HomeMy WebLinkAboutEvaluation ReportAV
FILE COPY Registry No.29824
17520 Edinburgh Drive CREEK
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7T" EDITION (2020)
Manufacturer: MULE -HIDE PRODUCTS CO., INC.
1195 Prince Hall Dr
Beloit, WI 53511
(800) 786-1492
www.mulehide.com
Manufacturing Location: Pryor, OK
Quality Assurance: Keystone Certifications ,Inc. (QUA1824)
SCOPE
Issued August 12, 2021
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY BOCC
ZZ o 3 - &�-� Z 6
Category: Roofing
Subcategory: Underlayments
Code Edition: Florida Building Code, 7t" Edition (2020) including High -Velocity Hurricane Zones (HVHZ)
Code Sections: 1507.1.1, 1507.3.3, 1523.1.1, 1523.6.5.2.1
Properties: Physical properties
REFERENCES
ElL
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
GAPR-014-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
GAPR-018-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
GAPR-029-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
GAPR-030-02-01
ASTM D 1623
2017
PRI Construction Materials Technologies (TST5878)
GAPR-034-02-01
ASTM D 1623
2017
PRI Construction Materials Technologies (TST5878)
GAPR-034-02-01.1
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
GAPR-034-02-02
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
1047T0001
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0004.1
TAS 110
2000
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0011
TAS 110
2000
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0012
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
1047T0016
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0017
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0018.1
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0029
ASTM D 1623
2017
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0035
ASTM D 1623
2017
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0038
ASTM D 7379
2008 (2015)
PRI Construction Materials Technologies (TST5878)
1047T0046
UL1897
2012
ASTM D 903
1998(2010)
PRI Construction Materials Technologies (TST5878)
1047T0040
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0041
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
1047T0047A
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0047B
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0047C
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
1047T0049
ANSI/FM 4474
2011
MHP21001.3a FL37784-R2 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
MULE -HIDE PRODCTS
Shur -Gard Underlayments
Shur -Gard MU Force HT Shur -Gard MU Force HT is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High
Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self -adhered
underlayment constructed of a SBS polymer modified asphalt top coating and a
polymer film. The product is supplied in rolls having nominal dimensions of 39 3/8-in. x
66-ft.
Exposure on the roof deck shall be limited to a maximum 180 days. Tiles shall be
placed on battens for all roof slopes.
Shur -Gard MU Ultra HT Shur -Gard MU Ultra HT is a nominal 60-mil thick ASTM. D 1970 self -adhered
underlayment constructed of a dual SIBS polymer formulation and a non -woven,
synthetic surface. The product is supplied in rolls having nominal dimensions of 36-in, x
67-ft.
Exposure on the roof deck shall be limited to a maximum 120 days.
Shur -Gard TU Force HT Shur -Gard TU Force HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and
FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition
compliant self -adhered underlayment constructed of a dual SIBS polymer formulation
and a non -woven, polyester top surface. The product is supplied in 2 sq. rolls with
nominal dimensions of 39 3/8-in x 66-ft.
Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof
slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles
shall be placed on battens for roof slopes greater than 6:12.
Shur -Gard TU Ultra HT Shur -Gard TU Ultra HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and
FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition
self -adhered underlayment constructed of a dual SIBS polymer formulation and a non-
woven, polyester reinforced top surface. The product is supplied in 2 sq. rolls with
nominal dimensions of 39 3/8-in x 66-ft.
Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof
slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles
shall be placed on battens for roof slopes greater than 6:12.
MHP21001.3a FL37784-R2 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 in accordance with the FBC
MULE -HIDE PRODCTS
Shur -Gard Underlayments
Roof Deck: Shall be in accordance with the FBC requirements
In the non-HVHZ, the following roof deck substrates are permitted for direct deck applications:
—._.._ _...
-.......... ----......._...
-----.....
{ Primed
-.—__._�...-.
Primed
Primed
Underla ment
Plywood
( PI ood
OSB Concrete
Concrete
Shur -Gard MU Force HT
Y
I Y
N ! Y
Y
Shur -Gard MU Ultra HT
Y
I N
{-- N_� I— N
N
Shur -Gard TU Force HT --I
_
— Y
Y—
—
N
Y
Shur -Gard TU Ultra HT
Y
Y
N YH
Application: All undedayments shall be installed in accordance with the FBC and the manufacturer's
installation requirements.
Substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the
substrate shall be checked for protrusion and corrected prior to underlayment application. Prior to
beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-
5 minutes.
The Shur -Gard underlayments shall be installed with the release backer removed and pressed
firmly into place to ensure complete contact with the substrate. The underlayment shall be
installed with the roll length parallel to the eave, starting at the eave, and with 4" headlaps
(MetalGuard and Rain & Ice only) or 3" headlaps (TileGuard) and minimum 6" end laps staggered
min. 6-ft.from preceding course. Shur -Gard TU Force HT end laps shall be sealed with Mule -
Hide #420 Mod Bit Adhesive - Brush Grade or Mule -Hide #421 Mod Bit Flashing Adhesive -
Trowel Grade. -
In the HVHZ, the Shur -Gard underlayments shall be installed over one of more plies of ASTM D
226 Type II or ASTM D 2626 organic felt with minimum 4" headlaps and minimum 6" endlaps in
accordance with FBC Section 1518:3.
It is permissible to backnail the Shur -Gard underlayments 12-inches o.c. within the headlaps
(nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment).
Min. Application 40°F and rising; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
Roof Coverings: All Shur -Gard underlayments are permitted to be used with mechanically fastened metal roofing,
slate shingles, asphalt shingles, photovoltaic shingles, and composite plastic shingles in
accordance with the FBC.
Shur -Gard MU Force HT is permitted to be used with mechanically fastened clay and concrete
tiles set on battens only in accordance with the FBC.
Shur -Gard TU Ultra HT is permitted to be used with mechanically fastened clay and concrete tiles
in accordance with the FBC.
Shur -Gard TU Force HT is permitted to be used with mechanically fastened clay and concrete
roof tiles or clay and concrete roof tiles set in the following roof file adhesive in accordance with
the FBC.
1. DuPont TILE BONDTm Roof Tile Adhesive
2. DAP Touch'n Seal Storm Bond Roof Tile Adhesive
3. ICP Adhesives Polyset AH-160
MHP21001.3a FL37784-R2 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
MULE -HIDE PRODCTS
Shur -Gard Underlayments
WIND RESISTANCE OF ROOF TILE UNDERLAYMENT SYSTEMS
The Allowable Design Pressures below shall be used in accordance with the FRSA/TRI Florida High Ind Concrete
and Clay Tile Installation Manual, Sixth Edition for the selected underlayment system. The Allowable Design
Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
System No. 1 Direct Deck application
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: Shur -Gard MU Force HT, Shur -Gard TU Ultra HT or Shur -Gard TU Force HT shall
be self -adhered to the deck in accordance with manufacturer's installation instructions.
The underlayment may be optionally backnailed along the selvage with minimum
12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga.
x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with
a minimum 751b steel roller immediately following application.
Allowable Design Pressure: -90 psf
System No. 2 Direct Deck application
Roof Deck: Concrete primed with ASTM D 41 primer
Underlayment: Shur -Gard MU Force HT, Shur -Gard TU Ultra HT or Shur -Gard TU Force HT shall
be self -adhered to the deck in accordance with manufacturer's installation instructions.
The applied underlayment shall be rolled with a minimum 751b steel roller immediately
following application.
Allowable Design Pressure: -67.5 psf
GENERAL LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
3) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
4) All headlaps shall be installed to shed water from the deck.
5) The underlayment may be used as described in other current FBC product approval documents.
6) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
MHP21001.3a FL37784-R2 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
MULE -HIDE PRODCTS
Shur -Gard Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
t1F`Y 1R!'
�p����i
��. C-)
:�� Q' •'���ENSR' s �:
No 74021
13 STATE OF : 4U`
AL.E�`
nit III0
CERTIFICATION OF INDEPENDENCE
This item has been
digitally signed and
sealed by Zachary R.
Priest, PE, on 8/1212021.
Printed copies of this
document are not
considered signed and
sealed and the signature
must be verified on any
electronic copies.
2021.08.12
13:59:18
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
MHP21001.3a FL37784-R2 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
HR M M E R Hammer Roofing & Restoration, Inc.
v �" Naples (239) 300-9291
ROOFING
Miami (786)408-6168
!U Port St Lucie (772) 301-9963
www.HammerRoof.com
C�� n License #CCC1331828
Job # 148
Customer Name: Jennifer Nuhfer
Customer Phone: 305-491-9366
Address: 6724 dickinson ter, port saint lucie, fl , 34952
Sales Rep: Charles
Sales rep phone: 772-400-7996
Scope of work:
Manufacturer- Dynamic Metal
Type- 26 GA Standing Seam
Color- Mill Finish
Peel and stick— Mule Hide
drip edge color- Mill finish
6 pipestacks
2 6" gooseneck dryer vent
Add 2 10" gooseneck for ventilation
Gutter: Remove & dispose ----- add 140 ft white gutter 5
downspout
NOTE: 1 dead valley 3'x5' flat roof 1 sq capsheet(we
already have basesheet)
"PROTECT ALL LANDSCAPING, POOLS, DECKS
ETC. WITH PLYWOOD AND TARPS MUST CLEAN
JOB SITE DAILY! ! ! ! !