16 6` 71%6 " 1 Y'4 `"' (8)'0148 x 3 - (4) 0.148 x 3, --- 16 °!, f s/s "< .'9 . 3 "(30) D.162 X 31/z' {10) 6.162 x 31/2" TO6,__ 727,1 15/e '91/e , 5 ' ,(46) 0162'x 31/2;' • (16) 0.162 x"31h' 1. See table below for allowable loads. Single 2z_Siii:s These products are available with additional corrosion protection. For more information, see p.15. For stainless -steel fasteners, see p. 21. Many of these products are approved for installation 6 with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. 1,165 865 1 990 1,070 1 1,355[1,760 935 1;070 1,150 1,475 865 635 725 785 1,000 IBC, FL, 3Vu' 1 295_ „1,486e' .1;560., 1,,560._"1405,:. ;1,560, ; 1;560 1 560 810 955 1;090 1,180 , 35'L'" LA 1,320 2,735 .3,095 3,235 3,235 2,960 3:2,90 3 28;, 3,280 1,150 2,350 2,660 2,780 2,781 575'4,850' 5;170 J 5,390 '4690= 5,220 5;390' ,5390T 7 0 `' ., 3,225 3;610 3,870 3,985' IBC, FL 1,165 1,100 1260 1,350 1,725 1195 1,360 1465 1,730 865 810 925 1,000 1,270 1,326 -1,130 i,b7b ': 2,125 2,255 ' 1875 :.2,135 2 255 2:2 0 t; s0 .. 1,270 1,455 -1,575 1.955 ; BCFL, LA 1,760 4,095 4,095 4,09,5 4,095 4:095 4;095 4,095 4,095 1,480 3,520 3,520 3,520 3,5207275` ..7,275, 7,275 " 7,275 , `i 50<: 7T05 . `7275 , 7275 7,275 ,.1.325' 3,670 3,82(� 3,91'5 : ;4,250" IBC, FL 1,165 1,335 1,530 1,640 2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,500 IBC, FL, 2,635 5,450 5;, 95 5,830 5,830 , 2,635" _ 95, . ' a;;780 . 5 33� 5;330, 2.220 ' ; 320a 2,455 2.535 " 2,825"'' LA 2,090 9,100 910i0 9,100 9,100 2,090 9100 9'00 9,100 9,100 i,5-:5 6,340 6,730 61730 6,730 IBC, FL 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp. 98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45' and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load, • For sloped only or sloped and skewed hangers, the maximum allowable downloads is 0.65 of the table load ' • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing Acute side HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are: p" HGUS Seat Width Joist Down Load Uplift Specify angle W < 2" Square cut 0.62 of table load 0.46 of table load Top View HHUS Hanger W < 2" Bevel out 0.72 of table load 0.46 of table load Skewed Right 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 6dist must be bevel cut) 2".< W < 6" Square cut 0.46 of table load 0.41 of table load All joist nails installed the outside angle (non -acute side). W > 6" Bevel cut 0.85 of table load 0.41 of table load 94 LUS/MUS/HUS/HHUS/HGUS 5S• These products are available with For stainless Many of these products are approved for installation additional corrosion protection. steel fasteners, t with Strong -Drive° SD Connector screws. For more information, see p.15. see p. 21. See pp. 335-337 for more information. Double 2x Sizes HHUS26-2 45/ia 14 35H6 53/a 3 (14) 0.162 x 31/z (6) 0.162 x 31/2 11,3201 2,830 1 3,190 3,415 4,250 1,135 1 2,435 2,745 12,935 13,655 HGUS26-2 4a/I6 . 12 36/i6 57AG 4 (20) 0.162 x 31/2 (8) 0.162 x 31h 12,155 14,340 14,850 5,170 5,575 11,855 13,730 14,170 14,445 14,795 IBC, FL, LA LUS210-2 67/I6 18 31/a 9 2 (8) 0.162 x 31/z 1 (6) 0.162 x 31/2 1,445 1,830 2,075 2,245 2,830 1;245 1,575 1,785 1,930 12,435 HHUS210-2 83/s 14 35/6 87a 3 (30) 0.162 x 31/z (10) 0.162 x 3'/z 3,550 5,705 6,435 6,485 6:485 3,335 4,905 5,340 5,060 5,190 HGUS210-2 8s/,e 12 35h6 93116 4 (46) 0.162 x 3112.(16) 0.162 x 31/z 4,095 9,100 9,100 9,100 9,100 3,520 7,460 7,825 7,825 7,825 Triple 2x Sizes �'.t16UJLb3'�1;4'356,";,1Z 4'--%s,W/2 ,'4,< (ZU)UJbZX3h;_.(tt1U:IbZ�f3Wh e;l=,"4,J4U,,4b3U-'*,II'U" b,J'{b."I;'bo'):d,lJU, 4�.IfU, 14,4,401 4,lyb_IBC,FL, HGUS28=3 616 " 12 41S1r6 711a 4 (36) 0,162 x 3Yi ,'(12) 0:162`x 314 3,235 7460" 7460" 7;41i0 7,960. "2,780", 6,415 6,415' 6,415 6,415 LA HHUS210-3 83/s 14. 411A6 87/a 3 (30) 0.162 x 3'/z (10) 0.162 x 3'h 3,405 5,630 6,375 6,485 6,485' 2,930 4,840 5,485 5,575 5,575 FL HGUS210-3 81 A/ 12 415A6 91/a 4 (46) 0.162 x 31h (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 9,100 3,520 7,825 7,825 7,825 7,825 }iGUS212'3 10 /a ': '1 12°° '4-'ors' 1031a " 4 : '{56) 0.162 x 31h (20) 0.162x 3'h" `5,0�aL;0+v'„-r,C4" 9040 ,5 `5 "�t70, r,I BUG FZf > , u- 16C, F.L, .. LA Quadruple 2x Sizes -rluuibzo`4% (, ,31/ IZ' J'U'A6 I 3Y76 ;' J/UJ,.VJUZX'372 6J,V.110Z X372; C.,)J3 14'0 gW,83U. L,1.,, IIU �aJ'f3,' 13bC13 =3 J6U %'Po.. IBC,FL, HGUS28-4 71/a 12 69A6 I 73A6 1 4 1 (36) 0J62 x 31/z 1 (12) 0.162 x 31/z 13,235 1 7,460 7,460 7,460 7,460. 2,780 1 6,415 16,415 1 6,415 16,415 1 LA HHUS210-4 83/a 14 61/e 87/a 1 3 (30) 0.162 x 31/z (10) 0.162 x 31/z 13,405 15,630 16,37516,485 16,48512,930 14,840 15,485 15,57515,575 FL 4x Sizes IBC, FL, LA IBC, FL LUS48 43/s 18 3s/i6 63/a 1 2 (6) 0.162 x 31/z 1 (4) 0.162 x 31/2 1 '0960 11,315 11,490 11,610 2,030 1 910 11,130 11,280 11,385 11,745 IBC, FL, HUS48 6'/a 14 39AG 7 2 (6) 0.162 x 3'h (6) 0.162 x 31/z 1,320 1,580 1,790 1,930 2,415 1:135 1,360 1,540 1,660 2,075 LA HHUS48 61/2 14 3% 71A 3 (22) 0.162 x 3'/z (8) 0.162 x 3'/2 1,760 4,265 4,810 5,155 5,980 1,515 3,670 4,135 4,435 5,145 HGUS48 67/I6 12 35/a 7'1A6 4 (36) 0.162 x 31/z (12) 0.162 x 3'h 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 HGUS412 10346 1 12 1 35/e 107H6 4 1 (56) 0.162 x 31/2 (20) 0.162 x 31/z 15,605 1 9,045 19,045 19,045 9:045 1 4:900 17,780 1 7,780 17,780 17,780 HGUS414 1171`16 1 12 35/e 127/I64 1 (66) 0.162 x 31h (22) 0.162 x 31/z 5,695 10,125 10,125 10,125 10,125 4,900 1 8,190 18,190 18,190 18,190 Double 4x Sizes IBC, FL, LA FL 1. Uplft loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21/2" nails in the header and 0.162" x 31h" in the joist, with no bad reduction. With single 2x carrying members, use 0.148" x 11/2" nails in the header and 0.148" x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 19 Simpson Strong-TieFl Wood Construction Connectors Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads -(with minimum nailing) apply to heel heights as low as 37/s". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1h" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is'/V per ASTM D1761 and D7147). See technical bulletin T C-HANGERGAP at strongtie.com for more information. Material: 16 gauge fn Finish: Galvanized L Installation: • Use all specified fasteners; see General Notes C• Can be installed filling round holes only, or filling U round and triangle holes for maximum values N • See alternate installation for applications' using the HTU26 on a 2x4 carrying member or it HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity Options. d • HTU. may be skewed up to 671/z°, See Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com. . for installation with Strong -Drive® SD fasteners. i Codes: See p.12 for Code Reference Key Chart Min. heel height per table 6 Many of.these products are approved for installation with Strong -Drive SD Connector screws. See pp. 335-337 for more information. 5tanclard Allowable Loads i. ---- -,._. . 1ai" HTU26 Typical HTU26 Minimum Nailing Installation '-11W max. gap betWeene11d"of' ' truss and carrying member HTU Installation for -Standard Allowable Loads (for 1/2" maximum gap, - use Alternate Allowable Loads.) Maximum Hanger (3ap) Single 2x Sizes q;S a f1'le Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HTU210 similar) ., ,'yam 1mun:1. HTU28 (Min.) v.ec 37/8 , ra 15/a u� 71/is u.ir=:'.SGv/ 31/2 V.tVG.A'WJt, (26) 0.162 x 31h lcvj V.IKYVA 3IG (14) 0.148 x 11/2 1p{JJ.; 1,235 G,.7YV= 3,820 _K"i;ULA+ 3,895 4x)W 3,895 4jlJ_lV-'( 3,895 I,JJJ' 1 1, ;0 ' G,JJU^i 2,865 P, 7i3U 2,920 �5g,.�.:.il�l'J'f."lU.,, 2,920 2,920 IBC, FL, HTU28 (Max.) 71/4 15/a 71As 31/z (26) 0.162 x 31/z (26) 0.148 x 11h 2,020 3,820 4,315 4,655 15,435 1 1,?35 3,285 3,71U 4,005 4,675 LA H"a`'9y5s 0210•(Min) 37/a 15/ 3yh"; ,(32)'0.162X,31/2 "(14);'0.148x1?1h ;1,336, 4,3'0 64,3uJ, ,''CSO';4, �Jv, 1145 3;225,'; 3,225 "^;225 'e225. 6210"(N)ax)', 9%a e"; -1 s/e, 91fie, 31, JWYO.10 Double 2x Sizes HT1J26?2, (Min':) HTU262(MaX:) i ",3?/a,- ', >.51%z ; 35As: 35A6 -571s z57he. 3?/z {20j Od62;x3ih (20)�0.162x31/2 (14) 0148 x„3 ,> (2010:148X3 ;1,515 2175-',2,940 2,940.. ••3,3�0 '3,323":""g a0 - ;3,910 , 0"; 1,305 1,870 " 1,850„'', 2,530",.�,8a5`"3,08i:-3855 " 2,090 i" 2 255� >2,465 HTU28-2 (Min.) 37/a 3-6 71As 31/2 (26) 0.162 x 31/2 (14) 0.148 x 3 1,530 3,820 4,310 4,310 4,310 1,315 2,865 3,235 3,235 3,235 IBC, HTU28-2 (Max.) 71/4 3-As 711/s 31/z (26) 0.162 x 31/2 (26) 6.148 x 3 , 3,485 3,820 4,315 4,655 5:825 2,995 3,285 70 4,U35 FL, LA 1. The maximum hanger gap Is measured between the joist (or truss) end and the carrying member. 2. MinirT um heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1/s" and 1h", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11h" nails in the header and reduce the allowable download to 0.70 of the table.vakie. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. 96 U Z_ Z Z a U F7 C5 Z 0 Z 0 rn 0 0 m 0 U U HTU 6 .................................................................................................................................................................................................................................................................................................................................................................................................................................. Face -Mount Truss Hanger (coot.)- ' 9 Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member vMm Fasteners (in. , DF/SP Allowable Loads SPFJHF Allowati1e Loads Model, No Heel ..,` Height Minimum. Carrying Code Ref.". Carrying Gamed Uplift_ Floor Snow .Roof Wind Uplift Floor Snow Roof Wind Member Member Member `" " (160) " {100} , {115) . {125) "fi¢0) - (16Q) (100j (115) -" , "(125), (160) _.. ; HTU26 (Min.) 37/s (2) 2x4 (10) 0.162 x 31h (14) 0.148 x 11/2 925 1,470 1,660. 1,790 1,875 795 1,265 1,430 1,540 1,615 HTU26 (Max.) 51/2 (2) 2x4 (10) 0.162 x 31/2 (20) 0.148 x 11/2 1,240 1,470 1,66D 1„'• 90 2,220 1065 1,265 1,430 1,540 1,910 IBC, " HTr I9Ft'r0Aar1 "" "�71, . " i �Va "rent n yap Y n,i r�Fi n yes V 1"ii .1.a7n' "5,oan, ` • ,�., x;n n i a anF " `"1 �a>;" 9 Fan ("a"� ` q r"li n . "z zsn ;, FL, LA 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 1h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loads (1/2" Maximum Hanger Gap) moaer `Heel No ;Height AN►; " H 8 Single 2x Sizes Wind (160) HTU26 31h/s 57/a ' 31h ( 24 6.162 k'' '/ ". �) 11 O'148 x 1 �1z . 2;3 5 :2 ;, 9 2,395 040 10 1, 1t1 i, 1 1;5'0 HTU26"{Mrn.} �� 37/a �. '�13A, 5 A4 ' �31/2 (20} 0:162 ><31Iz (14j 0'.148 x 11h :=.1,175 2`940 1 3;100 3106 �" 3,100 ' 1,Q10 1�,955 1,955 1,955 1,955 HTU26 (Max.) - 51h ides, 57/16 31/2 (20) 0.162 x 31Iz .(20) 0148 x 11h,_ 1,215„ 2,9403,"s2E? 31a"80 ' �,630 '' 1,045 7,850 2.0? 2,28'S 2,285 IBC, HTU28 (Min.) 37/a 15/a 7116 31/2 (26) 0.162 x 31/2 (14) 0.148 x 11/2 1,110 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL, LA HTU28 (Max.) 71/4 15/8 7116 31/2 (26) 0.162 x 31/2 (26) 0.148 x 11h 1,920 3,820 4,3i5 4,655 5,015 1,695 2,865 3.235 3,490 3,765 Double 2k Sizes HTU26-2 (Max.); 51h 3 6 .5716 _ 31/2 (24) 0.162 x`�,1/2 "(20 {) k x 3 , ,1,910 ,12;940 (3 =�3,501 3;500 ` 1,645, 2,205^ 2;205 " 2,205 2,205, . HTU28-2 (Min.) 37/a 3-6 7116 31/2 (26) 0.162 x 31/2 (14) 0.148 x 3 11490 3,820 3,980 3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC, FL, HTU28-2 (Max.) 71/4 3�6 7116 31/2 (26) 0.162 x 31/2 (26) 0.148 x 3 3,035 3,820 4,315� 4,655 5,520 2,610 2,865 3,235 3,490 4 40 LA HTU210-2 (Min.).: 37/a ' 3Y16`` 9354 ? 31/2 (32 0.162 x 31/2""(14),0.148 x 3 ';,1,755 4;255 4,255 4,255 , '4;255. ` 1;510 3,190 3,j90- 3,190 3,190 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3: Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating, 5. For hanger gaps between 1/a° and V, use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. Simpson Strong -Tie® Wood Construction Connectors ti z z a 0 Z z 0 CO z 0 a CO CO m 0 0 m 0 U U Medium --Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU'hangers with one flange concealed may be installed similarly. HU and HUC products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension' is 25/16" or greater, at 100% of the table load. Specify HUC. • HU is available with one flange concealed when the W dimension is less than 25/16" at 100% of the table load. Specify as an 'X' version and specify flange to conceal. • For any HU or HUC shown in this catalog, the user may substitute all face nails with 1/4" x 13/4" Titen® 2 screws (Model TTN2-25134H) for concrete and 'A" x 2aN` Titen 2 screws (Model TTN2-25234H) for GFCMU. Follow all' installation instructions and use the loads from the sawn lumber or RNP sections. Material: 14 gauge Finish: Galvanized; ZMAX® and stainless steel available Installation: • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" — Model TTN2-25234H) and for concrete (1/4" x 13/4" — Model TTN2-25134H) are not provided with the hangers. • Drill the 3/1a°-diameter hole to the specified embedment depth plus 1/2". • Afternatively, drill the 3/1s"-diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Titen Installation Tool Kits are available. They include a 3/1e" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/16" x 41/2" drill bit is also available (Model MDB18412). • A minimum edge distance of 11/2" and minimum end distance of 37/3" is required as shown in Figure 1 for fell uplift load. • Wnere no uplift load is requlred, a minimum end distance of 1 1/2" is permitted. Codes: See p.12 for Code Reference Key Chart Concealed flanges HUC410 HU214 Figure 1 — HUC410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 6 23 0 (D 0 0 0 HU/HUC/HSUR/L ................ . ...................... . . . ..................... . . . ... . ........ . . ................... . . .. . ............... . ............. . ..... . ... . .. . .... . .. . . ..... . ..... . .................................... . . . ............. Medium -Duty- Face -Mount Hangers (cont.) 11% ThP_qP. nmrfi intcz nriz. nvniNhIp with iridifinnA mrre)qie)n nmtprtinn Fnr mnrp. infnrmqfinn cap. n 1.1; MbdeV Fasteners Allowable -Loads ( F,/SP GFCMU C rete d Standard ConcreteGFGMU Joist Uplift D' .6010" ,,Down Tit�0'2," ? (10002" 5Y HU26 HU26X (4)1/4 x 2 3/4 (4) 114 x 13/4 (2) 0.148 x 11/2 335 1,000 335 1,545 2 k• 41� A, - , 4 766 HU24-2 HUC24-2 (4)1/4 x 2 3/4 (4) 1/4 x 13/4 (2) 0.148 x 3 380 oOO ,__T_ 1 380 I 1,545 HU26-3 (Min.) . HUC26-3(Min.) (8) 1/4 x 2 3/4 (8) 1/4 x 13/4 1 (4) 0.148 x 3 760 2,600 760 3,200 (12) 114 x 23/4 (12) '/, x 1 -14 1 (6) 0.148 x 3 1,135 3,000 1,135 9 d HU26-3 (Max.) HUC26-3 (Max.) 3,950 I HU210 I HU21OX 1 (8) 1/4 X 2 3/4 1 (8)1/4 x 13/4 1 (4)0.148xll/2 1 545 1 2,000 1 760 1 2,415 1 HU210-3(Min) ..HUC210-3(Min.) (14) 114 x 2 3/4 (14) 1/4 x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210-3 (Max.) HUC210-.3 (Max.) (18) 114 x 2 3/4 (18) 1/4 x 13/4 (10) 0.148 x 3 1,800 4,500 1,800 5,085 HU212 i?XZ 4X 3/W ('1 3/ 77777 A4 �,x111/2, AJ35 2,50 HU212-2 (Min.) HUC212-2 (Min.) (16) 1/4 x 2 3/4 (16) 1/4 x 13/4 (6) 0.148 x 3 1,135 4,000 1,135 4,920 HU212-2 (Max.) HUC212-2 (Max.) (2 2) 1/4 X 2 �/4 (2 2) 114 x 13/4 (10) 0.148 x 3 1,350 5,085 1,350 5,085 -,�U21-2,-3"iMin.'I-�i'�",H,u,C2l2- Win -'�66 1/ /4, 4x2� F,r iddJ�� �,i" "I ;,� -zod", "'T 7135, k '9261�'�"' 4. HU214 HU214)( (12) 1/4 x 2 3/4 1 (12) 1/4 X 11/4 (6) 0.148 x 11/2 1,135 2,665 1,135 1 2,665 (8}HU'C214-ioin ;0 48,x,3 1,5115 '085_ HU214-2.-,(Mak.) "T'(24_ 3 1 114 X 1, 14 048 xi 3' '2,015 ,," HU214-3 (Min.) HU0214-3 (Min.) (18) 114 x 2 3/4 (18) 1/4 X 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 HU214-3 (Max.) HUC214-3 (Max.) (24) 114 x 23/4 (24) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 HU216, 1 1,102 6X -,,(18)1/,4x2 �14 I T 3/' j8� 8 X' 15 15 2,92Q :1 5i5 920 HU216-2 (Min.) HUG216-2 (Min.) (2 0) 114 x 2 3/4 (20) 114 x 13/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUG216-2 (Max.) (2 6) 1/4 x 2 3/4 (2 6) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 2,16r.3 Llb2 (Mi n ny11A *4 0 P 515- 1'51 �6-3(Max.)3 (Max) T 4 4�' x4 �K �'(i-2)'0448 HU7 (Min.) (Not available) (12) 1/4 x 2 3/4 (12) 1/4 x 13/4 (4) 0.148 x 11/2 545 2,980 760 2,980 HU7 (Max.) (Not available) (16) 1/4 x 2 3/4 (16) 1A x 1 3K (8) 0.148 x 11/2 1,085 3,485 1,085 3,485 (Min.} �X� U79' '(M tj�'_6'tg�'A (Not availlablel-', RI '/A'X-23/1 A K, 11 k V if OA4 [ I , � � -_ ' , " , 1, - -_ ",' dqq -1 HU11 (Min.) (Not available) 1 (2 2) 1/4 x 2 3/4 1 (2 2) 1/4 x 13/4 1 (6) 0.148 x 11/2 1 1,135 3,230 1,135 1 3,2_30] HU11 (Max.) (Not available) (3 0) 1A x 2 -/4 1 (3 0) 114 x 1 Y4 I (10)0.148xll/2 1 1,445 3,735 1,445 1 3,735 z C3 a< 2 0 0 F7LU C9 z 0 F CO z 0 CL(n 2 CO c� 38 STAGGER JOINTS - TYP. B/5KI du w� z Lu N UPLIFT/SHEAR ANCHOR-7— EACH TRUSS - SEE B/SKI PLAN NOTE: ADVL FRAMING NOT SHOWN FOR CLARITY RAISED HEEL TRU55 EARINGt A SCALE: NTS SKI I iED HEEL ROOF TRU55E5 PLAN ' r RIBBON BOARD- SEE SCHEDULE FOR SPACING 4 FASTENING TO TRU55ES �'\—MASONRY WALL - SEE PLAN ROOF SHEATHING- GEE I SOFFIT/FASCIA- SEE ARCH. RAISED HEEL ROOF TRU55E5 -SEE PLAN Cie wa r0 RIBBON BOARD- Q < 3 SEE SCHEDULE � U z li FOR SPACING 4 O W w w FASTENING TO w N U is TRUSSES < o = _ Eu L o7. z0m� WALL SHEATHING -SEE PLAN = i MIN. 15/32' CDX PLYWOOD OR C 3 1/16' 055 WITH 8d GUN NAILS U (0.131' X 2 IR') ® 6' O.G. TO UPLIFT/SHEAR GYP. CEILING - RIBBON BOARDS ANCHOR EACH SEE PLAN e m, TRU55- SEE PLAN SCHEDULE DO.NOT FASTEN RIBBON BOARD e INTO END GRAIN OF ROOF TRUSS MASONRY WALL- BOTTOM CHORD SEE PLAN W tlPEVI510N: RAISED HEEL TRUS5 BEARING E3' SCALE: NTS SKI RIBBON 5GHEDULE= DESIGN CRITERIA RIBBON MATERIAL RIBBON SPACING RIBBON ATTACHMENT Vult=1(.5 MPH (2) 12d GUN (0.131' X 3') (Vascmn MPH) 2r4 SPFB2 24' TO EACH TRUSS, (4) EXP. B, ENCLOSED NAILS AT JOINTS Vult=180 MPH (2) 12d GUN (0.131' X 3') (VasdR139 MPH) 2X4 SPF02 16, TO EACH TRU55, (4) EXP. C, ENCLOSED I I NAILS AT JOINTS J d� s SHEETTIRE SHEEP INFOgMATION: JOB NO. ddllld onrerssuEn: Il.oe.ld DR�VM BY: REVIEWFDBY: M SK.1 I ALP E 'OLO'VUIAMY January .10,:2620' Carpenter ,Contractors o-fAm;e'carii J; . nc... 3 60Avg ii 6 01 NW Wiihter.HAV'ori, VL--,3U96-62",Qj� .Dear ' a4- It"has' come to my attention.,"ihatsome questions w. were raJ4pd_ p.pjjcernih95 ;/8,," diameter end trusses t , allow d&f;ico.)'Pf'y02gq a 0- fo;r. ififb"Ad"e'd rods -used ifor o. n g.) Ifthes6.gable-en&are over ron.6W.U.q,os support; --Wit Aredrill �4 ri, ed b-6iit'I-h&,,cene jneofthe ;wj .0 C., ,v, -,C wi bu-: amnag granyconnect6fp t�.otve Face no �',d. �'e..�ffia� th, '' rd , - - - , - - ! - - - - -la, & in, rticdlwQbs ih gn naxep4irjsrequired Ahe truss only supports: 2 feet of floorfdad§4ndha addi iional load.. If you have any, -qu&stidi n, §:)';pIea§6 give,m e:,,a call'.: Sincerely;, Yo 6760rq Forum Orlando, FL 3282.1 W) 5�21-97,90,-�-(,a63)1422-,8085 � _p !Vqj Suite 30.51 www: in il' . -";q'*pQM- T(is domnwthas boon elac rak 3igrtad and weed US1149 a Di4ft StgnetWs. Prillited copir#s witiotA an original signaUo rrvistbe vented using1he o1ginal etecrorucversion. COA f#0 2780 all a No 7086 C.04 'p STATE A ALPINE AN ITW COMPANY J,,sturner Carpenter Contractors of America Job Number. • N334501. ob Dea>ription: ,7A5/320 ,182ECE ,02H ,Rl01 / 1828/CALI/4EBB ELEV.G,E AdGrass___� Joti Eit >rbeertn Criteria ` Design Code:. FBC 7th Ed. 2020 Res IntelliV/EW Version: 20;02.00A JRefk 1X3L89750075 Wind Standard: ASCE 7=16 Wind Speed (mph): 160 Design Loading (pst): 37.00 ,Building Type: Closed This package contains general notes pages, 33 truss drawing(s) and 4 detail(s). 1 069.21.1302.22266 Al 3 06921.1302.22015 A2 5 069,21.1302.22267 A4 7 069.21.1302.21406 _ A6 9 069.2.1.1302.22327 _ A8 11 069.21.1302.21436 A10 13' 069.21.1302.22124 All 15 069.21.1302.23499 A14G 17 06921.1302.21516 A16' 1.9 069.21.1302.22625 C1GE 21 06911.1302.23047 D2 23 069.21.130123000 V8 25 069.21.1302.21766 EJ7 27 069,21.1302.22311 EJ3' 29 069.21.1302.2.1609 CJ3 31 069.21.1302.22577 CJ1A 33 069.21.1302=22843 HJ3 35 GBLLETlNO11;8 37 VALTN 1`60118 Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone:(800)755-6001 www:alpineitw.com E3a3wtr g kutnOer Truss, 2 06911.1302.22812 A1A 4 069.21.1302.21421 A3 6 069.21.1302.21515 A5 8 06921.1302.21827 A7 10 069.21.1302.22218 A9 12 069.21.1302.21875 Al2 14 069.21.1302.21781 A1.3 16 069.21.1302.22421 A15 18 069:21,.1302.23311 61 GE 20 069,21.1302.23155 D1 22 069.21:1302.22468 D3G 24 069.21.1302.22405 V4 26 069,21.1302.23405' ERA 28 069.21.1302.21983 CJ5 30 06921.1302.22407 CJ 1 32 069.21.1302_.21890 HJ7 34 A16015ENG160118 36 VAL180160118 I�r ya Certificate of Product Approval #FL1999 Printed 3/10/2021 1 54:46 PM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted -work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-.es.ora. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) K.ey to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be fond in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.ora. 2.' ICC: International Code Council; www.iccsafe.ora. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4.'TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.orq. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com. Page 3 of 3 SEQN: 249671 / COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T10 / FROM: RWM Qty: 11 7A5/320 ,182EC,E ,02H ,RI01 / 18281CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22266 Truss Label: Al SSB / YK 03/10/2021 12'11"15 19,10" 26'8"1 6'10"8 610"1 6'10"1 = 5X5 E 33'6"9 39,8" 6'10"8 6-17 0 he's^ 39'8" 10' 9'10" 10, 1� 10' 19,101, 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.222 K 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.385 K 999 240 B 1711 !- /- /961 /309 /444 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 J - - H 1711 /- /- /961 /309 /- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.140 J Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: psf B Brg Width = 8.0 Min Req = 2.0 5.2 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.617 H Br Width = 8.0 Min Re 2.0 g q = Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.882 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.457 Members not listed have forces less than 375# Loc, from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1490 - 3155 E - F 1130 - 2029 Top chord: 2x4 SP #2 N; C - D 1366 - 2875 F - G 1366 - 2875 Bot chord: 2x4 SP #1; D - E 1130 -2029 G - H 1490 -3155 Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - L 2759 -1207 K - J 2278 - 858 be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2ff%min.). Restraint material to be supplied L - K 2278 -879 J - H 2759 -1186 and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs L - D 541 -134 K - F 530 -745 for (2) CLR'S where shown. Scab reinforcement to be D - K 530 -745 F - J 541 134 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. �91:£i6fii!tlittJr@ E - K 1530 -745 rr Loading ` y . Truss passed check for 20 psf additional bottom chord �,, `+•,.+•®*^4., °14 live load in areas with 42"-high x 24"-wide clearance..T qt""+oa`g;• '' ram q g: e° Wind s Wind loads based on MWFRS with additional C&C � � '��� Imember design. x Wind loading based on both gable and hip roof types.— o S T 0 • + � ®0•0°o°mramv�°®V . A COA ( 'N � 1a (3/10/2021 "WARNING`* READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r sa�ety to these functions. practices prior performing Installers shall provide bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall attache. rigpid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections temporary have a properly B3, B7 or B10, as appiicab�le. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$cLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOMPAW truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin4of trusses. A drawing seal on this listing this drawing indicates acceptance of professional engc1s�neering responsibility solely -for the design shown. The suitability drawing for any shcture is the responsibility of the Building -Designer per ANSIffPI 1 Sec.2. or cover pa a 6750 Forum Drive and use of this Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2497041 COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T25 / FROM: ALS Qty: 1 7A5/320 ,182EC,E ,02H ,Riot / 1628/CALIMEBB ELEV.C,E DrwNo: 069.21.1302.22812 Truss Label: A1A SSB / WHK 03/10/2021 7'112 12' 17'1"12 19'10" 23'8" 31'8"14 39'8" 7'11"2 414 5'1"12 2'84 3'10" 8'0"14 T11"2 =6X6 F 39'8" 8'1"1 3'9"3 2'112 3' 6'8" 8'0"11 8'1"1 11'10"41 14 r 17' r 23'8" 31'811 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in too Udefl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.386 O 999 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.669 0 706 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.168 K - - Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.314 K Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.791 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.896 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.765 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE. HS IVIEW Lumber Top chord: 2x4 SP #2 N; T1 2x4 SP #1; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; W3,W6,W9,W11 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Plating Notes All plates are 2X4 except as noted. (1) - plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. + Bottom Chord section between vertcials may be removed. ,ORO** Oy rX Qes a o A08 1 p u �W0TI' n m Saio o coA'�l490NA 03/ 10/2021 m 0 he's" 7'11"5 1' 39'8"i ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /961 /309 /444 1 1556 P /- 1961 /309 P Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.2 1 Brg Width = 8.0 Min Req = 2.2 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1410 - 2745 F - G 1410 - 2068 C - D 2144 -4245 G - H 1218 -2103 D - E 1499 - 2794 H -1 1423 - 2777 E -F 1658 - 2771 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2371 -1107 L - K 2402 -1107 Q - M 3738 -1614 K - 1 2406 -1106 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - S 814 -1523 M - F 2007 -1008 C - Q 1476 - 551 M - L 1864 - 604 S - Q 2850 -1327 F - L 492 - 506 Q - D 1271 - 562 L - G 452 - 368 D - M 825 -1539 L - H 475 - 688 **WARNING*" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bragin installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE^ drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOWANY truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional engineenng responsibilittyv solely Tor the design shown. The suitability and use of Phis drawing for any sfructure is the responsibility of the Buildingp esigner per ANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com: TPI: tpinst.ora: SBCA: sbcindustrv.com: ICC: iccsafe.ora: AWC: awc.oro Orlando FL, 32821 SEQN: 249705! HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T9 / FROM: RWM Qty: 1 ,7A5/320 ,182EC,E ,02H ,R101 / 18281CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22015 Truss Label: A2 SSB / WHK 03/10/2021 6'1 "7 12'6'15 i 19' 20'$" 27'1"1 6'5"8 6'S"1 1'8' 6'S"1 �,1 10' 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: ll EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. :5X5=5X5 E F 39'8" 9'10" 19'10" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): 9'10" 29'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.172 L 999 360 VERT(CL): 0.321 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.123 K - Creep Factor: 2.0 Max TC CSI: 0.480 Max BC CSI: 0.747 Max Web CSI: 0.625 03/10/2021 EW Ver: 20.02.00A.1020.20 1 33'6"9 39.8" 6'6"8 6'1"7 10, ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1556 /- A /963 /310 /427 1 1556 A A /963 /310 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 I Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1542 - 2800 F - G 1182 -1779 C - D 1425 - 2521 G - H 1425 - 2521 D - E 1182 -1779 H - 1 1542 - 2800 E - F 1159 -1559 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2444 -1262 L - K 2030 - 937 M - L 2030 - 957 K - 1 2444 -1241 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 508 -119 L - F 548 - 356 D - L 521 - 683 L - G 521 - 683 E - L 548 - 356 G - K 508 -119 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safPety practices prior to performing these functions. Installers shall provide temporary _ bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural -sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Applgy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinQQComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANR COMPAW truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin4 of trusses. A seal on this drawing or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional angsneering responsibility solely -for the design shown. The suitability and use of This drawing for any s9r'ucture is the responsibility of the Building esigner per ANS!/TPI 1 Sec.2. Suite 305 For more information see these web sites_: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustrv.com: ICC: iccsafe.ora: AWC: awc.ora Orlando FL, 32821 SEQN: 249706! HIPS Ply: 1 Job Number: N334501 Cust: R8975 JRef:1X3L89750075 FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DnwNo: 069.21.1302.21421 Truss Label: A3 SSB / WHK 03/10/2021 6'1"7 12'0"15 16'0"1 21'7"15 27'7"1 33'6"9 39'8" 6'1"7 5'11"9 5'11"2 3.7"14 5'11"2 5'11"9 6'1"7 ;5X5 =5X5 E F 39'8" 10' 9.10" 10' 19,10" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 910" 29'8" Defl/CSI Criteria PP Deflection in ]cc Udefl U# VERT(LL): 0.171 L 999 360 VERT(CL): 0.319 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.124 K - Creep Factor: 2.0 Max TC CSI: 0.408 Max BC CSI: 0.748 Max Web CSI: 0.485 Ver: 20.02.00A.1020.20 0011 OH 4 %e s ti b OAR 03/10/2021 10' 1' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- A /965 /312 /407 1 1556 A /- /965 /312 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1608 - 2796 F - G 1252 -1794 C - D 1497 - 2523 G - H 1498 - 2523 D - E 1252 -1794 H - 1 1609 - 2796 E - F 1245 -1635 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2439 -1329 L - K 2064 -1027 M - L 2064 -1048 K - 1 2439 -1308 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D ' 495 -106 L - F 523 - 300 D - L 497 - 674 L - G 497 - 674 E - L 523 - 300 G - K 495 -106 **WARNING"'* READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an c7 SBCA) for safPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSt. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for of lateral restraint of webs shall have bracingq installed per BCSI sections B3, B7 or B10, as applicable. Applly plates to each face o truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the ARMCOWAW truss in conformance with ANSI 1, or for handling, shipping,; mstalla ion and bracin of trusses. A seal on this drawing or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional engineering -responsibility solely or the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer per ANSIITPI 1 Sec.2. Suite 305 I.For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249707 / HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRefAX3L89750075 T8 / FROM: RWM Qty.. 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22267 Truss Label: A4 SSB / WHK 03/10/2021 7'10"14 17' 22'8" 7'10"14 9' 1 "2 5.8" :5X5 5X5 D E 39'8" 31'9" 2 39'8" 9'1"2 + Tl0"14 �1' 10, 9.101. 91101. 10 1 10, 19,10" 29'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L!# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf.' NA Ce: NA VERT(LL): 0.149 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.279 J 999 240 B 1552. /- !- /965 l318 /386 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.060 1 - - G 1552 /- /- /965 /318 /- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.112 1 Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf G Brg Width = 8.0 Min Re 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.760 q = Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.755 Bearings B & G are a rigid surface. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.989 Bearings B & G require a seat plate. Loc. from endwall: not in 9.o0 ft FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1673 -2755 E - F 1699 -2561 C - D 1698 - 2561 F - G 1674 - 2755 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; D - E 1352 -1728 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - K 2393 -1373 J -1 1695 - 842 be equally spaced. Attach with (2) 8d Box or Gun K - J 1695 - 663 1 - G 2393 -1352 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs C - K 498 -448 E - 1 770 -435 for (2) CLR'S where shown. Scab reinforcement to be K - D 770 -435 I - F 498 448 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. �ttt{4tslnrtrrr�yr, Wind Wind loads based on MWFRS with additional C&C e/�®►®�°+�eO°d 0'°°•, rj p'%, member design. Wind loading based on both gable and hip roof types. ` 'a 0 AT 0a. (9�4^tea °�iNn►`a�_`ii�t COA b��,��ONAL ,,.. t� r�@i�sa r34Ses {sass@; 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating; handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for sa�ety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, -top chord shall have proper)% attached structural sheathing and bottom chord shall have a properly attached riccl1id ceiling Locations shown -for permanent lateral restraint of webs shall have bracin installed per SCSI sections B3, B7 or B10, as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. ffefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincQ�Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the *,,,,„,ro,�pN truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawin indicates acceptance of -professional en sneering responsibility solely -for the design shown. The suitability and use of This drawing for any structure is the responsibility of the BuildingVesigner per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineilw.com; TPI: tpinst.org; SBCA: sbcindustry.com• ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 249708 / HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRefAX31-89750075 T24 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21515 Truss Label: A5 SSB ! WHK 03/10/2021 6'1 "7 16'0"1 23'7"15 33'6"9 39'8" 6' 1 "7 9' 10" 10 77"14 91101,10 6'1 "7 :6X6 =6X6 D E T2 12 6 F,—,- T4 M 5X5 5X5 n' C F i m W W1 B G A �a Ht+8-8" =4X6(A2) =5X5 =5X5 -5X5=4X6(A2) 39'8" 10' 9.10" 10 1 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.156 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.292 J 999 240 B 1556 /- A /964 1713 /366 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - G 1556 A A /964 1713 /- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 It HORZ(TL): 0.119 1 Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: psf 5.2 G Br Width = 8.0 Min Re Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.799 9 q = 1.8 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.745 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fee: Yes Max Web CSI: 0.485 Members not listed have forces less than 375# Loc. from endwall: not in 9.o0 It FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp, Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1841 -2852 E - F 1665 -2513 C - D 1665 -2513 F - G 1841 - 2852 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; D - E 1456 -1829 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2505 -1555 J -1 1780 - 954 member design. K - J 1780 -1005 I - G 2505 -1535 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 511 -469 E - 1 617 - 249 K - D 617 - 248 I - F 512 - 469 moist;{tiiftUls{gtt� rr l�frri�Y ` 171' SS • f v r, a g Q. 7'08 1 a RAT 0 ®'s r>aevi®a ftsf67o"1i 111�11111 03/10/2021 •'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "`IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attacheU ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicabgle. Apply plates to each face oT truss and position as shown above and on the Joint9Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCCAIPANY truss in conformance with ANSI/TPI 1, for handling, or shipping,, installation and bracin of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional enUeering responsibility solely -Tor the design shown. The suitability and use of this drawing for any sQr'ucture is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .cam; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249709! HIPS Ply: 1 Job Number: N334501 8975 JRef:1X3L89750075 T7 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CAL1/4EBB ELEV.C,E TDwNF: 069.21.1302.21406 Truss Label: A6 / WHK 03/10/2021 7'10"14 15' 24'8" 31'9"2 398" 7' 1014 7' 1 "2 9'8" 7' 1 "2 7' 10"14 =6X6 =6X6 D T3 E 12 6 F7- 5X5 �5F5 C h W co W1 B G A M H �8,8„ = 4X6(A2) = 5X5 =— 5X5 =5X5 = 4X6(A2) � 39'8" �1' 10' 9'10" 9'10" 10, 10' 19110" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.159 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.298 J 999 240 B 1552 /- A /962 /328 /346 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.061 1 - - G 1552 /- A /962 /328 A EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.115 1 - - Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: psf 5.2 G Br Width = 8.0 Min Re Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.913 9 q = 1.8 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.760 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.474 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1807 -2729 E - F 1827 -2537 C - D 1826 - 2538 F - G 1807 - 2729 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; D - E 1539 -1910 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2363 -1483 J -1 1847 -1110 member design. K - J 1847 -1131 I - G 2363 -1462 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 394 - 358 E - I 628 - 300 K - D 628 - 300 I - F 394 - 358 %aygt44ftPti tflt;tt$trjtf a r ^ 0.708 I ' � o r e r 0 0 o COA# ONA�811"08 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r to safety practices prior performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard Refer to General Notes plate positions. job's page for additional information. ALPINE� AI ine, a division of ITW BuildinccLLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANf COWAW trTss in conformance ANSI/TPI 1, for handling, with or shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional enppmeenng responsibili((�� solely -for the design shown-. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer perANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.orq; AWC: awc.orq Orlando FL, 32821 SEQN: 249710 / HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JR&AX3L89750075 T23 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H .R101 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21827 Truss Label: A7 SSB / WHK 03/10/2021 . 6'1"7 14'0"1 19,10" 25'7"15 336"9 39'8" 6'1"7 7'10"10 5'9"15 5'9"15 7'10"10 6'1"7 - ;5X5 III2X4 =5X5 D E F T2 12 6 ro C 5�5C5 nT4 W3m r` B A H 1 �8 8, =4X6(A2) -5X5 =5X8 =5X5=4X6(A2) 39'8" 10' 9'10" 9.10" 10, 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.176 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.329 E 999 240 B 1556 /- /- /958 l715 /325 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 /- /- /958 f715 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.121 J - - Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.743 H Br Width = 8.0 Min Re 1.8 g q = Load Duration: 1.25 TPI Std: 2014 Max BC CSI: 0.748 MWFRS Parallel Dist: hl2 to h Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.434 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 It FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B-C 1975 -2822 E-F 1780 -2112 C - D 1821 - 2515 F - G 1821 - 2515 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP #1; D - E 1780 -2112 G - H 1975 -2822 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2470 -1666 K - J 1912 -1210 member design. L - K 1912 -1231 J - H 2470 -1645 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 439 - 395 F - J 556 -182 L - D 556 -182 J - G 439 - 395 ygy{iia{{Paitlrtftrtor�/�aA E - K 440 -281 o f P a ID Q. i7G 1 d ® a � t 'tl � 4a 4 a Iftlea 03/10/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition Component Safety Information, of BCSI (Building by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for permanent -lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face oT truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings-160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE� Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOAWA truss in conformance with ANSI/ PI 1, or for handling, shipping,; installation and bracin of trusses. A seal on this drawing or cover pa a listing this drawing indicates acceptance of professional engpeering responsibili��rr solely�or the design shown. The suitability and use ofg is 6750 Forum Drive drawing for any structure is the responsibility of the Building Designer ANSI/TPI 1 Sec.2. Suite 305 per For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249711 / HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T6 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22327 ISSB Truss Label: A8 / WHK 03/10/2021 6'9"4 13' 19,101, 26'8" 32'10"l2 39'8" 4 6'2"12 6'10" 6'10" 6-2"12 6'9"4 :5X5 1112X4 e 5X5 D E F 12 6 2X4 W C /2X4 rr o G Un W3 B A H = 4X6(A2) = 5X5 = SX8 =5X5 = 4X6(A2) 39'8" 9110.. 9110.. 10, 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.191 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.357 E 999 240 B 1556 A A /953 /716 /305 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 /- A /953 f716 /- C Kzt: NAn Des Ld: 37.00 HORZ(TL): 0.121 J Wind reactions based on MWFRS Mea Mea Height: 15.00 ft NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: psf B Brg Width = 8.0 Min Req = 1.8 5.2 Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.543 BCDL: 5.0 psf H Br Width = 8.0 Min Re 1.8 9 q Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.754 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.687 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2014 -2780 E - F 1973 -2289 Top chord: 2x4 SP #2 N; C - D 1925 - 2523 F - G 1925 - 2523 Bot chord: 2x4 SP #1; D - E 1973 - 2289 G - H 2O14 - 2780 Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2421 -1686 K - J 1982 -1323 member design. L - K 1982 -1344 J - H 2421 -1665 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 381 - 339 K - F 425 - 401 L - D 535 -183 F - J 535 -183 ggseftattupal8i/$P� I�rji�f. D - K 425 -401 J - G 381 -339 `.Ja E-K 585 -391 y � aawyra�meroars ro a r m s a r ✓� ens 6. y1 �a V,gTp�N COAL A1. �t ibiD4 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an r7 SBCA) fo'r safety to these functions. practices prior performing Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceilincl Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, _ as applicable. Apply ?fates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. 1�'- ALPINE LL��iill 1 VN Alpine, a division of ITW Buildin$Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the MnWCCWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracinQof trusses. A seal on this drawing or cover pa a listing this drawing indicates acceptance of professional enpineermg-responsibility solely -for the design shown. The suitability and use of ibis 675o Forum Drive drawing for any structure is the responsibility of the Building Designer ANSI/TPI 1 Sec.2. Suite 305 per For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249712 / HIPS Ply: 1 Job Number: N334501 Cust: R8975 JROIX31.89750075 T21 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,Rl01 / 1828/CAL1/4EBB ELEV.C,E DrwNo: 069.21.1302.22218 Truss Label: A9 SSB ! WHK 03110/2021 6'3"4 12'0"1 19,101, 275 334"12 6'3"4 5'8"12 7'9"15 7'9"15 5'812 ,5X5 III2X4 =5X5 D E F 12 T 6 \2C I v_ I ZO W3 Z %:?4 m B 1 A H y� 1 8 8„ 4X6(A2) =5X5 -5X8 -5X5=4X6(A2) 39'B" 10' 9'10" 9'10" 10, 1� 10' 19,10" 29'8" 39'8" Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pt. NA Ce: NA VERT(LL): 0.206 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.385 E 999 240 B 1556 /- /- /947 /717 /284 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.066 J - - H 1556 /- /- /947 /717 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.124 J Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.748 H Br Width = 8.0 Min Re 9 q = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.753 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.999 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2102 - 2791 E - F 2189 - 2492 C - D 1987 -2524 F - G 1987 -2524 Top chord: 2x4 SP #2 N; D - E 2189 -2492 G - H 2103 -2791 Bat chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2434 -1769 K - J 2065 -1444 member design. L - K 2065 -1465 J - H 2434 -1748 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 498 -118 K - F 539 - 531 D - K 539 - 531 F - J 498 -118 yt►fi@Pflt1!!r=t1t tr tr E - K 685 -462 f pr''G ®pia®m0aa•®o t, s` °® 0.7108 1 s ti a P r a o a n p A u COA� 4ian�68i41t' 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! `"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI anc7'SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper!Y attached structural sheathing and bottom chord shall have a properly at ache riqid ceiling Locations shown for Permanent lateral restraint of webs shall have braginct installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and positron as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure truss in conformance ANSI f� PI 1, for handling, to build the AN TV COMG_ANY with or shipping,, installation and bracin4 of trusses. A seal on this drawingor cover pa4e 6750 Forum Drive listing this drawing indicates acceptance of professional encLsneering responsibili((�� solely -for the design shown. The suitabiliy and use of iris drawing for any s9ructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 ,For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN:249713/ HIPS Ply: 1 Job Number: N334501 R8975 JRef:1X3L89750075 T5 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1628/CALI/4EBB ELEV.C,E ]Cust: DrwNo: 069.21.1302.21436 Truss Label: A10 SSB / WHK 03/10/2021 5'919' 28'8" 33'10"12 39'8" 5'9"4 5'2"12 8' 9'8" 5'2"12 5'9"4 ;5X5 =_5XT35 5X5 D F T 12 6 �2X4 W 02X4 o C (a) (a) G Ln in W3 io B 1 A H s 8'8" 1to =4X6 A2 L K J _ ( ) =5X5 r =5X8 =5X5=4X6(A2) 39'8" 9110" 9110" 10, 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.213 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.399 E 999 240 B 1556 /- /- /940 [718 /264 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 J - - H 1556 /- A /940 f718 A EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.127 J - Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.934 H Brg Width = 8.6 Min Req = 1.8 Load Duration: 1.25 TPI Std: 2014 Max BC CSI: 0.752 MWFRS Parallel Dist: h/2 to h Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.751 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: o.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2194 -2804 E - F 2386 -2693 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; C - D 2057 - 2533 F - G 2066 - 2539 D - E 2502 -2773 G - H 2184 -2797 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - L 2448 -1855 K - J 2163 -1578 be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied L - K 2147 -1575 J - H 2440 -1822 and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs L - D 470 -71 K - F 626 -612 for (2) CLR'S where shown. Scab reinforcement to be D - K 739 -778 F - J 466 52 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc.{ryfRtllfti E - K 79 -778 534 trrtttrrrrr Wind Wind loads based MWFRS on with additional C&C member design.�`'��+°c•,�%p Wind loading based on both gable and hip roof types. g o 70$ 1 ' P s ® ° 0 s 03/10/2021 '"WARNING'" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly _ attacheU ri id ceilincl Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicab)e. Apply plates to each face of truss and position as shown above and on the Join f Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$cLComponents Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the ANrtwCO~ truss in -conformance with ANSI/TPI 1, or for handling, shipping,, installation. bracin trusses. A and of seal on this drawin listing this drawing indicates acceptance of professional enggi�neering responsibilitt�y solely -for the design shown. The suitability drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. or cover paWe 675o Forum Drive and use of This Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249714 / HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T4 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21875 Truss Label: Al2 SSB / WHK 03/10/2021 9' 17' 22'8" 30'8" 39'8" 9' g 5 g 8' 9' �6C6 T2 =5XD5 =4E4 T3 =6X6 F T 12 6� T o (a) W (a) u7 p W5 A 1 B G �n I�g,g., 39 H 4X6(A2) =6X6 =6X6 =6X6=4X6(A2) 1 39'8" 10' 9'10" 9'10" 10, 10' 19110" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udef! U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.251 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.469 J 999 240 B 1556 A A /921 /720 /223 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 1 - - G 1556 A /- /921 /720 /- EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.150 I - - Wind reactions based on MWFRS NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TIC CSI: 0.939 G Br Width = 8.0 Min Re 9 q = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.834 Bearings B & G are a rigid surface. Spacing: 24.0 " C&C Dist a: Re Fac: Yes Max Web CSI: 0.306 ft p Bearings B & G require a seat plate. dwa Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2250 -2705 E - F 2239 -2478- Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N; C - D 2238 - 2478 F - G 2250 - 2704 D - E 2906 -3233 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W2,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - K 2330 -1856 J - 1 3176 - 2629 be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied K - J 3174 -2647 I - G 2329 -1835 and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be C - K 718 -428 E - 1 944 -834 same size, species, grade, and 80% length of web K - D 940 - 832 1 - F 718 -430 member. Attach with 0.128x3" gun nails @ 6" oc. 3�trgaetngu#fldadrtf'r Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. a � 0. 7,08 1 G t r m m a s ° o � q 8 A'i 0 m �, O�—� xa 3jy.�L •I"®mOlY m.mf10• e1' VV°VBSP COA 0NAA `�8ar�attttast�t�ti`� 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attache0 rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. - �LPPII NN ALPINE Alpine, a division of ITW Buildingq�Components Group Inc. shall not•be responsible for any deviation from this drawing, any failure truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation bracin trusses. A to build the MN COWA- and of seal on this drawing listing this drawing indicates acceptance of professional en sneering responsibility solely -for the design shown. The suitability drawing for is the -Designer or cover pale 675o Forum Drive and use ofQ is any structure responsibility of the Building per ANSIITPI 1 Sec.2. Suite 305 ,For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.orq; SBCA: sbcindustrv.com: ICC: iccsafe.ora: AWC: awc.ora Orlando FL, 32821 SEON: 249715 / SPEC Ply: 1 Job Number: N334501 Cust: R 9975 JRef:1X3L89750075 T2 / FROM: RWM Oty: 1 ,7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DnvNo: 069.21.1302.22124 Truss Label: A11 SSB / WHK 03/10/2021 5'7"4 5'7"4 10'8" 1L 3 15 16'0"1 23'7"15 5'0"12 7' 1115 4'8"24'8"2 77'14 29'7"15 39'8" il- 6' 10'0"1 5X5 5X5 =4X4 -5X5 =5X5 D F F r u 39'8" 10' 9.10" 9'10" 10 1 10' 19110" 29'8" 39.8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 L 999 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.427 L 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.076 K - - Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft HORZ(TL): 0.142 K - - NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.820 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0,802 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.811 Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): VIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE. 18SS Lumber Top chord: 2x4 SP #2 N; T5 2x4 SP 2400f-2.0E; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /932 1716 /257 1 1556 /- /- /930 /718 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 2225 - 2806 F G 2509 - 2878 C - D 2062 - 2521 G - H 2O44 - 2305 D - E 1917 - 2214 H - 1 2093 - 2649 E - F 1976 - 2258 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2452 -1880 L - K 2805 - 2204 M - L 2814 - 2230 K - I 2266 -1674 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 1699 -1345 G - K 774 - 669 M - E 760 - 872 K - H 693 - 431 M - F 856 - 742 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have Proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for Permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCOWANV truss in conformance with ANSI 1, or for handling, shipping,. installation and bracing of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawing indicates acceptance of professional engineering responsibilitty� sole) or the design shown. The suitabiliCy and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.or Orlando FL, 32821 SEQN: 249716 / COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T20 ! FROM: RWM Qly: 1 ,7A5l320 ,1,2EC,E ,02H ,R,01 / 1828/CALIMEBB ELEV.C,E DrwNo: 069.21.1302.21781 Truss Label: A13 SSB / WHK 03/10/2021 57 4 108 133 1�5 21'7"15 317'15 39'8" 5'7"4 5'0"12 2'7"1 8,4" r 10, 8'0"1 1 I EO 1� Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " =5X5 D 20'8" 10'8" 10'8" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.97 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T3 2x4 SP #1; T4 2x4 SP 2400f-2.OE; Bot chord: 2x4 SP #2 N; B1 2x4 SP #1; Webs: 2x4 SP #3; W7 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 5'8" i 13'4" 5'4" T10" 7'10" 16 23'10" 8' 1' 8 39'"� TT Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or*=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.043 M 999 360 Loc R+ / R- / Rh / Rw / U / RL Lu: NA Cs: NA VERT(CL): 0.080 M 999 240 B 840 /- A /551 . /397 /257 Snow Duration: NA HORZ(LL): 0.017 J - - N* 315 /- /- /159 1140 /- HORZ(TL): 0.028 J H 585 /- /- /436 /242 /- Building Code: Creep Factor: 2.0 Wind reactions based on MWFRS FBC 7th Ed. 2020 Res. Max TC CSI: 0.957 B Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.647 N Brg Width = 68.0 Min Req = - Rep Fac: Yes Max Web CSI: 0.546 H Brg Width = 8.0 Min Req = 1.5 Bearings B, N, & H are a rigid surface. FT/RT:20(0)/10(0) Bearings B, N, & H require a seat plate. Plate Type(s): Members not listed have forces less than 375# WAVE HS VIEW Ver: 20.02.00A.1020.20 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 959 -1265 E - F 645 - 628 C - D 755 - 932 F - G 648 - 471 D-E 808 -911 G-H 324 -611 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 1088 - 733 K - J 924 - 213 M - L 931 - 620 J - H 455 -107 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. tltiilttSlffli9tr+lrrrrrjf D - M 619 ♦� -454 F - K 1390 -1254 fq, rj;, M - E 442 - 299 K - G 854 -1043 �/ ' •ad1A®�°sa�yo f trip E - L 449 -564 s o. 708 1 a • � 4 v 5 , T d ; COA NoON I A 1>"3fPi9"100� 03/10/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and -bracing. Refer to -and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildinnc1�Components Group Inc. shall not -be responsible for any deviation from this drawing, any, failure to build the ANR COMPAW truss in conformance with ANSI PI 1, or for handling, shipping,Installation and bracin4of trusses. A seal on this drawln or cover pa a listing this drawin indicates acceptance of professional enUeering responsibility solely -for the design shown. The suitability and use of This 6750.Fon,m Drive drawing for any structure is the responsibility of the Building Designer per ANSUTPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Odando FL, 32821 SEQN: 249734 / HIPS Ply: 2 Job Number: N334501 8975 JRef:1X3L89750075 T12 / FROM: JRH Qty: 1 7A5/320 ,182EC,E ,02H ,RIO1 / 1828/CALI/4EBB ELEV.C,E FDN.:069.21.1302.23499 Truss Label: A14G WHK 03110/2021 2 Complete Trusses Required 7' 17' 22'8" 3Z8" 39'8" 7' 10, S'8" 10, 7' if 12 =6C6 T2 =8X8 =8X8 =6X6 p T3 E T4 F T 6� T _o fM BLo 7 G 'v i3 A H I�8'8" 4X6(A1) -8X8 =8X8 =-8X8=4X6(A1) 1 1 39'8" �1' 10' 9.10.. 9' 10" 10 1 10' 19'10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.295 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.555 J 850 240 B 3135 /- /- /- /1427 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - G 3136 /- !- /- /1428 A EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.121 1 Wind reactions based on MWFRS Mean Height: 10.51 ft NCBCLL: 0.00 Building Code: Creep Factor: 2.0 B Br g Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf G Br Width = 8.0 Min Re 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.676 g q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.507 Bearings B & G are rigid s Bearings B & li require a seaatt plat late. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: No Max Web CSI: 0.760 Members not listed have forces less than 375# Loc. from endwall: NA FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1424 - 3094 E - F 1534 - 3602 C - D 1533 - 3601 F - G 1425 - 3094 Top chord: 2x4 SP #2 N; T2,T4 2x6 SP SS; D - E 2128 -4831 T3 2x6 SP #2 N; Bot chord: 2x6 SP SS; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Nailnote B - K 2752 -1257 J -1 4769 - 2187 Nail Schedule:0.128"x3" nails K - J 4768 - 2187 1 - G 2753 -1258 Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Maximum Web Forces Per Ply (lbs) Use equal spacing between rows and stagger nails Webs Tens.Comp. Webs Tens. Comp. in each row to avoid splitting. C - K 1287 - 417 E - 1 727 -1297 Loading K - D 727 -1298 1 - F 1287 -417 #1 hip supports 7-0-0 jacks with no webs. tglttitltittuoitt/Drr�r Wind Wind loads and reactions based on MWFRS. a�,` ®,®a°°WQB+°`°•b'`��r�,, ° `.% I Wind loading based on both gable and hip roof types. 3' �„. i o. 708 1 ° r ° ® a y a S ® b� p b `JY b 4� p®mewmim �yyi ` COA At. i. f"fig 1t61l1{S 03/10/2021 `"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted -otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. �LPP �I NN ALPINE Alpine, a division of ITW Buildinc� Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCCWV truss in conformance with ANSI 1, or for handling, shipping,, installation bracin trusses. A this drawing and of seal on or cover page 675o Forum Drive listing this drawin indicates acceptance of professional en ineenng responsibility solely or the design shown. The suitability and use of This drawing for any sfructure is the responsibility of the BuildingUesigner per ANSI/T I 1 Sec.2. Suite 305 For more information see these web sites: Alpine: aI ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249717 / COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T19 / FROM: RWM Qly: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22421 Truss Label: A15 SSB / WHK 03/10/2021 5'7"4 10'8" 15'3"15 23'3"15 5'7"4 5,0"12 T 47"15 '} 8' = 5X5 D 12 T 6 � o�2X4 =5X74 =H0510 C E T3 F 60 B A � =3X6(A1) N =5X8 =5X5 M =4X6 21' 5' — 5' 5' 8 16' 21' 26' =4X4 31'8"l 3T8" 39'8" 8'4"2 11 r.15 7' _5X70(SRS) T T4 G H TT� o :v J 11 �88 5X5 = 3X6(A1) 13'8" 5'8" 8' 31'8 3918" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.038 0 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.072 0 999 240 B 745 /- /- /497 /341 /276 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.017 K - - M 1429 /- /- /726 /654 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.031 K L 629 /- /- /238 /218 !- NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: .psf Building Code: Creep Factor: 2.0 1 534 /- /- /399 1245 A Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.701 Wind reactions based on MWFRS Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.635 B Brg Width = 8.0 Min Req = 1.5 M Brg Width = 8.0 Min Req = 2.0 Spacing: 24.0 " C&C Dist a: 3.97 ft Re Fac: Yes p Max Web CSI: 0.703 L Brg Width = 8.0 Min Req = 1.5 Loc. from endwall: Any FT/RT:20(0)/10(0) 1 Brg Width = 8.0 Min Req = 1.5 GCpi: 0.18 Plate Type(s): Bearings B, M, L, & I are a rigid surface. Wind Duration: 1.60 WAVE HS VIEW Ver: 20.02.00A.1020.20 Bearings B, M. L, & I require a seat plate. Lumber Members not listed have forces less than 375# Top chord: 2x4 SP #2 N; T3,T4 2x4 SP #1; Maximum Top Chord Forces Per Ply (Ibs) Bot chord: 2x4 SP #2 N; Chords Tens.Comp. Chords Tens. Comp. Webs: 2x4 SP #3; B - C 1109 -1100 E - F 800 - 732 Bracing C - D 1003 - 901 G - H 766 - 618 (a) 1X4 #3SRB or better continuous lateral restraint to D - E 835 -674 H - 1 595 -577 be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied Maximum Bot Chord Forces Per Ply (Ibs) and attached at both ends to a suitable support by Chords Tens.Comp. Chords Tens. Comp. erection contractor. (a) or scab reinforcement may be used in lieu of CLR B - O - 410 -442 M - L restraint. substitute (1) scab for (1) CLR and (2) scabs 570 O - N 570 -442 L - K 530 367 530 367 for (2) CLR'S where shown. Scab reinforcement to be N - M 598 -426 K - 1 451 -326 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" dc.gtt;g4tt9tf!Pi4f/�l Maximum Web Forces Per Ply (Ibs) Wind }� J_fl Webs Tens.Comp. Webs Tens. Comp. Wind loads based on MWFRS with additional C&C member design. ti aaop°i ••°p ���� q� �' � � � " � 'y C - 0 502 -291 M - F 909 -732 O - D 469 -387 L - G 947 -898 Wind loading based on both gable and hip roof types. t: ® e6 E - M 1635 -1574 p • A Too 1� COA b AIONA te a•• 03/10/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per-BGSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a -properly attached rigpid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable.. _App�y plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the ANR CCWV truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawing indicates acceptance of professional engineering responsibility solely or the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249718 / SPEC Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T18 / FROM: RWM Qty: 1 , A5/320 ,182EC,E ,02H ,R101 / 1828/CALI/4EB8 ELEV.C,E DrwNo: 069.21.1302.21516 Truss Label: A16 SSB / WHK 03/10/2021 ' 5'74 10'8" 17'3"15 23'6" 29'8"1 32'8" 39'8" 5'7"4 5'0"12 6'7"15 662"1 6'2"1 2'11"1 7' 19'3"15 • _5X5 �(TY T6 —12 5L5 T O m =8X8 -8X8 =5X10(SRS T rN E F G H I J K m B 1 AB AE G � M xcT A N 1 Y 3X6(A1) =5X5 X W =_5X5 V u T S R O P =_4X6 1112X4(.2 -44 O =5X5 =3X6(A1) 21' 5' 13'8" 1'3"15 5 T 5 �- 1 8' 'i'1''i 8' 16. 17' "15 26' 29,6"5-1 1 2V 31' � Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.037 Y 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.069 Y 999 240 B 774 A /- /508 /355 /317 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.016 0 - - U 1323 /- /- /633 /586 A EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.030 0 R 711 /- /- /257 /237 /- Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 M 531 /- A /381 /247 1- Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.948 Wind reactions based on MWFRS Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.636 B Brg Width = 8.0 Min Req = 1.5 U Brg Width = 8.0 Min Req = 1.8 Spacing: 24.0 " C&C Dist a: 3.97 ft Re Fac: Yes p Max Web CSI: 0.584 R Brg Width = 8.0 Min Req = 1.5 Loc. from endwall: Any FT/RT:20(0)/10(0) M Brg Width = 8.0 Min Req = 1.5 GCpi: 0.18 Plate Type(s): Bearings B, U, R, & M are a rigid surface. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Bearings B, U, R. & M require a seat plate. Lumber Members not listed have forces less than 375# Top chord: 2x4 SP #2 N; Maximum Top Chord Forces Per Ply (Ibs) Bat chord: 2x4 SP #2 N; Chords Tens.Comp. Chords Tens. Comp. Webs: 2x4 SP #3; B-C 1118 -1151 F-G 823 -776 Plating Notes C - D 1027 -960 G - H 834 -791 All plates are 2X4 except as noted. D - E 791 -722 K - L 681 - 548E - F 823 -777 L - M 628 - 571 (*') 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Maximum Bot Chord Forces Per PI Ibs Chords Tens.Comp. Chords Tens. Comp. Wind B-Y 978 -830 T-S 585 -491 Wind loads based on MWFRS with additional C&C Y - X 627 -411 S - R 584 -491 member design. X - W 462 -350 R - Q 424 -356 Wind loading based on both gable and hip roof types. W - V 462 -350 Q - P 424 -355 tltgttiftlut;triltl V - U 462 -350 P - O 424 - 356 U - T 589 -490 O - M 445 - 354 } 6 , Maximum Web Forces Per Ply (Ibs) f Webs Tens.Comp. Webs Tens. Comp. m p� ®. Q8 1 C - Y Y D 445 -257 U -AB 611 - 605 - 453 -285 AB- H 504 -522 ® . f o u E - Z Z - U 1516 -1447 1536 -1466 R -AE AE- K 930 910 - 847 - 826 o is 8p o � 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping; installing and bracing.Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)y attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face otruss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANR COWAW truss in conformance with ANSI 1, or for handling, shipping,, Installatlon and bracin of trusses. A seal on this drawinp or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional en Ineenng responsibilitty�r solely -for the design -shown. The suitability and use of this drawing for any structure is the responsibility of the BuildingI esigner per ANSUTPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249739 / GABL Ply: 1 Job Number: N334501 Cust: R 8975 JRef1X3L89750075 T3 / FROM: HMT Qty: 1 7A5/320 ,182EC,E ,02H ,Rl01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.23311 Truss Label: 131GE �SSB / WHK 03/10/2021 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 pif at 22.33 BC: From 20 pif at 0.00 to 20 pif at 21.33 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS All 6015ENG160118 & GBLLETIN0118 for gable wind bracing and other requirements. - any as dra Alp tru: listi dra For 10'8" 10'8" (TVP) =4X4 F 21'4" 21'4" 21'4" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): 21'4" 10'8" Defl/CSI Criteria ♦ Maximum Reactions (ibs), or*=PLF PP Deflection in loc L/defl U# Gravity Non -Gravity VERT(LL): 0.005 R 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.011 R 999 240 B* 125 /- /- /39 /48 /11 HORZ(LL): 0.004 L - - Wind reactions based on MWFRS HORZ(TL): 0.006 R B Brg Width = 256 Min Req = - Creep Factor: 2.0 Bearing B is a rigid surface. Max TC CSI: 0.323 Members not listed have forces less than 375# Max BC CSI: 0.197 Max Web CSI: 0.091 EW Ver: 20.02.00A.1020.20 0 a 0.7'08 1 0 y @Jp �mae„ra�®*P r 10%t � W119"itttl 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, by TPI an fabricating, fo'r safety practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly tl ri4id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, icable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to Is 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. a division of ITW Buildingq�Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4 of trusses. A seal on this drawingor cover pa e us drawing indicates acceptance of professional engineering responsibilittyy,solely-for the design shown. The suitabiliy and use of this for any structure is the responsibility of the Building esigner per ANSI/TPI 1 Sec.2. information see these web sites: Alpine: alpineilw com• TPI: tpinst orq; SBCA: sbcindustrycom; ICC: iccsafe orq• AWC: awc orq AL NE AN RW COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:249737/ GABL Ply: 1 Job Number: N334501 Cust:R8975 JRefAX31.89750075 T1 / FROM: RWM Qty: 1 7A51320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22625 Truss Label: C1GE �SSB / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SIP #2 N; Webs: 2x4 SIP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 plf at 15.00 BC: From 20 pif at 0.00 to 20 plf at 14.00 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS Al6015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. T T 5' 2' -- (TYP) =4X4 D 14' 14' 14' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/l 0(0) Plate Type(s): 14' 7' DefI/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.007 J 999 360 VERT(CL): 0.014 J 999 240 HORZ(LL): -0.004 H - - HORZ(TL): 0.009 H Creep Factor: 2.0 Max TC CSI: 0.392 Max BC CSI: 0.242 Max Web CSI: 0.142 ♦Maximum Reactions (Ibs), or*=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B* 129 /- /- /40 /50 /12 Wind reactions based on MWFRS B Brg Width = 168 Min Req = - Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. C - D 376 -199 D - E 377 -199 VIEW Ver: 20.02.o0A.1020.20 I Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 511 -403 H - E 511 -403 0- ,08 1 e ^1 COA 03/10/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping,- installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)% attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buiidin Components Group Inc. shall not,be responsible for any deviation from this drawing, any, failure to build the truss in conformance with ANSI f� PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa4e 6750 Forum Drive listing this drawing indicates acceptance of professional ancLsneering responsibility solely or the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSVTPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.orq: SBCA: sbcindustrv.com: ICC: iccsafe.ora, AWC, awa.oro Orlando FL, 32821 SEQN: 249721 / COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 FROM: JRH Qty: 1 , A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.23155 Truss Label: D1 KD / WHK 03/10/2021 T M o_ N 14 5' 5' =4X4 C 10, 5' 12 6 M B D q E 88 F 2X4(A1) III2X4 - 2X4(A1) 5' 5' 10, Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA Des Ld: 37.00 EXP: C Kzt: NA NCBCLL: 10.00 Mean Height: 15.00 It Building Code: TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAX/C Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 5 10, Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udell U# Gravity Non -Gravity VERT(LL): 0.007 F 999 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.013 F 999 240 B 434 /- A /286 /202 /134 HORZ(LL): 0.003 F - - D 434 /- /- /286 /202 /- HORZ(TL): 0.006 F Wind reactions based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.345 D Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.257 Bearings B & D are a rigid surface. Max Web CSI: 0.081 Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.02.00A.1020.20 B - C 522 -494 C - D 521 -494 �Q rt'�� tl,y9/�A/tlpa� 4.FE r 0. i�i a 1rdArS�ii14�1l�iN COA�PtZqONAL 03/10/2021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 396 - 293 F - D 396 - 293 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigqid ceilingp Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI actions B3, B7 or B10, _ as applicable. Apply plates to each face otruss and position as shown above and on the Join Details, unless noted otherwise. F�efer to ALPINE� drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the AMMCOMPAW truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4g of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional en ineenng responsibilitty�r solely for the design shown. The suitabilify and use of leis drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcinduslry.com; ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 249722 / COMN Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T14 / FROM: JRH Qly: 1 7A5/320 ,182EC,E ,02H ,R101 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.23047 Truss Label: D2 KD / WHK 03/10/2021 5' 5' =4X4 C 10, 5' 12 6 u� io q B D E 88 F 2X4(A1) 1112X4=2X4(A1) Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types 10' 5' 5' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): 5' 10, Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.007 F 999 360 VERT(CL): 0.013 F 999 240 HORZ(LL): 0.003 F - - HORZ(TL): 0.006 F - Creep Factor: 2.0 Max TC CSI: 0.345 Max BC CSI: 0.257 Max Web CSI: 0.081 Ve r: 20.02.00A.1020.20 s }• r �a��yy ST®«a®aow,ry«\e4j'p®®«��lg�iPy� a.708 1 « s S P,i 0 $• . co 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 434 /- /- /286 1202 /134 D 434 /- /- /286 /202 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 522 - 494 C - D 521 - 494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 396 - 293 F - D 396 - 293 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r sa ety practices nor to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigctid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joinf9Details, unless noted otherwise. Flefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the RNM�CWG truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawin or cover pa a 675o Forum Drive listing -this drawing indicates acceptance of professional engiineering responsibilitty� solely -for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2497351 HIPS Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T17 / FROM: JRH Qty: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22468 Truss Label: D3G KD / WHK 03/10/2021 T _o 43 12 3' 7' 10, 3' 4' 3' 4X6 C 4X6 D 6T B E 4LJ F 8 8 H G 1112X4 1112X4 2X4(A1) = 2X4(A1) 1 3'1"12 3'1"12 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -1.00 to 56 plf at 3.00 TC: From 28 plf at 3.00 to 28 plf at 7.00 TC: From 56 plf at 7.00 to 56 plf at 11.00 BC: From 20 plf at 0.00 to 20 plf at 3.03 BC: From 10 plf at 3.03 to 10 plf at 6.97 BC: From 20 plf at 6.97 to 20 plf at 10.00 TC: 129 lb Conc. Load at 3.03, 6.97 TC: 65 lb Conc. Load at 5.00 BC: 80 lb Conc. Load at 3.03, 6.97 BC: 52 lb Conc. Load at 5.00 Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. 10, 3'8"8 6' 10"4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): 3112 10, 1 Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.022 H 999 360 VERT(CL): 0.044 H 999 240 HORZ(LL): 0.008 C - - HORZ(TL): 0.016 C Creep Factor: 2.0 Max TC CSI: 0.288 Max BC CSI: 0.365 Max Web CSI: 0.059 03/10/2021 EW Ver: 20.02.00A.1020.20 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 625 /- /- /- /316 A E 625 /- /- A /316 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 E Brg Width = 8.0 Min Req = 1.5 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 467 - 962 D - E 467 - 962 C - D 389 - 842 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 829 - 394 G - E 829 - 394 H - G 842 - 389 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)y attached structural sheathing and bottom chord shall have a properly attached rigpid ceilin Locations shown for -permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, _ as applicable. Applgy plates to each face of truss and position as shown above and on the Join �Details, --unless noted otherwise. Defer to ALPINE� drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANr COMFA truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawin indicates acceptance of professional en sneering responsibilit�yr solely -for the design shown. The suitability and use of this drawing for any s r'ucture is the responsibility of the Building -Designer per ANSI[TPl 1 Sec.2, Suite 305 - For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249723 / VAL Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T33 FROM: RWM Qty: 1 7A5/320 ,l82EC,E ,02H ,RI01 / 1828/CALIAEBB ELEV.C,E DrwNo: 069.21.1302.23000 Truss Label: VS KD ! WHK 03/10/2021 3'11"8 7'11" 311 "8 1 3' 11 "8 12 =4Xg4 6 T N=4X4(D1)=4X4(D1) 1 A C � �9'6"3 D Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 SDacina: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others. 7'11" 7'11" 7'11" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.028 999 360 VERT(CL): 0.051 999 240 HORZ(LL): -0.010 - - HORZ(TL): 0.019 Creep Factor: 2.0 Max TC CSI: 0.321 Max BC CSI: 0.374 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 a y/� ,q • ® v � g ° e ° t �g .. COA> AL 03/10/2021 ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D' 75 /- /- /35 /26 /8 Wind reactions based on MWFRS D Brg Width = 95.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 506 - 366 B - C 503 - 366 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - C 330 - 393 ""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme.care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI.,Unless noted otherwise, top chord shall have propery attached structural sheathing and bottom chord shall have a properly attacheTri id ce!lin Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10, as applical5 e. App�y plates to each face, of truss and position as shown above and on the Joint Details, unless noted otherwise. Ifefer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional encLsneering responsibili(t�� solely -for the design shown. The suitability and use of this — drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249724 / VAL Ply: 1 Job Number: N334501 Cust: R 8975 lRef lX31-89750075 T16 / FROM: RWM Qly: 1 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22405 Truss Label: V4 KID / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Scacina: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others. 1'11"8 1 3'11" 1'11 "8 1111,18 12 6 =4X4 B A 4X4(D1)=4X4(D1) C 10'6"3 D 3'11" 3'11" 3'11" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in ]cc Udefl U# VERT(LL): 0.004 999 360 VERT(CL): 0.007 999 240 HORZ(LL): -0.001 - - HORZ(TL): 0.003 Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.098 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 $�Fy°$ •¢/yam" ��l �`�\���y�l °bp�Po�A0D 8qq ��drl- '`��' •��� fit:,° °{�� `� s0. S a 0 s � ° . q*°oquoa°gs 03/10/2021 ♦ Maximum Reactions (lbs), or *=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL D* 75 /- /- /32 /18 /6 Wind reactions based on MWFRS D Brg Width = 47.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigpid ceiling Locations shown for ermanent lateral restraint of webs shall have bracing installed per.BCSI sections B3, B7 or B10, _ as applicable. Apply Oates to each face oFtruss and position as shown above and on the Joint Details, unless noted otherwise. Defer to ALPINE -� drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. �LPPII NN Alpine, a division of ITW Buildin Components Group Inc. shall not: be responsible for any deviation from this drawing, any failure to build the ANMCCWAW truss in conformance with ANSIi9 PI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawing or cover pa4e 6750 Forum Drive listing this drawing indicates acceptance :of professional engineering responsibility solely -for the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer per ANSIITPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249725 / EJAC Ply: 1 Job Number: N334501 Cust: R 8975 JROAX3L89750075 T15 / FROM: RWM city: 8 ,7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DnvNo: 069.21.1302.21766 Truss Label: EJ7 SSB / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T 1 � 7' 7' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): C Deft/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.015 D HORZ(TL): 0.028 D - Creep Factor: 2.0 Max TC CSI: 0.720 Max BC CSI: 0.507 Max Web CSI: 0.000 EW Ver: 20.02.00A.1020.20 y�r e4resee�ne � ,���i r® C •• r e ' o.708 9 e � a • v e t¢S S r d Q �. COA Sq,4! 0N A L Wmnsol ; 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 331 /- /- /249 /108 /208 D 125 A A /73 /- A C 174 /- A /128 /169 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for Permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face oF.truss and position as shown above and on the Join 9Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinQQComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the n Cowa truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracingq of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawing indicates -acceptance of professional en sneering responsibilit solely for the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building�esigner perANSIRI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineilw.com; TPI: tpinst.orq: SBCA: sbcindustrv.com: ICC: iccsafe.oro: AWC: awc-orn Orlando FL, 32821 SEQN: 249726 EJAC Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T11 / FROM: LPM Qty: 6 , A5/320 ,182EC,E ,02H ,R101 / 1828/CALIAEBB ELEV.C,E DrwNo: 069.21.1302.23405 Truss Label: EJ7A �JB / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T 2X4(A1) Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 7' 7' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fee: Yes FT/RT:20(0)/l 0(0) Plate Type(s): Defl/CSI Criteria PP Deflection in ]cc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.016 C HORZ(TL): 0.030 C Creep Factor: 2.0 Max TC CSI: 0.738 Max BC CSI: 0.513 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 °�R• H. a ' QUO t O. s COArij${ 03/10/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A 270 /- /- /179 f71 /186 C 126 A /- /76 /- _ A B 177 /- A /132 /171 A Wind reactions based on MWFRS A Brg Width = 8.0 Min Req = 1.5 C Brg Width =1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracirip installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCQWP truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawingg or cover pa a 675o Forum Drive listing this -drawing indicates acceptance of professional enccLLmeering responsibili(t�� solely -for the design shown. The suitabiliCy and -use of This drawing for any structure is the responsibility of the Building -Designer per ANSYT_Pl 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEON: 249727 / EJAC Ply: 1 Job Number: N334501 Cust: R 8975 JRef:lX3L89750075 T28 / FROM: JRH Qty: 3 7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22311 Truss Label: EJ3 SSB / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 4"3 V Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. I 21 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): C T cM O Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D - HORZ(TL): 0.002 D - Creep Factor: 2.0 Max TC CSI: 0.248 Max BC CSI: 0.112 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 10'2"11 LO C'7 N 8-8" ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 188 A /- /157 /71 /100 D 52 /- /- /28 A A C 65 /- /- /45 /66 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ./.. NN a e e s 0. 708 1 - ' a s o �P 009 fib®tl11CC�'®mom` . COA f j � +NA��`�4; jt�i9t;$1154�f� 03/10/2021 '*WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply to each face of truss and as shown the Join 9Details, Refer Oates position above and on unless noted otherwise. to drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawin or cover pa a listing this drawing indicates acceptance -for AN—CO-AW 6750 Forum Drive of professional engineering responsibility solely the design shown. The suitability and use of This drawing for any structure is the responsibility of the Building -Designer perANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEON: 249728 / JACK Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T35 FROM: LPM Qty: 4 ,7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21983 Truss Label: CJ5 KD / YK 03/10/2021 Loading Criteria (psf) TOLL: ' 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 11'2"5 12 6 M a) tT N iM M B �+'� A 8'8" D Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 4'11"4 411 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.005 D - HORZ(TL): 0.010 D - Creep Factor: 2.0 Max TC CSI: 0.549 Max BC CSI: 0.257 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 ..dooeoo a'. j�srr�t o s �D a 0.7.08 . 9 a D a, S 0 D8 a s o' d®o �C A in COA #' (J6.8 ���• 03/10/2021 ♦Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 256 /- /- /200 /88 /152 D 89 !- /- /51 /- /- C 118 /- /- /85 /116 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have �roper)y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face, oT truss and position as shown above and on the Join Details, _.unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildingg Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI PI 1, or for handling, shipping,, installation and bracin4 of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates�acceptance of professional en ineenng responsibility solely -for the design shown. The suitability and use of )his drawing for any structure is the responsibility of the Buildinggesigner per ANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249729 / JACK Ply: 1 Job Number: N334501 Cust R 8975 JRef:1X3Las750o75 T34 I FROM: LPM Qty: 4 , A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21609 Truss Label: CJ3 �SSB / WHK 03/10/2021 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: . 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Soacina: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 2X4(A1) Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 2' 11 "4 2' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): C T Defl/CSI Criteria PP Deflection in loc Udell UA VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D HORZ(TL): 0.(101 D Creep Factor: 2.0 Max TC CSI: 0.234 Max BC CSI: 0.105 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 o a 0 s COA ONA� tt 'rrersuwnatoli 03/10/2021 ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 185 A /- /156 /71 /9f - D 50 /- A /27 A /- - C 63 A /- /44 /64 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING*" READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted otherwise, top.chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attachec�ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. as applicable. Apply plates to each face, oT truss and position as shown above and on the Joint9Details, unless noted otherwise. ffefer to A 10111116111111, LPI N E drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin44� Components Group Inc -shall not. be respponsible for any deviation from this drawing, any failure to build the wMCOWAIN truss in conformance with ANSI/TPI 1, or for handling,- shipping,, installation. and bracin of trusses. A seal on this drawin or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional enVeering responsibility solely -for the design shown. The suitabilif9y and use of This - drawing for any structure is the responsibility of the Building�esigner per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249730 / JACK Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T32 / FROM: LPM Qly: 4 ,7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALI/4EBB ELEV.C,E DrwNo; 069.21.1302.22407 Truss Label: CA KD / WHK 03/10/2021 43 T t 12 6 C 11114 i 11'r4 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl Uh TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): NA BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): -0.000 D Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.000 D Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.183 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.022 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.000 Loc. from endwall. Any FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord 21 r 1 9'2"5 ': ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 143 /- /- /145 f76 /45 D 11 /-2 /- /14 /10 /- C - /-15 /- /29 /33 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# COA iTf7,taenal�a�� 03/10/2021 ' **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted -otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown for permanent lateral restraint of webs shall _have.braciriinstalled per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCONNANY truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawing indicates acceptance of professional enAsneering responsibility solely or the design shown. The suitability and use Nis drawing for any structure is the responsibility of the Buildings esigner per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: alpineitw.com: TPI: toinst.ora: SBCA: sbcindustrv.com: ICC: iccsafe.orn• AWC:• nwr. orn Orlando FL, 32821 SEQN: 249731 / JACK Ply: 1 Job Number: N334501 Cust: R 8975 JRefAX3L89750075 T27 I FROM: LPM Qty: 4 7A5/320 ,182EC,E ,02H ,R101 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.22577 Truss Label: CJ1A KD / WHK 03/10/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 4 3 V E 12 6 C 11114 11114 iF M Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/4 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA Enclosure: Closed Lu: NA Cs: NA VERT(CL): NA Risk Category: II Snow Duration: NA HORZ(LL): -0.000 D - EXP: C Kzt: NA HORZ(TL): 0.000 D - Mean Height: 15.00 ft Building Code: Creep Factor: 2.0 BCDL: 4.psf BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.183 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.022 C&C Dist a: 3 00 ft Rep Fac: Yes Max Web CSI: 0.000 Loc. from endwall: Any FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAXIF: VIEW Ver: 20.02.00A.1020.20 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. @®g ° 4 Q �. 708 1 m � �T 4 kd�pIN7t1yY it"I41 03/10/2021 "WARNING"` READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT * FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care Component Safety Informatior bracing per-BCSI. Unless note attached rigid ceilinct Location as applicab-le. Apply plates tc drawings 16OA-Z for standard Alpine, a division of ITW_BuildincLComponents Group Inc. shall 9'2"5 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /145 f76 ME D 11 /-2 - /- /14 /10 /- C - /-15 /- /29 /33 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# not be responsible for any deviation from this drawing, any failure to build the g,, installation and bracing of trusses. A seal on this drawing or cover pa4a Bring responsibili��r solely -tor the design shown. The suitability -and use of This ;ignerper ANSI/TPI 1 Sec.2. ALPINE MMOOWAW 6750 Forum Drive Suite 305 Orlando FL, 32821 jorawing for any more information see these web sites: Alpine: alpineitw.com: TPI: SEON: 249732 / HIP_ Ply:1 Job Number: N334501 Cust: R 8975 JRef:1X3LB9750075 T26 / FROM: HMT city: 2 , A5/320 ,182EC,E ,02H ,R101 / 1828/CALI/4EBB ELEV.C,E DrwNo: 069.21.1302.21890 Truss Label: HJ7 KD / WHK 03110/2021 5'3"5 5'3"5 9'10"1 4'6" 11 E 12'2"3 12 4.24 a 2X4 C v j�) M v B T 4"3 A 8 8 FE 2X4(A1) =4X4 V5" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA D Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 0.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 It Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP 2400f-2.OE; Webs: 2x4 SP #3; Loading Hipjack supports 6-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. (3) 16d common (0. 1 62"x3.5") nails at top chord (3) 16d common (0. 1 62"x3.5") nails at bottom chord 9'2"2 9'2"2 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.040 F 999 360 VERT(CL): 0.076 F 999 240 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 326 /- /- /- /154 A HORZ(LL): 0.010 C - - E 364 A /0 /- /84 /0 HORZ(TL): 0.018 C - - D 214 A /- P /177 A Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.546 B Brg Width = 10.6 Min Req = 1.5 Max BC CSI: 0.416 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.260 D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# VIEW Ver: 20.02.00A.1020.20 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 394 - 562 H h� �I aeo�f OYo m® e 0. 7,08 1 / ° SWAT COA ONAL ��,'�v�` Lawl"Ssatct4Bt1 03/10/2021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - F 531 - 358 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 394 - 583 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for (permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. as applicable. Apply plates to each face o truss and position as shown above and on the Join, Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to jobs General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCO +v truss in conformance with ANSI1TPI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawingor cover pa a 675o Forum Drive listing this drawing indicates acceptance oFprofessional anQineenng responsibility solely -for the design shown. The suitabiliy and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249733 / HIP_ Ply: 1 Job Number: N334501 Cust: R 8975 JRef:1X3L89750075 T29 / FROM: JRH Qty: 2 ,7A5/320 ,182EC,E ,02H ,RI01 / 1828/CALIAEBB ELEV.C,E DrwNo: 069.21.1302.22843 Truss Label: HJ3 �SSB / WHK 03/10/2021 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld. 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 17 2X4(A1) I — VY Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 0.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Loading Hipjack supports 2-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 4'2"3 4'2"3 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): C Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.120 Max BC CSI: 0.074 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 03/10/2021 10'2"6 C\1 prpn ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 84 /- A /- /45 A D 28 /- A /7 A /- C 64 /- /- /- /48 /- Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Applgy plates to each face of truss and position as shown above and on the Joini Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not.be responsible for any deviation from this drawing, any, failure to build the ANRWCOWAW truss in conformance with ANSI 1, or for handling, shipping,, Installation -and bracinct of trusses. A seal on this drawmg or cover page 675o Forum Drive listing this drawing indicates acceptance of professional an Ineenng responsibility solely -for the design shown. The su!tabiliCy and use of this drawing for any structure is the responsibility of the BuildingUesigner per ANSI/TP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 Gable Stud Reinforcement Detail ASCE 7-161 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.Q0 Or: 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1,00 ❑ri 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or, 120 moh Wind Sma & 15' Moan Hoinh+_ Pnr+Intl„ Pv,r-1--4 n v-+ - t nn (7 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) 1x4 'L' Brace w (1) 2x4 'L' Brace w (2) 2x4 'L' Brace ww (1) 2x6 'L' Brace w (2) 2x6 'L' Brace ■ Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B #1 / #2 3' 10, 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' U S P I; #3 3' 8' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' HF Stud 3' 8' 5' 9' 6' 1' 7' 8' 7' 11' 9' 1' 9' 6' 12' 0' 12' 6' 14' 0' 14' 0' p Standard 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' 11' 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' #1 4' 0' 6' 8' 6' 11' 7' 10' 8' 2' 9' 4' 9' 8' 12' 4' 12' 9' 14' 0' 14' 0' S P #2 3' 10' 6' 7' 6' 1V 7' 9' 8' 1' 9' 3' 9' 7' 12, 2' 12' 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' d F Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U _ #1 / #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' 4-) - S P F #3 4' 2' 7' 1' 7' 9' B' 9' 9' 1' 10' 5' 10' 10' 13' 9' 14' 0' 14' 0' 14' 0' U I I P Stud 4' 2' 7' 1' 7' 6' 8' 9' 9' 1' 10' 5' 10, 10' 13' 9' 14' 0' 14' 0' 14' 0' QJ 0 HI Standard 4' 2' 6' 1' 6' 5' 8' 1' 8' S. 10' 5' 10, 10' 12, 8' 13' 7' 14' 0' 14' 0' \ #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10, 8' ill 1' 14' 0' 14' 0' 14' 0' 14' 0' / S P #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13, 11' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10, 8' 6' 9' 1' 10' 6' 10' 11' 13' 4' 14' 0' 14' 0' 14' 0' Q3 D F L Stud 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10' 11' 13' 4' 14' 0' 14' V 14' 0' Standard 4' 2' S' 8' 6' 0' 7' 6' 8' 0' 10, 2' 10, 10' ill 10' 12' 7' 14' 0' 14' 0' 0 #1 / #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 10' 7' 12' V 14' 0' 14' 0' 14' 0' 14' 0' d S P F #3 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' LD U H F Stud 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' ill 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' 0 �l Standard 4' 7' 7' 0' 7' 5' 9' 4' 10' V 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 1' 8' 5' 8' 8' 9' ill 10' 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 9' 7' 4' 7' 10, 9' 8' 10, 1' 11' 7' 12' 0' 14' .--I D F L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 14' 0' 0' Diagonal brace option, vertical length may be doubled when diagonal brace Is used. Connect diagonal brace for 60014 at each end. Max web total length is 14'. Vertical length shown In table above. at AN ITW COi 11514% Earth\ City\ Expressway \ 1 Suite%242 \ 1 Earth\ City,%MO\ 63045 Aboutj� 87 18' L 'L' Brace End Zones, typ. 2x6 DF-L #2 or better diagonal r bracer single 8, or double cut (as shown) at upper end. `l1t W` Refer to chart Sk —VARNM" READ AND FDLLTIV ALL N=S a THIS IIRAVING! w DWMTANTww Fl1RMSH THIS DRAWING T13 ALL CONTRACT�(S RXLUDM THE INSTALLERS; Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Ref ®t; Ito. the latest edition of BCSI (BuRding Component Safety Information, by TPI and SBCA) fo s, actices prior to performing these functions, Installers shall provide temporary bradng pe. B less noted otherwise, top chord shall have properly attached structural sheathing and bo 1 all have a properly attached rigid celling. Locations shown for permanent lateral restraint I all have bradng Installed per BCSI sections B3, B7 or H10, as applicable. Apply plates to en truss and position as shown above and on the Joint Details, unless noted otherwise. fer to drawings 160A-Z for standard plate positions. I Ine, a division of ITV Building Components Group Inc shall not be responsible for any devlatl Is drawing, any fallure to build the truss in conformance with ANSI/TPI 1, or for handling, ship) tallation & bracing of trusses. A seal on this drawing or cover page llsti g this drawing, Imdicates acceptance of professional glneering responsBnRity solely for the design shown. The suitability and use of this drawing r any structure Is the responsibility of the WAd4ng Designer per ANSI/TPI 1 Sec2, For more Information see this Job's general notes page and these web sites, UE Bracing Group Species and Gradest Group At Spruce -Pine -Fir Hem -Fir #1 / #2 IStandarEd #2 1 Stud #3 1 Stud 1 #3 Stnndnrd Dou Las Fir -Larch Southern Plnewww #3 #3 Stud Stud Standard Stnndnrd Group BI Hem -Fir #1 & Btr #1 Do" Ins Flr-Larch Southern Plnewww #1 1 1 #1 #2 1 1 #2 lx4 Braces shall be SRB (Stress -Rated Board). wwFor Ix4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group B values may be used with these grades, L,able I russ Betail Notes: Wind Load deflection criterion Is L/240. Provide uplift connections for 75 plf over continuous bearing (5 psf TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with 10d (0.128'x3.0' min) nails, ill For (1) 'L' brace, space nails at 2' o.c, In 18' end zones and 4' o.c. between zones. )K)KFor (2) 'L' braces, space nails at 3' o,c, In 18' end zones and 6' o.c, between zones. 'L' bracing must be a minimum of 80X of web member length. Gable Vertical Plate Sizes Vertical Len th No Splice Less than 4' 0' 2X3 Greater than 4' 0', but 3X4 gJfll less than 11' 6' Greater than 11' 6' 4X4 f f/ir II + Refer to common truss design for u r<j peak, splice, and heel plates, +: °+ Refer to the Building Designer for conditions ve ti° lei th, not addressed by this detail. REF ASCE7-16-GAB16015 DATE 01/26/2018 �� DRWG A16015ENC160118 ° ��+., MAX, TOT, LD, 60 PSF _ 111110 7/10/2021 !E� MAX, SPACING 24,0' 'T' Reinforcing Member Gable Truss Gable Detail Fnr I Pt -in \/Prtir-n I cz Gable Truss Plate Sizes pproprlate Alpine gable detall for :e sizes for vertical studs, Engineered truss design for peak, rb, and heel plates. vertical plates overlap, use a ite that covers the total area of Lapped plates to span the web, e, 2X4 2X4 r2X8 Provide connections for uplift specified on the engineered truss design, Attach each 'T' reinforcing member with End Driven NoAsi 10d Common (0,148'x 3,',min) Nails at 4' o.c. plus (4) nails In the top and bottom chords. Toenalled Nails, 10d Common <0,148'x3',min) Toenails at 4' o.c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 8 ASCE 7-16 Gable Detail Drawings A11515ENC100118, A12015ENC100118, A14015ENCI00118, A16015ENC100118, A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118, A11530ENC100118, A12030ENC100118, A14030ENC100118, A16030ENC100118, A18030ENC100118, A20030ENC100118, A20030END100118, A2003OPED100118, S11515ENC100118, S12015ENC100118, S14015ENC100118, S16015ENC100118, S18015ENC100118, S20015ENC100118, S20015E�NDIOOII S11530ENC100118, S12030ENC100118, S14030ENC ®d3pp01001 01 S18030ENC100118, S20030ENC100118, S20030pQ110 [ See appropriate Alpine gable detail for max] eJglc�y 9,odgr44j 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe-nall - Or - End-nall To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical Length Is 14' from -top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member. eb Length Increase w/ °T' Brace Example- ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1,00 Gable Vertical = 24'o,c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 30% = 1,30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8 ' 7 ' = 11 ' 2 ' 'T' Relnf, Mbr, Size 'T' Increase 2x4 30 2x6 20 Eeb pi I&P IAN ITW COMPANY 115141 Earthl City\Expressway IISuite\242 %%Earth% City,l MO163045 VINGI "30HPO2TANT" FVURR11QSH nrtS REM TAND O °ALL ALL NOTES � M im INSIALLER1 Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Ref m n follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo s t practices prior to performing these functions. Installers shall provide temporary bradng pe. BLSL a Unless noted otherwise, top chord shall have properly attached structural sheathing nntl bo m cho shot[ have a property attached rigid ceiling, Locations shown for permanent lateral restraint f s shall have bracing Installed per BCSI sections E3, B7 or B10, as applicable. Apply plates to et. of truss and position as shown above and on the Joint Detalls, unless noted otherwise. f Refer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc shall not be responsible for any devintlo %r this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shippin Installation 6 bracing of trusses, A seal on this drawing or cover page UstI g this drawing. kxkates acceptance of professbnal engineering responsibility sotety for the design shown. The suitaMty and use of this drowlrg for any strucU" Is the respons"ty of the RuAding Designer per ANSI/TPI 1 SecZ For more Information see this Job's general notes page and these web sitesr ALPINE, www.alpineitw,comi TPIr www,tpinstorgi SBCAi www.sbclndustry,orgi ICG wwwlccsafearg ,i v 0 �p+ o 4 Al 0 c a �0 • "V r eaew• , se•e , ewab.ewew {� 114, ` Q7�H�TPiI�E7 /10/2021 �l9 ffi114g MAX, TOT, LD, 60 PSF REF LET -IN VERT DATE O1/02/2018 DRWG GBLLETIN0118 DUR, FAC, ANY MAX, SPACING 24,0' Valley Detail - ASCE 7-16: 180 mph, 30' Mean Height, Partially Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N ,or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, �� Attach each valley to every supporting truss withi 535# connection or with (1) Simpson H2,5A or equivalent connector for ASCE 7-16 180 mph. 30' Mean Height, Part. Enc. Building, Exp. C, Wind TC DL=5 psf, Kzt = 1.00 ❑r ASCE 7-16 160 mph. 30' Mean Height, Part. Enc, Building, Exp. D, Wind TC ,DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown. Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members. All plates shown are Alpine Wave Plates 3X4 12 12 Max. � 2X4 X4 i8-0-0 max WI 4X4 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing. Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, BOY length of web, same species and grade or better, attached with 1Od box (0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with) properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. Valle Spacing Pitched Cut Bottom Chord Valley X4 TYf G a i�tls � SQ EEy9 _ey r Square Cut Bottom Chord Vallev 2X4 4X4 _��Tf Stubbed Valley Optional. Hip End Detail Joint Detail H. s,,bommon T ..VARNMM REAR NO Pn_LaV ALL MOTES CH nUS BRAVB4Cd �. �(Ijt3 4 ■wWWTANTa FURNISH THIS DRAVIM M ALL CWTRACTDRS UCLUDING THE BNSTaLLER& Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refera follow the latest edition of HCSI (BuRding Component Safety Information, by TPI and SBCA) fort-'! R practices prior to performing these functions. Installers shall provide temporary bracing perLUnless noted otherwise, top chord shall have properly attached structural shed#Ong and bolt 11shall have a properly attached rigid celling. Locations shown for permonent lateral restraint • i�i V t shall have bracing Installed per BCSI sections B3, B7 or HIO, as appllcdble. Apply plates to e.9 n t1 m [� of truss and position as shown above and an the Joint Details, unless noted otherwise. Q, i • �'N 2 eRl Refer to drawings 160A-Z for standard plate positions. ®s• f 44 rd� `yam. Alpine, a division of ITV Building Components Group Inc shall not he responsible for any deviation m ••wr i yy® \i- this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, erw�r ws•` ` �* AN ITW COMPANY Installation 6 bracing of trusses. A seal on this drawing or cover page listing this drawing, indicates acceptance of professional !tl v 1 �( 11 1151A Earth\ City\ Expressway englneering responsibitIty solely for the design sham The sultahalty and use of this drawnng ^ INVAL 11 SuRe\242 for day structure Is the responswalty of the Building De,lgrner per ANSI/TPI I Sec.& � t� ha+ 3/10/2021 \\Earth\CityA MO\63045 For more Information see this Job's general notes page and these web sites, ALPINE www.alpineltw.conr TPb www.tpinstorgl SBCA, www.sbclndustry.org) ICG wwdccsafearg E-LL 30 30 C DL 20 15 C DL 10 10 C LL 0 0 ❑T, LD, 60 55 m 24' Partial Framing Plan �OPSF REF VALLEY DETAIL 7 PSF DATE 01/26/2018 0 PSF DRWG VAL180160118 0 PSF i7PSF DUR.FAC.1.25/ 1,3311.1511.1 SPACING 24.0' Valley Detail - ASCE 71-16: 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better. Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, 34Attach each valley to every supporting truss with: (2) 16d box (0,135' x 3,5') nails toe -nailed for ASCE 7-16, 30' Mean Height, Enclosed Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00, Max, Wind Speed based on supporting truss material at connection location: 170 mph for SP (G = 0.55, min.), 155 mph for DF-L (G = 0.50, min,), or 120 mph for HF & SPF (G = 0.42, min.), Maximum top chord pitch is 10/12 for supporting trusses below valley trusses. Bottom chord of valley trusses may be square or pitched cut as shown. Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are Alpine Wave Plates, 3X4 12 12 Max, I 2X4 X4 �- 8-0-0 Max 4X4 12 12 Max. I 1X3 LX3 (Max Spacing) 3 5X4/SPL fl- 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing. Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80Y length of web, same species and grade or better, attached with 10d box (0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with: properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c. or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, WWA Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0', 2X4 Valle Spacing Pitched Cut Square Cut Stubbed Valley Bottom Chord Bottom Chord End Detail Valley Valle ToeyA I C o mz +N1-1, ll S t 10 Ma 42X4nraitraeof,,�j aa.w.,. ommon Trusses ``gag 0. N f 'r at 2 ' o,c. 4X4 Optional Hip Joint Detail n T-usses 2 o, c. — Partial Framing Plan w VA131DXiww READ An FM, m`" ALL NOTES CN THIS WAVMG V m ®. rU0 4 L TCLL 30 30 40 PSF REF VALLEY DETAIL ■IDPMUNTwa FURMSH TIES DRAWING TO ALL CONMCT13RS INCLUDING THE INSTALLIIt� Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Re aril c TC DL 20 15 7 PSF DATE 01/26/2018 fallow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) a ,* practices prior to performing these functions, Installers shall provide temporary bradng BCSLw e Unless noted otherwise, top chord shall have properly attached structural sheathing and b on a d p^� py a BC DL 10 10 10 PSF DRWG VALTN160118 shall have a properly attached rlgld ceiling. Locations shown for permanent lateral restrain of P'11 4J • shall have bracing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to e%,�,h ebs s 4, of truss and position as shown above and on the Joint Details, unless noted otherwise. • Y 'h BC LL 0 0 0 PSF .4 RI Refer to drawings 160A-Z for standard plate positions. Alpine, i division of ITV build Components Group Inc, shall not SI responsible for any deviati � TOT, LD, 60 55 57PSF this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shlppt sew,rewwa �7 AN IT W COMPANY Installation & bracing of trusses. \ \ 514\ Eai1h\ Ci 1 Expressway A seal on this drawing or cover page Usti g this drawing, Indkates acceptance of professbnal t �j ty p y engineering responsUlty solely for the design shorn The sWtnblllty arw use of this drawing 4 j kb� ��N4 /10/2021 DUR.FAC.1,25/1,33 1,15 1.15 \1Suile\242 for any structure k the responsibility of the BuAd4g Designer per ANSI/iPI 1 Set:2. 814P1}91i \l Earth\City,\MO\63045 For more Information see this Job's general notes page and these web sites SPACING 24,0' ALPINE, wwwalpineitr.comi TPI, www.tpinst.orgi SECA, wwwsbclndustry.orgi ICO—1—afe.org ; a VALLEY FRAMING & BRACING DETAIL Y R BC 1/2 of Lumber Size and Grade•Minumum Requirements GENERAL NOTES Purlins required 2%0" O.C. in absence of plywood sheathing. Trusses without sheathing applied must he evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this is Impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2.5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'-0" or less -Maximum valley height: 14'-0" -Maximum mean roof height: 30 feet -ASCE 7.05, 140 mph, Enclosed, Cat 11, Exp B,1=1.0, Kzt=1.0 -Or A Maximum of ASCE 7-10,180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max. :e the crippes for each row starting from the valleys or sleepers working inward to the ridge board so that cripple locations are gored between rows. ITYP) innection Requirement Notes 2x6 rafters to ridge 416d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 416d toe -nails (**) 816d face -nails Rafter to sleeper or blocking 5 16d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 3 16d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails . Ridge board to truss 416d toe -nails Purlin to (Typ) 3 16d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 3 16d toe -nails l �V "4V1 "` hr ""r13. Collar beam to rafter 416d toe -nails CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0" to 10'-0" long nailed w/ 2 -10d (0.148"x3") nails. Or 2x4 "T' or scab reinforcement nailed to flat edge of cri�ple with 10d f0.128"x3.0") nails at 6" o.c. "T' or scab must be 90 % of cripple length. Cripp es over 10'-0' long requre two CLR's or both faces w/ " V or scab. Use stress graded lumber & box or common nails. ,Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are Installed Into ridge board -Install blocking under rafter if sleepers are not used. -Install blocking under cripples If cripples fall between lower truss top chords and lateral bracing Is not used. -Apply all nailing In accordance to current NOS requiremen �tf Nails are common wire nails unless noted otherwise. Hr EHIS'••., / y' ZAWDU 0-aW rANra F TM WPM M ANO °Vu"COMM"aTES ON AAMURSS 7CLUBM TW IWTNJzxs ; * LL 20 30 40 54 REF VALLEY FRAMING Trusses requb a extreme care ti fabricatine, tnrrs6he, shlppine, kwtalune and braclne. � Refer to DL 10 20 7 7 DATE 10/O1/14 folloe the latest edition of SCSI ChAdIne Component Safety Informtlon, by TPI and S.M for saf • ^C • praetices Prior to perfornhhe these functbrhs. Installers shall provide tenparag brodne per B STATE �./� 6 = limes. noted othereise, tap chord shall have properly attached str..Ih—t sheathlnp and bottom • ,p sham have a property attached rpid eeLVO locations shorn for pernonent tateral restraint of • . 4. JFC DL 0 0 0 0 DRWG VACNV1801015 d r7 �^ (I� oft have and poe Installed per 11=above sand on tin 17 or Det s, applkobte. Apply plates to each faQl' : • lu(�\`I(1 of taus and posttlan as siwn above and on the Idnt DetnRs, vdess iwced otherwise. $ •: �1 P..' `l(♦�' C LL 0 0 0 0 Refer to drawings 16DA-2 for xft lard plate positions. �i • • �1 Alpine, a aMslon of ITV "ding Conponents Group me shaU not be responsible for arty deviation fran ^r ••••��' ••••• � QC` /1N iTLVQOMAAN1 this d -.U, any fazu-e to btAd the truss In confornance with ANSI/M 1, or far hamm�e, stippbe ♦ c TOT. LD.30 50 47 61 Installation f, bra�ddnroe�o�f trusses. n �+ G A�herrr�;or cover pace Uslingdesb ttds da.thp, at� acceptance �� ujOrYQ`-lot �� DUR. FAC. 1.25/1.15 solely for atheoe shin d The 13389 Lakefront Drive far arty Ie rrsporrcibllty of tid3hp Leslprrr per ArtSI/rPi 1 Sec'-' Earth My, M063008 For more iattecotlon see vials job's eenrral notes po�try�V Ieemd�fearp 9Z ZO�r— SPACING SEE ABOVE ALPIIFi mat YInforn ti TPL eethh, ob's C .n. ehre