Loading...
HomeMy WebLinkAboutAPPROVED, TSP114074 MATHELIN JAMES MPU SUPLEMENTAL 02 17 2022PV STRING INVERTER #1 PV DISCONNECT NEW ELECTRIC METER NOR T H PROPERTY LINEPROPERTY LINEPROPERTY LINE PROPERTY LINE SERVICE DETAIL E-1 1 1 ONE - LINE DIAGRAM A VICINITY MAP N.T.S. KEY NOTES 1.EXISTING 2"C FOR SECONDARY CABLES 2.REFER TO GROUNDING DETAIL 3.CIRCUIT BREAKERS SHALL BE LISTED AS "SERVICE DISCONNECT, SUITABLE FOR USE AS SERVICE EQUIPMENT". 4.EXISTING 3/4"C WITH (3) - #6 CU., (1) - #6 CU. GND. SCOPE OF WORK NEW 200-AMP VERTICAL METER COMBO TO REPLACE EXISTING STAND ALONE METER 150A 120/240V. GENERAL NOTES ALL WORK TO BE PERFORMED IN ACCORDANCE WITH 2017 NEC, THE 2018 IRC, 2018 IRC, UTILITY ESRM AND ALL APPLICABLE LOCAL CODES, ORDNANCES AND AMENDMENTS. AVAILABLE SHORT CIRCUIT = 22,000 AMPS PER SRP TABLES 2P-200A 1 PV:2P-40A 43 N G 2 NEW EXISTING N.T.S. "PROPERTY SIDE FACING STREET" METER TO SRP UTILITY TRANSFORMER OF 3 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE:PARCEL NUMBER: PROJECT ID: DOCUMENT CONTROL ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC DATE CAD QC MATHELIN JAMES 02-11-2022 191 NE CAPONA AVE PORT ST LUCIE FL 34983 3419-530-0225-000-6 TSP114074 02-01-22 JH NT 1 MPU SUPPLEMENTAL ADDED1 02-14-22 AV NT #6 CU. BOND TO INTERSYSTEM BONDING ROUND BAR #1/0 CU. BOND TO EQUIPMENT ENCLOSURE PER 2017 NEC 250-102(D) #2 CU. BOND TO METAL PIPING (GAS, SPRINKLER, PNEUMATIC PER 2017 NEC 250-104(B) #1/0 CU. BOND TO METAL UNDERGROUND WATER PIPE PER 2017 NEC 250-52(A)(1) #1/0 CU. MAIN BONDING JUMPER PER 2017 NEC 250-28(D) #4 CU. GROUNDING CONDUCTOR TO CONCRETE ENCASE ELECTRODE (UFER) PER 2017 NEC 250-66(B) #1/0 CU. BOND TO METAL FRAME OF BUILDING PER 2017 NEC 250-52(A)(2) 6' MIN #2 CU. GROUNDING ELECTRODE CONDUCTOR TO GROUND ROD PROVIDE AN EXOTHERMIC CONNECTION TO THE ROD #6 CU. GROUNDING ELECTRODE CONDUCTOR PER 2017 NEC 250-66(A) PROVIDE ADDITIONAL GROUND ROD(S) AS REQUIRED BY 2017 NEC 250-53(A)(2) 3/4" X 10' LONG GROUND ROD, 8' MINIMUM SHALL BE IN DIRECT CONTACT WITH THE EARTH 200A GROUNDING DETAIL - MAIN SERVICE NO SCALE GROUNDING DETAIL E-2 2 OF 3 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE:PARCEL NUMBER: PROJECT ID: DOCUMENT CONTROL ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC DATE CAD QC MATHELIN JAMES 02-11-2022 191 NE CAPONA AVE PORT ST LUCIE FL 34983 3419-530-0225-000-6 TSP114074 02-01-22 JH NT Residential Standard Calculation 9/25/97 by: John Sokolik STEP 1 Article 220.42 & 220.52 2553 Version 2011 L General Lighting load 2 1 Small Appliance Laundry circuit Gen.Lgt, Sm App.& Laun. Load 7,659 VA 3,000 VA 1,500 VA 12,159 VA 3,000 VA @ 100%= 9,159 VA @ 35% = VA @ 25% = STEP 2 Article 220.50 & 220.51 A/C Condenser & Fixed Electric Space Heating 7,130 VA AHU 1 VA VA VA VA STEP 3 Article 220.53 1 1 1 1 1 1 AHU 2 AHU 3 AHU 4 AHU 5 Water Heater Freezer Refrigerator Dishwasher Disposal Microwave R / Hood Microwave Mini Refrig Wine Clr Insta Hot Ironing Center Jacuzzi Tub Sprinkler Pump Well Pump Fountain Pump Elevator Pool Equip. Panel QTY 5,800 VA VA VA VA VA 4,500 VA 1,400 VA VA 1,030 VA 1,587 VA 400 VA 1,630 VA VA VA VA VA VA VA VA VA VA VA VA VA VA STEP 4 Article 220.54 Electric Clothes Dryers STEP 5 Article 220.55 Electric Ranges or Number of appliances Check Box for Gas Range Cooktop Cooktop Oven(s) Oven(s) Number of appliances Col B demand Col B demand Col B demand Col B demand 0 Dem. Factor Cooktop & Oven Demand Load 0% W jmp1jds@comcast.net >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Pool Panel Feeder Calculation Continuous Motors Non-continuous Spa heater 11 kVA Pool heater 3.5 ton Pool heater Pool Light Blower other load other load 5 ton 2333 Min.Copper Pool Feeder Minimum Panel Rating (See Note) 0 . . . . . . 0 . . . . . . . . . . . . . . . . . . . . . . . . 0 . . . . . . 0 240v 0 0 240v 240v AWG A A 0 0 0 0 0 0 0 0 0 A Phase Amperes B 0 0 0 0 0 0 0 0 0 A A Neut. load N Continuous 0 Motors 0 0 0 0 0 240v 240v 240v 240v 240v 0.0 Max.Unbalanced Neutral Load Non-continuous Motors 240v 240v 240v 240v 240v Motor Neutral Load 5,000 VA 11,000 W Col C demand 8000 100% Demand No Demand No Demand Total Appliance Load 10,547 VA 4 or more demand @ 75% plus 100% demand loads 7,910 VA Total 3,000 VA 3,206 VA VA General Lighting Demand Load 1 Heating Load CU Load 5,800 VA 7,930 VA Greater of Heat @ 100% vs.A/C @ 100% Appliance Demand Load Dryer Demand Load Range Demand Load Service Demand Demand Load Neutral Demand Min.Service Req. Min. Feeder size Min. Neutral size Eq. Grding Cond. 7,930 VA 7,910 VA 5,000 VA 8,000 VA 35,046 VA 146 A 83 A 150 A 1 4 6 Copper 6,206 VA TITAN SOLAR POWER (855) 729-7652 525 W Baseline Rd. Mesa, AZ. 85210 2/17/22 9:16 Derate - MATHELIN JAMES LOAD CALCULATIONS E-3 3 OF 3 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A.32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE:PARCEL NUMBER: PROJECT ID: DOCUMENT CONTROL ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC DATE CAD QC MATHELIN JAMES 02-11-2022 191 NE CAPONA AVE PORT ST LUCIE FL 34983 3419-530-0225-000-6 TSP114074 02-01-22 JH NT