Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeI+'ile Copy FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TOM & SHARON ENGLISH Builder Name: f Vreet: 5339 MONTEGO CIRCLE Permit Office: CiVtate, Zip: FT. PIERCE, FL, Permit Number: Ovoft,�r: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (354.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=11.0 354.67 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(1) d. N/A R= ft2 10. Ceiling Types (235.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=19.0 235.00 ft2 6. Conditioned floor area above grade (ft2) 235 b. N/A R= ft2 Conditioned floor area below grade (ftz) 0 c. N/A R= ft2 11: Ducts R ft2 7. Windows(26.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Exterior 6 47 a. U-Factor: Dbl, U=0.65 26.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kStu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:13.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems - None required a. Cap: N/A pes (235.0 sgft. Insulation Area 8. FloorTypes y ) EF: 0.000 a. Raised Floor R=19.0 235.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.111 Total Proposed Modified Loads: 14.15 PASS Total Baseline Loads: 14.52 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the, Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: - Before construction is completed this building will be inspected for compliance with Section 553.908 0 F.;I y I hereby certify that this building, as designed, is in complian Florida Statutes. ✓�, �� B CO'D with the Florida Energy Cod J WE OWNER/AGENT: BUILDING OFFICIAL: DATE: 71DATE: / -r_r - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1/12/2017 6:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: TOM & SHARON ENGLISH Bedrooms: 1 User Conditioned Area: 235 Total Stories: 1 1 > Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Single-family Addition Address Type: Lot # Block/SubDivision: PlatBook: Street: County. City, State, Zip: Street Address 5339 MONTEGO CIRC ST. LUCIE COUNTY FT. PIERCE, FL, CLIMATE / V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 235 1880 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 1 ADDITION 235 1880 Yes 1 1 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor ADDITION 235 ft2 19 1 0 0 ROOF / # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or shed Composition shingles 255 ft2 48 ft2 Medium 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 235 ft2 L N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 19 Blown 235 ft2 0.11 Wood 1/12/2017 6:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS # Ornt Adjacent To Wall Type Cavity Width Height Sheathing Framing Solar Space R-Value Ft In Et In Area R-Value Fraction Ahsor Below Grade/ 1 N —2 E 3 S Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood ADDITION 11 13 8 8 109.3 ft2 0.23 0.5 ADDITION 11 17 8 136.0 ft2 0.23 0.5 ADDITION 11 13 8 8 109.3 ft2 0.23 0.5 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 2 E 2 Metal Low-E Double Yes 0.65 0.25' 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds E 2 Metal Low-E Double Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 219.3 12.04 22.65 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 13 35 kBtu/hr 1050 cfm 0.75 1 . sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft2 DUCTS # --- Supply -- Location R-Value Area -- Return -- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 47 ft2 Attic 10 ft2 Default Leakage Exterior (Default) (Default) 1 1 1/12/2017 6:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 Fr)PR l Rdnti_gnIA TEMPERATURES Programable Y Ceiling Fans: ]Thermostat: Heating X] Jan Feb Mar ki ri Jun Jul rl Au ri ri Se Sep Oct W Oct Nov Nov Dec H DecVenting [[ jj Jan Feb Mar Apr May Jun Jul Aug X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/12/2017 6:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TOM & SHARON ENGLISH Builder Name: Street: 5339 MONTEGO CIRCLE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/12/2017 6:17 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1