HomeMy WebLinkAboutBoundary Site Plan 5-24-2125_00'
s
U 3
z
0�
U
w -o'
N .— . O
o 0 1' 1
o n r
of
o_ w
00
LEGEND & ABBREVIATIONS
BB DENOTES BEARING BASE
CBS, DENOTES CONCRETE BLOCK STRUCTURE
C DENOTES CHORD BEARING & DISTANCE
DENOTES CENTER LINE
D.E. DENOTES DRAINAGE EASEMENT
F.F.E. DENOTES FINISH FLOOR ELEVATION
FND DENOTES FOUND
IR/C DENOTES IRON ROD AND CAP
L.B. DENOTES LICENSED BUSINESS
L DENOTES ARC LENGTH
N/D DENOTES NAIL AND DISK
O.S.T. DENOTES OPEN SPACE TRACT
P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER
P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR
R DENOTES RADIUS
R/W DENOTES RIGHT OF WAY
U.E. DENOTES UTILITY EASEMENT
W.M.T. DENOTES WATER MANAGEMENT TRACT
A DENOTES INCLUDED ANGLE
DENOTES DRAINAGE FLOW
DENOTES PROPOSED ELEVATION
;BENCHMARK
1SANITARY MANHOLE
TSS-50
RIM EL=16.07'
IN.A.V.D. 1988
SET 5/8" IR/C
LB 4286 (TYP)
77
VACANT
WATER
SERVICE
PRO >.
8 32 W
R POSED_n
ONCgETE
iRIVEWAY N
6 i-
�� M
5.20' 4.67"
0
0
r` SET 5/8" IR/C
� __,SET
LB 4286 (TYP)
0 o,—SANITARY
z SERVICE
Iw
LL
of
PROPOSED
COVERED 76
ENTRY PROPOSED
MODEL 4EBB/D
F.F.E.=18.60
GARAGE F.F.E.=18.00
EXISTING BUILDING
PAD EL=18.48
130.00'
v
45.1
V
MIN. S T CK REQ.
FRONT
SIDES
CNR SIDES
REAR
ZNG.
TECH.
SET 5/ " IR/C
LB 4281
(TYP)�\ /I
PROPOSED
COVERED
LANAI
8.0fO,—d-
8.037.13'
r SET 5/8" (R/C
N LB 4286 (TYP)
�-� 45.13'
J
S7'28'32"W 130.00'
Ln
0I
0
z
w
75 wl
VACANT I
o:
0
J
I
THOMAS P. KIERNAN
Professional Surveyor &- Mapper
Florida Certificate No. 6199
DATE
PROPERTY ADDRESS
r 3321 TRINITY CIRCLE, FORT PIERCE, FLORIDA
LEGAL DESCRIPTION
ON
u7
U7
w
00
N
r�
N
00
V)
F"3
AREA SUMMARY IN SQUARE FEET
SOD:4,351 t
DRIVEWAY/WALKWAY:600 f
GRAPHIC SCALE
20 0 10 20
(INS)
1 Inch - 20 sL
Being all of Lot 76, according to the plat of CREEKSIDE PLAT NO. 4, as
recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida.
Containing 0.164 acres, more or less.
GENERAL NOTES
1. The last date of field work was 5-14-20
2. Additions or deletions to survey maps or reports by other than the signing party or
parties is prohibited without written consent of the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of
a Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of
record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information
should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, the portion of this property scheduled for building
improvements is in Zone "X", according to the-LOMA Case No. 21-04-138A associated to
the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February
16, 2012. The exact designation can only be determined by an elevation certificate. There
may be additional map Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel
and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the
center line of Trinity Circle which bears South 82'31'28" East and all bearings are relative
thereto.
10. No easements are shown hereon other than those depicted on the plat. No search of
the public records has been performed to find additional easements that may exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on, the best available information, are
not certified to and must be verified prior to design or construction.
13. All improvements relating to this plat are either proposed or under construction.
ADD LOMR INFO JDJ 1 5/18/21
ADDED REAR TIE. JDJ 1 4/8/21
REVISION: REVISED LANAI JEB 11-20-2020